• 제목/요약/키워드: IGBT Inverter

검색결과 306건 처리시간 0.022초

정현파(正弦波) 출력(出力) PAM형(形) IGBT 인버터에 관한 연구(硏究) (A Study on IGBT inverter for sinusoidal wave output PAM type)

  • 이현우;박종기;이수흠;권순걸;서기영;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.611-614
    • /
    • 1991
  • In variable speed driving system of three phase induction motor controlled by an inverter, because of the switching of semiconductor devices in inverter, an appreciable amount of harmonic components of voltage waveform can cause the motor to generate losses, torque ripple, acoustic noise and oscillation of semiconductor devices. In this paper a new PAM type PWM inverter using IGBT is described. The output waveforms in the proposed PAM type PWM inverter are investigated both theoretiically and experimentally. The line-voltage waveform is composed of fundamental component and the sidebands of carrier frequency. The lower order harmonics are not included in the output wave form. As each inverter arm does not operate during two-thirds period, the heats, generated in the devices are reduced. That is, the size of the inverter system can he minimized because of the reduction in the heat dissipating equipment.

  • PDF

A Single-Phase Cell-Based Asymmetrical Cascaded Multilevel Inverter

  • Singh, Varsha;Pattnaik, Swapnajit;Gupta, Shubhrata;Santosh, Bokam
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.532-541
    • /
    • 2016
  • A single-phase asymmetrical cascaded multilevel inverter is introduced with the goal of increasing power quality with the reduction of power in insulated-gate bipolar transistor (IGBT) switches. In the present work, the proposed inverter topology is analyzed and generalized with respect to different proposed algorithms for choosing different voltage source values. To prove the advantages of the proposed inverter, a case study involving a 17-level inverter is conducted. The simulation and experimental results with reduced THD are also presented and compared with the MATLAB/SIMULINK simulation results. Finally, the proposed topology is compared with different multilevel inverter topologies available in the literature in terms of the number of IGBT switches required with respect to the number of levels generated in the output of inverter topologies.

산업용 인버터 구동을 위한 고효율 고내압 Field-stop IGBT 최적화 설계에 관한 연구 (Study on Industrial Inverters for Driving High-efficiency High-voltage Field-stop IGBT Optimization Design)

  • 이명환;김범준;정은식;정헌석;강이구
    • 한국전기전자재료학회논문지
    • /
    • 제26권4호
    • /
    • pp.257-263
    • /
    • 2013
  • In this paper, Solar, Wind, fuel cell used in a Power conversion devices and industrial inverter motor to increase the efficiency of energy consumption, which is a core part of high-efficiency, high-voltage Trench Gate Field Stop IGBT was studied. For this purpose Planar type NPT IGBT and Planar type Field Stop IGBT have designed a basic structure designed to Trench Gate Field Stop IGBT based on the completed structure by analyzing the energy consumption of electrical characteristics, efficiency is a key part, high-efficiency and high-voltage inverter for industry regarding the optimization design for Trench Gate Field Stop IGBT.

유도가열 증기발생장치의 온도제어 (A Study on the Temperature Control of Vapor System Using Induction Heating)

  • 신대철;유재훈
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.117-123
    • /
    • 2010
  • 제안한 유도가열 시스템은 증류탑 장치에 사용되는 특수적층 규칙충진체에 의한 열 교환기술과 IH(Induction-Heating)전자유도가열용의 특수한 고주파 전력회로 기술을 응용한 차세대 가열방식이다. 본 전자유도 유체가열기술은 IGBT대응의 고주파 인버터를 사용하여 상용교류로부터 수[kHz]의 고주파 교류를 발생시킬 수 있다. 공진형 고주파 인버터를 사용함으로 고성능, 고효율의 시스템화가 가능하다. 본 논문에서는 주파수 범위가 20[kHz]에서 44[kHz]인 고주파 공진형 인버터을 이용하여 증기를 발생시키는 유도가열시스템에 대해 제안한 온도제어에 대하여 기술하고자 한다.

New Resonant AC Link Snubber-Assisted Three-Phase Soft-Switching PWM Inverter and Its Comparative Characteristics Evaluations

  • Yoshida, Masanobu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.239-248
    • /
    • 2003
  • This paper presents a novel prototype of three-phase voltage source type zero voltage soft-switching inverter with the auxiliary resonant snubbers suitable for high-power applications with IGBT power module packages in order to reduce their switching power losses as well as electromagnetic conductive and radiative noises. A proposed single inductor-assisted resonant AC link snubber circuit topology as one of some auxiliary resonant commutation snubbers developed previously to achieve the zero voltage soft-switching (ZVS) for the three-phase voltage source type sinewave PWM inverter operating under the instantaneous space voltage vector modulation is originally demonstrated as compared with the other types of resonant AC link snubber circuit topologies. In addition to this, its operation principle and unique features are described in this paper. Furthermore, the practical basic operating performances of the new conceptual instantaneous space voltage vector modulation resonant AC link snubber-assisted three-phase voltage source type soft-switching PWM inverter using IGBT power module packages are evaluated and discussed on the basis of switching voltage and current waveforms, output line to line voltage quality, power loss analysis, actual power conversion efficiency and electromagnetic conductive and radiative noises from an experimental point of view, comparing with those of conventional three-phase voltage source hard-switching PWM inverter using IGBT power modules.

부산도시철도 2호선 VVVF 인버터 개량 연구 (A study on refurbishing VVVF Inverter for train of Busan metro line 2)

  • 황현규;박희철;이은규;권선범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1407-1413
    • /
    • 2011
  • This paper studied on the VVVF Inverter for 1C4M propulsion system of railway traction. The paper includes the comparison along a VVVF Inverter electric power conversion element for an electric railcar(GTO, IGBT). These inverters are composed of high power IGBTs and controlled by compact control units. The stack is simplified and optimized by using plate bus and IGBT driver units of hybrid-type.

  • PDF

Diagnosis Methods for IGBT Open Switch Fault Applied to 3-Phase AC/DC PWM Converter

  • Im, Won-Sang;Kim, Jang-Sik;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.120-127
    • /
    • 2012
  • Fault diagnosis technique of electrical drives is becoming more and more important, since voltage fed converter system has become industrial standard in many applications. Many studies have been conducted an inverter fault diagnosis for induction motors. However, there are few researches about fault diagnosis of 3-phase ac/dc PWM (Pulse Width Modulation) converter compared to the dc/ ac inverter. The ac/dc converter is the opposite of dc/ac inverter at current flow. Also, inverter and converter have different current patterns under the same condition of IGBT (Insulated gate bipolar transistor) open switch fault. Therefore, it is difficult to apply intact diagnosis methods of inverter to the converter. This paper proposes modified fault detection methods for IGBT open switch fault in 3-phase ac/dc PWM converter by modifying established fault diagnostic methods for dc/ac inverters.

Detection and Diagnosis Solutions for Fault-Tolerant VSI

  • Cordeiro, Armando;Palma, Joao C.P.;Maia, Jose;Resende, Maia J.
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1272-1280
    • /
    • 2014
  • This paper presents solutions for fault detection and diagnosis of two-level, three phase voltage-source inverter (VSI) topologies with IGBT devices. The proposed solutions combine redundant standby VSI structures and contactors (or relays) to improve the fault-tolerant capabilities of power electronics in applications with safety requirements. The suitable combination of these elements gives the inverter the ability to maintain energy processing in the occurrence of several failure modes, including short-circuit in IGBT devices, thus extending its reliability and availability. A survey of previously developed fault-tolerant VSI structures and several aspects of failure modes, detection and isolation mechanisms within VSI is first discussed. Hardware solutions for the protection of power semiconductors with fault detection and diagnosis mechanisms are then proposed to provide conditions to isolate and replace damaged power devices (or branches) in real time. Experimental results from a prototype are included to validate the proposed solutions.

전동차용 IGBT형 추진제어장치의 6호선 본선 만차 시험에 관한 연구 (A Study On Full Load Test of IGBT Type Propulsion System for Electric Railway in SMG 6 Line)

  • 박건태;정만규;고영철;방이석;서광덕
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.666-673
    • /
    • 2000
  • This paper describes the full load test results of IGBT VVVF inverter for the railway propulsion system. The 1,650kVA IGBT VVVF inverter has been developed. Therefore, the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T(4 Motor car 4 Trailer Car) and the electrical equipment for field test are as follows VVVF inverter 4 sets, 16 traction motors and 2 SIVs. The propulsion system is composed with IC4M(1-Controller 4-Motors). The results of propulsion system which have the excellent acceleration/deceleration and the jerk characteristics as well as starting ability on slope are taken through the field test.

  • PDF

철도차량용 추진제어장치의 진동시험방법에 관한 연구 (A study on vibration test methods for propulsion system of electric car)

  • 한영재;김길동;박현준;최성규;이우동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1439-1441
    • /
    • 2000
  • In this paper, for IGBT inverter of electric car studied new vibration test method. It made a partial amendment of the existing standard. Using new vibration test method is tested actually IGBT inverter. The result on vibration test for IGBT inverter shows an excellent performance.

  • PDF