• Title/Summary/Keyword: IL4R

Search Result 1,526, Processing Time 0.034 seconds

Association Analysis between Chromogranin B Genetic Variations and Smooth Pursuit Eye Movement Abnormality in Korean Patients with Schizophrenia (한국인 조현병 환자에서 Chromogranin B 유전자와 안구운동 이상의 연합에 대한 연구)

  • Park, Jin Wan;Pak, Doo Hyun;Hwang, Min Gyu;Lee, Min Ji;Shin, Hyoung Doo;Shin, Tae-Min;Hahn, Sang Woo;Hwang, Jaeuk;Lee, Yeon Jung;Woo, Sung-Il
    • Korean Journal of Biological Psychiatry
    • /
    • v.25 no.4
    • /
    • pp.101-109
    • /
    • 2018
  • Objectives According to previous studies, the Chromogranin B (CHGB) gene could be an important candidate gene for schizophrenia which is located on chromosome 20p12.3. Some studies have linked the polymorphism in CHGB gene with the risk of schizophrenia. Meanwhile, smooth pursuit eye movement (SPEM) abnormality has been regarded as one of the most consistent endophenotype of schizophrenia. In this study, we investigated the association between the polymorphisms in CHGB gene and SPEM abnormality in Korean patients with schizophrenia. Methods We measured SPEM function in 24 Korean patients with schizophrenia (16 male, 8 female) and they were divided according to SPEM function into two groups, good and poor SPEM function groups. We also investigated genotypes of polymorphisms in CHGB gene in each group. A logistic regression analysis was performed to find the association between SPEM abnormality and the number of polymorphism. Results The natural logarithm value of signal/noise ratio (Ln S/N ratio) of good SPEM function group was $4.19{\pm}0.19$ and that of poor SPEM function group was $3.17{\pm}0.65$. In total, 15 single nucleotide polymorphisms of CHGB were identified and the genotypes were divided into C/C, C/R, and R/R. Statistical analysis revealed that two genetic variants (rs16991480, rs76791154) were associated with SPEM abnormality in schizophrenia (p = 0.004). Conclusions Despite the limitations including a small number of samples and lack of functional study, our results suggest that genetic variants of CHGB may be associated with SPEM abnormality and provide useful preliminary information for further study.nwhile, smooth pursuit eye movement (SPEM) abnormality has been regarded as one of the most consistent endophenotype of schizophrenia. In this study, we investigated the association between the polymorphisms in CHGB gene and SPEM abnormality in Korean patients with schizophrenia. MethodsZZWe measured SPEM function in 24 Korean patients with schizophrenia (16 male, 8 female) and they were divided according to SPEM function into two groups, good and poor SPEM function groups. We also investigated genotypes of polymorphisms in CHGB gene in each group. A logistic regression analysis was performed to find the association between SPEM abnormality and the number of polymorphism. ResultsZZThe natural logarithm value of signal/noise ratio (Ln S/N ratio) of good SPEM function group was $4.19{\pm}0.19$ and that of poor SPEM function group was $3.17{\pm}0.65$. In total, 15 single nucleotide polymorphisms of CHGB were identified and the genotypes were divided into C/C, C/R, and R/R. Statistical analysis revealed that two genetic variants (rs16991480, rs76791154) were associated with SPEM abnormality in schizophrenia (p = 0.004). ConclusionsZZDespite the limitations including a small number of samples and lack of functional study, our results suggest that genetic variants of CHGB may be associated with SPEM abnormality and provide useful preliminary information for further study.

  • PDF

The Effects of the High Pressure Boiled Extracts (HPBE) of the Ogol Chicken with Herbs on the Hormones, Cytokine, Specific Antibody of Serum in the Rat (오골계 증탕액 급여가 흰쥐의 혈중 호르몬, Cytokine 및 특이항체에 미치는 영향)

  • Chae Hyun-Seok;Ahn Chong-Nam;Yoo Young-Mo;Ham Jun-Sang;Lee Jong-Moon;Yoon Sang-Ki;Choi Yang-Il
    • Food Science of Animal Resources
    • /
    • v.24 no.3
    • /
    • pp.283-292
    • /
    • 2004
  • This study was conducted to investigate feeding effects of the high pressure boiled extracts (HPBE) of the Ogol chicken with herbs on glucose, hormones and immunological response (cytokine, specific antibody) of serum in the rat which fed either with normal feed (T$_1$), normal feed + herb HPBE (T$_2$), normal feed + Ogol chicken HPBE (T$_3$), normal feed + mixture of cross-bred Ogol chicken HPBE (T$_4$) hydrolyzed with Flavourzyme 0.1% for 35 days. During experimental period, there was a weak trend to have a higher glucose content for the T$_4$ group with 102.27${\pm}$5.95 mg/dL, but it was not significantly higher than other treatments. For insulin level, T$_1$ group showed numerically a slightly higher level with 6.79${\pm}$4.64 ${\mu}$IU/mL, but the difference was not significant in statistic term due likely to a large variation in comparison with other treatments. The treatments did not significantly alter testosterone level in rat plasma with 1.09, 1.46, 0.98, 1.13 ng/mL in T$_1$, T$_2$, T$_3$ and T$_4$, respectively. T$_4$ treatment increased the aldosterone level to a significantly (p<0.05) higher level (273.33 ng/dL) than other treatments. The extract treated rat showed a tendency in the cortisol level of lower levels than the control group, particularly, it was significantly (p<0.05) lower in T$_3$ group than other groups. T$_3$ and T$_4$ groups showed higher levels for interlukin-4 (IL-4) and anti-BSA IgG in immune cells and plasma. T$_2$, T$_3$ and T$_4$ treatments showed a slightly higher levels in v-interferon (INF-r) than the control, with a greater effect for T4 treatments. These results suggested that HPBE of the cross-bred Ogol chicken hydrolyzed with Flavourzyme increased immunological activity and decreased the concentration of cortisol and aldosterone hormones.

Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET ($^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계)

  • Lee, Byeong-Il;Kim, Kye-Hun;Kim, Jung-Young;Kim, Su-Jin;Lee, Jae-Sung;Min, Jung-Joon;Song, Ho-Chun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.194-200
    • /
    • 2007
  • Purpose: $^{13}N$-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Methods: Twelve patients (11 males, 1 female, $57.9{\pm}8.6$ years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: $5\;sec\;{\times}\;12,\;10\;sec\;{\times}\;6,\;20\;sec\;{\times}\;3,\;and\;30\;sec\;{\times}\;6$) were initiated simultaneously with bolus injection of 11 MBq/kg $^{13}N-ammonia$ to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. Results: There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Conclusions: Corrected and translated MPS as its characteristics using $^{13}N$-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.

Climate Change Impact on Nonpoint Source Pollution in a Rural Small Watershed (기후변화에 따른 농촌 소유역에서의 비점오염 영향 분석)

  • Hwang, Sye-Woon;Jang, Tae-Il;Park, Seung-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.4
    • /
    • pp.209-221
    • /
    • 2006
  • The purpose of this study is to analyze the effects of climate change on the nonpoint source pollution in a small watershed using a mid-range model. The study area is a basin in a rural area that covers 384 ha with a composition of 50% forest and 19% paddy. The hydrologic and water quality data were monitored from 1996 to 2004, and the feasibility of the GWLF (Generalized Watershed Loading function) model was examined in the agricultural small watershed using the data obtained from the study area. As one of the studies on climate change, KEI (Korea Environment Institute) has presented the monthly variation ratio of rainfall in Korea based on the climate change scenario for rainfall and temperature. These values and observed daily rainfall data of forty-one years from 1964 to 2004 in Suwon were used to generate daily weather data using the stochastic weather generator model (WGEN). Stream runoff was calibrated by the data of $1996{\sim}1999$ and was verified in $2002{\sim}2004$. The results were determination coeff, ($R^2$) of $0.70{\sim}0.91$ and root mean square error (RMSE) of $2.11{\sim}5.71$. Water quality simulation for SS, TN and TP showed $R^2$ values of 0.58, 0.47 and 0.62, respectively, The results for the impact of climate change on nonpoint source pollution show that if the factors of watershed are maintained as in the present circumstances, pollutant TN loads and TP would be expected to increase remarkably for the rainy season in the next fifty years.

Comparison of Enalapril Maleate Tablets on Bioavailability and the Time Course of Inhibition of Plasma Angiotensin-Converting Enzyme (Enalapril Maleate 정제의 동등성에 관한 연구 ; 약동학적 성상 및 혈장 ACE 활성도 억제 효과)

  • Jang, In-Jin;Jang, Byung-Soo;Shin, Sang-Goo;Shin, Jae-Gook;Rho, Il-Kun;Lee, Kyeong-Hun;Park, Chan-Woong
    • The Korean Journal of Pharmacology
    • /
    • v.26 no.2
    • /
    • pp.219-226
    • /
    • 1990
  • Enalapril maleate tablets of two different producers were tested for bioequivalence. Enalapril is rapidly metabolized to an active metabolite, enalaprilat which inhibits angiotensin-converting enzyme (ACE). The pharmacokinetics of enalapril maleate and the time course of inhibition of plasma ACE activity after administration of the drugs were studied. Two single doses of 10mg each of enalapril maleate were administered orally to twelve male volunteers in a balanced, randomized, two-way crossover investigation. Plasma enalaprilat concentrations were determined over a 23-hour after the dose by enzyme inhibition assay and enalapril by the same method following in vitro hydrolysis. Urinary recoveries of enalapril and enalaprilat were determined for the calculation of renal clearance. Plasma ACE activity was determined by an enzyme assay. Peak plasma levels of enalapril were observed about 1 hour after the doses, and practically all enalapril had disappeared from plasma within 6 hour. Peak enalapril concentrations of both formulations were almost identical ($Vasotec^{\circledR}$, 61.38 ng/ml; $Beartec^{\circledR}$, 64.27 ng/ml). The values of the pharmacokinetic parameters of enalaprilat computed for $Vasotec^{\circledR}$ and $Beartec^{\circledR}$ tablets are presented in that order; area under the curve=330.63:320.96 $ng{\cdot}hr/ml$; peak concentration=38.63:39.43 ng/ml; time to peak=3.83:4.08 hour; elimination half-life=3.95:3.92 hours. No statistically significant difference was detected when area under the curve and all other parameters were compared. Using criteria of 95% confidence interval for the comparison of these parameters, only the upper limits of area under the curve and time to peak of enalapril were over 120%. All the parameters of enalaprilat were acceptable. Percent inhibition of plasma ACE to plasma enalaprilat concentration showed the sigmoid concentration-inhibition relationship. Time courses of plasma ACE inhibition after the administration of both formulations were quite similar. The formulations were found to be equivalent when compared on the premise that no significant difference was detected when pharmacokientic parameters and inhibition of ACE activity were compared, based on the confidence limits analysis.

  • PDF

Validation of Extreme Rainfall Estimation in an Urban Area derived from Satellite Data : A Case Study on the Heavy Rainfall Event in July, 2011 (위성 자료를 이용한 도시지역 극치강우 모니터링: 2011년 7월 집중호우를 중심으로)

  • Yoon, Sun-Kwon;Park, Kyung-Won;Kim, Jong Pil;Jung, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.4
    • /
    • pp.371-384
    • /
    • 2014
  • This study developed a new algorithm of extreme rainfall extraction based on the Communication, Ocean and Meteorological Satellite (COMS) and the Tropical Rainfall Measurement Mission (TRMM) Satellite image data and evaluated its applicability for the heavy rainfall event in July-2011 in Seoul, South Korea. The power-series-regression-based Z-R relationship was employed for taking into account for empirical relationships between TRMM/PR, TRMM/VIRS, COMS, and Automatic Weather System(AWS) at each elevation. The estimated Z-R relationship ($Z=303R^{0.72}$) agreed well with observation from AWS (correlation coefficient=0.57). The estimated 10-minute rainfall intensities from the COMS satellite using the Z-R relationship generated underestimated rainfall intensities. For a small rainfall event the Z-R relationship tended to overestimated rainfall intensities. However, the overall patterns of estimated rainfall were very comparable with the observed data. The correlation coefficients and the Root Mean Square Error (RMSE) of 10-minute rainfall series from COMS and AWS gave 0.517, and 3.146, respectively. In addition, the averaged error value of the spatial correlation matrix ranged from -0.530 to -0.228, indicating negative correlation. To reduce the error by extreme rainfall estimation using satellite datasets it is required to take into more extreme factors and improve the algorithm through further study. This study showed the potential utility of multi-geostationary satellite data for building up sub-daily rainfall and establishing the real-time flood alert system in ungauged watersheds.

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

Preparation and Flame Retardancy Effect of Polyurethane Coatings Containing Phosphorus and Chlorine (인과 염소를 함유하는 폴리우레탄 도료의 제조와 난연효과)

  • Shim Il-Woo;Jo Hye-Jin;Park Hong-Soo;Kim Seong-Kil;Kim Young-Geun
    • Polymer(Korea)
    • /
    • v.30 no.3
    • /
    • pp.238-246
    • /
    • 2006
  • The aim of this study is to enhance the flame retardancy by the synergism effect of chlorine and phosphorus groups. The flame-retardant polyurethane coatings containing chlorine and phosphorus compounds were synthesized. After synthesizing the intermediate products of tetramethylene bis (orthophosphate) (TMBO) and neohexanediol trichlorobenzoate (TBA-adduct), the condensation polymerization was performed with four different monomers of two intermediates, 1,4-butanediol, and adipic acid to obtain four-component copolymer(TTBA). The two-component flame-retardant polyurethane coatings (TTBA-10C/HDI-trimer=TTHD-10C, TTBA-20C/HDI-trimer=TTHD-20C, TTBA-30C/HDI trimer=TTHD-30C) were obtained by curing reaction at room temperature with the synthesized TTBAs and hexamethylene diisocyanate (HDI)-trimer as a curing agent. The obtained TTHDs were made into coating samples and used as test samples for various physical properties. The physical properties of the flame-retardant coatings containing chlorine and phosphorus groups were generally inferior to those containing only phosphorus group. Flame retardancy was tested by vortical and horizontal combustion method, and $45^{\circ}$ Meckel burner method. Since the retardancy of flame-retardant coatings containing chlorine and phosphorus groups was better than that containing only phosphorus group, it could be concluded that the retardancy by the synergism effect of chlorine and phosphorus groups exhibited.

A Study on the Fatigue Failure Behavior of Cheon-Ho Mt. Limestone Under Cyclic Loading (천호산 석회암의 반복하중에 의한 피로파괴거동에 관한 연구)

  • Lee, Jong-Uk;Rhee, Chan-Goo;Kim, Il-Jung;Kim, Yeong-Seok
    • Nuclear Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.98-109
    • /
    • 1992
  • In this study uniaxial cyclic loading tests were performed on Cheon-Ho Mt. Limestone specimens to investigate the fatigue failure behavior. The loading rate was kept constantly at 760kg/$\textrm{cm}^2$/sec under cyclic loading. In order to reveal the fatigue behavior for each rock type, the test results were mutually compared with previous studies carried out on Indiana Limes-tone and Seong-Ju Sandstone. Fatigue data is presented in the form of S-N curves, which illustrate the relationship of maximum applied stress(S) to the number of cycles(N) required to produce failure. For the purpose of comparing the S-N curves for each rock type, the test data were formulated up to 10$^4$cycles and the correlation coefficients(R) on Cheon-Ho Mt. Limestone and Seong-Ju Sandstone specimen are 0.886 and 0.983, respectively. All three rock specimens were found to have shorter fatigue life at higher applied stress levels. The fatigue life for each rock type was considered as no less than 81.5, 70 and 74.8%, for Cheon-Ho Mt. Limestone, Indiana Limestone and Seong-Ju Sandstone, respectively. The comparison in static strength for monotonic loaded specimens and specimens which did not fail even after 10$^4$cycles indicated that the increasing rate of strength was about 6.18 and 10.96% , for Cheon-Ho Mt. Limestone and Indiana Limestone, respectively. Poisson's ratio and volumetric strain for Cheon-Ho Mt. Limestone and Seong-ju Sandstone, tended in all the cases to rapidly increase at higher stress levels and with an increase in number of cycles. This increasing trend becomes rapid and obvious just before failure. Also Poisson's ratio and volumetric strain for each stress level were compared and analyzed at the first cycle and the cycle prior to failure.

  • PDF

Performance Enhancement of 3-way Doherty Power Amplifier using Gate and Drain bias control (Gate 및 Drain 바이어스 제어를 이용한 3-way Doherty 전력증폭기와 성능개선)

  • Lee, Kwang-Ho;Lee, Suk-Hui;Bang, Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.77-83
    • /
    • 2011
  • In this thesis, 50W Doherty amplifier was designed and implemented for Beyond 3G's repeater and base-station. Auxiliary amplifier of doherty amplifier was implemented by Gate bias control circuit. Though gate bias control circuit solved auxiliary's bias problem, output characteristics of doherty amplifier was limited. To enhance the output characteristic relativize Drain control circuit And To improve power efficiency make 3-way Doherty power amplifier. therefore, 3-way GDCD (Gate and Drain bias Control Doherty) power amplifier is embodied to drain bias circuit for General Doherty power amplifier. The 3-way GDCD power amplifier composed of matching circuit with chip capacitor and micro strip line using FR4 dielectric substance of specific inductive capacity(${\varepsilon}r$) 4.6, dielectric substance height(H) 30 Mills, and 2.68 Mills(2 oz) of copper plate thickness(T). Experiment result satisfied specification of amplifier with gains are 57.03 dB in 2.11 ~ 2.17 GHz, 3GPP frequency band, PEP output is 50.30 dBm, W-CDMA average power is 47.01 dBm, and ACLR characteristics at 5MHz offset frequency band station is -40.45 dBc. Especially, 3-way DCHD power amplifier showed excellence efficiency performance improvement in same ACLR than general doherty power amplifier.