• Title/Summary/Keyword: IC device

Search Result 242, Processing Time 0.023 seconds

Analysis of Security Threats from Increased Usage of Mobile App Services (모바일 앱 서비스 이용 증가로 인한 보안 위협 분석)

  • Choi, Heesik;Cho, Yanghyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.1
    • /
    • pp.45-55
    • /
    • 2018
  • Recently, because the arrival of the fourth industrial revolution era, many information and telecommunication services have grown rapidly in the mobile business market. So, companies are based Mobile Apps on user customized services and expanding their services. From the standpoint of the business, to generate revenue, the company needs to maintain the existing current computer environment and develop Mobile Apps to offer convenience in various areas such as finance, admiration, e-commerce and sales support. However, as the number of users increase due to expansion of various Mobile services, security threats that are related to Mobile Apps are increasing and its damage is also increasing. Due to the rapid technological transformation of Mobile devices using the Internet, the level of security threats to Smartphones are rising and getting more advance, so this thesis is structured as follows. In Chapter 2, it will look at the overall trends of Mobile Apps as related research. In Chapter 3, it will discuss various security concerns that related to the latest Mobile Apps and learn about the threatening factors. In Chapter 4, it will compare and analyze the threatening factors. Then it will find and suggest the possible plan. In Chapter 5, it will end with conclusion. Finally, to protect mobile devices from security threats, the environment of operating system which manages the resources and data of Apps needs to be protected. Also, it is important that users to have awareness and check activation FinTech technology security in the process of simple payment with fingerprint or IC card.

High Efficiency Magnetic Resonance Wireless Power Transfer System and Battery Charging Chip (자기 공진 방식의 고효율 무선 전력 전송 시스템 및 배터리 충전 칩)

  • Youn, Jin Hwan;Park, Seong Yeol;Choi, Jun Rim
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.6
    • /
    • pp.43-49
    • /
    • 2015
  • In this paper, we propose enhanced wireless power transfer system based on magnetic resonance for portable electronic device charging. Resonators were designed and fabricated for efficiency improvement and miniaturization through electromagnetism simulation using HFSS(High Frequency Structure Simulator). Impedance matching network is employed to minimize reflections that is caused by difference between input impedance and output impedance. Receiver IC that consist of rectifier and Low Drop Out(LDO) regulator were designed and fabricated to reduce power loss. This chip is implemented in $0.35{\mu}m$ BCD technology. A maximum overall efficiency of 73.8% is determined for the system through experimental verification.

Feasibility Study for the Development of a Device for Pathological Tissue (병리학적 조직 진단장치 개발에 대한 타당성 분석 연구)

  • Ko Chea-Ok;Park Min-Young;Kim Jeong-Lan;Lee Ae-Kyoung;Choi Hyung-Do;Choi Jae-Ic;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.341-350
    • /
    • 2006
  • In this paper, a new method for detecting breast cancer is proposed, which utilizes dielectric characteristics of pathological tissues and time delay of back scattered response, and its feasibility was investigated. We have developed a detection algorithm and verified it by numerical simulation and measurement for a prototype system. For a prototype system, we have fabricated experimental model(artificial breast with a cancer) and UWB(ultra-wideband) antenna. The results of the measurement simulation show an excellent detection capability of a cancer tissue. It is found that a good UWB antenna and a good calibration signal are key elements of such detection system. Further study is ongoing to develop a commercial system.

Synchronous Buck Converter with High Efficiency and Low Ripple Voltage for Mobile Applications (고 효율 저 리플 전압 특성을 갖는 모바일용 동기 형 벅 컨버터)

  • Yim, Chang-Jong;Kim, Jun-Sik;Park, Shi-Hong
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.319-323
    • /
    • 2011
  • In this paper presents a new model of dual-mode synchronous buck converter with dynamic control for mobile applications was proposed. The proposed circuit can operate at 2.5MHz with supply voltage 2.5V to 5V for low ripple and minimum inductor and capacitor size, which is suitable for single-cell lithium-ion battery supply mobile applications. For high efficiency, the proposed circuit adopts synchronous type and dynamic control. The proposed circuit is designed by using the device parameter of TSMC 0.18um BCD process and the performance is evaluated by Cadence spectre. Experimental board level results show the maximum conversion efficiency is 96% at 100mA load current.

Laser Damage Threshold Increase of A/R Coating Films for 200MHz AOM (A/R 코팅 변화에 따른 200MHz AOM의 laser damage threshold 증가)

  • Kim, Yong-Hun;Lee, Hang-Hun;Lee, Jin-Ho;Park, Yeong-Jun;Park, Jeong-Ho
    • Korean Journal of Materials Research
    • /
    • v.7 no.3
    • /
    • pp.213-217
    • /
    • 1997
  • AOhf(Hcousto-r)l)tic niodulator) with :!OOlIiz freclucncl- and Sfi(;(Seconrl harmonic generation) green lasel-Lvith 53% nm wavelength were used for Il\'IIII~Dii.it,ii v~ilco disk recorder) FOI rhe appli~aptin of high densit]. optical recording, a high po\ver I ~ c r is r c ~ ~ l i ~ i l - u l ic I !tic. s\-sti,m a n d optic.,~I io;iting l,t)c>rs of each optical device must have a high laser damage threshoid hie rn;itie ant] retlwtive coatings on a $TeO_{2}$ singlc crystal. which is used as an acoustooptic material, by E-beam evaporation method. Laser damage threshold \vas nicdsureci hy Ar laser with the input power oi 0.55LV 1,aser damage threiholti 01 $ZrO_{2}$ and $SiO_{2}$. filn-is were higher than $AI_{2}O_{3}$ f i l m U'e also investigated a long--tern1 stability of the output po\ver of St{(; green laser

  • PDF

The Effects of Passive Stretching of the Iliopsoas Muscles on Pulmonary Function (엉덩허리근에 대한 수동 신장이 폐 기능에 미치는 영향)

  • Han, Dong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.79-86
    • /
    • 2022
  • PURPOSE: By virtue of its location, the iliopsoas muscle has the potential to affect the function of the diaphragm. Therefore, the purpose of this study was to investigate the effects of passive stretching of the iliopsoas muscles on pulmonary function. METHODS: Twenty male university students participated in this study. Subjects with low back pain, negative results on the modified Thomas test, and chest breathing patterns not directly related to the function of the iliopsoas muscles were excluded from this study. A digital pulmonary function measuring device (Pony FX, COSMED Inc, Italy) was used to test pulmonary function. The test was performed three times: the first test before passive stretching, the second test 10 minutes after the first test, and the third after passive stretching. Passive stretching was performed 5 times for each of the left and right iliopsoas muscles. Passive stretching was carried out for 20 seconds followed by a 10-second break. The SPSSWIN (ver. 27.0) statistics program was used for data analysis, and the significance level was α =.05. RESULTS: Among slow vital capacity (SVC) parameters, tidal volume (VT), inspiratory reserve volume (IRV), inspiratory capacity (IC) and vital capacity (VC) improved significantly after passive stretching. Also, among the maximal effort vital capacity (MEVC) parameters, forced vital capacity(FVC) and forced expiratory volume in one second(FEV1) improved significantly after passive stretching. CONCLUSION: The results showed that among the various pulmonary function parameters measured, passive stretching of the iliopsoas muscles can improve the SVC and MEVC. Therefore, passive stretching of the iliopsoas muscles may be considered for use as a treatment method to improve pulmonary function.

Activation of Stripper Solution by Plasma and Hardness/Modulus of Elasticity Change of the Surface (Plasma를 이용한 세정액의 활성화와 시료 표면의 탄성계수 및 강도 변화에 대한 연구)

  • Kim, Soo-In;Kim, Hyun-Woo;Noh, Seong-Cheol;Yoon, Duk-Jin;Chang, Hong-Jun;Lee, Jong-Rim;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • In the modem semiconductor industry, the progress that consumes the most capital and labor is cleansing process. Cleansing process is to remove impurities that can affect the operation of the device and deteriorate its function. Especially, Photoresist (PR) progress that etches the device always requires cleansing at the end of the progress. Also, HDI-PR (High-Dose Ion-implanted Photoresist) created from PR progress is difficult to remove. Thus, in modem IC cleansing, many steps of cleansing are used, including dry and wet cleansing. In this paper, we suggested to combine existing dry-cleansing and wet-cleansing, each represented by plasma cleansing and stripper solution, as Plasma Liquid-Vapor Activation (PLVA). This PLVA method enhances the effect of existing cleansing solution, and decreases the amount of solution and time required to strip. We stripped HDI-PR by activated solution and measured surface hardness and Young's modulus by Nano-indenter. Nano-indenter is the equipment that determines the hardness and the modulus of elasticity by indenting nano-sized tip with specific shape into the surface and measuring weight and z-axis displacement. We measured the change of surface hardness and Young's modulus before and after the cleansing. As a result, we found out that the surface hardness of the sample sharply decreased after the cleansing by plasma-activated PR stripper solution. It can be considered that if physical surface-cleansing process is inserted after this, more effective elimination of HDI-PR is possible.

The design of the high efficiency DC-DC Converter with Dynamic Threshold MOS switch (Dynamic Threshold MOS 스위치를 사용한 고효율 DC-DC Converter 설계)

  • Ha, Ka-San;Koo, Yong-Seo;Son, Jung-Man;Kwon, Jong-Ki;Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.12 no.3
    • /
    • pp.176-183
    • /
    • 2008
  • The high efficiency power management IC(PMIC) with DTMOS(Dynamic Threshold voltage MOSFET) switching device is proposed in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. DTMOS with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuits consist of a saw-tooth generator, a band-gap reference circuit, an error amplifier and a comparator circuit as a block. The Saw-tooth generator is made to have 1.2 MHz oscillation frequency and full range of output swing from ground to supply voltage(VDD:3.3V). The comparator is designed with two stage OP amplifier. And the error amplifier has 70dB DC gain and $64^{\circ}$ phase margin. DC-DC converter, based on Voltage-mode PWM control circuits and low on-resistance switching device, achieved the high efficiency near 95% at 100mA output current. And DC-DC converter is designed with LDO in stand-by mode which fewer than 1mA for high efficiency.

  • PDF

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.

A 10b 100 MSample/s $1.4\;mm^2$ 56 mW 0.18 urn CMOS A/D Converter for Low-Power Multimedia Applications (저전력 멀티미디어 응용을 위한 10b 100 MSample/s $1.4\;mm^2$ 56 mW 0.18 um CMOS A/D 변환기)

  • Min Byoung-Han;Park Hee-Won;Chae Hee-Sung;Sa Doo-Hwan;Lee Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.53-60
    • /
    • 2005
  • This work proposes a 10b 100 MS/s $1.4\;mm^2$ CMOS ADC for low-power multimedia applications. The proposed two-step pipeline ADC minimizes chip area and power dissipation at the target resolution and sampling rate. The wide-band SHA employs a gate-bootstrapping circuit to handle both single-ended and differential inputs with 1.2 Vp-p at 10b accuracy while the second-stage flash ADC employs open-loop offset sampling techniques to achieve 6b resolution. A 3-D fully symmetrical layout reduces the capacitor and device mismatch of the first-stage MDAC. The low-noise references are integrated on chip with optional off-chip voltage references. The prototype 10b ADC implemented in a 0.18 um CMOS shows the maximum measured DNL and INL of 0.59 LSB and 0.77 LSB, respectively. The ADC demonstrates the SNDR of 54 dB, the SFDR of 62 dB, and the power dissipation of 56 mW at 100 MS/s.