• 제목/요약/키워드: IHN

검색결과 813건 처리시간 0.032초

주게원자로 산소와 질소를 포함하는 거대고리 리간드로 변성된 탄소반죽전극에 의한 Ag(I) 이온의 전압-전류법적 정량 (Voltammetric Determination of Ag(I) ion with Carbon Paste Electrode Modified with Macrocyclic Ligand Containing Oxygen and Nitrogen as Ligating Atoms)

  • 이인종
    • 분석과학
    • /
    • 제15권1호
    • /
    • pp.91-95
    • /
    • 2002
  • Carbon paste electrodes, modified with 5,6,14,15-dibenzo-1,4-dioxa-8,12-diazacyclopentadeca-5,14-diene containing different ligating atoms of oxygen and nitrogen, have been employed for the voltammetric determination of Ag(I) ion from aqueous solution. The voltammetric response was characterized with respect to paste composition, preconcentration method, kind of anion, variation of pH, Ag(I) ion concentration, and possible interferences. Linear calibration curves were obtained for Ag(I) ion concentration ranging from $3.0{\times}10^{-6}M$ to $8.0{\times}10^{-5}M$, and detection limit was $8.5{\times}10^{-7}M$.

최적 Type-2 퍼지신경회로망 설계와 응용 (The Design of Optimized Type-2 Fuzzy Neural Networks and Its Application)

  • 김길성;안인석;오성권
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1615-1623
    • /
    • 2009
  • In order to develop reliable on-site partial discharge (PD) pattern recognition algorithm, we introduce Type-2 Fuzzy Neural Networks (T2FNNs) optimized by means of Particle Swarm Optimization(PSO). T2FNNs exploit Type-2 fuzzy sets which have a characteristic of robustness in the diverse area of intelligence systems. Considering the on-site situation where it is not easy to obtain voltage phases to be used for PRPDA (Phase Resolved Partial Discharge Analysis), the PD data sets measured in the laboratory were artificially changed into data sets with shifted voltage phases and added noise in order to test the proposed algorithm. Also, the results obtained by the proposed algorithm were compared with that of conventional Neural Networks(NNs) as well as the existing Radial Basis Function Neural Networks (RBFNNs). The T2FNNs proposed in this study were appeared to have better performance when compared to conventional NNs and RBFNNs.

Systems Engineering Method to Develop Multiple BMI Nozzle Inspection System for APR1400

  • Abdallah, Khaled Atya Ahmed;Nam, GungIhn
    • 시스템엔지니어링학술지
    • /
    • 제12권1호
    • /
    • pp.25-40
    • /
    • 2016
  • The Systems Engineering (SE) approach is characterized by the application of a structured engineering methodology for the design of a complex system or component. In this study, the SE methodology is used to design a nondestructive inspection system for Bottom Mounted Instrumentation (BMI) nozzles. We developed a system that enables nondestructive inspection of BMI nozzles during regular refueling outage without removing the reactor internals. A special ultrasonic (UT) probe is introduced to scan and detect cracks within the weld region of the nozzle. A 3D model of the inspection structure system was developed along with the reactor pressure vessel (RPV) and internals which permits a virtual 3D simulation of the operation to check the design concept and effectiveness of the system and to provide a good visualization of the system. This approach allows for a virtual walk through to verify the proposed BMI nozzle inspection system.

광센서 기반 휴대형 침윤 조기 감지기 개발 (A Development of Portable Early Detector of Intravenous Infiltration based on Optical Sensor)

  • 이성진;신범주;정인숙
    • 한국멀티미디어학회논문지
    • /
    • 제21권6호
    • /
    • pp.705-711
    • /
    • 2018
  • Intravenous(IV) therapy being in use for many patients may cause serious side effects such as infiltration, extravasation. To minimize such side effects, it is important to detect symptoms appearing when fluid escapes from blood vessel to tissue as soon as possible. This paper describes a device which has been developed to detect IV infiltration early using optical sensor. The device detects IV infiltration as measuring intensity of lights reflected from that lights after emitting lights in IV therapy site. The lights are consisted of 4 different waves which provide different reflection ratio depending the fluid used in IV therapy. The experimental results show that the device can be used to detect IV infiltration early.

제조공기를 이용한 Rod전극의 절연파괴특성 (Breakdown Characteristics of Rod-Electrodes using Imitation Air)

  • 송재우;장세우;안인석;장준오
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.16-20
    • /
    • 2013
  • In this paper the experiments of breakdown characteristics by pressure and gap change of imitation air were described. The results are fundamental data for electric insulation design of distribution power facilities which will be studied and developed in the future. And we could make an environment friendly gas insulation material with mataining dielectric strength by Imitation Air which generates a lower lever of the global warming effect.

디지털보호계전기를 활용한 전력감시제어시스템 설계 (A Design of Power Management and Control Systems Using Digital Protective Relays)

  • 이성환;안인석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.191-193
    • /
    • 2000
  • In this paper, being different from traditional methods, we design digital protective relay which can be applied to power management and control systems of not only small and medium but also a large scale plants. The digital protective relay was designed with DSP CPU(TMS320C31) to protect and measure more quickly and precisely. We will present test result which it performed according to the standards of Korea Electrical Manufactures Cooperative to prove the faculties of digital protective relay. The test result on the basis of KEMC1120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within ${\pm}5%$.

  • PDF

Pd-SiC 쇼트키 다이오드의 수소 가스 감지 특성 (A Study on a Palladium-Silicon Garbide Schottky Diode as a Hydrogen Gas Sensor)

  • 이주헌;이영환;김창교;조남인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.858-860
    • /
    • 1998
  • A Pd-SiC Schottky diode for detection of hydrogen gas operating at high temperature was fabricated. Hydrogen-sensing behaviors of Pd-SiC Schottky diode have been analyzed as a function of hydrogen concentration and temperature by I-V and ${\Delta}I$-t methods under steady-state and transient conditions. The effect of hydrogen adsorption on the barrier height was investigated. Analysis of the steady-state kinetics using I-V method confirmed that the atomistic hydrogen adsorption process is responsible for the barrier height change in the diode.

  • PDF