• Title/Summary/Keyword: IMA

Search Result 152, Processing Time 0.023 seconds

Free vibrations of AFG cantilever tapered beams carrying attached masses

  • Rossit, Carlos A.;Bambill, Diana V.;Gilardi, Gonzalo J.
    • Structural Engineering and Mechanics
    • /
    • v.61 no.5
    • /
    • pp.685-691
    • /
    • 2017
  • The free transverse vibrations of axially functionally graded (AFG) cantilever beams with concentrated masses attached at different points are studied in this paper. The material properties of the AFG beam, consisting of metal and ceramic, vary continuously in the axial direction according to an established law form. Approximated solutions for the title problem are obtained by means of the Ritz Method. The influence of the material variation on the natural frequencies of vibration of the functionally graded beam is investigated and compared with the influence of the variation of the cross section. The phenomenon of dynamic stiffening of beams can be observed in various situations. The accuracy of the procedure is verified through results available in the literature that can be represented by the model under study.

A note on buckling and vibration of clamped orthotropic plates under in-plane loads

  • Felix, D.H.;Bambill, D.V.;Rossit, C.A.
    • Structural Engineering and Mechanics
    • /
    • v.39 no.1
    • /
    • pp.115-123
    • /
    • 2011
  • The present work deals with obtaining the critical buckling load and the natural frequencies of clamped, orthotropic, rectangular thin plates subjected to different linear distributed in-plane forces. An analytical solution is proposed. Using the Ritz method, the dependence between in-plane forces and natural frequencies are estimated for various plate sizes, and some results are compared with finite element solutions and where possible, comparison is made with previously published results. Beam functions are used as admissible functions in the Ritz method.

The Differences of Fixation Method in Proximal Chevron Osteotomy for Hallux Valgus: K-Wire, Cannulated Screw, Plate (무지외반증에서 근위 갈매기형 절골술 후 고정 방법에 따른 차이: K-강선, 유관나사, 금속판)

  • Kim, Taik-Seon;Kim, Hak-Jun;Park, Young-Hwan;Lim, Hyung-Tae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.62-67
    • /
    • 2011
  • Purpose: The authors evaluated the differences between K-wires and Cannulated screw, plate for fixing the proximal metatarsal chevron osteotomy of moderate and severe hallux valgus. Materials and Methods: There were 62 patients (79 feetz) who were moderate and severe degree hallux valgus according to the classification of Mann. They all got the proximal chevron osteotomy when correcting the deformity. We divided the patients into 4 groups, Two K-wire fixed group as A, one cannulated screw fixed group as B. Two cannulated screw fixed group as C, Plate fixed group as D, Group A were patients (26 feet) and Group B were patients z(9 feet), Group C were patients (31 feet) and Group D were patients (13 feet). Preoperative, postoperative and follow-up hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured for each patient. ANOVA test and Student t-test were done for statistical analysis. Results: Mean follow up period was 43.8 months (range: 12~82 months). Preoperative mean IMA was $16.4{\pm}3.5$, $17.7{\pm}11.3$, $17.3{\pm}5.9$ and $16.6{\pm}2.3$ degrees in respectively group A, B, C, D. Immediate postoperative mean IMA was $5.6{\pm}3.4$, $7.3{\pm}4.4$, $7.6{\pm}4.4$ and $6.7{\pm}2.8$ degrees in respectively group A, B, C, D. The final mean IMA was $8.9{\pm}4.5$, $15.2{\pm}7.5$, $10.3{\pm}4.4$ and D $7.7{\pm}3.5$ degrees in respectively group A, B, C, D. There were significant statistical increase in final mean IMA of group B and C (p<0.05). Conclusion: The IMA was significantly increased in the group which used one or two cannulated screw for fixation on follow up, therefore more caution should be needed when using one or two cannulated screw fixation technique after proximal chevron osteotomy.

IMA$\^+$ 98

  • 신재인
    • Nuclear industry
    • /
    • v.17 no.12 s.178
    • /
    • pp.60-61
    • /
    • 1997
  • PDF

Operative Treatment of Hallux Valgus Deformity in Male Patients (남성 무지 외반증 환자에 대한 수술적 치료)

  • Youn, Te-Hyun;Kim, Seong-Kek;Shim, Hee-Jong;Lee, Jun-Young;An, Ki-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.129-132
    • /
    • 2009
  • Purpose: We evaluated the result of operative treatment of the hallux valgus in male patients. Materails and Methods: Total 11 cases (10 patients) of the hallux valgus deformity that treated with operation were evaluated. Following Mann's radiological classification system, there was 1 cases of mild, 8 cases of moderate, and 2 cases of severe. Preoperative, postoperative, postoperative 3 months and postoperative 6 months follow up standing radiographs were used as radiologic evaluation. And we evaluated radiological outcomes by hallux valgus angle (HVA), first-second intermetatarsal angle (IMA), distal metatarsal articular angle (DMAA), proximal phalangeal articular angle (PPAA) and clinical outcomes by hallux-metatarsophalangeal scale of American Orthopaedic Foot and Ankle Society (AOFAS) score. Result: Radiologically, the mean preoperative HVA $37^{\circ}$ and IMA $13.7^{\circ}$ were improved postoperatively as HVA $11.9^{\circ}$ and IMA $4.7^{\circ}$, and the mean preoperative DMMA $29.4^{\circ}$ and PPAA $8.6$ were improved postoperatively DMMA $13.9^{\circ}$ and PPAA $7^{\circ}$. But, postoperative 6 months follow up HVA, IMA, DMMA and PPAA was increased at $14.2^{\circ}$, $6.3^{\circ}$, $16.1^{\circ}$ and $8.3^{\circ}$. Average AOFAS score were improved from 61.2 points to 75.2 points. Conclusion: In our study, operative treatment of hallux valgus in male patients with proximal metatarsal osteotomy and distal soft tissue procedure showed good results but it was necessary to pay attention to increase aspect of follow up radiologic measurements.

  • PDF

Development of a Food-Grade Integration Vector for Heterologous Gene Expression and Protein Secretion in Lactococcus lactis

  • Jeong, Do-Won;Lee, Jong-Hoon;Kim, Kyoung-Heon;Lee, Hyong-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.11
    • /
    • pp.1799-1808
    • /
    • 2006
  • A food-grade integration vector based on site-specific recombination was constructed. The 5.7-kb vector, pIMA20, contained an integrase gene and a phage attachment site originating from bacteriophage A2, with the ${\alpha}$-galactosidase gene from Lactobacillus plantarum KCTC 3104 as a selection marker. pIMA20 was also equipped with a controllable promoter of nisA ($P_{nisA}$) and a signal peptide-encoding sequence of usp45 ($SP_{usp45}$) for the production and secretion of foreign proteins. pIMA20 and its derivatives mediated site-specific integration into the attB-like site on the Lactococcus lactis NZ9800 chromosome. The vector-integrated recombinant lactococci were easily detected by the appearance of blue colonies on a medium containing $X-{\alpha}-gal$ and also by their ability to grow on a medium containing melibiose as the sole carbon source. Recombinant lactococci maintained these traits in the absence of selection pressure during 100 generations. The ${\alpha}-amylase$ gene from Bacillus licheniformis, lacking a signal peptide-encoding. sequence, was inserted downstream of $P_{nisA}\;and\;SP_{usp45}$ in pIMA20, and the plasmid was integrated into the L. lactis chromosome. ${\alpha}-Amylase$ was successfully produced and secreted by the recombinant L. lactis, controlled by the addition and concentration of nisin.

Assay of Heat Stable Enterotoxin Producing E. coli (내열성장독소 생산 대장균의 판정)

  • Chang, Woo-Hyun;Kim, Moon-Gyo;Choi, Myung-Sik;Yang, Nam-Ung;Ko, Kwang-Wook;Seo, Jung-Ki
    • The Journal of the Korean Society for Microbiology
    • /
    • v.18 no.1
    • /
    • pp.53-58
    • /
    • 1983
  • Enterotoxigenic E. coli is one of causative agents of the infantile diarrhea and traveler's diarrhea. A modified infant mouse assay(IMA) was developed for the detection of heat stable enterotoxin (ST) of E. coli isolated from diarrheal and control infants and assay system was established with using enterotoxin producing reference strains. The supernatant of the 24 hour-shaking culture of E. coli in Casamino Acid Yeast Extract Salt Broth(CYES-2) was ingested orally into the 2-4 day old ICR mice. After the mice were kept at $25^{\circ}C$ for 4 hours, they were sacrificed and the gut weight body weight ratio(GW/BW) was taken as the index of fluid accumulation induced by heat stable enterotoxin of E. coli. The results obtained were as follows; 1. The GW/BW responses of IMA tested with enterotoxin reference strains of E. coli(E. coli O148H28:$ST^+LT^+$, E. coli $O78H^-:ST^+LT^+$, E. coli O15H11:$ST^-LT^+$, E. coli O1H7:$ST^-LT^-$) appeared ta be ST dose-dependent, and not LT-dependent. From the dose-response curve, $25{\mu}l$ of culture supernatant was determined as test amount of the IMA. 2. Frequency distribution of IMA result from 643 strain of E. coli showed normal distribution at low GW/BW ratio and dispersed pattern at high GW/BW ratio. The GW/BW ratios of $0.056{\pm}0.004(mean{\pm}SD)$ of normal distribution which distributed from 0.044 to 0.068(P<0.01) was considered as ST negative. Thus the GW/BW ratio above 0.069 could be regarded as ST positive.

  • PDF

Comparison of Sesamoid Bone Position and Hallux Valgus Angle in Weight Bearing Conditions between Subjects with and without Hallux Valgus

  • Kim, Moon-Hwan;Jeon, In-Cheol;Hwang, Ui-Jae;Kim, Young
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.6
    • /
    • pp.381-384
    • /
    • 2016
  • Purpose: Previous studies reported changes in the first metatarsophalangeal (MTP) joint angle in relation with and without weight bearing, but it is unclear whether sesamoid bone of the great toe changes in weight bearing conditions particularly in subjects with hallux valgus (HV). To investigate how weight bearing conditions can affect the position of the medial sesamoid bone (MSB), first MTP joint angle, and second intermetatarsal angle (IMA) in the recruited subjects. Methods: Subjects were recruited 24 with HV and 21 without HV in study. X-rays were taken in the weight bearing and non-weight bearing conditions. The distance of the MSB, first MTP joint angle, and second IMA were measured from the radiographs. Data were analyzed by paired and Independent t-test. The statistical significance level was p<0.05. Results: In both groups, the first MTP joint angles and the distance of the MSB were significantly smaller, while the second IMA was significantly greater in the weight bearing condition. The difference in the distance of the MSB between the two postures was significantly greater in the group with HV. Conclusion: Weight bearing can affect the first MTP joint angle, second IMA, and position of the MSB; the change in the position of the MSB in weight bearing was greater in the group with hallux valgus. The difference in these variables between weight bearing and non-weight bearing conditions may be considered when measuring HV.

Change point estimators in monitoring the parameters of an IMA(1,1) model (누적이동평균(1,1) 모형에서 공정 변화시점의 추정)

  • Lee, Ho-Yun;Lee, Jae-Heon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.2
    • /
    • pp.435-443
    • /
    • 2009
  • Knowing the time of the process change could lead to quicker identification of the responsible special cause and less process down time, and it could help to reduce the probability of incorrectly identifying the special cause. In this paper, we propose the maximum likelihood estimator (MLE) for the process change point when a control chart is used in monitoring the parameters of a process in which the observations can be modeled as a IMA(1,1).

  • PDF

Internal Mammary Artery Injury Caused by Blunt Chest Trauma Treated with Transcatheter Arterial Embolization (흉부 둔상에 의해 발생한 내흉동맥 손상의 카테터경유 혈관색전술 치료 경험)

  • Choi, Seok Jin;Jeong, Tae Oh;Lee, Jae Baek;Yoon, Jae Chol
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.296-299
    • /
    • 2012
  • The aorta is the most common major thoracic artery injured by blunt chest trauma. Injuries to major aortic arch branch arteries can also occur but are much less common than aortic injuries in the setting of blunt trauma. Although internal mammary artery (IMA) injury is uncommon and rarely diagnosed in cases of blunt chest trauma, it is one of the important sources of bleeding in chest trauma. IMA bleeding can cause ongoing blood loss and may lead to serious conditions such as extensive hemothorax, anterior mediastinal hematoma or its catastrophic complication, cardiac tamponade. However such arotic and branch artery injuries are not easily detected by plain radiograph, and are detected indirectly because of associated mediastinal hematoma. Herein, we report a case of IMA injury caused by blunt chest trauma secondary to pedestrian traffic accident. The injured patient was successfully treated by transcatheter arterial embolization (TAE).