Study on Infrared Signature Variations of a Naval Ship Operated at sea Near Geoje-do Island (거제도 인근해상에서 운용되는 함정의 적외선 신호 변화 특성에 대한 연구)

  • Kil, Tae-Jun;Kim, Tae-Kuk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.15-24
    • /
    • 2014
  • It is essential to understand the infrared signature of a naval ship to survive against various missile attacks under variable environmental conditions. As guided missiles are developing to equip more accurate IR seekers, research works for countermeasure and IR stealth technology are strongly required. But challenging works are continuously suggested for predicting and analyzing IR signal status of naval ships to achieve low observable performance under various weather conditions, variable missions and developing threats. In this study, overall guidelines of setting design criteria for low observable ships are proposed by considering varying environmental conditions including daily and seasonal variations. Test and evaluation criteria for newly constructed ships for target and background temperature difference is proposed as a design criteria which can be predicted by change of condition and ship's speed. Through the proposed techniques and procedures, it is expected to establish the measurement and evaluation criteria by using temperature, IR Signal differences between the ship and the background.

Design and Fabrication of K-band multi-channel receiver for short-range RADAR (근거리 레이더용 K대역 다채널 전단 수신기 설계 및 제작)

  • Kim, Sang-Il;Lee, Seung-Jun;Lee, Jung-Soo;Lee, Bok-Hyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.7A
    • /
    • pp.545-551
    • /
    • 2012
  • In this paper, K-band multi-channel receiver was designed and fabricated for low noise amplification and down conversion to L-band. The fabricated multi-channel receiver incorporates GaAs-HEMT LNA(Low noise amplifier) which provides less than a 2 dB noise figure, IR(Image Rejection) Filter for rejection of image frequency, IR(Image rejection) mixer to reject a image frequency and improve an IMD(Intermodulation Distortion) characteristic. Test results of the fabricated multi-channel receiver show less than a 3.8 dB noise figure, conversion gain of more than 27dB, and IP1dB(Input 1dB Gain Compression Point) of -9.5 dB and over.

A Feasibility Study on the Probabilistic Method for the Naval Ship Infra-red Signature Management (함정적외선신호 관리를 위한 확률론적 방법의 가능성 연구)

  • Park, Hyun-jung;Kang, Dae-soo;Cho, Yong-jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.5
    • /
    • pp.383-388
    • /
    • 2019
  • It is essential to reduce the Infra-red signature for increasing ship's survivability in ship design stage. However the ship's IR signature is quite sensitive to the maritime and atmosphere. Therefore, it is very important to select the marine meteorological data to be applied to the signature analysis. In this study, we selected the three meteorological sample sets from the population of the Korea Meteorological Administration's marine environment data in 2017. These samples were selected through the two-dimensional stratified sampling method, taking into account the geopolitical threats of the Korean peninsula and the effective area of the buoy. These sample sets were applied to three naval ships classified by their tonnage, and then the IR signature analysis was performed to derive the Contrast Radiant Intensity (CRI) values. Based on the CRI values, the validity of each sample set was determined by comparing Cumulative Distribution Function (CDF), and Probability Density Function (PDF). Also, we checked the degree of scattering in each sample set and determined the efficiency of analysis time and cost according to marine meteorological sample sets to confirm the possibility of a probabilistic method. Through this process, we selected the standard for optimization of marine meteorological sample for ship IR signature analysis. Based on this optimization sample, by applying probabilistic method to the management of IR signature for naval ships, the robust design is possible.

Measurement and Validation of Infrared Signature from Exhaust Plume of a Micro-Turbo Engine (마이크로 터보 엔진 배기 플룸에서의 적외선 신호 측정 및 검증)

  • Gu, Bonchan;Baek, Seung Wook;Jegal, Hyunwook;Choi, Seongman;Kim, Won Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1054-1061
    • /
    • 2016
  • Development of an accurate infrared signature (IR) measurement system is expected to contribute in the development of low observable technology and the spectroscopic analysis of electromagnetic radiation. Application of a spectroradiometer (SR) allows for the measurement of detailed infrared signature from the exhaust plume due to its own heat source. Establishment of a measurement system using a micro-turbo engine is intended to simulate the modelling of the aircraft plume. The engine was installed on a test stand to measure the engine performance. The IR signature was measured by placing the SR perpendicular to the axis line of the exhaust plume. Reference data from the blackbody were also measured to calibrate the raw data, and the infrared signature of the background was also measured for comparison with that of the plume. The calibrated spectral radiance was obtained through the data reduction process and the results were analyzed in specific bands. The experiments revealed that the measurement system established here showed sufficient performance for further comprehensive analysis.

Study on the IR Measurement Scheme and Requirement for Its Evaluation from a Naval ship Considering the Meteorological Conditions (기상 조건에 따른 함정의 적외선 방사신호 성능 평가시 고려요소 및 계측 방안 연구)

  • Gil, Tae-Jun;Cho, Yong-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.4
    • /
    • pp.459-465
    • /
    • 2007
  • This paper deals with the development of measuring methodology and the requirement for its evaluation of the infrared radiation from a naval ship to optical sensors, considering the Meteorological conditions. Factors required for measuring the apparent temperature and infrared radiation are identified and two methods are suggested based on the measuring instruments carried by ship or aircraft. and target operation in the Meteorological conditions is considered. This study describes some factors affecting the IR signature. required instruments to obtain the IR signal considering the naval ship.

The Study of Solid Propellant to Reduce Infrared Signature (적외선(IR, Infrared) 신호가 감소된 고체추진제 개발)

  • Lee, Jongseop;Yim, Yoojin;Park, Euiyong;Han, Houkseop
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.4
    • /
    • pp.42-48
    • /
    • 2013
  • In this paper, a study of solid rocket propellant formulation is performed to suppress plume and reduce IR(infrared) signature which occurs in propellant combustion. The solid propellant to enhance the stealthy ability was formulated in terms of the kinds and the effects of afterburning suppressant on the ballistic performance and the amount of primary smoke. In addition, substantial decrease in plume and IR signature is confirmed by static firing test by a 4 inch standard motor.

Smart watch with reflective Pulse Oximeter (반사형 Pulse Oximeter를 통한 스마트 손목시계)

  • Lee, Hooseok;Thap, Tharoeun;Moon, Chanki;Nam, Yunyoung;Lee, Jinseok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.1046-1048
    • /
    • 2015
  • 본 논문은 웨어러블 디바이스의 한 종류로써의 스마트와치에 적용할 수 있는 헬스케어 기술에 대한 제안이다. RED LED와 IR LED를 통해 얻어진 신호로부터 아날로그 필터 증폭을 통해 얻어진 PPG신호를 이용하여 생체신호인 심박수와 $SpO_2$를 측정하여 보았다. 이 신호를 블루투스 통신을 통해 PC에서 데이터를 받아 보았고, 추후에 스마트폰과 연동하여 실용적으로 사용 될 수 있다.

Multiple Access Scheme Using Modified Hermite Polynomial Pulse and Ternary code for Out-Body WBAN (신체 외부 통신에서 MHP 펄스와 터너리 코드를 이용한 다중접속 기법)

  • Shim, Jae-Joon;Hwang, Jae-Ho;Kim, Jae-Moung
    • Journal of Internet Computing and Services
    • /
    • v.12 no.1
    • /
    • pp.27-38
    • /
    • 2011
  • In this paper, we propose a multiple access scheme using MHP(Modified Hermite Polynomial) pulse and ternary code for high-data and low-data rate for Out-body WBAN(Wireless Body Area Network). To satisfy the requirement of WBAN system, UWB-IR has been considered as a promising candidate for Out-body WBAN. The proposed multiple access scheme, using orthogonal MHP pulse and ternary code sets, reduces multi-user interference and distinguishes user signal from multi-user signals. We propose two algorithms for synchronous and asynchronous WBAN system. The symbol is constructed by MHP pulses and time hopping duration to reduce multi-user interference in the synchronous WBAN system. The symbol also is constructed by ternary code to avoid collision between pulse trains in the asynchronous WBAN system. The results of the proposed multiple access scheme show a clear improvement of BER.

A Threshold Estimation Algorithm for a Noncoherent IR-UWB Receiver Using 1-bit Sampler (1-bit 샘플러를 사용한 비동기식 IR-UWB 수신기의 임계값 추정 알고리즘)

  • Lee, Soon-Woo;Park, Young-Jin;Kim, Kwan-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.8
    • /
    • pp.17-22
    • /
    • 2007
  • In this paper, we propose a threshold estimation algorithm for a noncoherent IR-UWB receiver using 1-bit sampler. The proposed method reduces the hardware complexity by using the information of binary data resulted from 1-bit sampler instead of measuring the energy level of a received signal. Besides, mathematical modeling shows that the performances are similar to those of theoretically optimal threshold in terms of bit error rate. Computer simulations based on the IEEE 802.15.4a channel model also demonstrate the superiority of the proposed algorithm.

OES based PECVD Process Monitoring Accuracy Improvement by IR Background Signal Subtraction from Emission Signal (적외선 배경신호 처리를 통한 OES 기반 PECVD공정 모니터링 정확도 개선)

  • Lee, Jin Young;Seo, Seok Jun;Kim, Dae-Woong;Hur, Min;Lee, Jae-Ok;Kang, Woo Seok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.1
    • /
    • pp.5-9
    • /
    • 2019
  • Optical emission spectroscopy is used to identify chemical species and monitor the changes of process results during the plasma process. However, plasma process monitoring or fault detection by using emission signal variation monitoring is vulnerable to background signal fluctuations. IR heaters are used in semiconductor manufacturing chambers where high temperature uniformity and fast response are required. During the process, the IR lamp output fluctuates to maintain a stable process temperature. This IR signal fluctuation reacts as a background signal fluctuation to the spectrometer. In this research, we evaluate the effect of infrared background signal fluctuation on plasma process monitoring and improve the plasma process monitoring accuracy by using simple infrared background signal subtraction method. The effect of infrared background signal fluctuation on plasma process monitoring was evaluated on $SiO_2$ PECVD process. Comparing the $SiO_2$ film thickness and the measured emission line intensity from the by-product molecules, the effect of infrared background signal on plasma process monitoring and the necessity of background signal subtraction method were confirmed.