• Title/Summary/Keyword: IR System

Search Result 1,388, Processing Time 0.034 seconds

Preliminary research for molecular markers of two invasive toxic weeds, Cenchrus L. (Poaceae) species, based on NGS technique

  • Hyun, JongYoung;Jung, Joonhyung;Do, Hoang Dang Khoa;Kim, Joo-Hwan
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.71-71
    • /
    • 2019
  • The genus Cenchrus (Poaceae), containing ca. 23 species, is distributed throughout Australia, Africa, Indian sub-continent, and America. In Korea, Cenchrus longispinus (Hack.) Fernald, especially introduced to Daecheong Island in 1999, is one of the most hazardous invasive plant which causes serious environmental threats, biodiversity damages and physically negative impact on humans and animals. Based on the next-generation sequencing (NGS) technology, we characterized the chloroplast (cp) genome sequences of C. longispinus which contains a large single copy (LSC; 80,223 bp), a small single copy (SSC; 12,449 bp), separated by a pair of inverted repeats (IRs; 22,236 bp). Additionally, we analyzed the cp genome sequences of Cenchrus echinatus L. which contains a large single copy (LSC; 80,220 bp), a small single copy (SSC; 12,439 bp), separated by a pair of inverted repeats (IRs; 22,236 bp). These cp genomes consist of 75 unique genes, 4 rRNA coding genes, 33 tRNA coding genes and 21 duplicated in the IR regions, of which the gene content and organization are similar to the other Poaceae cp genomes. We selected 40 potential regions in cp genomes of two Cenchrus species and one Korean Pennisetum species to develop new single nucleotide polymorphism (SNP) markers for identifying C. longispinus based on amplification-refractory mutation system (ARMS) technique. The markers, inferred from SNP in matK and ndhF genes, show effectiveness to recognize C. longispinus from C. echinatus and Korean native species Pennisetum alopecuroides (L.) Spreng.

  • PDF

Dispersion Stability and Mechanical Properties of ZrO2/High-temp Composite Resins by Nano- and Micro-particle Ratio for Stereolithography 3D Printing (나노 및 마이크로 입자 비율에 따른 광조형 3D 프린팅용 ZrO2/High-temp 복합 수지의 분산 안정성 및 기계적 특성)

  • Song, Se Yeon;Park, Min Soo;Yun, Ji Sun
    • Korean Journal of Materials Research
    • /
    • v.29 no.4
    • /
    • pp.221-227
    • /
    • 2019
  • This study examines the role of the nano- and micro-particle ratio in dispersion stability and mechanical properties of composite resins for SLA(stereolithography) 3D printing technology. VTES(vinyltriethoxysilane)-coated $ZrO_2$ ceramic particles with different nano- and micro-particle ratios are prepared by a hydrolysis and condensation reaction and then dispersed in commercial photopolymer (High-temp) based on interpenetrating networks(IPNs). The coating characteristics of VTES-coated $ZrO_2$ particles are observed by FE-TEM and FT-IR. The rheological properties of VTES-coated $ZrO_2/High-temp$ composite solution with different particle ratios are investigated by rheometer, and the dispersion properties of the composite solution are confirmed by relaxation NMR and Turbiscan. The mechanical properties of 3D-printed objects are measured by a tensile test and nanoindenter. To investigate the aggregation and dispersion properties of VTES-coated $ZrO_2$ ceramic particles with different particle ratios, we observe the cross-sectional images of 3D printed objects using FE-SEM. The 3D printed objects of the composite solution with nano-particles of 80 % demonstrate improved mechanical characteristics.

Sensing characteristics of a non-dispersive infrared CO2 sensor using a Fabry-Perot filter based on distributed Bragg reflector (분산 반사경 기반 패브리-페로 필터를 이용한 비분산적외선 CO2 센서의 감지 특성)

  • Do, Nam Gon;Lee, Junyeop;Jung, Dong Geon;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.446-450
    • /
    • 2021
  • Non-dispersive infrared (NDIR) gas sensors typically use an optical filter that transmits a discriminating 4.26 ㎛ wavelength band to measure carbon dioxide (CO2), as CO2 absorbs 4.26 ㎛ infrared. The filter performance depends on the transmittance and full width at half maximum (FWHM). This paper presents the fabrication, sensitivity, and selectivity characteristics of a distributed Bragg reflector (DBR)-based Fabry-Perot filter with a simple structure for CO2 detection. Each Ge and SiO2 films were prepared using the RF magnetron sputtering technique. The transmittance characteristics were measured using Fourier-transform infrared spectroscopy (FT-IR). The fabricated filter had a peak transmittance of 59.1% at 4.26 ㎛ and a FWHM of 158 nm. In addition, sensitivity and selectivity experiments were conducted by mounting the sapphire substrate and the fabricated filter on an NDIR CO2 sensor measurement system. When measuring the sensitivity, the concentration of CO2 was observed in the range of 0-10000 ppm, and the selectivity was measured for environmental gases of 1000 ppm. The fabricated filter showed lower sensitivity to CO2 but showed higher selectivity with other gases.

A Study on Improvement of Submarine Attack Periscope Operation Performance using Installing Protector on Sail (잠수함 공격잠망경 함교 보호구조물 설치를 통한 장비 운용성능 향상에 관한 연구)

  • Choi, Woo-Seok;Chang, Ho-Seong;Lee, Young-Suk;Kim, Sang-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.199-206
    • /
    • 2021
  • This paper describes the feasibility and reliability verification of installing a protective structure to protect attack periscopes. The attack periscope is the critical equipment of a submarine to enable the user to monitor surface and air activity, collect navigational data, and detect and identify targets. The attack periscope provides target information acquired through TV, IR camera, and laser range finder to the combat system. In the product improvement program, the upper part of the masts was exposed to the outside of the sail because the existing attack periscope was replaced with a new one. On the other hand, the head sensor can be damaged by floating objects, such as fishing nets, during sea navigation. Therefore, the installation of a protective structure for an attack periscope improved the equipment operation performance. The feasibility and reliability of the installation of the protective structure were verified by examining the influence of URN.

Effects of Magnetic Therapy to Improve on Pain Threshold, Blood Flow, and Balance in Patient with Knee Osteoarthritis (자기장 치료법이 무릎 뼈관절염 환자의 통증 역치, 혈류량 및 균형능력에 미치는 영향)

  • Kyong-Hun Kim;Dong-Hoon Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose : This study was performed to evaluate the effects of magnetic therapy (MT) on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Methods : A single-blind, randomized controlled trial (RCT) was conducted with 30 patient with knee osteoarthritis. They were randomly allocated 2 groups; magnetic therapy group (MTG; n=15) and placebo magnetic therapy group (PG; n=15). The MTG group received 30 minutes magnetic therapy and 20 minute conservative physical therapy (Hotpack, ICT), magnetic therapy was conducted in magnetic therapy device (OM-100, NUGA, Korea). In the placebo magnetic group received 30 minutes placebo magnetic therapy and 20 minute conservative physical therapy. Each group performed 50 minutes a day 3 times a week for 8 weeks. The primary outcome pressure pain threshold test, blood flow, balance ability were measured by a pressure threshold meter (Commander algometer, JTECH medical, USA), laser dofler image (Moor LDI2-IR, Moor instruments, USA), balance measurement system (BioRescue, Marseille, France). The measurement were performed before and after the 8 weeks intervention period. Results : Both groups demonstrated significant improvement of outcome in pain threshold, blood flow, and balance ability during intervention period. magnetic therapy group revealed significant differences in pain threshold, blood flow, and balance as compared to the placebo magnetic therapy group groups (p<.05). Our results showed that magnetic therapy was more effective than placebo therapy on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Conclusion : Our findings indicate that magnetic therapy can improve pain threshold, blood flow, and Balance, highlight the benefits of magnetic therapy. This study will be able to be used as an intervention data for recovering pain threshold, blood flow, and balance in patients with knee osteoarthritis.

Developing the Automated Sentiment Learning Algorithm to Build the Korean Sentiment Lexicon for Finance (재무분야 감성사전 구축을 위한 자동화된 감성학습 알고리즘 개발)

  • Su-Ji Cho;Ki-Kwang Lee;Cheol-Won Yang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.1
    • /
    • pp.32-41
    • /
    • 2023
  • Recently, many studies are being conducted to extract emotion from text and verify its information power in the field of finance, along with the recent development of big data analysis technology. A number of prior studies use pre-defined sentiment dictionaries or machine learning methods to extract sentiment from the financial documents. However, both methods have the disadvantage of being labor-intensive and subjective because it requires a manual sentiment learning process. In this study, we developed a financial sentiment dictionary that automatically extracts sentiment from the body text of analyst reports by using modified Bayes rule and verified the performance of the model through a binary classification model which predicts actual stock price movements. As a result of the prediction, it was found that the proposed financial dictionary from this research has about 4% better predictive power for actual stock price movements than the representative Loughran and McDonald's (2011) financial dictionary. The sentiment extraction method proposed in this study enables efficient and objective judgment because it automatically learns the sentiment of words using both the change in target price and the cumulative abnormal returns. In addition, the dictionary can be easily updated by re-calculating conditional probabilities. The results of this study are expected to be readily expandable and applicable not only to analyst reports, but also to financial field texts such as performance reports, IR reports, press articles, and social media.

Characteristics of Heavy Metal Oxide Glasses in BaO-GeO2-La2O3-ZnO-Sb2O3 System for Infrared Lens (적외선 렌즈용 BaO-GeO2-La2O3-ZnO-Sb2O3계 중금속 산화물 유리의 특성)

  • Sang-Jin Park;Bok-Hyun Oh;Sang-Jin Lee
    • Korean Journal of Materials Research
    • /
    • v.33 no.10
    • /
    • pp.414-421
    • /
    • 2023
  • Infrared radiation (IR) refers to the region of the electromagnetic radiation spectrum where wavelengths range from about 700 nm to 1 mm. Any object with a temperature above absolute zero (0 K) radiates in the infrared region, and a material that transmits radiant energy in the range of 0.74 to 1.4 um is referred to as a near-infrared optical material. Germanate-based glass is attracting attention as a glass material for infrared optical lenses because of its simple manufacturing process. With the recent development of the glass molding press (GMP) process, thermal imaging cameras using oxide-based infrared lenses can be easily mass-produced, expanding their uses. To improve the mechanical and optical properties of commercial materials consisting of ternary systems, germanate-based heavy metal oxide glasses were prepared using a melt-cooling method. The fabricated samples were evaluated for thermal, structural, and optical properties using DSC, XRD, and XRF, respectively. To derive a composition with high glass stability for lens applications, ZnO and Sb2O3 were substituted at 0, 1, 2, 3, and 4 mol%. The glass with 1 mol% added Sb2O3 was confirmed to have the optimal conditions, with an optical transmittance of 80 % or more, a glass transition temperature of 660 ℃, a refractive index of 1.810, and a Vickers hardness of 558. The possibility of its application as an alternative infrared lens material to existing commercial materials capable of GMP processing was confirmed.

Preparation and Characterization of O-Carboxymethyl Chitosan Ion-complexed Poly(L-Lysine) for Drug and Gene Delivery System (약물 및 유전자 전달체로 응용하기 위한 Poly(L-Lysine)이 결합된 O-Carboxymethyl Chitosan PEG의 제조와 특성)

  • Nam, Joung-Pyo;Kim, Young-Min;Park, Jin-Su;Lee, Eung-Jae;Choi, Chang-Yong;Jang, Mi-Kyeong;Nah, Jae-Woon
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.643-647
    • /
    • 2010
  • O-carboxymethyl water-soluble chitosan (OCMCh) prepared for enhance the application of chitosan was modified with mthoxy polyethyleneglycol (mPEG) by ion-complex for long circulation in the blood. OCMCh-PEG-PLLs was prepared by forming ion-complex with OCMCh-PEG and Poly(L-Lysine) (PLL) for drug and gene delivery system. The physicochemcal characterisitcs of OCMCh-PEG-PLLs were investigated by FT-IR, $^1H$-NMR. These results showed that CMCh-PEG-PLLs were successfully syntehsized by ion-complex. Particle size distribution and zeta potential of the OCMCh-PEG-PLLs were determined using dynamic light scattering technique. Transmission electron microscopy (TEM) was also used to observe the morphology of the OCMCh-PEG-PLLs. OCMCh-PEG-PLLs have spherical shapes with particle size 290∼390 nm. OCMCh-PEG-PLLs were showed when the feeding amount of mPEG ratio was increased, particle size and zeta potential were decreased. Based on these results, it is possible to introduction of the OCMCh-PEG-PLLs into various biomedical fields such as drug and gene delivery system.

Interaction of Pseudostellaria heterophylla with Quorum Sensing and Quorum Quenching Bacteria Mediated by Root Exudates in a Consecutive Monoculture System

  • Zhang, Liaoyuan;Guo, Zewang;Gao, Huifang;Peng, Xiaoqian;Li, Yongyu;Sun, Shujing;Lee, Jung-Kul;Lin, Wenxiong
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.12
    • /
    • pp.2159-2170
    • /
    • 2016
  • Many plant-pathogenic bacteria are dependent on quorum sensing (QS) to evoke disease. In this study, the population of QS and quorum quenching (QQ) bacteria was analyzed in a consecutive monoculture system of Pseudostellaria heterophylla. The isolated QS strains were identified as Serratia marcescens with SwrIR-type QS system and exhibited a significant increase over the years of monoculture. Only one QQ strain was isolated from newly planted soil sample and was identified as Bacillus thuringiensis, which secreted lactonase to degrade QS signal molecules. Inoculation of S. marcescens to P. heterophylla root could rapidly cause wilt disease, which was alleviated by B. thuringiensis. Furthermore, the expression of lactonase encoded by the aiiA gene in S. marcescens resulted in reduction of its pathogenicity, implying that the toxic effect of S. marcescens on the seedlings was QS-regulated. Meanwhile, excess lactonase in S. marcescens led to reduction in antibacterial substances, exoenzymes, and swarming motility, which might contribute to pathogensis on the seedlings. Root exudates and root tuber extracts of P. heterophylla significantly promoted the growth of S. marcescens, whereas a slight increase of B. thuringiensis was observed in both samples. These results demonstrated that QS-regulated behaviors in S. marcescens mediated by root exudates played an important role in replanting diseases of P. heterophylla.

Improvement of Cloud-data Filtering Method Using Spectrum of AERI (AERI 스펙트럼 분석을 통한 구름에 영향을 받은 스펙트럼 자료 제거 방법 개선)

  • Cho, Joon-Sik;Goo, Tae-Young;Shin, Jinho
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.137-148
    • /
    • 2015
  • The National Institute of Meteorological Research (NIMR) has operated the Fourier Transform InfraRed (FTIR) spectrometer which is the Atmospheric Emitted Radiance Interferometer (AERI) in Anmyeon island, Korea since June 2010. The ground-based AERI with similar hyper-spectral infrared sensor to satellite could be an alternative way to validate satellite-based remote sensing. In this regard, the NIMR has focused on the improvement of retrieval quality from the AERI, particularly cloud-data filtering method. The AERI spectrum which is measured on a typical clear day is selected reference spectrum and we used region of atmospheric window. We performed test of threshold in order to select valid threshold. We retrieved methane using new method which is used reference spectrum, and the other method which is used KLAPS cloud cover information, each retrieved methane was compared with that of ground-based in-situ measurements. The quality of AERI methane retrievals of new method was significantly more improved than method of used KLAPS. In addition, the comparison of vertical total column of methane from AERI and GOSAT shows good result.