• Title/Summary/Keyword: IR radiation

Search Result 361, Processing Time 0.031 seconds

Optical Properties of Proton-irradiated Polyacrylonitrile Film (양성자 조사된 폴리아크릴로니트릴 필름의 광학적 특성)

  • Lee, Hwa-Su;Baek, Ga-Young;Jung, Jin-Mook;Hwang, In-Tae;Jung, Chan-Hee;Shin, Junhwa;Choi, Jae-Hak
    • Journal of Radiation Industry
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2016
  • In this study, the effect of high-energy proton irradiation on the optical properties of polyacrylonitrile (PAN) films was investigated. PAN thin films spin-coated on a substrate were irradiated 150 keV proton ions at various fluences. The changes in the chemical structure and optical properties were investigated by FT-IR and UV-vis spectroscopy. The results of the FT-IR analysis revealed that the cyclization reaction took place by proton irradiation and the degree of cyclization increased with an increasing fluence. Based on the UV-vis analysis, the optical band gap of PAN decreased from 2.84 to 2.52 eV with an increasing fluence due to the formation of carbon clusters by proton irradiation. In addition, the number of carbon atoms per carbon cluster and the number of carbon atoms per conjugation length were found to be increased with an increasing fluence.

A study of Brachytherapy for Intraocular Tumor (안구내 악성종양에 대한 저준위 방사선요법에 관한 연구)

  • Ji, Gwang-Su;Yu, Dae-Heon;Lee, Seong-Gu;Kim, Jae-Hyu;Ji, Yeong-Hun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • I. Project Title A Study of Brachytherapy for intraocular tumor II. Objective and Importance of the project The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. III. Scope and Contents of the project In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models IV. Results and Proposal for Applications The result were as followed. 1. Eye model was determined as a 25mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15mm, 17mm and 20mm in diameter, and 1.5mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ${\pm}10\%$ and distance deviations are within 0.4mm Maximum error is $-11.3\%$ and 0.8mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192 seeds.

  • PDF

Radiation Protection Effect of Mixed Extracts of Artemisia asiatica Nakai and Moringa oleifera Lam on Rats Uterus (흰쥐의 자궁에 대한 애엽-모링가 혼합추출물의 방사선 방호효과)

  • Lee, Yoon-Ji;Kim, Jang-Oh;Jeon, Chan-hee;Lee, Ji-Eun;Jeong, Geun-Woo;Jung, Do-Young;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.747-753
    • /
    • 2020
  • The purpose of this study was to examine the potential for the development of radioprotective agent in extracts manufactured by mixing Artemisia asiatica Nakai and Moringa oleifera Lam known as antioxidant food with the appropriate ratio. Their whole body were irradiated 7Gy radiation after oral administration of a mixed extract of Artemisia asiatica Nakai and Moringa oleifera Lam to SD Rat for two weeks. And 1 day, 7days, 21days later, changes in blood cell components, SOD activations and tissue changes in the uterus were observed.It was confirmed that the AM + IR group had a higher tendency to recover leukocyte (p<0.05) and platelet (p<0.05) levels than the IR group. It was also confirmed that SOD activity was increased and cell death was decreased in uterine tissue.Based on these results, the mixed extract of A and B is expected to be useful as a radiation protection agent capable of reducing blood cell and uterine damage caused by radiation exposure.

Performance Evaluation of Lead (II) Oxide Dosimeter for Digital Quality Assurance in Brachytherapy (방사선 근접치료의 디지털 정도관리를 위한 Lead (II) Oxide 선량계 성능 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.429-435
    • /
    • 2021
  • In intracavitary radiotherapy, incorrect location of the source can cause excessive dose to normal tissue, so it is essential to evaluate the location accuracy of the source. In this study, basic research was performed on digital line dosimeter based on lead (II) oxide (PbO) to improve analog verification method. Therefore, a polycrystalline PbO unit cell dosimeter was manufactured and the measurement performance for Ir-192 sources was evaluated. As a result, the reproducibility satisfies the evaluation criteria of 1.5% with a relative standard deviation of 0.85%. Linearity showed excellent results with a linear coefficient of R2 of 0.9998. In the case of distance dependence evaluation, the power function R2 showed 0.9855 for PbO and 0.9974 for diode, and the overall average difference was 1.66% for PbO and 2.18% for diode. This study presents the basic detection performance of the polycrystalline PbO dosimeter for the Ir-192 source and can provide basic data in the field of radiation measurement.

Study on the Physicochemical Properties of Crosslinked Poly(Styrene-Butadiene-Styrene) Block Copolymers Prepared by Radiation (방사선으로 제조된 가교 구조의 Poly(Styrene-Butadiene-Styrene) 블록 공중합체 특성에 관한 연구)

  • Lee, Sun-Young;Song, Ju-Myung;Sohn, Joon-Yong;Shin, Junhwa
    • Journal of Radiation Industry
    • /
    • v.6 no.2
    • /
    • pp.171-176
    • /
    • 2012
  • In this study, a crosslinked poly(styrene-butadiene-styrene) [SBS] block copolymers were prepared by using gamma ray irradiation method. The effects of various radiation doses on the degree of crosslinking, thermo property, and morphology of crosslinked SBS block copolymer were investigated. The degree of crosslinking of crosslinked SBS block copolymers were measured by gel-fraction and FT-IR. It was found that the degree of crosslinking of crosslinked SBS block copolymers increases with increase of the irradiation dose while the TGA result shows that the initial degradation temperature of irradiated SBS block copolymer was shifted to lower temperature with increasing irradiation dose. These results indicate that degradation reaction also occurs when SBS block copolymer is exposed to gamma ray irradiation for crosslinking reaction. The SAXS and FE-SEM results indicate that the phase separation of the styrene block and butadiene block was reduced with increasing irradiation dose.

The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구)

  • Ahn, Ki-Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.183-188
    • /
    • 2017
  • In recent years, the automatic remote control controller of the gamma ray irradiator malfunctions, and radiation workers are continuously exposed to radiation exposure accidents. In the non-destructive testing field, much time and resources are invested in establishing a radioactive source monitoring system in order to prevent potential incidents of radiation. In this study, the gamma-ray response properties of the lead monoxide-based radiation detector were estimated through monte carlo simulation as a previous study for the development of a radioactive source location monitoring system that can be applied universally to various non-destructive testing equipment. As a result of the study, the optimized thickness of the radiation detector varies according to the gamma-ray energy emitted from the radioactive source, and the optimized thickness gradually increases with increasing energy. In conclusion, the optimized thickness of the lead monoxide-based radiation detector was $200{\mu}m$ for the Ir-192, $150{\mu}m$ for the Se-75 and $300{\mu}m$ for the Co-60. Based on these results, the appropriate thickness of lead monoxide-based radiation detector considering secondary-electron equilibrium was evaluated to be $300{\mu}m$ for general application. These results can be used as a basic data for determining the appropriate thickness required in the radiation detector when developing a radiation source location monitoring system for universal application to various non-destructive testing equipment in the future.

The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 반도체 검출기 설계에 관한 연구)

  • Kim, Kyo-Tae;Kim, Joo-Hee;Han, Moo-Jae;Heo, Ye-Ji;Ahn, Ki-Jung;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.171-175
    • /
    • 2017
  • In the non-destructive inspection field, we invest a lot of time and resources in developing the radiation source system to ensure the safety of the workers. However, the probability of accidents is still high. In order to prevent potential radiation accidents in advance, it is necessary to directly verify the position of the radiation source, but the research is still insufficient. In this study, we developed a monitoring system that can detect the position of the radiation source in the source guide tube in the gamma-ray irradiator. The characteristics of the radiation detector are estimated by monte carlo simulation. As a result, the radiation detector for Ir-192 gamma-ray energy was analyzed to have secondary electron equilibrium at $150{\mu}m$ regardless of the semiconductor material. Also, it is expected that the gamma ray response characteristic is the best in $HgI_2$. These results are expected to be used as a basis for determining the optimal thickness of the radiation detector located in the detection part of the future monitoring system. In addition, when developing a monitoring system based on this, radiation workers can easily recognize the danger and secure safety, as well as prevent and preemptively respond to potential radiation accidents.

Far Infrared Radiation Characteristics of Germanium Compounds (게르마늄 화합물의 원적외선 방사특성)

  • Lee, Hyun-Kyung;Lee, Kyung-Mee
    • Applied Chemistry for Engineering
    • /
    • v.17 no.6
    • /
    • pp.597-603
    • /
    • 2006
  • In order to study the effects of $GeO_{2}$ contents in $XSiO_{2}{\cdot}YGeO_{2}$ and $XSiO_{2}{\cdot}YNa_{2}O{\cdot}ZGeO_{2}$ compounds on far infrared ray radiation, we investigated the sample of $XSiO_{2}{\cdot}YGeO_{2}$ and $XSiO_{2}{\cdot}YNa_{2}O{\cdot}ZGeO_{2}$ using TG-DTA, XRD, FT-IR spectrophotometer and FT-IR spectrometer. The far infrared ray emissivity and emission power were increased with the increase of $GeO_{2}$ contents in $XSiO_{2}{\cdot}YGeO_{2}$ and $XSiO_{2}{\cdot}YNa_{2}O{\cdot}ZGeO_{2}$ compounds. The far infrared ray emissivity and emission power of $XSiO_2{\cdot}YGeO_2$ compounds were higher than those of $XSiO_{2}{\cdot}YNa_{2}O{\cdot}ZGeO_{2}$ compounds.

Application of sigmoidal optimization to reconstruct nuclear medicine image: Comparison with filtered back projection and iterative reconstruction method

  • Shin, Han-Back;Kim, Moo-Sub;Law, Martin;Djeng, Shih-Kien;Choi, Min-Geon;Choi, Byung Wook;Kang, Sungmin;Kim, Dong-Wook;Suh, Tae Suk;Yoon, Do-Kun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.258-265
    • /
    • 2021
  • High levels for noise and a loss of true signal make the quantitative interpretation of nuclear medicine (NM) images difficult. An application of profile optimization using a sigmoidal function in this study was used to acquire the NM images with high quality. And the images were acquired by using three kinds of reconstruction method using each same sinogram: a standard filtered back-projection (FBP), an iterative reconstruction (IR) technique, and the sigmoidal function profile optimization (SFPO). Comparison of image according to reconstruction method was performed to show a superiority of the SFPO for imaging. The images reconstructed by using the SFPO showed an average of 1.49 times and of 1.17 times better in contrast than the results obtained using the standard FBP and the IR technique, respectively. Higher signal to noise ratios were obtained as an average of 12.30 times and of 3.77 times than results obtained using the standard FBP and the IR technique, respectively. This study confirms that reconstruction with SFPO (vs FBP and vs IR) can lead to better lesion detectability and characterization with noise reduction. It can be developed for future reconstruction technique for the NM imaging.