DOI QR코드

DOI QR Code

Assessment of Risk in Wireless-Wired Network Based Control of Indoor Air Quality (IAQ) in Subway Stations

유무선 네트워크기반 지하철역사 공기질 제어의 위험성 평가

  • Choi, Gi Heung (Department Mechanical Systems Engineering, Hansung University)
  • 최기흥 (한성대학교 기계시스템공학과)
  • Received : 2013.09.26
  • Accepted : 2014.02.14
  • Published : 2014.02.28

Abstract

With increasing number of citizen using subway stations everyday, safety, health and comfort of passengers and occupants became an important social issue. Considering the fact that various physical variables and pollutants are related to indoor air quality (IAQ) which may cause health problem, IAQ need to be closely monitored and controlled in multiple locations in subway stations. This study is a continuation of the previous studies and delay induced in wireless-wired network is experimentally evaluated and the risk involved is assessed. In doing that, a key parameter is identified to be the network delay in different network media. Application of information-theoretic measure to assess the risk in network delay is then discussed. The idea is based on the general principles of engineering design and their applications to quantification of uncertainty in network delay. Experimental results show that more risk is involved in wireless data communication. Efficient and fast conversion of transmission data in both LonWorks/IP server and ZL converter is also noted.

Keywords

References

  1. G. H. Choi, "Assessment of Indoor Air Quality(IAQ), Comfort and Safety in Metro Subway Stations", Int. J. Safety, Vol.7, No.1, pp.39-43, 2008.
  2. G. H. Choi, G. S. Choi and J. H. Jang, "Performance Evaluation of Wireless Sensor Network in Web-based Monitoring and Control of Indoor Air Quality (IAQ) in Subway Stations", Proc. of Asia Pacific Symposium on Safety, pp.119-124, 2009.
  3. G. H. Choi, "Performance Evaluation of Wireless and Wired Networks for Monitoring and Control of Indoor Air Quality (IAQ) in Subway Stations", J. of the Korean Society of Safety, Vol.27, No.1, pp.1-6, 2012 .
  4. Ben Bronsema, et al, "Performance Criteria of Buildings for Health and Comfort", Report of ISIAQ-CIB, Task Group TG42, 2004.
  5. H. W. Lee, J.-k. Park, N.-S. Jang, H.-R. Lee and H. -M. Kim, "Analysis of Ambient Air Quality Level in Subway Area in Busan Metropolitan City", J. Environmental Science, Vol. 2, pp. 207-215, 2003. https://doi.org/10.5322/JES.2003.12.2.207
  6. J.-W. Chang, J. -J. Cho, W. -G. Choi, D.-S. Park, W. -S. Jung and T. -O. Kim, "A Study of PM-10 and Heavy Metal Characteristics in the Air at the Each Site of Subway Station", J. Environmental Science, Vol.4, pp.125-129, (in Korean), 2005.
  7. Nam P. Suh, "The Principles of Design", Oxford University Press, 1990.