• Title/Summary/Keyword: IPCC Guideline

Search Result 64, Processing Time 0.028 seconds

A Study on the Greenhouse Gas Emission and Reduction Measures of Domestic Magnesium Production Process (국내 마그네슘 생산공정의 온실가스 배출량 산정 및 감축방안 연구)

  • Kim, Kyung-Nam;Im, Jin-Ah;Yoo, Kyung-Seun
    • Journal of Climate Change Research
    • /
    • v.5 no.3
    • /
    • pp.219-230
    • /
    • 2014
  • In this study, greenhouse gas emission of magnesium industry was estimated and the reduction potential of the greenhouse gas emission was evaluated with reduction technologies. Default value of IPCC guideline was used to calculate the greenhouse gas emission and $SF_6$ alternatives were considered in reduction potential. Import of magnesium ingot was 22,806 ton in 2013, which will be expected to increase to 81,700 ton with 20% rate in 2020. Magnesium ingot was consumed to produce magnesium alloy in diecasting process. Recently, commercial production of crown magnesium and magensium plate began. Based on ingot consumption, $CO_2$ emission of domestic magnesium industry was estimated to 504,000 ton, which is about 0.79% of domestic industrial emissions. Reduction potential of diecasting process was estimated to 489,320 ton by changing SF6 to alternative gases such as HFC-134a, Novec-612. Emission factor of Tier 3 level should be developed to enhance the accuracy of greeenhouse gas emission of magnesium industry.

Carbon and Nitrogen Stocks of Trees and Soils in a 'Niitaka' Pear Orchard ('신고'배 재배지 내 수체 및 토양의 탄소 및 질소 저장량)

  • Lee, Tae-Kyu;Choi, Jang-Jeon;Kim, Jong-Sung;Lee, Han-Chan;Ro, Hee-Myong
    • Horticultural Science & Technology
    • /
    • v.31 no.6
    • /
    • pp.828-832
    • /
    • 2013
  • To report country-specific carbon and nitrogen stocks data in a pear orchard by Tier 3 approach of 2006 IPCC guidelines for national greenhouse gas inventories, an experimental pear orchard field of the Pear Research Station, National Institute of Horticultural & Herbal Science, Rural Development Administration, Naju, Korea ($35^{\circ}01^{\prime}27.70N$, $126^{\circ}44^{\prime}53.50^{\prime\prime}E$, 6 m altitude), where 15-year-old 'Niitaka' pear (Pyrus pyrifolia Nakai cv. Niitaka) trees were planted at a $5.0m{\times}3.0m$ spacing on a Tatura trellis system, was chosen to assess the total amount of carbon and nitrogen stocks stored in the trees and orchard soil profiles. At the sampling time (August 2012), three trees were uprooted, and separated into six fractions: trunk, main branches, lateral branches (including shoots), leaves, fruits, and roots. Soil samples were collected from 0 to 0.6 m depth at 0.1 m intervals at 0.5 m from the trunk. Dry mass per tree was 4.7 kg for trunk, 13.3 kg for main branches, 13.9 kg for lateral branches, 3.7 kg for leaves, 6.7 kg for fruits, and 14.1 kg for roots. Amounts of C and N per tree were respectively 2.3 and 0.02 kg for trunk, 6.4 and 0.07 kg for main branches, 6.4 and 0.09 kg for lateral branches, 6.5 and 0.07 kg for roots, 1.7 and 0.07 kg for leaves, and 3.2 and 0.03 kg for fruits. Carbon and nitrogen stocks stored between the soil surface and a depth of 60 cm were 138.29 and $13.31Mg{\cdot}ha^{-1}$, respectively, while those contained in pear trees were 17.66 and $0.23Mg{\cdot}ha^{-1}$ based on a tree density of 667 $trees{\cdot}ha^{-1}$. Overall, carbon and nitrogen stocks per hectare stored in a pear orchard were 155.95 and 13.54 Mg, respectively.

Greenhouse Gas Inventory in Land-Use Change and Forestry in Korea (임업 및 토지이용부문의 온실가스 흡수 및 배출 현황)

  • 이경학;손영모;김영수
    • Journal of Korea Foresty Energy
    • /
    • v.20 no.1
    • /
    • pp.53-61
    • /
    • 2001
  • An approach method for the greenhouse gas inventory in land-use change and forestry in Korea based on the 1996 revised IPCC(Intergovernmental Panel on Climate Change) guideline was developed and carbon budget of the year 1998 in this sector was estimated using the developed method as follow. For the category of changes in forests and other woody biomass stocks, carbon removal from the atmosphere by growth was 11,911 thousands TC(tons of carbon), carbon emissions to the atmosphere by harvests was 824 thousands TC, and net carbon removals was, therefore, 11,087 thousands TC, Emissions from decay of biomass remained after conversion of forest land to other land uses was estimated to 82 thousands TC For the category of land-use change and management, carbon emissions in mineral soils from land-use change was 1,025 thousands TC, that from liming of agricultural soils was 32 thousands TC, and total emissions was, therefore, 1,057 thousands TC. In summary, the carbon budget of land-use change and forestry of the year 1988 was as follows; the removal of 11,911 thousands TC, the emissions of 1,963 thousands TC, and the net removal of 9,948 thousands TC which was 9.6% of the emissions of 103,601 thousands TC from energy sector of the same year.

  • PDF

Property Analysis of Municipal Solid Waste and Estimation of CO2 Emissions from Waste Incinerators (생활폐기물 특성 분석 및 소각시설의 CO2 배출량 평가)

  • Kim, Byung-Soon;Kim, Shin-Do;Kim, Chang-Hwan;Lee, Tae-Jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.657-665
    • /
    • 2010
  • Carbon dioxide ($CO_2$) is known to be a major greenhouse gas partially emitted from waste combustion facilities. According to the greenhouse gas emission inventory in Korea, the quantity of the gas emitted from waste sector in 2005 represents approximately 2.5 percent of all domestic greenhouse gas emission. Currently, the emission rate of greenhouse gas from the waste sector is relatively constant partly because of both the reduced waste disposal in landfills and the increased amounts of waste materials for recycling. However, the greenhouse gas emission rate in waste sectors is anticipated to continually increase, mainly due to increased incineration of solid waste. The objective of this study was to analyze the property of Municipal Solid Waste (MSW) and estimate $CO_2$ emissions from domestic MSW incineration facilities. The $CO_2$ emission rates obtained from the facilities were surveyed, along with other two methods, including Tier 2a based on 2006 IPCC Guideline default emission factor and Tier 3 based on facility specific value. The $CO_2$ emission rates were calculated by using $CO_2$ concentrations and gas flows measured from the stacks. Other parameters such as waste composition, dry matter content, carbon content, oxidation coefficient of waste were included for the calculation. The $CO_2$ average emission rate by the Tier 2a was 34,545 ton/y, while Tier 3 was 31,066 ton/y. Based on this study, we conclude that Tier 2a was overestimated by 11.2 percent for the $CO_2$ emission observed by Tier 3. Further study is still needed to determine accurate $CO_2$ emission rates from municipal solid waste incineration facilities and other various combustion facilities by obtaining country-specific emission factor, rather than relying on IPCC default emission factor.

The Estimation of Emission Factor of N2O and CH4 by Measurement from Stacks in the Waste Incinerators and Cement Production Plants

  • Choi, Sang-Min;Im, Jong-Kwon;Hong, Ji-Hyoung;Lee, Sue-Been;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.3
    • /
    • pp.217-226
    • /
    • 2007
  • The purpose of this study is to estimate the emission factor of $non-CO_2$ global warming gases such as $N_2O$ and $CH_4$ by measuring concentrations from stacks of waste incinerators and cement production plants. Based on the established monitoring methods, $N_2O$ concentration measured from stacks in incinerator were between 0.62 and $40.60\;ppm_v$ (ave. $11.50\;ppm_v$). The concentration of $N_2O$ was dependent on the incinerator types. However, the concentrations of $CH_4$ gas were between 2.65 and $5.68\;ppm_v$ (ave. $4.22\;ppm_v$), and did not show the dependency on the incinerator types. In the cement production plant, the concentration ranges of $N_2O$ from the stack were from 6.90 to $10.80\;ppm_v$ (ave. $8.60\;ppm_v$), and $CH_4$ were between 1.80 and $2.20\;ppm_v$ (ave. $2.60\;ppm_v$). Using measured concentrations, the emission amounts of $N_2O$ and $CH_4$ from stacks per year were calculated. The results were is 4.2 ton $N_2O/yr$ in the incinerators, and 53.7 ton $N_2O/yr$ in the cement facilities. The big difference is from the flow rate of flue gas in the cement facilities compared to the incinerators. By the same reason, the $CH_4$ emission amounts in cement plant and incinerator was found to be 339 ton $CO_2/yr$ and 34.1 ton $CO_2/yr$, respectively. Finally, the emission factor of $N_2O$ in the incinerators were calculated using the measured concentration and the amount of incinerated wastes, and was $42.5\sim799.1\;g/ton$ in kiln and stoker type, $11.9\sim79.9\;g/ton$ in stoker type, 90.1 ton/g in rotary kiln type, 174.9 g/ton in fluidized bed type, and 63.8 g/ton in grate type, respectively. Also, the emission factors of $CH_4$ were found to 65.2-91.3 g/ton in kiln/stoker type, 73.9-122 g/ton in stoker type, 109.5 g/ton rotary kiln, and 26.1 g/ton in fluidized bed type. This result indicates that the emission factor in incinerators is strongly dependent on the incinerator types, and matched with result of IPCC (International Panel on Climate Change) guideline.

A Study for Construction of CO2 Inventory Using GIS (지리정보시스템을 활용한 CO2 인벤토리 구축 방안에 관한 연구)

  • Oh, Sang-Hak;Kim, Dae-Wuk;Ryu, Ji-Won;Cha, Jae-Gyu;Jung, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.2
    • /
    • pp.40-52
    • /
    • 2011
  • In this study, $CO_2$ emission quantities by spatial characteristics using GIS were investigated for building a $CO_2$ emission inventory. Eventually, this study provides the guidelines to build the urban spatial structure for reducing greenhouse gas and contributes to the transition to environmental friendly green city. The attribute data for GIS were energy (electricity and gas) usage in the city of Daegu for 2009 and used for Tier 1 as suggested by the IPCC guideline to estimate amount of $CO_2$ emission. The spatial data were built based on land use types categorized by building purposes with connecting building registers to cadastral maps for Daegu city. Spatial $CO_2$ emission quantities could be calculated by combining $CO_2$ emission inventory for energy and GIS. Also, $CO_2$ emission characteristics were different by land use types.

Development of CO2 Emission Factor for Wood Chip Fuel and Reduction Effects (목질계 바이오매스 중 대체연료 우드칩의 온실가스(CO2) 배출계수 개발 및 저감 효과)

  • Lee, Seul-Ki;Kim, Seung-Jin;Cho, Chang-Sang;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.211-224
    • /
    • 2012
  • Technology for energy recovery from waste can reduce the greenhouse gas emissions. So recently, there are several companies using RDF, RPF, WCF instead of using only coal fuel and it's part of the fuel on the increase. In this study, we developed Wood chip fuel $CO_2$ emission factor through fuel analysis. It's moisture content is 23%, received net calorific value is 2,845 kcal/kg, and received basis carbon is 34%. The result of emission factor is $105ton\;CO_2/TJ$, it's 5.9% lower than 2006 IPCC guideline default factor $112ton\;CO_2/TJ$. The gross GHG(Greenhouse gases) emissions of plant A is $178,767ton\;CO_2 eq./yr$, and Net GHG emissions is $40,359ton\;CO_2 eq./yr$. Therefore, the reduction of GHG emissions is $138,408ton\;CO_2/yr$ through using WCF, and I accounts for 77% of all GHG emissions.

Comparison of the CO2 Emission Estimation Methods in a LNG Power Plant Based on the Mass Balance Approach (물질수지 방법을 고려한 액화천연가스 발전소에서의 온실기체 배출량 산정 방법 비교)

  • Kim, Hee-Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.235-244
    • /
    • 2013
  • Carbon dioxide emission estimation methods consist of four tiers according to the IPCC guideline. In this study, estimated results by tier 3 and tier 4 were compared with the theoretically calculated $CO_2$ emissions based on the mass balance approach for a gas fired power plant between March and May 2011. It was found that the relative differences were upto 17% between the measured emissions by tier 4 and theoretically estimated emissions, while the results of tier 3 were similar to those from theoretically estimated ones. The comparisons suggested the possibility of misestimation due to replacing missing, abnormal, or invalid data in continuous emissions monitoring system. When using only the data without those missing, abnormal, or invalid data, the relative differences decreased somewhat but still showed consistent differences depending on the stack. It is suggested that this differences might be due to the accuracy of the measurement instruments for the tier 4, especially, for the flow rate measurement instrument.

A Study on Reduction of Air Conditioning Energy Consumption by Surface Albedo Variation Using Meteorological Model (기상모델을 이용한 지표면 반사능에 따른 냉방에너지 소비 저감 연구)

  • AN, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.16-24
    • /
    • 2010
  • Recently environmental regulations like the Kyoto Protocol, adopted in 1997, required the 5.2% reduction of the greenhouse gas emission in 1990. And 13th General Assembly in 2007, held in Bali of India, have agreed to duty reduction even in developing countries in 2013. Korean government needs the researches on climate change and the strategic programs for greenhouse gas reduction. In this paper Colorado State University Mesoscale Model(CSU-MM) was applied to simulate the relationship between surface albedo and air temperature. Meteorological model simulation in region of Ansan-City, Shiheung-City showed that mean air temperature became lower with the increase of albedo value. Simulated air temperature became lower $-0.16^{\circ}C$ and $-0.66^{\circ}C$ by 5% and 20% increase of albedo values respectively. And cooling energy saving amount in air conditioning process was calculated according to lowered air temperature. The reduction of air temperature resulted the reduction of air conditioning energy in personal house and commercial buildings. The increase of albedo from 5% to 20% resulted the reduction of air conditioning energy from 44,493 MWh/yr to 183,796 MWh/yr. Additionally the reduction of greenhouse gas emission through the energy saving was calculated after IPCC guideline. In terms of greenhouse gas emission $CO_2$ was reduced form -30,414 ton-$CO_2$/yr to -125,638 ton-$CO_2$/yr according to the reduction of electric energy.

A Study of GHG-AP Integrated Inventories and Alternative Energy Use Scenario of Energy Consumption in the University (대학 내 에너지 소비에 따른 온실가스-대기오염 통합 인벤토리 및 대체 에너지 사용 시나리오 분석)

  • Jung, Jae-Hyung;Kwon, O-Yul
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1643-1654
    • /
    • 2014
  • The university is one of the main energy consumption facilities and thereby releases a large amount of greenhouse gas (GHG). Accordingly, efforts for reducing energy consumption and GHG have been established in many local as well as international universities. However, it has been limited to energy consumption and GHG, and has not included air pollution (AP). Therefore, we estimated GHG and AP integrated emissions from the energy consumed by Seoul National University of Science and Technology during the years between 2010 and 2012. In addition, the effect of alternative energy use scenario was analysed. We estimated GHG using IPCC guideline and Guidelines for Local Government Greenhouse Inventories, and AP using APEMEP/EEA Emission Inventory Guidebook 2013 and Air Pollutants Calculation Manual. The estimated annual average GHG emission was $11,420tonCO_{2eq}$, of which 27% was direct emissions from fuel combustion sectors, including stationary and mobile source, and the remaining 73% was indirect emissions from purchased electricity and purchased water supply. The estimated annual average AP emission was 7,757 kgAP, of which the total amount was from direct emissions only. The annual GHG emissions from city gas and purchased electricity usage per unit area ($m^2$) of the university buildings were estimated as $15.4kgCO_{2eq}/m^2$ and $42.4tonCO_{2eq}/m^2$ and those per person enrolled in the university were $210kgCO_{2eq}$/capita and $577kgCO_{2eq}$/capita. Alternative energy use scenarios revealed that the use of all alternative energy sources including solar energy, electric car and rain water reuse applicable to the university could reduce as much as 9.4% of the annual GHG and 34% of AP integrated emissions, saving approximately 400 million won per year, corresponding to 14% of the university energy budget.