• Title/Summary/Keyword: IR System

Search Result 1,389, Processing Time 0.024 seconds

Development of the Construction Waste Management Performance Evaluation Tool (WMPET): Quantification of Waste Management Performance Factors and Establishment of Waste Management Performance Evaluation Tool (건설현장의 폐기물 관리 성과 평가 툴 개발 : 2단계 - 폐기물 관리 성과 요인의 전량화 및 평가 툴 구축)

  • Kim, Jee-Hye;Shin, Dong-Woo;Cha, Hee-Sung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.4
    • /
    • pp.128-136
    • /
    • 2007
  • As the international-level concern has been focused on the environmental sustainability in recent years, many researches emphasized the needs for methods and techniques that would facilitate sustainability assessment at the various project level interfaces. As part of methods and techniques to facilitate sustainability assessment, this paper provides 'Computerized Waste Management Performance Evaluation Tool' for the purpose of assessing the level of management system in dealing with the onsite construction wastes. This tool applies twenty-three waste management performance factors for the purpose of evaluating the level of waste management performance by scoring those factors which were identified in the previous research. These twenty-three factors are classified into four categories: manpower, material, method, and management based on their characteristics. In order to quantitatively evaluate the effectiveness of waste management performance, the levels of actions executed in a site by each waste management performance factor were identified and their weight were analyzed throughout the expert interview and survey. Furthermore, an excel-based computerized tool was developed in order to facilitate the evaluation process. If this tool can be developed in more detail and be used as the method to control waste management at a project level for the future, it is expected that this tool can play an important role in the body of knowledge of environmental management in construction industry.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.23-26
    • /
    • 2005
  • Introduction: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Methods and Materials: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator , an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was performed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS (192-Ir HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3000cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Result: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1cGy, 57.1cGy, 103.8cGy, 162.7cGy, 165.7cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1cGy, 57.1cGy Conclusion: Patients with locally recurrent tumor in uterine cervix cancer treated with modified MIUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry Provided by the template and cylinders, and improved dose distributions in irregular tumor volume without rectal complication

  • PDF

Protein molecular structure, degradation and availability of canola, rapeseed and soybean meals in dairy cattle diets

  • Tian, Yujia;Zhang, Xuewei;Huang, Rongcai;Yu, Peiqiang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.9
    • /
    • pp.1381-1388
    • /
    • 2019
  • Objective: The aims of this study were to reveal the magnitude of the differences in protein structures at a cellular level as well as protein utilization and availability among soybean meal (SBM), canola meal (CM), and rapeseed meal (RSM) as feedstocks in China. Methods: Experiments were designed to compare the three different types of feedstocks in terms of: i) protein chemical profiles; ii) protein fractions partitioned according to Cornell Net Carbohydrate and Protein System; iii) protein molecular structures and protein second structures; iv) special protein compounds-amino acid (AA); v) total digestible protein and energy values; vi) in situ rumen protein degradability and intestinal digestibility. The protein second structures were measured using FT/IR molecular spectroscopy technique. A summary chemical approach in National Research Council (NRC) model was applied to analyze truly digestible protein. Results: The results showed significant differences in both protein nutritional profiles and protein structure parameters in terms of ${\alpha}-helix$, ${\beta}-sheet$ spectral intensity and their ratio, and amide I, amide II spectral intensity and their ratio among SBM, CM, and RSM. SBM had higher crude protein (CP) and AA content than CM and RSM. For dry matter (DM), SBM, and CM had a higher DM content compared with RSM (p<0.05), whereas no statistical significance was found between SBM and CM (p = 0.28). Effective degradability of CP and DM did not demonstrate significant differences among the three groups (p>0.05). Intestinal digestibility of rumen undegradable protein measured by three-step in vitro method showed that there was significant difference (p = 0.05) among SBM, CM, and RSM, which SBM was the highest and RSM was the lowest with CM in between. NRC modeling results showed that digestible CP content in SBM was significantly higher than that of CM and RSM (p<0.05). Conclusion: This study suggested that SBM and CM contained similar protein value and availability for dairy cattle, while RSM had the lowest protein quality and utilization.

Development of Proto-type Program for Automatic Change Detection and Cueing of Multi-temporal KOMPSAT-5 SAR Imagery (다중시기 KOMPSAT-5 SAR 위성영상의 자동변화탐지알림 프로토타입 프로그램 개발)

  • Chae, Sung-Ho;Oh, Kwan-Young;Lee, Sungu
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_4
    • /
    • pp.1955-1969
    • /
    • 2022
  • Most of the public and private users who use national satellite information such as the KOMPSAT series mainly use Electro-Optical and Infrared (EO/IR) satellite images, and the utilization of Synthetic Aperture Radar (SAR) images is relatively insufficient. As KOMPSAT-5 currently in operation, KOMPSAT-6 and micro SAR satellite constellation systems are scheduled to be launched in the future, the demand for utilization of SAR satellite information is increasing in various fields. Accordingly, it is necessary to possess core technology for SAR utilization that can support the utilization of SAR satellite information for users. Due to the all-weather properties of SAR system, change detection technology is a key application technology. However, until now, the development of technology that automatic change detection and cueing using SAR images is insufficient. Through this study, the requirements of automatic change detection and cueing function using multi-temporal KOMPSAT-5 SAR satellite images were derived and a prototype program was developed. This prototype program aims to secure independent SAR utilization technology and promote the utilization of domestic SAR satellite information by practitioners in public sector organizations in Korea.

Counting and Localizing Occupants using IR-UWB Radar and Machine Learning

  • Ji, Geonwoo;Lee, Changwon;Yun, Jaeseok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.5
    • /
    • pp.1-9
    • /
    • 2022
  • Localization systems can be used with various circumstances like measuring population movement and rescue technology, even in security technology (like infiltration detection system). Vision sensors such as camera often used for localization is susceptible with light and temperature, and can cause invasion of privacy. In this paper, we used ultra-wideband radar technology (which is not limited by aforementioned problems) and machine learning techniques to measure the number and location of occupants in other indoor spaces behind the wall. We used four different algorithms and compared their results, including extremely randomized tree for four different situations; detect the number of occupants in a classroom, split the classroom into 28 locations and check the position of occupant, select one out of the 28 locations, divide it into 16 fine-grained locations, and check the position of occupant, and checking the positions of two occupants (existing in different locations). Overall, four algorithms showed good results and we verified that detecting the number and location of occupants are possible with high accuracy using machine learning. Also we have considered the possibility of service expansion using the oneM2M standard platform and expect to develop more service and products if this technology is used in various fields.

Improved Copper Ion Recovery Efficiency through Surface Modification of Membranes in the Electrodialysis/Solvent Extraction Process (전기투석/용매추출 공정에서 멤브레인 표면 개질을 통한 구리 이온의 회수 효율 향상)

  • Joongwon, Park;Rina, Kim;Hyunju, Lee;Min-seuk, Kim;Hiesang, Sohn
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.486-495
    • /
    • 2022
  • This study presents the improved recovery efficiency of rare metal ions through the modified separation membrane wettability and hydrogen ion permeation in the anion exchange membrane (AEM) under the recovery process of combined electrodialysis and solvent extraction. Specifically, the wettability of the separator was enhanced by hydrophilic modification on one separator surface through polydopamine (PDA) and lipophilic modification on the other surface through SiO2 or graphene oxide (GO). In addition, the modified surface of AEM with polyethyleneimine (PEI), PDA, poly(vinylidene fluoride) (PVDF), etc. reduces the water uptake and modify the pore structure for proton ions generation. The suppressed transport resulted in the reduced hydrogen ion permeation. In the characterization, the surface morphology, chemical properties and composition of membrane or AEM were analyzed with Scanning Electron Microscopy (SEM) and Fourier Transform-Infrared Spectroscopy (FT-IR). Based on the analyses, improved extraction and stripping and hydrogen ion transport inhibition were demonstrated for the copper ion recovery system.

Characterization of Repeated Deactivation and Subsequent Re-activation of Photocatalyst Used in Two Alternatively-operating UV/photocatalytic Reactors of Waste-air Treating System (교대로 운전되는 두 개의 UV/광촉매반응기로 구성된 폐가스 처리시스템에서의 광촉매의 비활성화 및 재생 특성)

  • Lee, Eun Ju;Chung, Chan Hong;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.584-595
    • /
    • 2021
  • In this study, the correlation between operating stages of waste air-treating system composed of two alternatively-operating UV/photocatalytic reactors, and the deactivation of photocatalyst used in each operating stage, was investigated by instrumental analysis thereon. The repeated deactivation and subsequent re-generation of photocatalyst used in the waste air treating system of previous investigation performed by Lee and Lim (Korean Chem. Eng. Research, 59(4), 574-583(2021)), were characterized on virgin photocatalyst-carrying porous SiO2 media (A4), used photocatalyst-carrying porous SiO2 media (A1, A2 and A3) collected from the corresponding photocatalytic reactor upon 1st, 2nd, and 3rd run, respectively, regenerated photocatalyst-carrying porous SiO2 media upon 1 time-run (AD1) and 3 times regenerated photocatalyst-carrying porous SiO2 media upon 3 time-runs (AD3) by instrumental analysis including BET analysis, SEM, XPS, SEM-EDS and FT-IR. As a result, the proper regeneration-temperature for deactivated photocatalyst to be regenerated several times (more than 3 times), was suggested below 200 ℃. Such temperature of deactivated photocatalyst-regeneration was almost consistent to the one, according to BET analysis, at which tiny nano-pores blocked by adsorbed ethanol-oxidative and degraded intermediates (AEODI), were regenerated to be reopened through almost complete mineralization of AEODI. In particular, the results of XPS analysis indicated an incurrence of insignificant deactivation of photocatalysis upon 1st run of UV/photocatalytic reactor (A or C) of the previous investigation. In addition, the results of XPS analysis were consistent with the experimental results of the previous investigation in that 1) deactivation of photocatalyst incurred during 2nd run of the UV/photocatalytic reactor (A or C) resulted in decreased removal efficiency, by ca. 5% and 5%, of ethanol and hydrogen sulfide, respectively, compared with its 1st run; 2) there was insignificant difference between the removal efficiencies of its 2nd run and 3rd run. Furthermore, the removal efficiencies of ethanol and hydrogen sulfide for hypothetical 4th run of photocatalytic reactor in the previous investigation, using AD3, were expected to decrease, compared with its 3rd run, by much more than those for 2nd run in the previous investigation did, compared with its 1st run.

Preliminary Results of Concurrent Chemotherapy and Radiation Therapy using High-dose-rate Brachytherapy for Cervical Cancer (자궁경부암에 항암화학요법과 동시 병용요법으로 외부 방사선조사와 고선량률 강내조사의 예비적 치료 결과)

  • Lee, Kyung-Ja;Lee, Ji-Hye;Lee, Re-Na;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.171-178
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. $\underline{Materials\;and\;Methods}$: From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range $34{\sim}74$) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follows: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of $45{\sim}50.4\;Gy$ (median: 50.4 Gy) over $5{\sim}5.5$ weeks. Ir-192 HDR intracavitary brachytherapy (ICBT) was given after a total dose of 41.4 Gy. HDR-ICBT was performed twice a week, with a fraction point A dose of 4 Gy and median dose to point A was 28 Gy (range: $16{\sim}32\;Gy$) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT+ICBT) was $88\;Gy_{10}$ (range: $77{\sim}94\;Gy_{10}$). The median cumulative BED at ICRU 38 reference point (EBRT+ICBT) was $131\;Gy_3$ (range: $122{\sim}140\;Gy_3$) at point A, $109\;Gy_3$ (range: $88{\sim}125\;Gy_3$) at the rectum and $111\;Gy_3$ (range: $91{\sim}123\;Gy_3$) at the urinary bladder. Cisplatin ($60\;mg/m^2$) and 5-FU ($1,000\;mg/m^2$) was administered intravenously at 3 weeks interval from the first day of radiation for median 5 (range: $2{\sim}6$) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range: $8{\sim}50$ months). $\underline{: The complete response rate after concurrent chemoradiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure rate was 13% and distant metastatic rate was 3.3%. The crude rate of minor hematologic complications (RTOG grade 1-2) occurred in 3 patients (10%) and one patient had suffered from severe leukopenia (RTOG grade 4) during concurrent treatment. Acute minor enterocolitis (RTOG grade 1-2) occurred in 11 patients (37%) and one patient (3%) was suffered from colon perforation during radiation therapy. Late colitis of RTOG grade 1 occurred in 5 patients (15%). Acute cystitis of RTOG grade 1 occurred in 12 patients (40%) and late cystitis of RTOG grade 2 occurred in one patient (3%). No treatment related death was seen. $\underline{Conclusion}$: The results of this study suggest that the concurrent chemoradiation therapy with HDR brachytherapy could be accepted as an effective and safe treatment for cervical cancer.

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

Proposal on for Response System to International Terrorism (국제 테러리즘의 대응체제 구축방안)

  • Suh, Sang-Yul
    • Korean Security Journal
    • /
    • no.9
    • /
    • pp.99-131
    • /
    • 2005
  • Terrorism which became today's common phenomena over the world is one of the most serious threats the world confront. Although International society make and operate outstanding anti-terrorism system, terror would never end without solving fundamental problems. The main body of terrorism converts from nation to organization and from organization to cell, which makes it difficult for us to recognize the main body. Since the target of today's new terrorism is many and unspecified persons, terrorists will never hesitate to use mass destruction weapons such as nuclear, biological, chemical weapons, and also use cyber-technique or cyber-terrorism. So, effective counter-terrorism measures should be performed as follows. First, it must be better for international society should make long-time plan of solving fundamental problems of terrorism other than to operate directly on terror organization and its means. Second, preventive method should be made. The most effective method of eradicating terrorism is prevention. For this, it is necessary to remove environmental elements of terrorism and terrorist bases, and to stop inflow of money and mass destruction weapons to terrorists. Third, integrated anti-terror organization should be organized and operated for continuous counter-terrorism operations. Also international alliance for anti-terrorism should be maintained to share informations and measures. Fourth, concerned department in the government should prepare counter-terrorism plans in their own parts as follows and make efforts to integrate the plans. - Ministry of Government Administration and Home Affairs : conventional terror - Ministry of Health and Welfare : bio-terror - Ministry of Science and Technology : nuclear-terror Especially, they should convert their policy and operation from post-terror actions to pre-terror actions, designate terror as national disaster and organize integrated emergency response organization including civil, government, and military elements. In conclusion, pre-terror activities and remedy of fundamental causes is the best way to prevent terror. Also, strengthening of intelligence activities, international cooperations, and preventive and comprehensive counter-measures must not ignored.

  • PDF