• Title/Summary/Keyword: INTER-SUBJECT

Search Result 206, Processing Time 0.026 seconds

The Effects of SW Development Project with Social Collaboration tool on Inter-relationship Change of Women's University Students (소셜협업도구를 활용한 소프트웨어 개발 프로젝트가 여대생의 대인관계변화에 미치는 영향)

  • Kim, Hee Yeong;Kim, Su Sun
    • Journal of Engineering Education Research
    • /
    • v.20 no.5
    • /
    • pp.43-49
    • /
    • 2017
  • This paper deals with inter-relationship change of women's university students on the process of SW development project using social collaboration tool. Inter-relationship is one of the basic vocational competency in NCS(National Competency Standards) of Korea. We redesigned the curriculum of "Software Engineering" subject for this study and composed the project teams of students to develop software. The details of inter-relationship are satisfaction, communication, faith, friendliness, sensitivity, openness and consideration. From the result of this study, faith, openness and consideration have positive effect but satisfaction, communication, friendliness and sensitivity have no meaningful effect. The surveys were conducted in the beginning of semester and the same surveys were conducted again in the end of semester. The results were verified by paired t-test with SPSS 18.0. It is significant that the using of social collaboration tool for team project has positive effect on inter-relationship change, especially faith of women's university students. This study has some limitations for generalization but has meaning as new trial to enlarge the basic vocational competency of students in major subject, "Software Engineering". We expect new study for inter-relationship change of students to evaluate generality based on the proposed method in this paper.

Organ Shape Modeling Based on the Laplacian Deformation Framework for Surface-Based Morphometry Studies

  • Kim, Jae-Il;Park, Jin-Ah
    • Journal of Computing Science and Engineering
    • /
    • v.6 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • Recently, shape analysis of human organs has achieved much attention, owing to its potential to localize structural abnormalities. For a group-wise shape analysis, it is important to accurately restore the shape of a target structure in each subject and to build the inter-subject shape correspondences. To accomplish this, we propose a shape modeling method based on the Laplacian deformation framework. We deform a template model of a target structure in the segmented images while restoring subject-specific shape features by using Laplacian surface representation. In order to build the inter-subject shape correspondences, we implemented the progressive weighting scheme for adaptively controlling the rigidity parameter of the deformable model. This weighting scheme helps to preserve the relative distance between each point in the template model as much as possible during model deformation. This area-preserving deformation allows each point of the template model to be located at an anatomically consistent position in the target structure. Another advantage of our method is its application to human organs of non-spherical topology. We present the experiments for evaluating the robustness of shape modeling against large variations in shape and size with the synthetic sets of the second cervical vertebrae (C2), which has a complex shape with holes.

Inter-and Intra-rater Reliabilities of Myotonometric Measurement of the Erector Spinae Muscles in the Young and Old Age Groups (청년과 노인 연령군에 따른 척주세움근에 대한 마이오톤의 측정자 간, 측정자 내 신뢰도)

  • Han, Hyo-Gyeong;Choe, Ye-Ju;Jeong, Seong-Ho;Lee, Na-Kyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.193-202
    • /
    • 2021
  • Purpose : The purpose of this study is to examine inter-and intra-rater reliabilities of myotonometric measurements of tone, elasticity and stiffness for the erector spinae muscles of the young and the elderly populations. Methods : A total of 102 (69 young adults from K university and 33 older adults from the D community center in Daejeon) were enrolled in this study. The two different raters measured each side of the erector spinae muscles at prone position. After each rater performed first measurement for a subject, 30 minutes of rest was given. The same rater then repeated the second myometric measurement on the subject. The collected data on the tone, elasticity, and stiffness of the erector spinae were analyzed using intraclass correlation coefficient (ICC) to determine inter- and intra- rater reliabilities. Results : The inter-and intra-rater reliabilities of the myotonometric measurement of the erector spinae for the total subjects were excellent (ICC > 0.9, p < 0.001). Within each of the elderly group and the young group, inter- and intra-rater reliabilities were also excellent (ICC > 0.8~0.9 / p < 0.001, ICC > 0.75~0.9 / p < 0.001, each). Conclusion : The measurement of muscle tone, elasticity, and stiffness for the erector spinae muscles using the myotonometer had excellent reliability. It was confirmed that a highly reliable myometric measurement on the erector spinae can be obtained regardless of whether it is from young or elderly people. This suggests that the myotonometer can be a useful tool to measure muscular properties of the erector spinae of the young and old as an evaluative instrument.

Standard Error of Empirical Bayes Estimate in NONMEM$^{(R)}$ VI

  • Kang, Dong-Woo;Bae, Kyun-Seop;Houk, Brett E.;Savic, Radojka M.;Karlsson, Mats O.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.2
    • /
    • pp.97-106
    • /
    • 2012
  • The pharmacokinetics/pharmacodynamics analysis software NONMEM$^{(R)}$ output provides model parameter estimates and associated standard errors. However, the standard error of empirical Bayes estimates of inter-subject variability is not available. A simple and direct method for estimating standard error of the empirical Bayes estimates of inter-subject variability using the NONMEM$^{(R)}$ VI internal matrix POSTV is developed and applied to several pharmacokinetic models using intensively or sparsely sampled data for demonstration and to evaluate performance. The computed standard error is in general similar to the results from other post-processing methods and the degree of difference, if any, depends on the employed estimation options.

Template-Based Reconstruction of Surface Mesh Animation from Point Cloud Animation

  • Park, Sang Il;Lim, Seong-Jae
    • ETRI Journal
    • /
    • v.36 no.6
    • /
    • pp.1008-1015
    • /
    • 2014
  • In this paper, we present a method for reconstructing a surface mesh animation sequence from point cloud animation data. We mainly focus on the articulated body of a subject - the motion of which can be roughly described by its internal skeletal structure. The point cloud data is assumed to be captured independently without any inter-frame correspondence information. Using a template model that resembles the given subject, our basic idea for reconstructing the mesh animation is to deform the template model to fit to the point cloud (on a frame-by-frame basis) while maintaining inter-frame coherence. We first estimate the skeletal motion from the point cloud data. After applying the skeletal motion to the template surface, we refine it to fit to the point cloud data. We demonstrate the viability of the method by applying it to reconstruct a fast dancing motion.

Cost analysis on renewable warranty policies subject to imperfect strategies using inter-failure intervals

  • Park, Minjae
    • International Journal of Reliability and Applications
    • /
    • v.14 no.1
    • /
    • pp.41-54
    • /
    • 2013
  • In this paper, cost analysis is conducted using inter-failure interval under renewable warranty subject to imperfect repair for multi-component system. One way to model the imperfect repair is to use the quasi-renewal process (Wang and Pham 1996). Two alternative quasi-renewal processes were suggested by Park and Pham (2010) using quasi-renewal process; first is an altered quasi-renewal process with random variable parameter and second is a mixed quasi-renewal process considering replacement service and repair service, simultaneously. In this study, we use the altered and mixed quasi-renewal processes and develop the warranty cost model to obtain the expected value of warranty cost and to help company make important decisions regarding the warranty policy. Numerical examples are used to demonstrate the applicability of the methodology derived in the paper.

  • PDF

Multimodality and Non-rigid Registration of MRI' Brain Image

  • Li, Binglu;Kim, YoungSeop
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.1
    • /
    • pp.102-104
    • /
    • 2019
  • Registering different kinds of clinical images widely used in diagnostic and surgery planning. However, cause of tumor growth or effected by gravity, human tissue has plenty of non-rigid deformation with clinically. Non-rigid registration allows the mapping of straight lines to curves. Therefore, such local deformation makes registration more complicated. In this work, we mainly introduce intra-subject, inter-modality registration. This paper mainly studies the nonlinear registration method of 2D medical image registration. The general medical image registration algorithm requires manual intervention, and cost long registration time. In our work to reduce the registration time in rough registration step, the barycenter and the direction of main axis of the image is calculated, which reduces the calculation amount compared with the method of using mutual information.

A Study on the Readjustment Plans for Solution of Conflict in Gaeseong Complex - Centering around the Inter-Korean Commercial Arbitration System (개성공단 분쟁해결 제도 정비방안 - 남북상사중재제도를 중심으로)

  • Hwangbo, Hyun
    • Journal of Arbitration Studies
    • /
    • v.29 no.4
    • /
    • pp.3-31
    • /
    • 2019
  • In order to achieve full-scale economic cooperation between North Korea and South Korea, the Gaesong Industrial Complex should reopen first. In this case, the Inter-Korean commercial arbitration system should be clearly established to effectively resolve the disputes arising in the special economic zones of the Gaesong Industrial Complex. Even though the Inter-Korean Investment Security Agreement, the Agreement on the Resolution of Commercial Disputes between North Korea and South Korea, the Agreement on the Formation and Operation of the Inter-Korean Commercial Arbitration Committee, and the Agreement on the Formation and Operation of the Inter-Korean Commercial Arbitration Committee in the Gaesong Industrial District are in place, specific arbitration procedure is not concretely agreed upon and realized between the two Koreas. Therefore, the realization of commercial arbitration between them led by the Ministry of Unification or the government should be accomplished. In addition, it is necessary to consider the administrative trial or administrative litigation system in order to deal with administrative disputes that are not subject to commercial arbitration. Lastly, discussions on legal integration between the two Koreas should continue, focusing on the special economic zone of the Gaesong Industrial Complex, in order to prevent integration from being hindered by a different culture for a long time.

Intra and Inter-Rater Measurement Reliability of Tibialis Anterior Muscle (TA) Thickness using the Ultrasonography Spring Gauge Technique

  • Hwang, Byeong-Hun;Jang, Tae-Jin;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.4
    • /
    • pp.187-192
    • /
    • 2021
  • Purpose: The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness measurement of the TA using ultrasonography (US) conducted at different inward pressures of approximately 0.5 kg, 1.0 kg, and no pressure control. Methods: Twenty healthy subjects were recruited for this study. Two different examiners measured the thicknesses of the dominant TA of each subject randomly to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval, standard error of measurement, minimal detectable change, and coefficient of variance. Results: All intra-rater reliability ICC values showed high reliability above 0.9. Inter-rater reliability ICC values showed high reliability above 0.9 with 0.5 and 1.0 kg of inward pressure. In contrast, Inter-rater reliability ICC values showed poor reliability (0.23) with no pressure control of inward pressure. Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results when the muscle thickness of the TA is measured by different examiners in a clinical setting.

Knee Cartilage Defect Assessment using Cartilage Thickness Atlas (무릎 연골 두께 아틀라스를 통한 손상 평가 기법)

  • Lee, Yong-Woo;Bui, Toan Duc;Ahn, Chunsoo;Shin, Jitae
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.2
    • /
    • pp.43-47
    • /
    • 2015
  • Osteoarthritis is the most common chronic joint disease in the world. With its progression, cartilage thickness tends to diminish, which causes severe pain to human being. One way to examine the stage of osteoarthritis is to measure the cartilage thickness. When it comes to inter-subject study, however, it is not easy task to compare cartilage thickness since every human being has different cartilage structure. In this paper, we propose a method to assess cartilage defect using MRI inter-subject thickness comparison. First, we used manual segmentation method to build accurate atlas images and each segmented image was labeled as articular surface and bone-cartilage interface in order to measure the thickness. Secondly, each point in the bone-cartilage interface was assigned the measured thickness so that the thickness does not change after registration. We used affine transformation and SyGN to get deformation fields which were then applied to thickness images to have cartilage thickness atlas. In this way, it is possible to investigate pixel-by-pixel thickness comparison. Lastly, the atlas images were made according to their osteoarthritis grade which indicates the degree of its progression. The result atlas images were compared using the analysis of variance in order to verify the validity of our method. The result shows that a significant difference is existed among them with p < 0.001.