• Title/Summary/Keyword: IEC61850

Search Result 214, Processing Time 0.04 seconds

A Security Nonce Generation Algorithm Scheme Research for Improving Data Reliability and Anomaly Pattern Detection of Smart City Platform Data Management (스마트시티 플랫폼 데이터 운영의 이상패턴 탐지 및 데이터 신뢰성 향상을 위한 보안 난수 생성 알고리즘 방안 연구)

  • Lee, Jaekwan;Shin, Jinho;Joo, Yongjae;Noh, Jaekoo;Kim, Jae Do;Kim, Yongjoon;Jung, Namjoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.75-80
    • /
    • 2018
  • The smart city is developing an energy system efficiently through a common management of the city resource for the growth and a low carbon social. However, the smart city doesn't counter a verification effectively about a anomaly pattern detection when existing security technology (authentication, integrity, confidentiality) is used by fixed security key and key deodorization according to generated big data. This paper is proposed the "security nonce generation based on security nonce generation" for anomaly pattern detection of the adversary and a safety of the key is high through the key generation of the KDC (Key Distribution Center; KDC) for improvement. The proposed scheme distributes the generated security nonce and authentication keys to each facilities system by the KDC. This proposed scheme can be enhanced to the security by doing the external pattern detection and changed new security key through distributed security nonce with keys. Therefore, this paper can do improving the security and a responsibility of the smart city platform management data through the anomaly pattern detection and the safety of the keys.

A Brief Introduction of A New Communication Architecture in Substation Automation System (변전소 자동화 시스템에 적용되는 새로운 통신 아키텍처에 관한 고찰)

  • You, Jeong-Sik;Choi, Dae-Hee;Kim, Hyung-Geun;Kim, Hong-Seok;Lee, Hak-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.180-182
    • /
    • 2002
  • 전력 시장의 자율 경쟁체제가 본격화되면서 기존 공급자 중심의 시장은 급격하게 사용자 중심의 시장으로 재편되어 가고 있다. 기존의 최소한의 '데이터'라는 개념은 최대한의 '정보'라는 개념으로 변화되었다. 정보의 신속하고 효율적인 관리는 변전소 자동화 시스템의 핵심 전략이자 이를 기반으로 한 전력 시스템의 IT화를 가속화시키는 원동력이 되었다. 외국의 경우 1990년대 초에 등장한 UCA2(Utility Communication Architecture)를 기반으로 한 IEC 61850(Communication Networks and systems in substation)이라는 새로운 통신 아키텍처의 도입을 서두르고 있다. IEC 61850은 IEC에서 추진중인 표준화작업의 일환으로 기존의 포인트와 태그(address) 중심의 전력 SCADA 시스템과는 달리 디바이스 및 관련 정보를 데이터 클래스 모델링을 통해 객체화하고 이 표준 객체를 통해 공통의 언어로 통신을 하는 방식으로 wire 중심이 아닌 bus 중심의 통신 방식(Ethernet)을 채용하여 대용량 정보의 실시간 전송 및 이기종간 통신이 가능한 장점을 가지고 있다. 본 논문에서는 IEC 61850을 중심으로 변전소 자동화 시스템 및 전력 시스템의 IT화와 관련된 표준 통신 프로토콜들을 소개하고 전력시스템과 변전소 환경이라는 특수 상황을 고려하여 새롭게 등장한 아키텍처의 특징을 살펴본다.

  • PDF

A Study of IED Configuration Tool using XML (XML을 이용한 IED Configuration Tool에 관한 연구)

  • Oh, Sung-Min;Hong, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.507-508
    • /
    • 2007
  • IEC 61850은 변전소자동화시스템에 대한 국제 표준 규격이다. IEC 61850 파트 6은 통신관련 IED(Intelligent Electronic Device) 구성과 IED 파라미터, 통신 시스템 구성, 개폐소 구조 및 이들 간의 관계를 설명하는 파일 형식을 규정한다. 이 파일 형식의 주요 목적은 IED 능력 설명, 호환되는 방법으로 여러 제조사들의 IED 엔지니어링 도구와 시스템 엔지니어링 도구 간의 SA 시스템 설명을 교환하는 것이다. 본 논문에서는 XML을 이용한 IED Configurator TOOl 구현을 제시하였다.

  • PDF

K-Grid Integrated Data Modeling and Data Exchange Protocol Design and Evaluation (K-Grid 통합 노드 데이터 모델링 및 정보교환 프로토콜 설계와 시험)

  • Choi, Jung-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.119-131
    • /
    • 2011
  • To be integrated into the IEC 61970-based K-Grid, application of open communication protocol and sub-system modeling to major nodes is needed. In this paper, a module which links load nodes in customers to CIM based on psXML/oBIX, one of open protocols, was developed and data modeling and communication protocols of IEC 61850-7-42 based DER and ESS which apply the module to the customers who have DER and ESS were designed. Also the XML-based distributed database middleware was designed. The proposed modeling and protocols were applied to the building in which commercial DER products and the effectiveness of the proposed data modeling and the communication protocol were evaluated.

Development of Bay Controller for 170kV GIS (170kV GIS용 Bay Controller 개발)

  • Kim, Min-Soo;Jung, Jung-Ryong;Kim, Jung-Bae;Lee, Hahk-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1324-1325
    • /
    • 2008
  • 근래 선진 중전기 메이커에서는 차단기, GIS 등의 전통적인 단품 위주에서 탈피하여 전력 IT 기술을 접목한 전력기기/변전소 자동화를 강력하게 추진하고 있다. 특히 전체 변전소를 감시, 제어, 계측, 보호할 수 있도록 전력 IT 기술을 기반으로 한 IEC 61850 적용 변전소 종합 자동화 시스템 개발에 역량을 집중하고 있다. 본 논문에서는 당사에서 개발한 최신 IT 기술을 적용한 IEC 61850 기반 170㎸ GIS용 Bay Controller 관련 구성, 기능, 성능시험 결과에 대해 기술하며, 변전소 내 노이즈로 인해 유발될 수 있는 전자장치 오동작 등을 보증하기 위해 실시한 전자파 장해시험 결과와 GIS와 동일한 환경에 설치되므로 온/습도, 진동/충격시험을 관련 국제규격인 IEC 60255-6, IEC 60255-21-1, 2, 3에 의거하여 실시한 내용을 기술하도록 한다.

  • PDF

A Study for the Message Exchange of the EVSE Communication Controller using XML Schema Transformation

  • Un, Koaunghi;Jang, Hyuksoo;Kim, Myongsoo;Kim, Hwimin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.71-81
    • /
    • 2016
  • An EVSE and the EV exchange XML formatted communication messages with each other, whose structure is described by the V2G CI schema in the ISO/IEC 15118 international standard, and the EVSE and the power grid exchange messages based on SCL file with each other, whose structure is described by SCL schema in the IEC 61850 international standard. Because XML files can be restructured by XSLT, V2G messages can be transformed to/from SCL files using XSLT. In this study, the two schemas are analyzed and compared in order for the restructuring of the two differently structured XML instances. As a result, two XSL scripts can be produced for the transformation between XML files conforming ISO/IEC 15118 V2G CI schema and IEC 61850 SCL schema respectively to avoid manual data mapping which can happen in every application development cases.

154kV Main TR. Bay IED Based On IEC-61850 (IEC-61850 기반의 154kV M.Tr Bay IED 적용 사례)

  • Roh, Jae-Keun;Oh, Jae-Hoon;Kim, Byoung-Choul;Ko, Choul-Jin;Yang, Hang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.764-765
    • /
    • 2011
  • 전력시스템을 더 효율적으로 운용하고, 더 지능화하려는 노력은 2000년대 초 다양한 각도로 진행되어 왔다. 그리하여 중장기 국책과제인 전력IT 과제를 필두로 여러 지능화 기기들이 국 내외 유관업체를 통하여 지속적으로 성장을 하였고 현재에 이르러서는 과제의 틀이 아닌 비즈니스 모델 창출을 위하여 여러 시범 사업들이 구상되고 있는 중이다. 이는 전력IT 의 핵심 아이템이라 할 수 있는 IEC-61850 국제 표준 프로토콜 기반의 IED (Intelligent Electronic Devices) 개발과 어울려 변전소의 직접 현장 적용을 통한 엔지니어링 기술 개발에 역점을 두고 있는 상태이다. 변전소 자동화 (S/A: Substation Automation)의 영역이 점점 현실화 되어가고, 전 세계 적용 Site의 폭발적인 증가로 힘입어 이젠 선택이 아닌 필수가 되고 있고, 적용에서 끝이 아닌 다양한 엔지니어링 Tool 의 개발, 진단 시스템의 융합 등과 더불어 계속 발전해나가고 있다. 본 논문에서는 이러한 시대적 흐름을 바탕으로 당사에서 참여중인 한국전력 154kV S/A 시범사업 및 스마트그리드 실증사업을 통하여 현장 적용된 154kV Main Transformer 용 IED 솔루션의 적용 사례를 소개하고자 한다. S/A 시범사업의 경우, 한국전력 충주본부 풍동S/S에서 올해 초 설계되어 현재 현장 엔지니어링을 1차 마무리한 상태이며, 스마트 그리드 실증사업은 제주 성산S/S에서 진행 중이며 이도 마무리를 하는 단계에 이르러, 그동안 현장적용의 문제점을 논의하고, 이에 대한 대응책을 서로 공유하며 정리하고 있다. 참고로 본 논문에서는 IEC-61850 프로토콜 구현에 대한 것은 다루지 않으며, 다만 현장제어에 필요하고 또한 구현되어 있는 기능에 대한 전반적인 내용을 다루게 된다.

  • PDF

Design of an Algorithm for the Validation of SCL in Digital Substations

  • Jang, B.T.;Alidu, A.;Kim, N.D.
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.89-97
    • /
    • 2017
  • The substation is a critical node in the power network where power is transformed in the power generation, transmission and distribution system. The IEC 61850 is a global standard which proposes efficient substation automation by defining interoperable communication and data modelling techniques. In order to achieve this level of interoperability and automation, the IEC 61850 (Part 6) defines System Configuration description Language (SCL). The SCL is an XML based file format for defining the abstract model of primary and secondary substation equipment, communications systems and also the relationship between them. It enables the interoperable exchange of data during substation engineering by standardizing the description of applications at different stages of the engineering process. To achieve the seamless interoperability, multi-vendor devices are required to adhere completely to the IEC 61850. This paper proposes an efficient algorithm required for verifying the interoperability of multi-vendor devices by checking the adherence of the SCL file to specifications of the standard. Our proposed SCL validation algorithm consists of schema validation and other functionalities including information model validation using UML data model, the Vendor Defined Extension model validation, the User Defined Rule validation and the IED Engineering Table (IET) consistency validation. It also integrates the standard UCAIUG (Utility Communication Architecture International Users Group) Procedure validation for quality assurance testing. Our proposed algorithm is not only flexible and efficient in terms of ensuring interoperable functionality of tested devices, it is also convenient for use by system integrators and test engineers.

Synchronized Sampling Structure applied HW/SW platform for LAN-based Digital Substation Protection (LAN 기반 디지털 변전소 보호를 위한 동기 샘플링 구조적용 HW/SW 플랫폼 기술)

  • Son, Kyou Jung;Nam, Kyung-Deok;An, Gi Sung;Chang, Tae Gyu
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.178-185
    • /
    • 2020
  • This paper proposes precise time synchronization-based synchronized sampling structure applied HW/SW platform for LAN-based protection of future digital substations. The integrated software of the proposed platform includes IEC 61850 protocol, IEEE 1588 precision time protocol and synchronized sampling structure. The proposed platform expected to provide a basis of an application of future distributed sensing data-based protection and control methods by providing synchronized measurement among IEDs. The implementation of the proposed HW/SW platform technique was performed using TMDXIDK572 multi-core/multi-processor evaluation module and its time synchronization performance and synchronized sampling function were confirmed through the performance tests.