• 제목/요약/키워드: IPS Empress ingot

검색결과 11건 처리시간 0.021초

재 사용된 IPS-empress ingot의 pressing accuracy에 관한 연구 (A STUDY ON THE PRESSING ACCURACY OF THE REUSED IPS-EMPERESS INGOT)

  • 송병권;박현배;오상천;진태호
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.357-364
    • /
    • 1997
  • IPS-empress system is one of widely used all ceramic system. The purpose of this study was to determine the pressing accuracy of reused IPS%Empress ingot. 10 specimens were made using new ingot first, and using the rests of the specimen the another group of specimens were made next. finally, the third group of specimens were made with same procedure mentioned above. The results obtained in this study were as follows ; 1. The pressing accuracy of the first group of specimen was 96.1%, that of the second group was 95.4%, and that of the third group was 95.4%. There was no statistical significance among them, that is, the reuse of the IPS-Empress ingot did not influence on the pressing accuracy. 2. the common site of the defect in pressed ingot was central area at the margin opposite of sprue hole.

  • PDF

반복 사용된 IPS Empress 2의 표면경도와 pressing accuracy에 관한 연구 (SURFACE HARDNESS AND PRESSING ACCURACY OF REUSED IPS EMPRESS 2)

  • 손외수;김유리;이경자;진태호
    • 대한치과보철학회지
    • /
    • 제41권5호
    • /
    • pp.596-605
    • /
    • 2003
  • Statement of problem : IPS Empress2 system was developed and used in prosthodontic treatment, but the cost of ingot is expensive for wide application. Purpose : This study was to investigate the possibility on recycling of IPS Empress 2 ceramic for wide application of IPS Empress 2 ceramic in prosthodontic treatment. Material and Method : 1st, 2nd and 3rd pressed disc-shaped($10{\times}1.5mm$) IPS Empress 2 specimens were made with IPS Empress ingot(200, Ivoclar, Liechtenstein) and pressing furnace(IPS Empress EP 500, Ivoclar, Liechtenstein). Vicker's surface hardness and fracture toughness, acid resistance, and pressing accuracy of IPS Empress 2 ceramic were measured and analyzed. Surface hardness was measured by microhardness tester(MTX 70. Matsuzawa, Japan), before and after surface treatment with 0.5% hydrofluoric acid and carbonic acid(Coca cola) for evaluation of acid resistance. Results : The surface hardness of 1st pressed specimen was the higher(5.11 GPa) than those of 2nd pressed(4.89 GPa) and 3rd pressed specimen(4.86 GPa), and the fracture toughness of 1st pressed ($1.58MPam^{1/2}$) and 2nd pressed specimen($1.51MPam^{1/2}$) were higher than that of 3rd pressed specimen($1.39MPam^{1/2}$). The changes of surface hardness of 1st, 2nd, and 3rd pressed specimens after treatment with fluoric acid were 0.17, 0.06, 0.05 (GPa) respectively, and those of 1st, 2nd, and 3rd pressed specimens after treatment with carbonic acid were 0.07, 0.00, 0.05(MPa) respectively. The pressing accuracy of 1st,2nd and 3rd specimen were 77.22%, 85.681%, and 75.05%. The pressing accuracy of 2nd pressed specimen was higher than that of the 3rd specimen. Conclusion : The changes of physical properties according to recycling of IPS Empress 2 from this study were insignificant. Therefore the possibility of recycling of IPS Empress 2 can be suggested from the results.

다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향 (Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots)

  • 양미선;김석규
    • 대한치과보철학회지
    • /
    • 제49권4호
    • /
    • pp.308-315
    • /
    • 2011
  • 연구 목적: IPS Empress Esthetic$^{(R)}$ system의 ingot은 다양한 반투명도를 가지고 있지만, 실제 다양한 색조의 자연치를 배경으로 각각의 ingot을 laminate veneer로 제작했을 때 어느 정도의 차폐능력을 나타내는지 알 수 없다. 본 연구의 목적은 반투명도가 서로 다른 ingot으로 제작한 IPS Empress Esthetic$^{(R)}$ laminate veneer 수복 시 다른 색상의 지대치상에서 최종 색조의 차이(color difference, ${\Delta}E$)를측정, 분석해서 그 차폐효과를 평가하고, 최종 색조에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: Laminate veneer 수복을 위해 삭제된 6가지 다른 색조(A1, A3, A4, B2, B3, C3)의 자연치아 위에 반투명도가 서로 다른 6가지 IPS Empress Esthetic$^{(R)}$ ingot (E 01, E 03, E OC1, E TC1, E TC2, E TC3)으로 제작된 총 두께 0.6 mm의 도재 시편들을 translucent shade의 시적용 합착제로 시적한 뒤 각 시편 조합의 색조를 색채계(colorimeter)를 이용하여 측정하였다. 서로 다른 색조의 지대치아 위에서 측정된 도재시편들의 색차를 비교, 분석하였다. 결과: 지대치 색조 및 coping의 반투명도에 따라서 laminate veneer 수복물의 최종 색조가 다르게 나타났다(P<.05). 모든 도재 시편에서 A3, B3, 그리고 C3 shade를 가진 지대치들 사이의 평균 색차값(${\Delta}E$)이 2.7 이하로 나타났고, 지대치들 간의 색조가 A3 와 A4, B3 와 A4, 그리고 C3 와 A4 인 경우 평균 색차값은 몇 가지 도재 시편에서 2.7 이하를 나타내어 laminate veneer 수복물에 의한 지대치 색조의 차폐효과를 보여 주었다. 반면, A1 과 B2 shade의 지대치는 다른 지대치들과 비교하여 높은 색조 차이를 보였으며, 특히A4와 B2, A3 와 B2, 그리고 A1 과 A4 색조의 지대치들 사이에는 그 색조 차이가 컸다. 결론: IPS Empress Esthetic$^{(R)}$ coping으로 제작된 laminate veneer의 최종 색조는 지대치 색조 및 coping의 반투명도에 의해 영향을 받았다. 서로 다른 $a^*$$b^*$ 값을 나타내는 지대치들의 색상 차이는 어느 정도 차폐 되는 효과를 보여주고 있으나, 명도($L^*$)의 차이가 많이 나타나는 지대치 색조들을 차폐하는 것은 한계가 있었다.

주입선 및 열처리에 따른 IPS Empress 도재의 미세구조에 관한 연구 (A STUDY ON THE MICROSTRUCTURE OF IPS EMPRESS CERAMICS ACCORDING TO THE HEAT TREATMENT AND SPRUE TYPE)

  • 동진근;오상천
    • 대한치과보철학회지
    • /
    • 제36권5호
    • /
    • pp.772-785
    • /
    • 1998
  • This study was undertaken to clarify the microstructure of the different IPS Empress ingots by etching and to observe the change of leucite crystal structure according to subsequent heat treatment and the crystal distribution according to sprue types(${\phi}2.8mm$, single sprue; ${\phi}1.8mm$, double sprue) by scanning electron microscopy. IPS Empress T1, O1 ingots used for staining technique, and Dentin(A2) ingots used for layering technique were selected for this study. To observe the microstructures of these ingots before pressing, the specimens were prepared in splinters($3{\times}3{\times}3mm$) taken from the original ingots. And to estimate crystal distribution and microstructural change by sprue type and subsequent heat treatment. the specimens($3{\times}3{\times}3mm$) were heat-pressed through the two types of sprues with different diameters and numbers, and all specimens were fired according to the recommended firing schedule. The observed surface was ground with waterproof papers($#800{\sim}#1800$) on the grind polisher and was cleaned ultrasonically. All specimen were etched with 0.5% hydrofluoric acid. After etching, the surface was treated by ion sputter coating for SEM observation at an accelerating voltage of 20kV. In all specimens, the central area of ground surface was observed because there was less difference in microstructure between the peripheral area and the central area. The results were as follows ; 1. In the microstructure according to the ingot type, there was a wide difference between the staining (T1,O1) and layering(Dentin A2) ingots, but there was not a considerable difference between the T1 ingot and the O1 ingot for staining technique. 2. In all specimens, the crystal dispersion of IPS Empress ceramic using double sprue was significantly more scattered than that of IPS Empress ceramic using single sprue. The degree of scattering was strongest in the Dentin(A2) specimen and weakest in the O1 ingot. 3. In the microstructural change according to the subsequent heat treatment, all of ingots had some microcracks in the inside of the leucite crystal and the glass matrix after pressing. The inner splinters of the leucite crystal became smaller, and more microcracks occurred in the glass matrix due to increasing heat treatment times. 4. The size of leucite crystals varied from $1{\mu}m\;to\;5{\mu}m$. The mean size of mature crystals was about $5{\mu}m$. The form of the crystal was similar to a circle when it was smaller and similar to an ellipse when it was larger.

  • PDF

반복 사용된 IPS Empress 2의 굽힘강도와 색변화에 관한 연구 (FLEXURE STRENGTH AND COLOR CHANGE OF REUSED IPS EMPRESS 2)

  • 송영국;김유리;김성훈;안희영;진태호
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.71-80
    • /
    • 2003
  • Development of new ceramic and esthetic need of patient increased the use of ceramic restorations. The purpose of this study was to confirm the possibility of recycling for IPS Empress2 which has a lot of advantages in esthetics. 1st, 2nd and 3rd pressed disc-shaped($10{\times}1.5mm$) IPS Empress 2 specimens were made with IPS Empress ingot(shade 200, Ivoclar, Liechtenstein) and pressing furnace(IPS Empress EP 500, Ivoclar, Liechtenstein). Flexure strength was measured with universal testing machine(Zwick 145641, Zwick, Germany), and color change and staining resistance of specimens were evaluated with colorimeter (Model TC-6FX, Tokyo Denshoku Co., Japan). The followings were drawn from this study : 1. Flexure strength of the 1st, the 2nd, and the 3rd pressed specimens showed 236.78 MPa. 247.16MPa, and 220.72MPa, respectively. Flexure strength of the 2nd pressed specimens was higher than others, but there's no statistical difference between them. 2. The color difference between the 1st and the 2nd pressed specimens was 3.25, and that between the 1st and the 3rd pressed specimens was 3.63(P<0.05). 3. The color change after staining of the 1st, the 2nd. and the 3rd pressed specimens were 1.43, 2.64, and 1.45, respectively. In this study, reused IPS Empress 2 specimens showed insignificant change of flexure strength and stain resistance, but they showed some color change according to reuse. From this results, the limited possibility of reuse for IPS Empress 2 could be considered.

MECHANICAL PROPERTIES OF REUSED LITHIUM DISILICATE GLASS-CERAMIC OF IPS EMPRESS 2 SYSTEM

  • Oh Sang-Chun
    • 대한치과보철학회지
    • /
    • 제40권6호
    • /
    • pp.572-576
    • /
    • 2002
  • This investigation was designed to estimate the biaxial flexure strength and fracture toughness of lithium disilicate glass-ceramics of IPS Empress 2 system pressed with as-received ingots and their sprue buttons. Two groups of the lithium disilicate glass-ceramics were prepared as follows: group 1 is ingot-pressed group; group 2 is sprue button-pressed group. A ball-on-three-ball test was used to determine biaxial flexure strength (BFS) of disks in wet environment. Scanning electron microscopy(SEM) analysis was conducted to observe the microstructure of the ceramics. Unpaired t-test showed that there were no differences in the mean biaxial Hem strength (BFS) and KIC values between group 1 and 2 (p > 0.05). Two groups showed similar values in the KIC and the strength at 5% failure probability. The SEM micrographs of the IPS Empress 2 glass-ceramic showed a closely packed, multi-directionally interlocking pattern of numerous lithium disilicate crystals protruding from the glass matrix. The lithium orthophosphate crystals could not be observed on the fracture surface etched. There was no a marked difference of the microstructure between group 1 and 2. Although there were no tests including color stability, casting accuracy, etc., the results of this study implied that we could reuse the sprue button of the pressed lithium disilicate glass-ceramic of IPS Empress 2 system.

수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향 (INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS)

  • 복원미;최근배;박찬운;안승근
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.

주입선 설계에 따른 Heat-pressed ceramic의 파절강도에 관한 연구 (A STUDY ON THE FLEXURAL STRENGH OF HEAT-PRESSED CERAMICS ACCORDING TO SPRUE DESIGNS)

  • 오상천;동진근
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.130-143
    • /
    • 1997
  • A heat-pressed technique(IPS-Empress, Ivoclar) has been described to construct single unit crown, inlay/onlay and veneers using a partially pre-cerammed and pre-colored glass-leucite ingot that has the greateast strength by the combination of heat-pressed procedure through the smalldiameter sprue and heat treatment procedure. The purpose of this study was to evaluate the flexure strength of a heat-pressed ceramic material(IPS-Empress) without simulated firing treatments according to pontic designs. Two groups of 9 disks(1.4mm thick, 14mm in diameter) each using two types of sprues with different diameters($({\Phi}2.8\;,{\Phi}1.8)$) and numbers were prepared. The specimens were mounted in the testing jig. The flexural strengths were determined, by means of the bi-axial bending test, by loading the center of disk to failure using a universal testing machine(Zwick 145141, Zwick, Germany) at a cross-head speed of 1.0 mm/min. The means flexural strength value of one group using a sprue with ${\Phi}2.8$ was $140.4{\pm}8.0Mpa$. That of the other group using two sprues with ${\Phi}1.8$ was $151.8{\pm}10.3Mpa$. After analysis, results showed that there was a statistical difference between groups(t=2.33m p<0.05). No clnical implications were drawn from these data because of absence of simulated firing treatment.

  • PDF

임시접착 후, 치면세마에 따른 Lithium Disilicate Glass-Ceramic의 레진결합강도에 대한 연구 (Resin Bond Strength of Lithium Disilicate Glass-Ceramic by Surface Cleansing Method after Temporary Cementation)

  • 정승화;이진한;오상천
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.259-268
    • /
    • 2007
  • purpose: This study was to evaluate the shear bond strength of Lithium Disilicate Glass-Ceramic by removable method of temporary cement on the abutment tooth. Material and Method: Sixty molar teeth of human with the occlusal surface up were mounted in acrylic resin blocks. The 45 specimens were prepared to exposure dentin by diamond bur and the eugenol-containing temporary cement($Cavitec^{TM}$ ($KERR^{(R)}$, U.S.A)was applied to the dentin surfaces. After initial removal of the cement with a dental explorer, the specimens were divided into 4 groups of 15 specimens each. The dentin surfaces of the specimens were treated by rotary instrument with as follow pastes: $Zircate^{(R)}$ prophy paste(Dentsply, U.S.A), Radent Prophy Paste(Pascal company,inc. U.S.A), and Dental pumice(Wip mix corporation,U.S.A). An adhesive resin luting agent(Variolink $II^{(R)}$, Ivoclar Vivadent, Leichtenstein) including Monobond-S and $Excite^{(R)}$ was applied to all specimens. The ceramic specimens were made with an A1 ingot of IPS Empress $II^{(R)}$ (Ivoclar Vivadent, Leichtenstein). After the specimens were stored in distilled water for 48hr, the shear bond strength(MPa) was measured by a Universal testing machine(Zwick 145641, Zwick, Germany) at a 1mm/min cross-head speed. The data were statistically analyzed by one-way ANOVA and Duncan's multiple range test. Results: In all group, there were no significant differences in comparison with the control group(p>0.05). The pattern of most failure showed the mixed type of cohesive and adhesive failure. Conclusion: Resin bond strength of IPS Empress $II^{(R)}$ was not affected by removal method of the temporary cement.

금속선 강화에 따른 열 가압 도재의 파절저항 (The fracture resistance of heat pressed ceramics with wire reinforcement)

  • 조득원;동진근;오상천;김유리
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.191-198
    • /
    • 2009
  • 연구목적: 본 연구는 높은 심미성을 나타내지만 낮은 파절 강도로 인하여 구치부에서의 사용이 제한되고 있는 전부도재 고정성 국소의치의 파절강도를 증가시키기 위한 방법으로, 취성 재료인 도재에 인장강도가 높은 금속선을 삽입하고 물리적, 기계적 성질을 알아보고자 하였다. 연구 재료 및 방법: lithium disilicate(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Lichtenstein)와 0.41 mm 직경의 Ni-Cr 금속선(Alfa Aesar, Johnson Matthey Company, USA)을 사용하여, 금속선의 수와 배열을 달리한 4개의 실험군 시편을 제작하였다. 모든 시편은 폭 4 mm, 두께 2 mm, 길이 15 mm의 직육면체로 제작하였다. 실험군 1, 2, 3은 각각 한 가닥, 두 가닥, 세 가닥의 금속선을 도재 시편의 장축을 따라 배열하였으며, 실험군 4는 세 가닥의 금속선을 도재 시편의 장축에, 다섯 가닥의 금속선을 도재 시편의 횡축에 배열하였다. 대조군에는 금속선을 삽입하지 않았으며, 대조군 및 각각의 실험군의 시편은 각 군당 12개로 하였다. 결과: 만능 시험기(Z020, Zwick, Germany)를 이용하여 파절시점까지 하중을 가한 후, 굴곡계수, 굴곡강도, 파절시점까지의 변형률, 파괴인성을 측정하였다. 파절된 시편의 도재와 금속선의 계면을 횡절단 및 연마하여 주사전자현미경(JSM-6360, JEOL, Japan)으로 100배상에서 관찰하였다. 결과는 다음과 같다. 1. 도재에 금속선을 삽입한 결과, 금속선을 삽입하지 않은 대조군에 비해 통계적 유의성 있는 굴곡계수 및 굴곡강도의 변화는 관찰할 수 없었으나, 변형률의 유의성 있는 증가(P<.001)를 관찰할 수 있었다. 2. 금속선을 삽입한 시편의 파절 양상은 하중점 부위에서 도재만 파절되는 양상을 나타내었다. 3. 금속선을 삽입한 도재의 파절된 시편을 횡절단 및 종절단하여 100 배상에서 주사전자현미경으로 촬영한 결과, 하중 시 도재의 파절 원인이 될 수 있는 도재 내부의 기포는 관찰되지 않았으며, 도재와 금속선 사이의 gap도 관찰되지 않았다. 결론: 금속선 삽입의 결과, 취성 재료인 도재의 통계적으로 유의성 있는 변형률의 증가를 관찰할 수 있었다. 그러나 구치부에서 금속선 강화 도재의 사용을 위해서는 굴곡계수 및 굴곡강도의 향상이 필요하다. 이를 위해서는 추가적 연구가 필요하다.