The Transactions of The Korean Institute of Electrical Engineers
/
v.56
no.7
/
pp.1261-1267
/
2007
Although LEDs have been used in various applications with improving the brightness and luminous efficacy, the electrical and optical characteristics of high power LED varies at different temperature and starting time. In this paper, optimal heat sink and apparatus design were conducted using IR camera and ICEPAK on the LED bulb consisting with fourteen LED array. The temperatures of heat sink and LED device of the designed LED bulb without cooling pan were $74^{\circ}C\;and\;96.8^{\circ}C$, respectively, showing in good themal characteristics. For high efficiency driving circuit of LED array adopted optimal heat sink design, driving circuits of constant voltage and current circuits were suggested and fabricated. As a result the efficacy of all driving circuits showed more than 20 lm/W. Also, the constant current circuits are suitable for signal lamp, hallway lamp, and flash lamp having short operating time(about 30 min). On the other hand, a reading light and indoor lamp having long operating time can be controlled by constant voltage circuit.
A Molded Case Circuit Breaker (MCCB) is an electric control device to interrupt the abnormal currents which result from the over-loads or short-circuits. Its malfunction will result in severe accidents. In the development of the MCCB, higher current-rating and improved thermal performance become more and more important in providing the safe function and reliability for the modern devices requiring small scale and high performance. It is also very important to consider the factors of temperature rise in the design of MCCB. The major reasons of temperature rise in the MCCB result from the resistances, which are come from the connection and contact surfaces. These resistances are influenced by current, time, configuration of contact surfaces and applied voltage. In order to predict the temperature distribution inside MCCB, we have simulated the model with some assumptions and simplifications, using commercial code ICEPAK. To verify the results of temperature field analysis, the numerical results are compared with experimental ones for the same model. The results show a good agreement with actual temperature rise obtained by experiments.
Journal of the Korean Society for Aeronautical & Space Sciences
/
v.40
no.1
/
pp.61-68
/
2012
The purpose of Crash Protected Module in Black Box used at aircraft is to protect a stored information(Flight data & Cockpit Voice) safely even after extreme environment like a plane crash. This study shows the structure & thermal analyses and the comparisons of predictions and results of tests about CPM for Crash Survival through extreme environment such as Penetration Resistance, High Temperature Fire, Low Temperature Fire. Specially, the Effect of housing thickness change was studied through the Penetration Resistance analysis using LS-DYNA, and the influence of volume ratio change between phase change material and thermal insulation material was studied through the High Temperature & Low Temperature analysis using Icepak. Also, structural and thermal reliability of CPM was validated through the tests.
Transactions of the Korean Society of Mechanical Engineers B
/
v.36
no.8
/
pp.821-828
/
2012
Increasing heat generation in CPUs can hamper effective recirculation and by-pass because of the large temperature difference between the exhaust and the intake air through a server room. This increases the overall temperature inside a data center and decreases the efficiency of the data center's cooling system. The purpose of the data center's cooling system is to separate the intake and exhaust air by controlling the computer room air-conditioner(CRAC). In this study, ICEPAK is used to conduct a numerical analysis of a data center's cooling system. The temperature distribution and the entire room are analyzed for different volumetric flow rates. The optimized volumetric flow rate is found for each CPU power. The heat removal and temperature distribution for CPU powers of 100, 120, and 140 W are found to be the best for a volumetric flow rate of $0.15m^3/s$. The numerical analysis is verified through RTI indicators, and the results appear to be the most reliable when the RTI value is 81.
Kim, Yun-Sung;Seo, Ki-Bong;Lee, Yong-Hwa;Baeg, Byung-Dug
Proceedings of the KIEE Conference
/
2009.07a
/
pp.927_929
/
2009
This paper reports the case that unitizes heat analysis simulation in housing design of DC-DC converter. Icepak4.3 is used for heat analysis simulation program. 1.5kW prototype is produced with base of finally selected structure through simulation and is compared heating characteristic. Propriety of development application is confirmed through the result, shortening case of development cost and period is introduced.
In this paper we have studied the characteristics of temperature fields in a Molded Case Circuit Breaker (MCCB). A switch and a trip device are arranged in narrow space of the MCCB. Thus, thermal factors have been risen to important problem. The temperature rise means an energy loss and it becomes the reason of fatal fault in devices. Also, the temperature rise on the connection and the contact parts is regulated up to $115^{\circ}C$ and $105^{\circ}C$, respectively. Therefore, a study for preventing the temperature rise should be investigated. A numerical analysis method that has confidence might be preceded for this purpose. In order to verify the confidence of temperature field analysis, the results of the numerical analysis are compared with those of experimental one for the same model. Comparison results show a qualitatively good agreement within ${\pm}5%$ errors.
최근 전기/전자 제품 개발에서 대용량, 소형화가 이루어지면서 제품 설계에 열유동 및 구조적 문제가 중요한 요소로 등장하였다. 열유동은 발열체와 공기의 흐름에 관련이 있기 때문에 시스템의 구조를 어떻게 설계 하느냐가 방열의 중요한 요소이다. 본 논문에서는 Ansys사(社)의 소프트웨어를 이용하여 연료전지용 PCS에 대한 열유동, 구조 및 강도 해석을 수행하였다. 3D설계는 CAD(Computer Aided Design) 소프트웨어인 Pro Engineer를 이용하였다. 설계된 3D 도면을 Ansys Multiphysics로 불러들여 구조 및 강도해석을 하였고 CFD(Computational Fluid Dynamics) 소프트웨어인 Icepak으로 열유동해석을 수행하였다.
In this study, the computational heat transfer of the high-voltage vacuum circuit breaker was investigated. Higher normal current-ratings and stabilized thermal characteristics become more important in existing circuit breakers in order to satisfy market needs. Increases in current-ratings have an even greater effect on the Joule heating in the main circuit of the breakers. The thermal design must account for this increase in heat produced for the breaker to meet various temperature-rise limits set by industry standards. We are studying to enhance the normal current-ratings without major frame change of our present production models. As the method used in this research, we performed the computational analysis using the commercial Package, ICEPAK. We could get optimized thermal design suitable for 25% upgraded normal current-ratings through parametric study.
재택근무와 소규모 창업 등 사무 환경의 변화 에 따라 프린터와 복합기의 소형화가 요구 되고 있다. 이러한 소형화에 의해 프린터 내부의 발열 요소들이 제한 된 공간에 배치되어, 기기 내부의 열 유동 및 발열 개선은 제품의 수명과 안정성 확보를 위한 중요 사항이 되었다. 본 논문에서는 프린터와 복합기의 내부 요소 중 주요 발열원인 전원 공급 장치에 대하여 Computational fluid dynamics (CFD) software 인 ICEPAK을 이용하여 중요 부품의 배치 조건에 따른 대류 와 온도 특성을 확인 하고, 최적화 된 부품 배치 방법을 제안한다. 또한 제안하는 부품 배치 방법을 적용한 초박형 프린터용 50W 급 전원 공급 장치를 제작하여 실제 온도 특성이 개선됨을 확인한다.
고출력 LED의 전기적 광학적 열적인 특성을 분석한 결과를 토대로 MCPCB를 사용하지 않고 전구 형태의 좁은 면적에 고출력 1W LED를 배열하고, 적외선 카메라와 ICEPAK(열유동해석 프로그램)을 이용하여 14개의 LED 배열에 대한 LED 전구의 최적방열 및 기구 설계를 실시하였다. LED 전구에 대한 정전압과 정전류 제어방식의 고효율 구동회로를 제작하여, 약 70% 이상의 회로 효율과 약 95% 이상의 고역률, 약 20lm/W 이상의 고효율 LED 전구를 실현하였다. 정전압 구동회로는 동작시간에 무관하게 일정한 광출력을 나타내며, 정전류 구동회로는 초기 시동시 높은 광출력을 나타내고 동작시간의 경과에 따라 광출력 감소율이 높게 나타냄을 알 수 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.