• Title/Summary/Keyword: IIP3

Search Result 130, Processing Time 0.033 seconds

A Dual-Mode 2.4-GHz CMOS Transceiver for High-Rate Bluetooth Systems

  • Hyun, Seok-Bong;Tak, Geum-Young;Kim, Sun-Hee;Kim, Byung-Jo;Ko, Jin-Ho;Park, Seong-Su
    • ETRI Journal
    • /
    • v.26 no.3
    • /
    • pp.229-240
    • /
    • 2004
  • This paper reports on our development of a dual-mode transceiver for a CMOS high-rate Bluetooth system-onchip solution. The transceiver includes most of the radio building blocks such as an active complex filter, a Gaussian frequency shift keying (GFSK) demodulator, a variable gain amplifier (VGA), a dc offset cancellation circuit, a quadrature local oscillator (LO) generator, and an RF front-end. It is designed for both the normal-rate Bluetooth with an instantaneous bit rate of 1 Mb/s and the high-rate Bluetooth of up to 12 Mb/s. The receiver employs a dualconversion combined with a baseband dual-path architecture for resolving many problems such as flicker noise, dc offset, and power consumption of the dual-mode system. The transceiver requires none of the external image-rejection and intermediate frequency (IF) channel filters by using an LO of 1.6 GHz and the fifth order onchip filters. The chip is fabricated on a $6.5-mm^{2}$ die using a standard $0.25-{\mu}m$ CMOS technology. Experimental results show an in-band image-rejection ratio of 40 dB, an IIP3 of -5 dBm, and a sensitivity of -77 dBm for the Bluetooth mode when the losses from the external components are compensated. It consumes 42 mA in receive ${\pi}/4-diffrential$ quadrature phase-shift keying $({\pi}/4-DQPSK)$ mode of 8 Mb/s, 35 mA in receive GFSK mode of 1 Mb/s, and 32 mA in transmit mode from a 2.5-V supply. These results indicate that the architecture and circuits are adaptable to the implementation of a low-cost, multi-mode, high-speed wireless personal area network.

  • PDF

The Effect of Right Stellate Ganglion Block on Hemodynamics following Endotracheal Intubation (우측 성상 신경절 차단이 기관내 삽관에 따른 심혈관계 반응에 미치는 영향)

  • Oh, Soo-Won;Koo, Gill-Hoi
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.58-63
    • /
    • 1997
  • Background : Endotracheal intubation is one of the methods most securely establishing airway. But accompanying hemodynamic responses are harmful to coronary or cerebral vascular disease patients. These hemodynamic responses are regarded as the results of sympathetic stimulation due to pharyngolaryngeal stimulation, and sympathetic blocking method-stellate ganglion block- may be obtundate these hemodynamic responses. Methods : 75 patients of ASA physical status I-II were selected. There were 40 patients normotensive (Group I), 35 patients hypertensive (Group II) Group I, steliate ganglion block was performed on 20 patients (Group I-S) the remainder had no procedure (Group I-O). Group II, 18 patients received SG3 (Group II-S), 17 patients had no procedure (Group II-O). SGB was performed with 1% lidocaine 8 ml on right stellate genglion after patient's consent. Blood pressure (IIP) and pulse rate(PR) were first measured in the pre-anesthesia room. Follow up BP and PR are checked immediately following SGB and every 5 minutes for subsequent 20 minutes, then after arrival at operatig room, then immediately after intubation and at 3, 5, 10, 15 and 20 minutes after incubation. Results : All group experienced significantly increased blood pressure and pulse rate upon arrival at the pre-anesthesetic and opeating rooms, as compared to when patients rates in the ward. After intubation and for subsequent 5 minutes, significant changes were measured. Patients then recovered to preblock value. In Group I, no statistical significance was recorded between subgroup I-S and I-O. However in Group II, there were significant differences between sub-group II-S and II-O. In evaluating pulse rate changes, there were no significant differences between Group I-S and I-O; nor II-S and II-O. Conclusion : The proper diagnosis of Stellate Ganglion Block had some measure of protective effect on hemodynamics following endotracheal intubation, especially in hypertensive patients.

  • PDF

Design of a 2.4-GHz Fully Differential Zero-IF CMOS Receiver Employing a Novel Hybrid Balun for Wireless Sensor Network

  • Chang, Shin-Il;Park, Ju-Bong;Won, Kwang-Ho;Shin, Hyun-Chol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • A novel compact model for a five-port transformer balun is proposed for the efficient circuit design of hybrid balun. Compared to the conventional model, the proposed model provides much faster computation time and more reasonable values for the extracted parameters. The hybrid balun, realized in $0.18\;{\mu}m$ CMOS, achieves 2.8 dB higher gain and 1.9 dB lower noise figure than its passive counterpart only at a current consumption of 0.67 mA from 1.2 V supply. By employing the hybrid balun, a differential zero-IF receiver is designed in $0.18\;{\mu}m$ CMOS for IEEE 802.15.4 ZigBee applications. It is composed of a differential cascode LNA, passive mixers, and active RC filters. Comparative investigations on the three receiver designs, each employing the hybrid balun, a simple transformer balun, and an ideal balun, clearly demonstrate the advantages of the hybrid balun in fully differential CMOS RF receivers. The simulated results of the receiver with the hybrid balun show 33 dB of conversion gain, 4.2 dB of noise figure with 20 kHz of 1/f noise corner frequency, and -17.5 dBm of IIP3 at a current consumption of 5 mA from 1.8 V supply.

Highly Linear Wideband LNA Design Using Inductive Shunt Feedback

  • Jeong, Nam Hwi;Cho, Choon Sik;Min, Seungwook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.100-108
    • /
    • 2014
  • Low noise amplifier (LNA) is an integral component of RF receiver and frequently required to operate at wide frequency bands for various wireless system applications. For wideband operation, important performance metrics such as voltage gain, return loss, noise figure and linearity have been carefully investigated and characterized for the proposed LNA. An inductive shunt feedback configuration is successfully employed in the input stage of the proposed LNA which incorporates cascaded networks with a peaking inductor in the buffer stage. Design equations for obtaining low and high impedance-matching frequencies are easily derived, leading to a relatively simple method for circuit implementation. Careful theoretical analysis explains that input impedance can be described in the form of second-order frequency response, where poles and zeros are characterized and utilized for realizing the wideband response. Linearity is significantly improved because the inductor located between the gate and the drain decreases the third-order harmonics at the output. Fabricated in $0.18{\mu}m$ CMOS process, the chip area of this wideband LNA is $0.202mm^2$, including pads. Measurement results illustrate that the input return loss shows less than -7 dB, voltage gain greater than 8 dB, and a little high noise figure around 6-8 dB over 1.5 - 13 GHz. In addition, good linearity (IIP3) of 2.5 dBm is achieved at 8 GHz and 14 mA of current is consumed from a 1.8 V supply.

A Fully Digital Automatic Gain Control System with Wide Dynamic Range Power Detectors for DVB-S2 Application (넓은 동적 영역의 파워 검출기를 이용한 DVB-S2용 디지털 자동 이득 제어 시스템)

  • Pu, Young-Gun;Park, Joon-Sung;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.58-67
    • /
    • 2009
  • This paper presents a fully digital gain control system with a new high bandwidth and wide dynamic range power detector for DVB-S2 application. Because the peak-to-average power ratio (PAPR) of DVB-S2 system is so high and the settling time requirement is so stringent, the conventional closed-loop analog gain control scheme cannot be used. The digital gain control is necessary for the robust gain control and the direct digital interface with the baseband modem. Also, it has several advantages over the analog gain control in terms of the settling time and insensitivity to the process, voltage and temperature variation. In order to have a wide gain range with fine step resolution, a new AGC system is proposed. The system is composed of high-bandwidth digital VGAs, wide dynamic range power detectors with RMS detector, low power SAR type ADC, and a digital gain controller. To reduce the power consumption and chip area, only one SAR type ADC is used, and its input is time-interleaved based on four power detectors. Simulation and measurement results show that the new AGC system converges with gain error less than 0.25 dB to the desired level within $10{\mu}s$. It is implemented in a $0.18{\mu}m$ CMOS process. The measurement results of the proposed IF AGC system exhibit 80-dB gain range with 0.25-dB resolution, 8 nV/$\sqrt{Hz}$ input referred noise, and 5-dBm $IIP_3$ at 60-mW power consumption. The power detector shows the 35dB dynamic range for 100 MHz input.

A Medium Power Single-Pole-Double-Throw MMIC Switch for IEEE 802.11a WLAN Applications (IEEE 802.11a 무선랜용 중간전력 SPDT 초고주차단일집적회로 스위치 제작 및 특성)

  • Mun JaeKyoung;Kim Haecheon;Park Chong-Ook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10A
    • /
    • pp.965-970
    • /
    • 2005
  • In this paper, SPDT Tx/Rx MMIC switch applicable to IEEE 802.11a WLAN systems is designed and fabricated using a specific designed epitaxial layered pHEMT wafer and ETRI's $0.5{\mu}m$ pHEMT switch process. The SPDT switch exhibits a low insertion loss of 0.68dB, high isolation of 35.64dB, return loss of 13.4dB, power transfer capability of 25dBm, and 3rd order intercept point of 42dBm at frequency of 5.8GHz and control voltage of 0/-3V. The comparison of the measured performances with commercial products based on the GaAs pHEMT technology for low voltage operating at ${\pm}$ 3V/0V shows that the return loss is somewhat inferior to the commercial products and insertion loss is compatible with each other however, isolation characteristics are much better than in conventional chips. Based on these performances, we can conclude that the developed SPDT switch MMIC has an enough potential for IEEE802.11a standard 5 GHz-band wireless LAN applications.

Reconfigurable CMOS low-noise amplifier for multi-mode/multi-band wireless receiver (다중모드/다중대역 무선통신 수신기를 위한 재구성 가능 CMOS 저잡음 증폭기)

  • Hwang, Bo-Hyun;Jung, Jae-Hoon;Kim, Shin-Nyoung;Jeong, Chan-Young;Lee, Mi-Young;Yoo, Chang-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.111-117
    • /
    • 2006
  • Reconfigurable CMOS low-noise amplifier (LAN) has been developed for multi-mode/multi-band wireless receiver. By employing common-gate input stage, the performance can be optimized for multiple operation bands by simply controlling the output load impedance. Although the conventional common-gate LAN has larger than 3dB noise figure (NF), the newly developed negative feedback scheme enables the common-gate input LNA to have less than 2dB NF. To have optimum linearity performance of wireless receiver, the gain of the LNA can be controlled. The LNA implemented in a 0.13mm CMOS technology shows $19{\sim}20dB$ voltage gain, $1.7{\sim}2.0dB$ NF, -2dBm iIP3 at $1.8{\sim}2.5GHz$ frequency range. The LNA dissipates 7mW from a 1.2V supply voltage.

Design of pHEMT channel structure for single-pole-double-throw MMIC switches (SPDT 단일고주파집적회로 스위치용 pHEMT 채널구조 설계)

  • Mun Jae Kyoung;Lim Jong Won;Jang Woo Jin;Ji, Hong Gu;Ahn Ho Kyun;Kim Hae Cheon;Park Chong Ook
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.207-214
    • /
    • 2005
  • This paper presents a channel structure for promising high performance pseudomorphic high electron mobility transistor(pHEMT) switching device for design and fabricating of microwave control circuits, such as switches, phase shifters, attenuators, limiters, for application in personal mobile communication systems. Using the designed epitaxial channel layer structure and ETRI's $0.5\mu$m pHEMT switch process, single pole double throw (SPDT) Tx/Rx monolithic microwave integrated circuit (MMIC) switch was fabricated for 2.4 GHz and 5 GHz band wireless local area network (WLAN) systems. The SPDT switch exhibits a low insertion loss of 0.849 dB, high isolation of 32.638 dB, return loss of 11.006 dB, power transfer capability of 25dBm, and 3rd order intercept point of 42dBm at frequency of 5.8GHz and control voltage of 0/-3V These performances are enough for an application to 5 GHz band WLAN systems.

The Efficacy of Interferon(IFN)-${\gamma}$ in Idiopathic Pulmonary Fibrosis (특발성 폐섬유화증에서 Interferon-${\gamma}$의 효과)

  • Park, Joo Hun;Oh, Yeon Mok;Shim, Tae Sun;Lim, Chae-Man;Koh, Younsuck;Lee, Sang-Do;Kim, Woo Sung;Kim, Won Dong;Kim, Dong Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.611-618
    • /
    • 2004
  • Background : Idiopathic pulmonary fibrosis(IPF), a subtype of IIP(idiopathic interstitial pneumonia), is a fatal disease with a 3-5 year median survival. Many attempts at treating this condition have failed to demonstrate a survival benefit in IPF. Recently Ziesche et $al^{12}$ reported the efficacy of IFN-${\gamma}$ for treating IPF but there is still some controversy. The aim of this study was to determine the efficacy of IFN-${\gamma}$ in patients with advanced IPF who had not been responsive to steroid and cytotoxic agents. Method : Nine patients with advanced IPF(age: $55.4{\pm}15.3$ years, Male: Female=8:1) were enrolled. One year treatment regime with 2 million IU of IFN-${\gamma}$ administered subcutaneously three times a week, and low dose prednisolone(10-30 mg/d) was also used. In the case of a definite aggravation and serious side effects, the IFN-${\gamma}$ was discontinued. During the IFN-${\gamma}$ trial, a pulmonary function test and chest radiography were checked every three month throughout the study. Result : 1) Among 9 patients, only 4 patients were able to complete the 12 month treatment with IFN-${\gamma}$, and 5 patients died during the treatment period. 2) No improvement either in the respiratory symptoms or pulmonary functions were observed any of the patients, even in those who completed the 12 months trial of IFN-${\gamma}$, 3) At the time of IFN-${\gamma}$ trial, the survivors who finished the IFN-${\gamma}$ treatment for 12 months had a higher oxygen level($81.3{\pm}2.8$ vs. $67.4{\pm}8.4$, P=0.024) and a better pulmonary function(FVC: $61.3{\pm}5.1$ % predicted vs. $45.7{\pm}12.3%$, P=0.048, and $D_Lco$: $45.0{\pm}5.0%$ predicted vs. $30.8{\pm}11.2%$, P=0.048) than the non-survivors. Conclusion : Our data suggested that IFN-${\gamma}$ therapy was not effective in the patients with advanced IPF refractory compared with other therapeutic agents. Furthermore, these results suggest that severe impairment of the pulmonary function and hypoxemia during the IFN-${\gamma}$ therapy requires special attention.

Compilation of 104 Experimental Theses on the Antitumor and Immuno-activating therapies of Oriental Medicine (한의학의 항종양 면역치료에 관한 연구 -1990년 이후 발표된 실험논문을 중심으로-)

  • Kang Yeon Yee;Kim Tai Im;Park Jong Ho;Kim Sung Hoon;Park Jong Dai;Kim Dong Hee
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.1
    • /
    • pp.1-24
    • /
    • 2003
  • This study was done to compile 104 experimental theses which are related to the antitumor and immuno-activating therapies between February 1990 through February 2002. Master's and doctoral theses were dassified by schools, degrees, materials, effects, experimental methods of antitumor and immunoactivity, and results. The following results were obtained from this study : 1. Classifying the theses by the school, 34.6% were presented by Daejeon University, 29.8% by Kyung-hee University and 11.5% by Won-kwang University. Of all theses, 51.0% were aimed for the doctoral degree and 43.3% were for the master's degree. All of three universities have their own cancer centers. 2. Classifying the theses by herb materials, complex prescription accounted for 60.3%, single herb accounted for 24.8% and herbal acupuncture accounted for 14.2%. Considering the key principles of the traditional medicine, complex prescription was much more thoroughly studied than single herb prescription. The results showed that the complex prescription had both antitumor activity and immuno-activating activity, which might reflects on multi-activation mechanisms by complex components. 3. Classifying the theses by the efficacy of herbs examined, in single herb, invigorating spleen and supplementing was 35.5%, expelling toxin and cooling was 29.0%, activating blood flow and removing blood stasis was 12.9%. In herbal acupuncture, invigorating spleen and supplementing was 52.9%, expelling toxin and cooling was 29.4%. In complex prescription, pathogen-free status was 41.9%, strengthening healthy qi to eliminate pathogen was 35.5%, strengthening healthy qi was 22.6%. It is presumed that the antitumor and immunoactivating therapy based on syndrome differentiation is the best way to develop oriental oncology. 4. Classifying the theses by antitumor experiments, cytotoxic effect was 48.1 %, survival time was 48.1 % and change of tumor size was 42.3%. Survival rate was not necessarily correlated with cytotoxicity. These data reflect the characteristic, wholistic nature of the oriental medicine which is based on BRM (biological response modifier). 5. Classifying the theses by immunoactivating experiments, hemolysin titer was 51.0%, hemagglutinin titer was 46.2% and NK cell's activity was 44.2%. In the future studies, an effort to elucidate specific molecular and cellular mechanisms of cytokine production in the body would be crucial. 6. Classifying the theses according to the data in terms of antitumor activity, 50% was evaluated good, 24.0% was excellent, and 15.5% have no effect. In an evaluation of immuno-activating activity, 35.9% was excellent and 18.0% showed a little effect. The index point, as described here, may helps to use experimental data for clinical trials. Changes in index points by varying dosage implicate the importance of oriental medical theory for prescription. 7. In 167 materials, IIP (immunoactivating index point, mean : 3.12±0.07) was significantly higher than AIP(antitumor index point, mean : 2.83±0.07). These data demonstrate that the effect of herb medicine on tumor activity depends more on immunoactivating activity than antitumor activity. This further implies that the development of herbal antitumor drugs must be preceded by the mechanistic understanding of immunoactivating effect. 8. After medline-searching tumor and herb-related articles from NCBI web site, we conclude that most of the studies are primarily focused on biomolecular mechanisms and/or pathways. Henceforth, we need to define the biomolecular mechanisms and/or pathways affected by herbs or complicated prescriptions. 9. Therefore, the most important point of oriental medical oncology is to conned between experimental results and clinical trials. For the public application of herbal therapy to cancer, it is critical to present the data to mass media. 10. To develop the relationship of experimental results and clinical trials, university's cancer clinic must have a long-range plan related to the university laboratories and, at the same time, a regular consortium for this relationship is imperative. 11. After all these efforts, a new type herbal medicine for cancer therapy which is to take care of the long-term administering and safety problem must be developed. Then, it would be expected that anti-tumor herbal acupuncture can improve clinical symptoms and quality of life (QOL) for cancer patients. 12. Finally, oriental medical cancer center must be constructed in NCC (National Cancer Center) or government agency for the development of oriental medical oncology which has international competitive power.