• Title/Summary/Keyword: IR frequency

검색결과 280건 처리시간 0.032초

4H-SiC 표면에서 AFM의 산화 패턴 제작 (AFM fabrication of oxide patterns on 4H-SiC surface)

  • 조영득;방욱;김상철;김남균;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.64-64
    • /
    • 2009
  • Atomic force microscopy (AFM) fabrication of oxide patterns is an attractive technique for nanoscale patterns and related device structures, SiC exhibits good performance in high-power, high-frequency, and high-temperature conditions that is comparable to the performance of Si. The AFM fabrication of oxide patterns on SiC is important for electronic applications. However, there has not been much reported investigations on oxidation of SiC using AFM. We achieved the local oxidation of 4H-SiC using the high loading force of ~100 nN, although the oxidation of SiC is generally difficult mainly due to the physical hardness and chemical inactivity. All the experiments were performed using atomic force microscopy (S.I.S. GmbH, Germany) with a Pt/Ir-coated Si tip at ~40% humidity and room temperature. The spring constant and resonance frequency of the tip were around ~3 N/m and ~70 kHz. We fabricated oxide patterns on n-type 4H-SiC ($\sim10^{19}/cm^3$) and n-type Si ($\sim1.9\times10^{16}/cm^3$). In summary, we demonstrated that the oxide patterns can be obtained over the electric field of ${\sim}\times10^7 V/cm$ and the high loading force using the tip as a cathode. The electric field transports the oxyanions (OH-) to the positively biased surface.

  • PDF

TFT-LCD 드라이버를 위한 8-bit 230MSPS Analog Flat Panel InterFACE의 설계 (Design of an 8-bit 230MSPS Analog Flat Panel Interface for TFT-LCD Driver)

  • 윤성욱;임현식;송민규
    • 대한전자공학회논문지SD
    • /
    • 제39권2호
    • /
    • pp.1-6
    • /
    • 2002
  • 본 논문에서는 UXGA(Ultra extended Graphics Array)급 TFT LCD Driver를 지원하는 Analog Flat Panel Interface(AFPI)용 Module을 설계하였다. 제안하는 AFPI는 8-b ADC, 자동이득 제어기(AGC), 저잡음 PLL로 구성 되어있다. 8-b ADC는 고속동작과 저전력 기능을 위한 새로운 구조로서 FR(Folding Rate)이 8, NFB(Number of Folding Block)이 2, Interpolation rate이 16이며, 분산 Track and Hold구조를 사용하여 Sampling시 입력주파수를 낮추어 높은 SNDR을 얻을 수 있었다. 또한 Gain과 Clamp을 통제 할 수 있는 Programmable한 AGC, 낮은 Jitter Noise PLL을 설계하였다. 제안된 Module은 0.2㎛, 1-Poly 5-Metal, n-well CMOS공정을 사용하여 제작되었으며, 유효 칩 면적은 3.6mm × 3.2mm이고 602㎽의 전력소모를 나타내었다. 입력 주파수는 10㎒, 샘플링 주파수 200㎒에서의 INL과 DNL은 ±1LSB 이내로 측정되었으며, SNDR은 43㏈로 측정되었다.

고효율 펄스스타트 메탈핼라이드램프(MH200W)의 음향공명현상감소 (Reduction of Acoustic Resonance Phenomena in Pulse Start MetalHalide Lamp (MH200W))

  • 김기정
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.8-14
    • /
    • 2001
  • 메탈핼라이드램프는 고효율, 고연색성이며 집광능력이 좋다. 그러나 메탈핼라이드 램프의 단점은 아크튜브내에서 음향공명현상이 발생되는 것으로 알려져 있다. 이러한 음향공명은 점등상태의 불안정과 기체의 심한 파동을 일으킨다. 심한 파동과 불안정한 점등으로 아크가 소멸되는 부위는 전압이 상승되고, 방전관내벽에 근접된 아크는 국부의 과열로 튜브를 금가게한다. 이 연구의 목적은 펄스스타트 메탈핼라이드램프 MH200[W]의 아크튜브내에서 음향공명을 감소시키는 것이다. 음향공명현상을 감소시키기 위하여 전자식안정기가 84.6[kHz]에서 94.2[kHz] 대역내에 있는 89[kHz]의 단독주파수인 정현고주파를 램프에 공급하기 위하여 설계되었다. 실험결과 고효율 펄스스타트 MH200[W] 램프의 방전관내에 음향공명 현상이 없었다.

  • PDF

위상잠금 열화상 기법의 최적 실험 조건 탐색 연구 (An Exploratory Study on the Optimized Test Conditions of the Lock-in Thermography Technique)

  • 조용진
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.157-164
    • /
    • 2011
  • 위상잠금 적외선 열화상(lock-in infrared thermography) 기법의 조선해양공학 분야에 적용 가능성을 검토하였다. 이를 위해 실험계획법에 의해 향상된 결함부와 건전부의 위상차 대비영상을 얻기 위한 탐색 연구를 수행하였다. 위상차 대비영상의 평가를 정량회하기 위하여 대비 기준표와 홀 크기에 가중치를 주는 방법을 적용하여 유용한 판별기준임을 입증하였다. 그리고 표면에 광 조사 세기는 중간이나 낮은 조사량이 좋은 결과를 보여주고, 높은 조사는 유용한 결과를 주지 못했다. 위상잠금 주파수는 가진 광원의 세기에 비례하여 좋은 결과를 획득할 수 있었고, 열화상 카메라의 노출시간(integration time)은 조사 광원의 세기와 반비례하여 실험을 수행하는 것이 좋은 결과를 얻을 수 있었다. 그러나 시험편(specimen)의 차이는 약간의 편향된 결과를 얻었지만 유의하지는 못했다.

방전 플라스마에 의한 CFC-12($CCl_2F_2$)의 분해 (Decomposition of CFC-12($CCl_2F_2$) by Discharge Plasma)

  • 강현춘;우인성;황명환;안형환;이한섭;조정국;강안수
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.93-100
    • /
    • 1999
  • Decomposition efficiency, power consumption, and applied voltage of CFC(Chlorofluorocatbon) were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of CFC-12 with various electric frequencies(5~50kHz). flow rates (100~1,000mL/min), initial concentrations(100~1,000ppm), electrode materials(W, Cu, Al). electrode thickness(1, 2, 3mm) and reference gases($N_2$, $O_2$, air) were measured and the products were analyzed with FT-IR. Experimental results showed that at the frequency of 10kHz, the highest decomposition efficiency of 92.7% for CFC-12 were observed at the power consumptions of 29.6W. respectively, and that decomposition efficiency decreased with increasing frequency above 20kHz and decomposition efficiency per unit power were 3.13%/W for CFC-12. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3m. As the electrode material, decomposition efficiency was in order that tungsten(W), copper(Cu), aluminum (Al). Decomposition of CFC-12 in the reference gas of $N_2$ showed the highest efficiency among three reference gases, and then the effect of reference gas on the decomposition efficiency decreased in order of air and $O_2$. The optimum power for the maximum decomposition efficiency was 25.3W for CFC.

  • PDF

간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구 (Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography)

  • 민정환;정회원;김기원;권경태;정재용;손진현;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

소형 밀리미터파 레이더를 위한 실시간 데이터 전처리 방법 연구 (A Study on Real-time Data Preprocessing Technique for Small Millimeter Wave Radar)

  • 최진규;신영철;홍순일;박창현;김윤진;김홍락;권준범
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권6호
    • /
    • pp.79-85
    • /
    • 2019
  • 최근 소형 레이더는 한번의 타격으로 표적의 시스템을 무능화시키기 위해 높은 거리해상도를 갖는 소형 밀리미터파 레이더 개발을 요구한다. 높은 거리해상도를 갖는 소형 밀리미터파 레이더가 표적을 획득하고, 추적하기 위해서는 대용량의 데이터를 실시간으로 처리해야한다. 본 논문에서는 소형 밀리미터파 레이더에서 요구하는 대용량의 데이터를 실시간으로 처리하기 위한 실시간 데이터 전처리 방법을 정리하였다. 또한 실시간 데이터 전처리 방법으로 제시한 디지털 IF(Intermediate Frequency) 수신기, Window처리, DFT(Discrete Fourier Transform)를 FPGA (Field Programmable Gate Array)를 활용하여 구현하였다. 마지막으로 구현한 실시간 데이터 전처리 모듈은 소형 밀리미터파 레이더를 위한 신호처리기에 적용하여 실시간 데이터 전처리 기능과 관련된 성능시험으로 검증하였다.

$TiO_2$ 촉매를 이용한 플라즈마반응에 의한 NOx의 분해 (Reduction and Decomposition of Hazardous NOx by Discharge Plasma with $TiO_2$)

  • 박성국;우인성;황명환
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.54-60
    • /
    • 2008
  • The objective of this study is to obtain the optimal process condition and the maximum decomposition efficiency by measuring the decomposition efficiency, electricity consumption, and voltage in accordance with the change of the process variables such as the frequency, maintaining time period, concentration, electrode material, thickness of the electrode, the number of windings of the electrode, and added materials etc. of the harmful atmospheric contamination gases such as NO, $NO_2$, and $SO_2$ etc. with the plasma which is generated by the discharging of the specially designed and manufactured $TiO_2$ catalysis reactor and SPCP reactor. The decomposition efficiency of the NO, the standard samples, is obtained with the plasma which is being generated by the discharge of the combination effect of the $TiO_2$ catalysis reactor and SPCP reactor with the variation of those process variables such as the frequency of the high voltage generator($5{\sim}50kHz$), maintaining time of the harmful gases($1{\sim}10.5sec$), initial concentration($100{\sim}1,000ppm$), the material of the electrode(W, Cu, Al), the thickness of the electrode(1, 2, 3mm), the number of the windings of the electrode(7, 9, 11turns), basic gases($N_2$, $O_2$, air), and the simulated gas($CO_2$) and the resulting substances are analyzed by utilizing FT-IR & GC.

Relationship between Infrared Peak Maximum Position and Molecular Interactions

  • Ryu, Soo-Ryeon;Noda, Isao;Jung, Young-Mee
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권11호
    • /
    • pp.4011-4015
    • /
    • 2011
  • We explored the interpretation of the well-accepted correlation between the apparent peak maximum position shift and extent of molecular interactions, like hydrogen bonding and dipole-dipole interactions, based on the overlapped multiple band model. The simulation of two overlapped Lorentzian bands was carried out to interpret how the maximum position of a composite peak relates to the relative contributions of two species representing the different levels of molecular interactions, i.e., free (or very weekly bound) vs. strongly bound. To demonstrate the validity of our interpretation of the origin of the peak position shift, the temperaturedependent IR spectra of ethylene glycol were also analyzed. It was found through the analysis of simulated and experimental spectra that the apparent peak shift in certain case can be safely interpreted as the measure of the strength of hydrogen bonding. The result of this study gives a new insight to interpret molecular interactions probed by vibrational spectroscopy.

적외선 센서를 이용한 초음파 용착부의 마찰열 측정 (Temperature Measurement on Ultrasonic Weld Surfaces by Using an Infrared Sensor)

  • 김원호;강은지;민경탁
    • 한국생산제조학회지
    • /
    • 제26권4호
    • /
    • pp.425-429
    • /
    • 2017
  • During ultrasonic welding, plastic deformation, elastic hysteresis, and friction generate heat at the contact portions of the two materials to be welded, theoretically analyzing and experimentally measuring the temperature at the welded part are very important for identifying the heat affected zone. However, the welding temperature during ultrasonic welding wherein welding is performed in less than a second is a challenge. We investigated the effects of welding conditions such as welding time, welding pressure, and the ultrasonic vibration amplitude of horns on the temperature of welded surface of a Ni sheet of thickness 0.1 mm. We used a horn with a resonance frequency of 40 kHz and an ultrasonic welder. The temperature was measured using a intrared sensor, and its characteristics were investigated. Experimental results showed that increase in welding time and pressure and ultrasonic vibration amplitude of horns generally caused the increase in surface temperature of the weld.