• 제목/요약/키워드: ICP0

검색결과 872건 처리시간 0.036초

Characterizations of i-a-Si:H and p-a-SiC:H Film using ICP-CVD Method to the Fabrication of Large-area Heterojunction Silicon Solar Cells

  • Jeong, Chae-Hwan;Jeon, Min-Sung;Kamisako, Koichi
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권2호
    • /
    • pp.73-78
    • /
    • 2008
  • We investigated for comparison of large-area i-a-Si:H and p-a-SiC:H film quality like thickness uniformity, optical bandgap and surface roughness using both ICP-CVD and PECVD on the large-area substrate(diameter of 100 mm). As a whole, films using ICP-CVD could be achieved much uniform thickness and bandgap of that using PECVD. For i-a-Si:H films, its uniformity of thickness and optical bandgap were 2.8 % and 0.38 %, respectively. Also, thickness and optical bandgap of p-a-SiC:H films using ICP-CVD could be obtained at 1.8 % and 0.3 %, respectively. In case of surface roughness, average surface roughness (below 5 nm) of ICP-CVD film could be much better than that (below 30 nm) of PECVD film. HIT solar cell with 2 wt%-AZO/p-a-SiC:H/i-a-Si:H/c-Si/Ag structure was fabricated and characterized with diameter of 152.3 mm in this large-area ICP-CVD system. Conversion efficiency of 9.123 % was achieved with a practical area of $100\;mm\;{\times}\;100\;mm$, which can show the potential to fabrication of the large-area solar cell using ICP-CVD method.

ICP-MS에 의한 지하수 중의 Germanium 분석에 관한 연구 (Determination of Germanium in Spring Waters by Inductively Coupled Plasma Mass Spectrometry)

  • 박경수;송승연;심의섭;김선태
    • 분석과학
    • /
    • 제11권2호
    • /
    • pp.120-124
    • /
    • 1998
  • 지하수 중의 극미량 germanium을 ICP-MS로 신속, 정확하게 분석할 수 있었으며 질량수 74를 분석하는 것이 가장 방해영향이 적음을 알 수 있었다. 지하수 중의 약 30%만이 $0.1{\mu}g/L$ 이상의 germanium을 함유하였고, 유기 germanium을 포함하는 지하수의 존재도 확인하였다.

  • PDF

ICP-AES를 이용한 전처리방법에 따른 환경시료내 Pb, Cd의 측정 비교 연구 (A comparative measurement study of Pb, Cd using ICP-AES with different pretreatment methods)

  • 권태영;윤춘경;전지홍
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.513-520
    • /
    • 1998
  • The evaluation of uncertainty in environmental elemental analysis can be difficult because of the wide variety of analytical sample and objectives. for the specification of measured, elemetal analysis need certain method and high pretreatment technique. The sample of Pb, Cd in paddy soil and sewage sludge were analyzed by same ICP-AES, but each using four different pretreatment technique ; 0.1N HCl extraction, AB-DTPA extraction and two Mixture Acid Digestion. The four technique gave comparable results for the analysis of lead and cadmium. Concentrations determined by Mixture Acid Digestion were more higher than those by 0.1NHCI extraction and AB-DTPA extraction.

  • PDF

뇌동맥류 수술환자에게 적용한 두부체위가 두개강내압에 미치는 영향 (Effect of Head Elevation and Position on Intracranial Pressure(ICP) in the Neurosurgical Patient with a Cerebral Aneurysm)

  • 박혜자;최경옥;이병옥;정은주;유양숙
    • 대한간호학회지
    • /
    • 제27권3호
    • /
    • pp.503-509
    • /
    • 1997
  • This study was undertaken to identify optimal head elevation and position in the care of the neurosurgical patient with a cerebral aneurysm. The effects of 0°. 15° and 30° head elevation and three positions (supine, side tying position opposite to the operation site, and side tying position on the same side as the operation site) on ICP was studied in fourteen neurosurgical patients with cerebral aneurysms. The results are as follows : 1. The mean intracranial pressure was significantly lower when the patient's head was elevated at 30° as compared to 0° and 15°. 2. The mean intracranial pressure was significantly lower when the patient was positioned in the supine as compared to side tying position opposite to the operation site and side tying position on the same side as the operation site. The data indicate that head elevation to 30° and the supine position reduce ICP in neurosurgical patients with cerebral aneurysm.

  • PDF

반응표면분석법을 활용한 저상품성 향어(Cyprinus carpio) 쿠키 제조 공정 최적화 (Process Optimization for Cookies with Low-marketable Israeli Carp Cyprinus carpio Using Response Surface Methodology (RSM))

  • 김예율;강상인;김진수
    • 한국수산과학회지
    • /
    • 제56권3호
    • /
    • pp.284-292
    • /
    • 2023
  • This study was conducted to optimize the cookie preparation using Israeli crap Cyprinus carpio paste (C-ICP). The results of response surface methodology suggested the selection of other supplementary materials/[soft flour (SF) + ICP] (X1) and SF/ICP (X2) as independent variables, and hardness (Y1), yellowness (Y2), amino acid nitrogen (Y3), and overall sensory acceptance (Y4) as dependent variables. The optimal conditions of OS, SF, and ICP were 35.0%, 40.3% and 24.7%, respectively, and the predicted values of the multiple response optimal conditions Y1, Y2, Y3, and Y4 were 2,006.2 N/m2, 21.1, 30.0 mg/100 g, and a score of 6.6, respectively. Under the optimum conditions, experimental values of Y1, Y2, Y3, and Y4 were 2,010.5 ± 22.3 N/m2, 21.6 ± 0.5, 29.6 ± 0.7 mg/100 g, and a score of 6.9 ± 0.3, respectively, which were not significantly different from the predicted values (P < 0.05). The results on hardness, moisture, VCI yellowness, and lightness suggested that the optimum heating period was 20 min. C-ICP prepared under the optimum conditions was superior in sensory evaluation to cookies without the Israeli carp paste.

유도결합 플라즈마 파워가 NbN 코팅막의 미세구조, 결정구조 및 기계적 특성에 미치는 영향에 관한 연구 (Effect of Inductively Coupled Plasma on the Microstructure, Structure and Mechanical Properties of NbN Coatings)

  • 전성용
    • 한국표면공학회지
    • /
    • 제48권5호
    • /
    • pp.205-210
    • /
    • 2015
  • NbN coatings were prepared by ICP (inductively coupled plasma) assisted magnetron sputtering from a Nb metal target in $Ar+N_2$ atmosphere at various ICP powers. Effect of ICP on the microstructure, crystalline structure and mechanical properties of NbN coatings was investigated by field emission electron microscopy, X-ray diffraction, atomic force microscopy and nanoindentation measurements. The results show that ICP power has a significant influence on coating microstructure, structure and mechanical properties of NbN coatings. With the increasing of ICP power, coating microstructure evolves from the columnar structure of DC process to a highly dense one. Crystalline structure of NbN coatings were changed from cubic ${\delta}$-NbN to hexagonal ${\beta}-Nb_2N$ with increase of ICP power. The maximum nano hardness of 25.4 GPa with Ra roughness of 0.5 nm was obtained from the NbN coating sputtered at ICP power of 200 W.

High sensitivity determination of iridium contents in ultra-basic rocks by INAA with coincidence gamma-ray detection

  • Ebihara, Mitsuru;Shirai, Naoki;Kuwayama, Jin;Toh, Yosuke
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.423-428
    • /
    • 2022
  • Very low contents (in the range of 10-9 g/g) of Ir in mantle-derived rock samples (komatiites) were non-destructively determined by INAA coupled with coincidence gamma-ray spectrometry using 16 Ge detectors. Aliquots of the same samples were analyzed by NiS fire-assay ICP-MS for Ir and other platinum group elements. Because the INAA procedure used in this study is non-destructive and is almost free from spectral interference in gamma-ray spectrometry, the INAA values of Ir contents obtained in this study can be highly reliable. Iridium values obtained by ICP-MS were consistent with the INAA values, implying that the ICP-MS values of Ir obtained in this study are equally reliable. Under the present experimental conditions, detection limits were estimated to be 1 pg/g, which corresponds to 0.1 pg for a sample mass of 0.1 g. These levels can be even lowered by an order of magnitude, if necessary, which cannot be achieved by ICP-MS carried out in this study.

Changes in Blood Pressure and Heart Rate during Decompressive Craniectomy

  • Jo, Kwang Wook;Jung, Hyun-Ju;Yoo, Do Sung;Park, Hae-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.957-965
    • /
    • 2021
  • Objective : Rapid increase in intracranial pressure (ICP) can result in hypertension, bradycardia and apnea, referred to as the Cushing phenomenon. During decompressive craniectomy (DC), rapid ICP decreases can cause changes in mean atrial blood pressure (mABP) and heart rate (HR), which may be an indicator of intact autoregulation and vasomotor reflex. Methods : A total of 82 patients who underwent DC due to traumatic brain injury (42 cases), hypertensive intracerebral hematoma (19 cases), or major infarction (21 cases) were included in this prospective study. Simultaneous ICP, mABP, and HR changes were monitored in one minute intervals during, prior to and 5-10 minutes following the DC. Results : After DC, the ICP decreased from 38.1±16.3 mmHg to 9.5±14.2 mmHg (p<0.001) and the mABP decreased from 86.4±14.5 mmHg to 72.5±11.4 mmHg (p<0.001). Conversly, overall HR was no significantly changed in HR, which was 100.1±19.7 rate/min prior to DC and 99.7±18.2 rate/min (p=0.848) after DC. Notably when the HR increased after DC, it correlated with a favorable outcome (p<0.001), however mortality was increased (p=0.032) when the HR decreased or remained unchanged. Conclusion : In this study, ICP was decreased in all patients after DC. Changes in HR were an indicator of preserved autoregulation and vasomotor reflex. The clinical outcome was improved in patients with increased HR after DC.

플라즈마 식각을 이용한 초전도 자속 흐름 트랜지스터 제작 (Fabrication of Superconducting Flux Flow Transistor using Plasma etching)

  • 강형곤;임성훈;고석철;한윤봉;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.74-77
    • /
    • 2002
  • The channel of the superconducting Flux Flow Transistor has been fabricated with plasma etching method using ICP. The ICP conditions were 700 W of ICP power, 150 W of rf chuck power, 5 mTorr of the pressure in chamber and 1:1 of Ar : Cl$_2$, respectively. The channel etched by plasma gas showed superconducting characteristics of over 77 K and superior surface morphology. The critical current of SFFT was altered by varying the external applied current. As the external applied current increased from 0 to 12 mA, the critical current decreased from 28 to 22 mA. Then the obtained r$\sub$m/ values were smaller than 0.1Ω at a bias current of 40 mA. The current gain was about 0.5. Output resistance was below 0.2 Ω.

  • PDF

이플루오린화 암모늄 시료분해 및 ICP/MS에 의한 암석 및 퇴적물 중 게르마늄 분석 (Analysis of germanium in rock and sediment by ICP/MS after ammonium bifluoride(NH4HF2) digestion)

  • 음철헌;최원명
    • 분석과학
    • /
    • 제26권6호
    • /
    • pp.375-380
    • /
    • 2013
  • 본 연구에서는 암석과 퇴적물 시료를 대상으로 이플루오린화 암모늄을 이용한 시료 분해법을 적용하여 open vessel digestion 후 유도결합 플라즈마 질량분석법(Inductively coupled plasma mass spectrometry, ICP/MS)으로 게르마늄을 분석하였다. 미국 지질조사소 표준물질 중 QLO-1, SDO-1을 사용하였고, 실제 시료로 GeoPT용 퇴적물, 현무암, 점토를 사용하였다. 휘발하여 손실되기 쉬운 것으로 알려진 게르마늄을 이플루오린화 암모늄($NH_4HF_2$) 시료 분해법을 사용함으로서 게르마늄 휘발 억제와 동시에 암석 및 퇴적물을 open vessel digestion하에서 간단하고 빠르게 분해 가능하였으며, 또한 이플루오린화 암모늄 분해법에 과산화수소를 함께 사용해도 게르마늄의 회수율에 영향을 끼치지 않았다. ICP/MS에 의한 게르마늄 분석 결과, MDL (method detection limit)은 0.015 ${\mu}g/g$, 게르마늄 회수율은 106~128% 이었다.