• Title/Summary/Keyword: ICP0

Search Result 877, Processing Time 0.028 seconds

Evaluation of Accuracy and Precision of Analysis of Metals with Polyvinyl Chloride Membrane Filters (PVC 여과지를 이용한 금속 분석방법에 대한 정확도와 정밀도 평가)

  • Byun, Seong-Uk;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.48-57
    • /
    • 2016
  • Objectives: This study was conducted to evaluate the accuracy and precision of airborne metal analysis using polyvinyl chloride(PVC) membrane filter by pretreatment methods. Methods: A total of 75 spiked PVC samples for Cr, Fe and Mn ranged from 6 ug/sample to 40 ug/sample were used to evaluate recovery rates for three pretreatment methods: acid extraction, hot plate ashing and microwave digestion. For Mn, an additional 75 spiked mixed cellulose ester(MCE) membrane filters were analysed to compare the recovery rates of PVC samples. All samples were analysed with an inductively coupled plasma optical emission spectrometer(ICP-OES) and manganese samples were additionally analyzed by atomic absorption spectrometer(AAS). Results: The overall mean recovery rates of PVC samples for Cr, Fe and Mn were 90% or higher regardless of pretreatment methods, but there were statistically significant differences in recovery rates for Cr(p<0.05) and Mn(p<0.01) samples by pretreatment methods. The biases and the coefficient variations of PVC samples for three metals pretreated with three kinds of pretreatment methods ranged from 1.7% to 4.7% and from 1.6% to 6.5%, respectively. The manganese PVC samples pretreated by microwave digestion and analyzed with ICP-OES had the lowest bias at 1.9% and also showed lower bias than the bias for MCE samples, 2.7%. Conclusions: In order to accurately analyze the metals sampled with PVC membrane filters, microwave digestion and ICP-OES can be recommended.

A Study on plasma etching for PCR manufacturing (PCR 장치를 위한 플라즈마 식각에 관한 연구)

  • Kim, Jinhyun;Ryoo, Kunkul;Lee, Jongkwon;Lee, Yoonbae;Lee, Miyoung
    • Clean Technology
    • /
    • v.9 no.3
    • /
    • pp.101-105
    • /
    • 2003
  • Plasma etching technology has been developed since it is recognized that silicon etching is very crucial in MEMS(Micro Electro Mechanical System) technology. In this study ICP(Inductive Coupled Plasma) technology was used as a new plasma etching to increase ion density without increasing ion energy, and to maintain the etching directions. This plasma etching can be used for many MEMS applications, but it has been used for PCR(Polymerase Chain Reaction) device fabrication. Platen power, Coil power and process pressure were parameters for observing the etching rate changes. Conclusively Platen power 12W, Coil power 500W, etchng/passivation cycle 6/7sec gives the etching rate of $1.2{\mu}m/min$ and sidewall profile of $90{\pm}0.7^{\circ}$, exclusively. It was concluded from this study that it was possible to minimize the environmental effect by optimizing the etching process using SF6 gas.

  • PDF

Separation of Goid, Palladium and Platinum in Chromite by Anion Exchange Chromatography for Inductively Coupled Plasma Atomic Emission Spectrometric Analysis

  • Choe, Gwang Sun;Lee, Chang Hyeon;Park, Yeong Jae;Jo, Gi Su;Kim, Won Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.801-806
    • /
    • 2001
  • A study has been carried out on the separation of gold, iridium, palladium, rhodium, ruthenium and platinum in chromite samples and their quantitative determination using inductively coupled plasma atomic emission spectrometry (ICP-AES). The dissolution condition of the minerals by fusion with sodium peroxide was optimized and chromatographic elution behaviour of the rare metals was investigated by anion exchange chromatography. Spectral interference of chromium, a matrix of the minerals, was investigated on determination of gold. Chromium interfered on determination of gold at the concentration of 500 mg/L and higher. Gold plus trace amounts of iridium, palladium, rhodium and ruthenium, which must be preconcentrated before ICP-AES was separated by anion exchange chromatography after reducing Cr(Ⅵ) to Cr(III) by H2O2. AuCl4- retained on the resin column was selectively eluted with acetone- HNO3-H2O as an eluent. In addition, iridium, palladium, rhodium and ruthenium remaining on the resin column were eluted as a group with concentrated HCl. However, platinum was eluted with concentrated HNO3. The recovery yield of gold with acetone-HNO3-H2O was 100.7 ${\pm}2.0%$, and the yields of palladium and platinum with concentrated HCl and HNO3 were 96.1 ${\pm}1.8%$ and 96.6 ${\pm}1.3%$, respectively. The contents of gold and platinum in a Mongolian chromite sample were 32.6 ${\pm}$ 2.2 ${\mu}g$/g and 1.6 $\pm$ 0.14 ${\mu}g$/g, respectively. Palladium was not detected.

Monitoring of some heavy metals in oriental animality medicines (동물성 생약에 함유되어 있는 몇 가지 중금속에 대한 실태 조사)

  • Baek, Sunyoung;Chung, Jaeyoen;Lee, Jihye;Park, Kyungsu;Kang, Inho;Kang, Sinjung;Kim, Yunje
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.201-209
    • /
    • 2009
  • Four heavy metals (Pb, Cd, As, and Hg) in 38 species (total 325 samples) of oriental animality medicines were monitored by inductively coupled plasma-mass spectrometry (ICP-MS) and automatic mercury analyzer (AMA). The detected concentration range of Pb, Cd, As was presented as $0.02{\mu}gkg^{-1}$ $(D.L){\sim}11.29mgkg^{-1}$, $0.01{\mu}gkg^{-1}$ $(D.L){\sim}2.50 mgkg^{-1}$, $0.12{\mu}gkg^{-1}$ $(D.L){\sim}5.27mgkg^{-1}$, respectively. In case of Hg, it the concentration range was $0.01{\sim}77.11mgkg^{-1}$ except one sample which exceeded detection limit. In all samples of Amydae Carapax and Gallnut, it was not detected over the maximum residue limits of metals. Pb is in charge of the greatest portion of contamination in 22 species of animality medicines, and in case of Hg, 54.46% of total samples were over the maximum residue limits. Therefore, environmental levels of Pb and Hg are needed to continue the researches and the studies for tracking pollution source are required.

A Study on Determination of Iodine in Serum, Fresh Milk, and Feed Additive by Inductively Coupled Plasma-Mass Spectrometry (유도결합 플라스마-질량분석법에 의한 혈청, 생우유 및 사료첨가제중 요오드의 분석에 관한 연구)

  • Lee, Won;Park, Kyung-Su;Kim, Sun-Tae;Kim, Young-Man
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.528-533
    • /
    • 1999
  • The total iodine is determined in serum, fresh milk and feed additive by ICP-MS. The preparation involves only a 25-fold dilution with a diluent by direct nebulization in the plasma. The diluent composition is $NH_4OH$(0.5% v/v)+$CH_3OH$(5% v/v) and the abundance of iodine is measured at m/z=127. The calibration curve was linear over the ranges $0-100{\mu}g/L$ with $R^2=0.99$ for iodine. The detection limit of this method is $0.084{\mu}g/L$ for iodine. The relative error range of milk powder SRM in optimum condition is 2.30%-4.73%. The concentration ranges of iodine in the serum, fresh milk, feed additive were $12.4-40.2{\mu}g/L$, < 0.01-3.11 mg/L, < $10^{-7}-2.60g/kg$ respectively.

  • PDF

Outcomes and physiologic responses associated with ketamine administration after traumatic brain injury in the United States and Canada: a retrospective analysis

  • Austin J. Peters;Saad A. Khan;Seiji Koike;Susan Rowell;Martin Schreiber
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.354-361
    • /
    • 2023
  • Purpose: Ketamine has historically been contraindicated in traumatic brain injury (TBI) due to concern for raising intracranial pressure. However, it is increasingly being used in TBI due to the favorable respiratory and hemodynamic properties. To date, no studies have evaluated whether ketamine administered in subjects with TBI is associated with patient survival or disability. Methods: We performed a retrospective analysis of data from the multicenter Prehospital Tranexamic Acid Use for Traumatic Brain Injury trial, comparing ketamine-exposed and ketamine-unexposed TBI subjects to determine whether an association exists between ketamine administration and mortality, as well as secondary outcome measures. Results: We analyzed 841 eligible subjects from the original study, of which 131 (15.5%) received ketamine. Ketamine-exposed subjects were younger (37.3±16.9 years vs. 42.0±18.6 years, P=0.037), had a worse initial Glasgow Coma Scale score (7±3 vs. 8±4, P=0.003), and were more likely to be intubated than ketamine-unexposed subjects (88.5% vs. 44.2%, P<0.001). Overall, there was no difference in mortality (12.2% vs. 15.5%, P=0.391) or disability measures between groups. Ketamine-exposed subjects had significantly fewer instances of elevated intracranial pressure (ICP) compared to ketamine-unexposed subjects (56.3% vs. 82.3%, P=0.048). In the very rare outcomes of cardiac events and seizure activity, seizure activity was statistically more likely in ketamine-exposed subjects (3.1% vs. 1.0%, P=0.010). In the intracranial hemorrhage subgroup, cardiac events were more likely in ketamine-exposed subjects (2.3% vs. 0.2%, P=0.025). Ketamine exposure was associated with a smaller increase in TBI protein biomarker concentrations. Conclusions: Ketamine administration was not associated with worse survival or disability despite being administered to more severely injured subjects. Ketamine exposure was associated with reduced elevations of ICP, more instances of seizure activity, and lower concentrations of TBI protein biomarkers.

Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements (형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석)

  • 이용근;박현미;이동수;이보경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

Determination of Heavy Metal Contents in Oriental Medical Materials and the Effect of Washing (한약재내 중금속 함량분석 및 물세척 효과)

  • 이승훈;최호영;박창호
    • KSBB Journal
    • /
    • v.18 no.2
    • /
    • pp.90-93
    • /
    • 2003
  • Six heavy metals (lead, copper, cadmium, chromium, mercury and arsenic) were analyzed in 9 oriental medical materials(Paeoniae Radix Alba, Zizyphi Fructus, Cnidii Rhizoma, Rehmanniae Radix Preparata, Angelicae Gigantis Radix, Astragali Radix, Glycyrrhizae Radix, Cinnamomi Cortex Spissus, and Zingiberis Rhizoma Crudus) by inductively coupled plasma atomic emission spectrometry (ICP-AES). The heavy metal contents of Zingberis Rhizoma Crudus and Angelicae Gigantis Radix were 44.0 and 37.3 mg/kg, respectively, which were 1.47 and 1.24 times higher than the guideline set by the Korean Food and Drug Administration (KFDA). Washing with deionized water lowered the heavy metal contents by 20-38%, and reduced levels to below the guidelines set by KFDA.

Ar 중성빔과 $BCl_3$를 이용한 $ZrO_2$의 원자층 식각에 관한 연구

  • Kim, Lee-Yeon;Im, Ung-Seon;Park, Byeong-Jae;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.107-107
    • /
    • 2009
  • 본 연구에서는 중성빔을 이용한 Atomic Layer Etching(ALET) system을 이용하여 $ZrO_2$의 atomic layer etching mechanism에 대하여 연구하였다. Ar neutral beam irradiation dose와 $BCl_3$ gas pressure의 변화에 따라 $ZrO_2$ etch rate와 RMS roughness를 관찰했을 때, Ar neutral beam irradiation dose이 $1.485{\times}10^{16}atoms/cm^2{\bullet}cycle$ 이상이고 $BCl_3$ gas pressure가 0.15mTorr 이상 일 때 $ZrO_2$ etch rate은 $1.07\;{\AA}/cycle$의 일정한 값에서 유지됨을 확인하였다. 그리고 ALET와 ICP Etcher을 통해 $ZnO_2$를 각각 식각하여 physically or chemically damage를 비교한 결과, ALET가 기존의 ICP Etcher system보다 $ZrO_2$ 식각공정에 대해 적은 damage를 받는 것을 ARXPS를 통해 관찰 하였다.

  • PDF

Numerical Modeling of Perturbation Effects of Electrostatic Probe into 2D ICP(inductively coupled plasma) (2D-ICP(inductively coupled plasma)에서 정전 탐침 삽입 시의 플라즈마 수치 계산)

  • Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.1
    • /
    • pp.26-31
    • /
    • 2011
  • Numerical modeling is used to investigate the perturbation of a single Langmuir probe (0.2 mm diameter shielded with 6 mm insulator) inserted along the center axis of a cylindrical inductively coupled plasma chamber filled with Ar at 10 mTorr and driven by 13 MHz. The probe was driven by a sine wave. When the probe tip is close to a substrate by 24.5 mm, the probe characteristics was unperturbed. At 10 mm above the substrate, the time averaged electric potential distribution around the tip was severly distorted making a normal probe analysis impossible.