• Title/Summary/Keyword: I-131

Search Result 1,078, Processing Time 0.033 seconds

The Clinical Study on the Effects of $Tapazole^{(R)}\;upon\;^{131}I$ Uptake in Hyperthyroidism (갑상선(甲狀腺) 기능항진증(機能亢進症)에서 $Tapazole^{(R)}$$^{131}I$섭취율(攝取率)에 미치는 영향(影響)에 관(關)한 임상적(臨床的) 고찰(考察))

  • Ro, Heung-Kyu;Lee, Jung-Sang;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.2
    • /
    • pp.17-22
    • /
    • 1969
  • The differences in the change of the uptake rate of radioactive iodine ($^{131}I$) in the thyroid gland after $Tapazole^{(R)}$ administration before $^{131}I$ treatment were analysed in 137 patients who were diagnosed as diffuse toxic goiter in the Radioisotope Clinic and Laboratory, Seoul National University Hospital since Jan. 1967 to July, 1969. The uptake rate of the therapeutic dose of $^{131}I$ was changed diffusely compared with that of the trace dose in the patients who had no $Tapazole^{(R)}$ administration before $^{131}I$ treatment. In those patients who had $Tapazole^{(R)}$ more than 20 mg/day for more than one week before $^{131}I$ treatment, the uptake rate was decreased significantly. When the patients discontinued the administration of $Tapazole^{(R)}$ 7 days prior to $^{131}I$ treatment, the uptake rate was increased in all cases.

  • PDF

Radioiodine Therapy in a Patient with Papillary Thyroid Carcinoma associated with Breast Uptake; Hyperprolactinemia due to Empty Sella Syndrome (유즙분비가 있는 갑상선암 환자에서 I-131 치료)

  • Pai, Moonsun;Park, Chan H.;Suh, Jung-Ho;Kim, Kyung-Rae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.109-113
    • /
    • 1998
  • We report a 37 year-old-female patient with papillary thyroid cancer treated by surgery who demonstrated residual thyroid and bilateral breast uptake on a diagnostic I-131 whole body scan. She had an extrathyroidal extension needing I-131 ablative therapy. Her galactorrhea was investigated and treated with low doses of bromocriptine prior to I-131 therapy. Her galactorrhea was due to the decreased secretion of PIF induced by empty sella.

  • PDF

Comparison of I-131 Scintigraphy, T1-201 Scintigraphy, and Serum Thyroglobulin in the Postoperative Follow-Up of Differentiated Thyroid Cancer (분화된 갑상선암의 수술후 경과관찰에서 I-131 스캔, T1-201 스캔 및 혈청 갑상선 글로불린 농도의 비교)

  • Lee, Hyun-Kyung;Song, Jae-Soon;Shinn, Joon-Jae;You, Kye-Hwa;Cha, Wang-Ki;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.346-355
    • /
    • 1997
  • To evaluate the utility of I-131, T1-201 scintigraphy, and serum thyroglobulin(Tg) in the follow-up of differentiated thyroid cancer, we compared retrospectively the data from 33 patients who underwent total or subtotal thyroidectomy. I-131 scintigraphy was performed after optimal endogenous TSH stimulation ($TSH>50{\mu}U/ml$). Total 41 cases of I-131 and T1-201 scintigraphy pairs were examined. Concomitant serum thyroglobulin levels were measured for 41 pairs of scan. Tg-off levels(that measured after discontinuation of the thyroid hormone) higher than 40ng/m1 were considered positive, and Tg-on levels(that measured during the thyroid hormone replacement) higher than 5ng/ml were considered positive. The concordance rates between I-131 therapeutic scintigraphy and T1-201 scintigraphy was 48% in the 38 case of total scan pairs(59% in the 17 cases of postoperative preablation group, and 38% in the 21 cases of postoperative postablation group). Of 17 studies before the I-131 ablation therapy(preablation group), 7 showed positive I-131 therapeutic scintigraphy despite of negative T1-201 scintigraphy. Among patients with negative I-131 therapeutic scintigraphy, no patients had abnormal T1-201 uptake. However, of 21 studies which were done after radioiodine therapy(postablation group) 6 had abnormal uptake on T1-201 scintigraphy which were not seen on I-131 therapeutic scintigraphy, and Tg-off levels also elevated in this 4 of 6 cases. As a result, I-131 therapeutic scintigraphy showed highest positive rate at postoperative preablation follow-up study in differentiated thyroid cancer patients. T1-201 scintigraphy may be useful in postablation studies, and the use of the combined modalities(T1-201 and Tg levels) provides a higher diagnostic yield.

  • PDF

Ablation of Remnant Thyroid Tissue with I-131 in Well Differentiated Thyroid Cancer After Surgery (분화성 갑상선암에서 수술 후 I-131을 이용한 잔여 갑상선 조직의 제거 성적)

  • Kim, Yu-Kyeong;Lee, Dong-Soo;Cho, Bo-Yeon;Jeong, Jae-Min;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.339-345
    • /
    • 1997
  • To evaluate the effectiveness of I-131 in ablation of residual thyroid tissue, we analyzed 350 patients with thyroid cancer who were treated with various doses of I-131 after surgery for thyroid cancer Two hundred fifty five patients were treated with 1.1GBq(30mCi) of I-131 for ablation of remnant thyroid and one hundred seventeen patients received more than 2.8GBq(75mCi) of I-131. We determined the effectiveness of ablation by following I-131 whole body scan. Absent visible uptake or minimal uptake in thyroid tissue were considered as successful ablation. Of 255 patients who received doses of 30mCi I-131 therapy, 131 patients(51%) showed successful ablation of residual thyroid tissue with $2.6{\pm}1.7$ times of I-131 therapy. Of 117 patients who received doses of the more than 75mCi I-131, 84 patients(72%) had successful remnant thyroid ablation with $1.6{\pm}1.1$ times of I-131 therapy, According to the extent of surgery, successful ablation rates were 78%, 62%, 54%, 33% in patients who underwent total thyroidectomy, subtotal thyroidectomy, lobectomy and isthmectomy, lobectomy or tumorectomy, respectively. This study showed that ablation of remnant thyroid after surgery with 30mCi I-131 was successful only in 50%. Therefore, in cases of patients with high risk for recurrence, we recommend high dose I-131 for ablation of remnant after total thyroidectomy.

  • PDF

Experimental Study in Detection of Inflammation with I-131 labeled IgG (I-131 표지 IgG를 이용한 염증 진단의 실험적 연구)

  • Kim, Deog-Yoon;Kim, Sang-Eun;Lee, Dong-Su;Ahn, Cu-Rie;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.259-265
    • /
    • 1991
  • The purpose of this study is to investigate the ability of I-131 labeled polyclonal human immunoglobulin to localize an infection. In our country, indium-111 labeled leukocyte or Tc-99m labeled IgG are not readily available because of compex, time-consuming procedure and cost. So we tried to localize infection with I-131 labeled IgG which could be easily prepared. Six rats, infected with staphylococcus aureus in a thigh muscle, received I-131 labeled IgG intravenously and I-131 labeled bovine serum albumin (BSA) were injected to other 5 infected rats. Scintigrams were made at 1, 4, 24, 48, 72 hour later. The radiopharmaceutical demonstrated significant accumulation at the site of infection. The accumulation of I-131 labeled IgG at the site of infection was significantly (P<0.05) higher than that of I-131 labeled BSA at 48, 72 hour. Similar finding could be found at 24 hour imaging, but it was not significant statistically. Therefore it was found that vascular permeability alone could not account for the mode of action of I-131 labeled IgG and it was considered that specific binding played a role. In conclusion, focal sites of inflammation can be detected with I-131 labeled nonspecific human polyclonal IgG and it seems that this method can also be applied to localization of human infection.

  • PDF

Synthesis of oleyl-4[131I]-iodobenzoate for long-term cell trafficking

  • Jeon, Hak Rim;Lee, Woonghee;Oh, Jieun;Lee, Yong Jin;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.45-50
    • /
    • 2018
  • Great efforts are currently devoted to the development of new approaches for the labeling of cells using appropriate radionuclides. While fluoride-18 and copper-64 have been extensively studied as short-term and intermediate-term trafficking agents, iodide was studied less intensely. Here, we report a new cell labeling agent labeled with $^{131}I$, $[^{131}I]$oleyl-4-iodobenzoate ($[^{131}I]$OIB) for long-term cell trafficking. A precursor of $[^{131}I]$OIB was obtained in two steps, with the yield of 35%. The radiochemical yield of $[^{131}I]$OIB was over 50%. While $[^{131}I]$OIB could label different cells, L6 cells showed the highest cell-labeling efficiency. The $[^{131}I]$OIB-labeled L6 cells were imprinted into a rat heart, and then monitored noninvasively for 2 weeks by gamma camera imaging. We conclude that $[^{131}I]$OIB is a good candidate molecule for a long-term cell trafficking agent.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Studies on the Effects of Injected Amount of I131 in Uptake and Release Rate by Thyroid in Guinea Pigs 1. On the Influence of Injected Amount of Redioiodine-131 in Uptake and Release Rate by Thyroid in Male Guinea Pigs (방사성옥도(放射性沃度)(I131)의 주입량(注入量)이 기니픽 갑상선(甲狀腺)에의 섭취(攝取) 및 방출률(放出率)에 미치는 영향(影響)에 관(關)한 연구(硏究) 제(第)1보(報) 방사성옥도(放射性沃度)(I131)의 주입량(注入量)이 웅(雄)기니픽 갑상선(甲狀腺)에서의 섭취(攝取) 및 방출률(放出率)에 미치는 영향(影響))

  • Chung, Yung Chai;Shim, Sang Chil;Lee, Heung Shik
    • Korean Journal of Veterinary Research
    • /
    • v.6 no.1
    • /
    • pp.24-30
    • /
    • 1966
  • In order to observe the effect of the injected radioactive iodine-$I^{131}$ on the uptake in thyroid of normal male guinea pigs and P.B.$I^{131}$ conversion ratio of $I^{131}$ in serum, 24 matured male guinea pigs were divided in 4 groups and $35{\mu}c$, $70{\mu}c$, $140{\mu}c$ and $280{\mu}c$ per kg of body weight respectively were injected subcutaneously. 1. The uptake rates of radioactveiodine-$I^{131}$ by external counts of thyroidal uptake reached the maximum level of uptake in 24 hours after injection. 2. As the injected amount increases, the uptake rates of maximum levels and release rate were increased. 3. Uptake rate in the removed thyroid have shown no statistical in the $35{\mu}c$ and $70{\mu}c$ groups of injected guinea pigs. 4. There was no statistical significance in $140{\mu}c$ and $280{\mu}c$ groups of injected guinea pigs. 5. P.B.$I^{131}$ conversion ratio of $I^{131}$ in serum was not in proportion to injected amounts: 61.0%(35), 70.2%(70), 75.3%(140) and 64.8%(280).

  • PDF

Indigenous Radiosynthesis of [131I]Iodobenzylguanidine ([131I]mIBG) for Neuroblastoma Imaging

  • Nadeem Ahmed Lodhi;Muhammad Irfan;Muhammad Nasir Saddique;Kahkshan Bashir Mir;Naseer Ahmed;Shazia Fatima;Mumtaz Khan;Muhammad Wasim;Samina Roohi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.71-76
    • /
    • 2022
  • Indigenous diagnostic dose of 131I-labeled meta-iodobenzylguanidine ([131I]mIBG) was prepared via Cu+ catalyzed isotope exchange reaction generated in situ by sodium metabisulfite for imaging of neuroblastoma tumor. [131I]mIBG was produced in overall 85-90% radiochemical yield. The average amount of radioactivity of [131I]mIBG was 2164 MBq (1998-2331MBq) with an average specific activity > 1000 MBq/mg at the end of synthesis. The radiochemical purity was ≥ 99.9% after purification through Dowex-1 × 8 ion exchange resin (100-150 mesh) at the date of preparation. The stability of [131I]mIBG at concentration 480-555 MBq/mL was > 97% at 4 ℃ after 4 days. The room temperature (25 ℃) stability of [131I]mIBG was > 98% after 24 h. Biodistribution of [131I]mIBG in patient showed uptake in salivary glands, liver, spleen and excreted though urinary bladder. Neuroendocrine medicated uptake into tumor lesion and metastatic sites were noted which strongly correlate with the morphological abnormalities of patient.

Purity Test of $Hippuran^{131}$I by Chromatography (크로마토그래프법에 의한 $Hippuran^{131}$-I의 순도시험)

  • 김순옥
    • YAKHAK HOEJI
    • /
    • v.21 no.2
    • /
    • pp.110-114
    • /
    • 1977
  • The purified .omicron.-iodobenzoic acid-$^{131}$ I, sodium iodide-$^{131}$I and mixtures of those compounds were applied to radio paper or radio thin layer chromatography to select the developing solvents with useful separation efficiency. The separation efficiencies were checked by radiochromatogram sacnnings. It has been found that the two dimensional radio paper chromatogrphy using the solvent systems of 8% phenol and butanol-glacial acid-water (4:1:1 v/v) and the radio thin layer chromatography using alumina gel plate and butanol- glacial acetic acid- water (4:1:1 v/v) are both efficient. In this method, the Rf value of .omicron.-iodobenzoic acid-$^{131}$ I and the unbound $^{131}$ I is 0.48, 0.85 and 0.15, respectively.

  • PDF