• Title/Summary/Keyword: IEC 60364

Search Result 87, Processing Time 0.028 seconds

Comparison and Analysis of Domestic and Foreign Standard for electrical equipment installation of amusement park and ride (유원시설 전기설비 설치에 대한 국내외 규정 비교 분석)

  • Kim, Gi-Hyun;Kim, Chong-Min;Kim, Han-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.378-382
    • /
    • 2004
  • This paper gives information which is applied to install the electrical equipment of amusement park and ride. For analyzing the standard of electrical equipment installation, we research the related regulation of National Electrical Code(2002), IEC 60364-series and Technical standards for Electrical facilities of internal standard. Among electrical equipments of amusement park and ride, especially we study the transformer vaults, overcurrent protection and ground protection of electrical equipment. So we the furnished the installation information of transformer vaults, overcurrent and ground protection at amusement park and ride.

  • PDF

A Study on the Safety of Medical IT System connecting Medical Insulation Transformer in Medical Locations (의료용 절연변압기에 연결하는 의료 IT시스템의 안전에 관한 연구)

  • Kim, Se-Dong;Kim, Eun-Sik;Park, Jung-Il;Choi, Hyung-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.61-66
    • /
    • 2011
  • An accidental disconnection of power supply for operating theatres may result in fatal accidents. Thus, it is necessary to import the electric safety system in medical locations. This paper shows an analysis of simulation for the safety in medical IT system based on KS C IEC 60364-7-710(Electrical Installations of Buildings - Requirements for special installations or locations - Medical locations). The analysis was progressed by measuring leakage currents according to variation of volts, circuits and loads. And it was made database for calculation the reasonable length of branch circuit.

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.

Analysis of Fault Characteristics by the Type of Grounding Scheme in Low Voltage DC Distribution System (접지방식에 따른 저압 직류배전계통의 고장특성 분석)

  • Baek, In-Ho;Oh, Yun-Sik;Han, Joon;Kim, Doo-Ung;Gwon, Gi-Hyeon;Kim, Chung-Mo;Kim, Hyun-Soo;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.103-112
    • /
    • 2015
  • Recently, DC distribution system has come into the spotlight as the number of digital loads and the use of renewable energy increases. However, there are still challenges for the commercialization of DC distribution system such as a consideration for the safety. Thus, researches on protective coordination and grounding system for the safety of human bodies and facilities in Low-Voltage DC (LVDC) distribution system should be preferentially conducted. In this paper, therefore, we analyze characteristics of faults in LVDC system accroding to type of grounding system based on IEC 60364. Finally, the simulations for fault characteristic in different grounding scheme are conducted using ElectroMagnetic Transient Program(EMTP) and the results of simulation are shown.

Effects of Ground Faults on the Safety of Persons in High Voltage Distribution Systems (고압계통 지락고장시 인체안전에 미치는 영향)

  • Kang, Sung-Man;Kim, Han-Soo;Lee, Jong-Chul;Lee, Ju-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.195-197
    • /
    • 2007
  • This paper presents experimental results on the safety of persons due to a ground fault in 22.9 kV-Y distribution system In order to evaluate the touch voltages due to internal ground faults in a step down transformer based on the newly prescribed KS C IEC 60364 standard series, the verification tests in a 22.9 kV multi-grounded neutral system were carried out From the experimental results, it was found that there will be significant potential rise jeopardizing LV equipment insulation in case of separate grounding between HV and LV system and the effective measures against hazardous touch voltages due to a IN side ground fault in the common grounding system between HV and LV system are proposed. As a consequence, it was found that the equipotential bonding is an important prerequisite for the effectiveness of the protective measures for the safety of persons in the common ground system between 22.9 kV-Y and low-voltage grounding system.

  • PDF

Development of residual current detector for protecting human and equipment of TN grounding systems in DC power distribution systems (TN접지방식 직류배전에서의 인체 및 설비 보호를 위한 누설전류 검출기)

  • Lee, Won-Ki;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.64-65
    • /
    • 2014
  • 신재생에너지원의 급속한 보급, 고신뢰 및 고효율 전원망에 대한 고객의 요구, 디지털부하의 급증 등 기술적 사회적 환경의 변화에 따라 직류배전망에 대한 관심이 높아지고 있다. 이에 따라 직류배전망의 안전성에 대한 문제도 지속적으로 제기되고 있다. 특히 지락, 단락사고, 절연고장, 낙뢰, 아크, 전식 등으로부터 인체 감전과 기기의 소손, 정지 또는 오동작이 발생될 수 있으며 이로 인해 심각한 문제를 야기될 수 있다. 국제표준 IEC 60364에서는 전기설비에 따른 접지시스템을 TT, TN 및 IT접지의 3가지로 분류하고 있다. TN접지방식은 전원선과 설비외함의 노출 도전부를 보호도체를 사용하여 공통으로 접지하는 계통을 말한다. 따라서, 전원선이 외함에 접촉되거나 인체의 감전에 의한 누전사고가 발생하였을 때 전원선 전체를 통하여 흐르는 전류의 차이를 검출함으로서 사고전류의 검출이 즉각 이루어 질 수 있다. 교류계통에서는 영상전류검출기에 의하여 누설전류의 검출이 가능하지만 직류계통에서는 영상전류검출기를 사용할 수 없으므로 새로운 방식의 누전검출장치의 개발이 요구된다. 또한 감전 사고는 인체의 사고와 설비의 사고 두 가지로 구별되며, 효율적인 전력운영과 안전을 위하여 두가지 사고에 대해 통합적으로 구분 동작이 가능한 누설전류 검출기 개발이 요구된다. 본 연구에서는 TN접지계통에서 직류누설전류 검출이 가능한 홀 센서(HCT)를 사용하여 인체 및 설비의 누설전류 패턴에 따라 구분 동작이 가능한 직류용 누설전류 검출기 개발에 관한 연구를 수행하였다.

  • PDF

Analysis of on-site conditions of grounding methods installed in new buildings (신축 건물에 시설된 접지방식의 현장 실태 분석)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2208-2209
    • /
    • 2008
  • 최근 국제 표준 및 규격의 국내 도입에 따라 다양한 접지 방식에 대한 안전성과 신뢰성이 요구되고 있으나, 현재 국내 규정은 국제 규격과 부합되지 않는 측면이 있다. 따라서, 국내 건축물의 접지시스템에 대한 정확한 현장 실태를 바탕으로 국내 실정에 맞는 접지시스템의 개발이 요구되고 있다. 본 논문에서는 아파트, 공장, 상가, 학교 등의 신축 건물에 시설된 접지방식 및 등전위 본딩 실태 등을 현장 조사를 중심으로 분석하였다. 접지실태조사는 접지방식, 접지단자의 접속방식, 공결방식, 접지요소간의 접속방식 등을 분석하였으며, 등전위 본딩 실태조사는 IEC 60364에 규정된 방법을 근거로 계통외 도전성 부분과 기기외함의 연속성을 평가하였다.

  • PDF