• Title/Summary/Keyword: I-D-F analysis

Search Result 298, Processing Time 0.025 seconds

An Analysis on the Relationship to Input/Output factor and Evaluation Grade in Nuclear R&D Program (연구개발사업의 투입.산출요소 및 연구결과 평가의 상호관계 분석 - 원자력중장기연구개발사업을 중심으로-)

  • Hong Jeong-Jin;Won Byeong-Chul;Yang Maeng-Ho
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2004.05a
    • /
    • pp.48-56
    • /
    • 2004
  • To perform R&D program, it is necessary to invest input factor(I/F). And these factor are converted to output factors(O/F) at the end of R&D program. Pee. reviewers evaluate output factors and produce evaluation grades(E/G). This paper try to analyze the relationship to I/F, O/F and E/G, According to the analysis results, the relation between I/F and E/G is as weak as the relation between O/F and E/G. The strength of relationship is relatively very strong in the relation between I/F and O/F

  • PDF

The Smoothing of Rainfall Intensity - Duration - frequency Relationships curve by the Box-Cox Transformation (Box-Cox 변환에 의한 I-D-F 곡선의 평활화)

  • Lee, Hee-Chan;Seong, Kee-Won
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.2
    • /
    • pp.153-159
    • /
    • 2003
  • When available rainfall data is not sufficient, a rough tendency of I-D-F relationship appeared frequently. In fact, rainfall intensity on the curve shows abnormally higher value the longer rainfall duration is applied that gives rise to great confusion to apply a rainfall I-D-F relationships curve to a practical work, however, the research work will present a way to solve above mentioned problem by the use of the Box-Cox transformation formula for a given rainfall data. The study came to a conclusion that the Box-Cox transformation formula is satisfied to utilize in a practical work on the ground of analysis for rainfall data of Sancheong and Yeongcheon.

A Point Rainfal1 Model and Rainfall Intensity-Duration-Frequency Analysis (점 강우모형과 강우강도-지속기간-생기빈도 해석)

  • Yu, Cheol-Sang;Kim, Nam-Won;Jeong, Gwang-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.577-586
    • /
    • 2001
  • This study proposes a theoretical methodology for deriving a rainfall intensity-duration- frequency (I-D-F) curve using a simple rectangular pulses Poisson process model. As the I-D-F curve derived by considering the model structure is dependent on the rainfall model parameters estimated using the observed first and second order statistics, it becomes less sensitive to the unusual rainfall events than that derided using the annual maxima rainfall series. This study has been applied to the rainfall data at Seoul and Inchon stations to check its applicability by comparing the two I-D-F carves from the model and the data. The results obtained are as followed. (1) As the duration becomes longer, the overlap probability increases significantly. However, its contribution to the rainfall intensity decreases a little. (2) When considering the overlap of each rainfall event, especially for large duration and return period, we could see obvious increases of rainfall intensity. This result is normal as the rainfall intensity is calculated by considering both the overlap probability and return period. Also, the overlap effect for Seoul station is fecund much higher than that for Inchon station, which is mainly due to the different overlap probabilities calculated using different rainfall model parameter sets. (3) As the rectangular pulses Poisson processes model used in this study cannot consider the clustering characteristics of rainfall, the derived I-D-F curves show less rainfall intensities than those from the annual maxima series. However, overall pattern of both I-D-F curves are found very similar, and the difference is believed to be overcome by use of a rainfall model with the clustering consideration.

  • PDF

Study on Estimation and Application of the Fwl-D-F curves for Urban Basins (도시유역의 Fwl-D-F 곡선 산정 및 활용에 관한 연구)

  • Choi, Hyun-Il;Kim, Eung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2687-2692
    • /
    • 2010
  • There have been performed many researched for flood magnitude analysis, for example, the Flood-Duration-Frequency relations in the west. Because flood water stage data are more available rather than flood amount data at flood gauge stations of Korea, this study developed Flood water level-Duration-Frequency (Fwl-D-F) curves using rainfall Intensity-Duration-Frequency(I-D-F) curves for the quantitative flood risk assessment in urban watersheds. Fwl-D-F curve is made from water level data for 18 years at Joongrayng bridge station of Joongrayng River basin in Han River drainage area. Fwl-D-F curve can estimate the occurrence frequency for a certain flood elevation, which can be used for urban flood forecasting. It is expected that the flood elevation can be estimated from the forecasted rainfall data using both Fwl-D-F and I-D-F curves.

A Study on the Difference of Rainfall Intensity According to the Omission of Short-Term (20, 30, 40, 50 Minutes) Rainfall Data in Inducing I-D-F Curves (I-D-F곡선 유도 시 짧은 지속기간(20분, 30분, 40분, 50분) 강우자료 누락에 따른 강우강도 차이 고찰)

  • Lee, Hee Chang;Seong, Kee Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.465-475
    • /
    • 2020
  • I-D-F curves were induced by Box-Cox transformation using rainfall data from five major cities in Korea: Seoul, Busan, Daegu, Daejeon, and Gwangju, as well as from Sancheong (South Gyeongsang province) and Yeongcheon (North Gyeongsang province) stations. The practicality of the Box-Cox transformation is more scalable than the traditional method of frequency analysis in terms of applicability because it is available even if the analysis data are insufficient to perform general frequency analysis and do not produce an appropriate probability density function. For the case in which rainfall data for the entire period (10-1440 minutes) and short-term period (20, 30, 40, 50 minutes) at the foregoing 7 stations are omitted, there was a relative error of -23.0 % to 14.7 % at a duration of 10 to 60 minutes below the 100-year frequency. Accordingly, rainfall analysis requires inducing I-D-F curves, including for the short term (20, 30, 40, 50 minutes), and if rainfall data are omitted for the short term (20, 30, 40, 50 minutes), it is necessary to increase the existing margin rate depending on the point in order to ensure the safe design of small-scale hydraulic structures.

Toxic Evaluation and Chromatographic Analysis of Cucurbitacin D and F from Sorbaria sorbifolia (쉬땅나무(Sorbaria sorbifolia) 성분으로서 cucurbitacin D, F의 독성평가 및 정량)

  • Lee, Sang-Myung;Lee, Cheal-Gyu
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.191-195
    • /
    • 2001
  • Cucurbitacin D and F, the protostane type triterpenoid of S. sorbifolia, were isolated with chromatograpic method and used as the standard substances for quantitative analysis. The compounds were identified with $^1H$-NMR, FAB-MS and UV spectrophotometer. They were separated on YMC-Pack ODS-AQ(303)[$250{\times}4.6mm$ I.D., $S-5{\mu}m$, 120A] column by HPLC. Cucurbitacin F was detected at 10.73mg/kg in cortex of S. sorbifolia, but cucurbitacin D was not. The compounds were shown to exihibit significant cytotoxicity($ED_{50}$<$0.1{\mu}g/mL$) against several tumor cell lines and acute toxicity(cucurbitacin D: 4.7mg/kg/day, cucurbitacin F: 2.5mg/kg/day) against BDF-1 mouse.

  • PDF

Impact Assessment of Climate Change on Extreme Rainfall and I-D-F Analysis (기후변화가 극한강우와 I-D-F 분석에 미치는 영향 평가)

  • Kim, Byung-Sik;Kim, Bo-Kyung;Kyung, Min-Soo;Kim, Hung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.4
    • /
    • pp.379-394
    • /
    • 2008
  • Recently, extreme precipitation events beyond design capacity of hydraulic system have been occurred and this is the causes of failure of hydraulic structure for flood prevention and of severe flood damage. Therefore it is very important to understand temporal and spatial characteristics of extreme precipitation events as well as expected changes in extreme precipitation events and distributional characteristics during design period under future climate change. In this paper, climate change scenarios were used to assess the impacts of future climate change on extreme precipitation. Furthermore, analysis of future extreme precipitation characteristics and I-D-F analysis were carried out. This study used SRES B2 greenhouse gas scenario and YONU CGCM to simulate climatic conditions from 2031 to 2050 and statistical downscaling method was applied to establish weather data from each of observation sites operated by the Korean Meteorological Administration. Then quantile mapping of bias correction methods was carried out by comparing the simulated data with observations for bias correction. In addition Modified Bartlett Lewis Rectangular Pulse(MBLRP) model (Onof and Wheater, 1993; Onof 2000) and adjust method were applied to transform daily precipitation time series data into hourly time series data. Finally, rainfall intensity, duration, and frequency were calculated to draw I-D-F curve. Although there are 66 observation sites in Korea, we consider here the results from only Seoul, Daegu, Jeonju, and Gwangju sites in this paper. From the results we found that the rainfall intensity will be increased and the bigger intensity will be occurred for longer rainfall duration when we compare the climate conditions of 2030s with present conditions.

A Study on the Cooling Load of South and East Facing Apartment Houses (남향과 동향 집합주택의 냉방부하에 관한 연구)

  • 박근우;이경희
    • Journal of the Korean housing association
    • /
    • v.11 no.2
    • /
    • pp.129-137
    • /
    • 2000
  • This study is about the difference of South and East facing Cooling load of Apartment s Houses using Dynamic Heat-flow Calculation. Therefore, the purpose of this study is come in to use Material for the Thermal Environments of Apartment Houses. The results of the analysis are below. (1) For the peak load of degree hour; The highest is "I" unit and the next high load is H, F, E, C, B, G, D and A unit for the south facing Apartment houses. The higher load is "H" unit and the next high load is I, E, F, B, C, G, D, A Unit for the east facing Apartment houses. (2) For the total load of degree day; The highest load is "I" unit and the next high load is H, G, F, E, C, B, D and A Unit for the south facing Apartment houses. The highest load is "H" unit and the next high load is I, G, E, F, B, C, D, A Unit for the east facing Apartment houses. (3) For the total load of degree day; The highest load is "H" Unit for the east facing Apartment houses and the Lowest load is "A" Unit for the south facing Apartment houses.is "A" Unit for the south facing Apartment houses.nt houses.

  • PDF

A Study on D.D.I. Load for Forming of the CNG Storage Vessel (CNG 저장용기의 성형을 위한 D.D.I. 하중에 관한 연구)

  • Lee, Hyun Woo;Bae, Jun Ho;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.6
    • /
    • pp.629-637
    • /
    • 2013
  • In this study, a theoretical analysis method was suggested for predicting forming loads of continuous deep drawing and ironing processes (D.D.I. processes) by considering back tension and continuity equation, and FEA for D.D.I. processes was performed. Dimensions of a punch and a mold on the basis of design rules for a CNG storage vessel were applied for the analysis. To verify the suggested theoretical analysis, the results of theoretical analysis were compared with both those of FEA and experiments of previous studies. As the result of analysis, the values and tendencies of the loads predicted by the theoretical analysis were in agreement with those of FEA and the experiments. So, it is considered that the analysis suggested has reliability for predicting the forming loads of the continuous processes(deep drawing+ironing(1)+ironing(2)).

Practice of Fashion Color Planning - Focus on Color Images of the Bloomsbury Group Paintings for a Color Plan of Company D - (패션 색채기획의 실제 - 'D'사(社) 색채기획을 위한 Bloomsbury Group 회화의 색채 이미지를 중심으로 -)

  • Han, Seung-Hee;Cho, Kyu-Hwa
    • Journal of Fashion Business
    • /
    • v.13 no.4
    • /
    • pp.21-36
    • /
    • 2009
  • The objective of the study is to create color plan for company D based on color images of the Bloomsbury Group paintings, which is an art institute based in Bloomsbury, London, a hometown of the company, to renew the traditional brand image of the company by blending fashion and art. This study analyzed 'D's previous F/W Color planning from 2003 to 2007 through NCS to understand characteristics of company D's color planning. It considered company D's color renewal concept by looking into Bloomsbury Group's backgrounds and pieces. Based on 2008-2009 F/W color trend and the analysis result, the study suggests a color plan with reference to a case study of the company D, for which I work as a colorist. The color renewal of the company D for 2008-2009 F/W season was categorized into theme I. Bloomsbury and theme II. Charleston for planning. The following table summarizes the result of 2008-2009 F/W season color plan with focus on development of new check and print patterns. The significance of the study can be found in that it advanced beyond the color planning stage to be applied to the actual renewal. Through a renewal of an existing brand, a fashion brand can be revitalized to have distinguished competitiveness.