• 제목/요약/키워드: IAQ

검색결과 261건 처리시간 0.032초

Box Model Approach for Indoor Air Quality (IAQ) Management in a Subway Station Environment

  • Song, Jihan;Pokhrel, Rajib;Lee, Heekwan;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권4호
    • /
    • pp.184-191
    • /
    • 2014
  • Air quality in a subway tunnel has been crucial in most of the subway environments where IAQ could be affected by many factors such as the number of passengers, the amount and types of ventilation, train operation factors and other facilities. A modeling approach has been introduced to manage the general IAQ in a subway station. Field surveys and $CO_2$ measurements were initially conducted to analyze and understand the relationship between indoor and outdoor air quality while considering internal pollution sources, such as passengers and subway trains, etc. The measurement data were then employed for the model development with other statistical information. For the model development, the algorithm of simple continuity was set up and applied to model the subway IAQ concerned, while considering the major air transport through staircases and tunnels. Monitored $CO_2$ concentration on the concourse and platform were correlated with modeling results where the correlation values for the concourse and platform were $R^2=0.96$ and $R^2=0.75$, respectively. It implies that the box modeling approach introduced in this study would be beneficial to predict and control the indoor air quality in subway environments.

건물 시공단계의 실내공기질 시뮬레이션 평가 연구 (A Study on the Simulation Evaluation of IAQ at the Process of Building Construction)

  • 최정민;조성우;박창섭;박민용;이경희
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.60-67
    • /
    • 2007
  • The purpose of this study is to evaluate indoor air quality at the stage of building construction. To check the IAQ at the stage of construction IAQX simulation program developed by EPA was used and the values of TVOC were analyzed with time-series. The Simulation conditions are as follows. 1) Ventilation rate, 2) Time schedule of works, 3) Material change. Through this simulation, the major factors which affect the IAQ were analyzed and the importance of empirical data about the time-series emission rate of concerned material could be confirmed.

유무선 네트워크기반 지하철역사 공기질 제어의 위험성 평가 (Assessment of Risk in Wireless-Wired Network Based Control of Indoor Air Quality (IAQ) in Subway Stations)

  • 최기흥
    • 한국안전학회지
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2014
  • With increasing number of citizen using subway stations everyday, safety, health and comfort of passengers and occupants became an important social issue. Considering the fact that various physical variables and pollutants are related to indoor air quality (IAQ) which may cause health problem, IAQ need to be closely monitored and controlled in multiple locations in subway stations. This study is a continuation of the previous studies and delay induced in wireless-wired network is experimentally evaluated and the risk involved is assessed. In doing that, a key parameter is identified to be the network delay in different network media. Application of information-theoretic measure to assess the risk in network delay is then discussed. The idea is based on the general principles of engineering design and their applications to quantification of uncertainty in network delay. Experimental results show that more risk is involved in wireless data communication. Efficient and fast conversion of transmission data in both LonWorks/IP server and ZL converter is also noted.

A Survey of Characterization Airborne Bio-aerosol Concentration in Public Facilities

  • Kim, Yoon-Shin;Roh, Young-Man;Hong, Seung-Cheol;Lee, Choel-Min;Jun, Hyung-Jin;Kim, Jong-Choel;Song, Min-Kyung
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.273-278
    • /
    • 2005
  • This study was performed to investigate the characteristics of distribution for airborne bio aerosol in 11 public facilities in Seoul from June to July. The collected samples are total suspended bacteria in indoor and outdoor Anderson six stage air sampler by the IAQ standard method of Ministry of Environment in Korea. The concentration of total suspended bacteria in the theater higher than IAQ standards. As the results of the survey, the most high indoor air mean concentration of bacteria $1273CFU/m^3$ was theater and the most high outdoor air mean concentration of bacteria $^229 CFU/m3$was Kindergarten. The mean concentration of bacteria in the theater was higher than the IAQ standards established by the Ministry of Environment, Republic of Korea. Moreover, this study was for investigation a part of indoor air pollution condition in public facilities. It means that this study can't represent fDr all of public facilities. Therefore, we suggest that long and middle term country plan for management of IAQ should be established through long-term and continuous investigation of IAQ condition. Also above consideration in mind, it is suggest that the research for source contribution of the results on these need further study.

  • PDF

지하철역사의 공기질 감시 및 제어를 위한 유무선 네트워크의 성능평가에 관한 연구 (Performance Evaluation of Wireless and Wired Networks for Monitoring and Control of Indoor Air Quality(IAQ) in Subway Stations)

  • 최기흥
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.1-6
    • /
    • 2012
  • 복잡한 지하철 역사에서 공기질은 승객의 안전과 건강을 좌우하는 중요한 요소이다. $CO_2$, VOCs먼지, 미생물 등의 농도는 역사의 여러 지점에서뿐만 아니라 원격지점에서도 감시 및 제어가 가능해야 하기 때문에 유무선 네트워크를 사용한 웹기반 감시 및 제어가 필요하다. 가상디바이스 네트워크(VDN) 개념에 근거한 원격 무선센서 네트워크와 디바이스 네트워크(LonWorks)를 IP 네트워크에 연동시키면 매우 강력한 분산 감시 및 제어 성능을 제공한다. 본 연구에서는 지하철역사내 공기질 감시 및 제어를 위한 유무선 네트워크의 성능평가를 실시하였다. 특히 유무선 네트워크의 데이터 전송과 지연특성을 평가하고 승객의 안전과 건강을 위한 핵심요소를 확인하였다.

공기청정용 가습액이 새집증후군 자각증상에 미치는 영향연구 (Effects of Humidification with an Air Purifying Substance on Sick Building Syndrome Symptoms)

  • 이연숙;이현정;조지연;임정은
    • KIEAE Journal
    • /
    • 제5권1호
    • /
    • pp.3-10
    • /
    • 2005
  • Indoor air quality (IAQ) is recognized as a byproduct of industrialization that took place in the 20th century. The great attention to IAQ has been gained since 1980s, and led to numerous research studies that have mainly made in the developed countries. As the development of residential environment in Korea enters in the process of qualitative growth, IAQ has viewed as one of the core issues in the society, and research in relation to IAQ has been implemented until now in the fields of engineering and medical science. It is widely known that the sources and effects of indoor air pollution have been various, and IAQ research with multidisciplinary approaches is required. Nevertheless, few research embedded into a socio-behavioral approach to identifying interventive measures of residents and analyzing their choices is made. The purpose of this study is to examine the use of an interactive measure of residents in apartments that is air purification with phytoncide available in the market, and to investigate their self-reported effects of the air purifying substance on sick building syndrome symptoms. This study utilizes a field experiment design with pre-test and post-test, and the experiment is conducted in a natural field setting. A total of 87 test subjects from 32 households with already sick building syndrome are drawn via internet, and the participation is solely voluntary. The participants receive and use the air purifying substance, and are asked to use it continuously for two weeks and identify their self-reported symptoms of before- and after-use. The research findings indicate that air purification using phytoncide is effective to alleviate their symptoms in relation to sick building syndrome. Also it is noted that the participants report that the use of the air purification causes the positive impacts on their daily life. Further research is needed that compares the group with only humidifier and evaluates the mid-term and long-term use of the air purification and its effects.

오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획 (Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations)

  • 김지영;이승희;김태연
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • 환경위생공학
    • /
    • 제18권1호
    • /
    • pp.51-57
    • /
    • 2003
  • 최근 산업장 뿐만아니라 주택에서의 실내환경오염은 대단히 중요한 관심사이다. 특히 미국 EPA에서는 성인이 하루에 약 80 % 이상을 실내 공간에서 생활하고 있는 것으로 보고하고 있으며, 이러한 생환 방식의 변화에 인한 최근 도시화 지역에서의 실내 공기질(indoor air quality)의 문제가 새로운 환경 이슈로 부각되고 있고, 일본을 비롯한 구미 각 국에서도 21세기 환경문제 중 실내환경(indoor environment) 문제를 최우선으로 다루고 있다. 그러므로 본 연구에서는 주택에서의 실내공기질을 평가하기 위하여 설문지를 통하여 인식도를 조사하고 그를 토대로 6개의 다른 주거환경을 가진 주택을 대상으로 실내공기오염도를 측정하였다. 본 연구에서 평가한 측정항목은 온도, 습도, CO, $CO_2$, 호흡성분진, 포름알데히드, 총부유세균(TBC)이었으며, 주택의 지역 및 계절별로 나누어 측정하였는데, 측정결과 호흡성분진은 주택 5,6 에서 국내의 기준을 초과하였으며, 총부유세균은 흥콩과 싱가폴의 실내기준 권고치인 $500{\;}CFU/m^3$을 초과였고, HCHO는 모든 대상 주택에서 초과하였다. 또한 통계적으로 분석한 결과 주택의 건축년도와 CO, TBC가 0.01 수준에서 유의성 관계를 나타냈으며, 습도는0.05 수준에서 유의성을 나타냈다. 또한 주택의 거주자 500인을 대상으로 조사한 설문지 결과에서는 대부분 응답자가 실내공기오염에 대하여 인식하고있으며, 실내오염으로 인해 피로>두통>눈 아픔>기침 등을 호소하고 있으며, 실내공기정화장치가 필요하다고 응답하였다. 결론적으로 본 연구의 목적은 주택에서의 실내공기질을 평가하여 실내공기질의 중요성을 인식시키고, 그에 대한 구체적인 대책방안을 제시하여 관련 기준을 준비하는데 기초적인 자료를 마련하고 주민들이 쾌적한 삶을 유지하는데 기여하고자 한다.

실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과 (The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots)

  • 박정호
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

대학교 기숙사의 실내공기환경 실태 및 개선방안 (Current Situation and Improvement of Indoor Air Quality at University Dormitory)

  • 최령희;권오정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.251-256
    • /
    • 2009
  • The purpose of this study was to suggest the idea for IAQ improvement of university dormitory through space analysis and residents' evaluation. The data was collected from 105 Konkuk university dormitory residents by a questionnaire survey. As a result, the idea for IAQ improvement of university dormitory can be suggested. First, it was found that it was necessary to improve size of windows and to exchange bathroom exhaust system for ventilation. Secondly, it is important for resident to ventilate and clean their room. Thirdly, the educational program for dormitory residents about maintenance of IAQ was esssentially needed. Also, it is necessary to manage air conditioning equipment maintenance and bathroom hygiene.

  • PDF