• 제목/요약/키워드: I%2FI analysis

검색결과 17건 처리시간 0.029초

Cross-Technology Localization: Leveraging Commodity WiFi to Localize Non-WiFi Device

  • Zhang, Dian;Zhang, Rujun;Guo, Haizhou;Xiang, Peng;Guo, Xiaonan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권11호
    • /
    • pp.3950-3969
    • /
    • 2021
  • Radio Frequency (RF)-based indoor localization technologies play significant roles in various Internet of Things (IoT) services (e.g., location-based service). Most such technologies require that all the devices comply with a specified technology (e.g., WiFi, ZigBee, and Bluetooth). However, this requirement limits its application scenarios in today's IoT context where multiple devices complied with different standards coexist in a shared environment. To bridge the gap, in this paper, we propose a cross-technology localization approach, which is able to localize target nodes using a different type of devices. Specifically, the proposed framework reuses the existing WiFi infrastructure without introducing additional cost to localize Non-WiFi device (i.e., ZigBee). The key idea is to leverage the interference between devices that share the same operating frequency (e.g., 2.4GHz). Such interference exhibits unique patterns that depend on the target device's location, thus it can be leveraged for cross-technology localization. The proposed framework uses Principal Components Analysis (PCA) to extract salient features of the received WiFi signals, and leverages Dynamic Time Warping (DTW), Gradient Boosting Regression Tree (GBRT) to improve the robustness of our system. We conduct experiments in real scenario and investigate the impact of different factors. Experimental results show that the average localization accuracy of our prototype can reach 1.54m, which demonstrates a promising direction of building cross-technology technologies to fulfill the needs of modern IoT context.

다층 건물을 위한 Wi-Fi 기반의 저 복잡도 층간 위치 측위 기법 (Wi-Fi-Based Low-Complexity Floor Number Determination Method Based for Multistory Buildings)

  • 석건;리향;정홍규;김진오;신요안
    • 대한기계학회논문집A
    • /
    • 제38권2호
    • /
    • pp.149-156
    • /
    • 2014
  • 최근 들어, 다층 건물 내 층간 위치 측위(Floor Determination)는 다양한 위치 기반 응용 서비스를 만족하기 위해 빠르게 해결해야 되는 문제가 되었다. 본 논문에서는 다층 건물 환경에서 Wi-Fi 신호를 기반으로 한 저복잡도 층간 위치 측위 기법을 제안한다. 제안 기법에서는 WAP(Wireless Access Point)에 대한 자세한 좌표 정보가 필요 없이, 사용자 단말기에 나온 각 WAP의 층수와 각 WAP의 수신 신호 세기(Received Signal Strength) 값만을 이용한다. 제안 기법의 성능을 검증하기 위해 본 논문에서는 Multi-Wall-Floor 모델을 사용하였으며, 모의실험 결과를 통해 각층의 WAP 배치 밀도가 충분히 높을 경우 제안 기법의 정확도가 100%에 도달함을 보였다. 그리고 각층의 WAP 수가 적은 경우에서도 우수한 층간 위치 측위 성능을 보였으며, 특히 심지어 WAP 가 하나도 없는 층이 있어도 층간 위치 측위가 가능한 것을 보임으로써 제안된 기법의 우수성을 확인하였다.

모바일 플랫폼을 위한 네트워크 환경 측정 시스템 설계 및 구현 (The Design and Implementation of Network Measurement System for Mobile Platforms)

  • 김강희;여진주;김진혁;최상방
    • 전자공학회논문지
    • /
    • 제50권2호
    • /
    • pp.35-46
    • /
    • 2013
  • 모바일 네트워크 사용량이 급증함에 따라 트래픽 수요 문제를 해결하기 위한 많은 연구가 이뤄지고 있다. 특히 네트워크 환경 측정 분야는 정확한 분석을 통해 네트워크상에 발생되는 문제들의 원인을 찾아냄으로써 트래픽 수요 문제를 해결할 수 있는 기반을 제공한다. 특히 최근 스마트폰의 수요가 늘어남에 따라 모바일 플랫폼 특성이 네트워크에 미치는 영향을 고려한 측정시스템이 필요하다. 이에 본 논문에서는 모바일 플랫폼을 위한 네트워크 환경 측정 시스템을 설계하였다. 설계된 시스템은 클라이언트를 통하여 얻은 패킷의 정보를 통하여 패킷 전송간의 지연시간과 throughput을 실시간으로 계산한다. 그리고 측정시 클라이언트인 모바일 단말기에 요구되는 계산량을 줄임으로써 모바일 단말기에 걸리는 부하를 최소화하였다. 설계한 시스템을 통하여 네트워크 자원을 최대로 사용하였을 시 Wi-Fi 망이 3G 망보다 짧은 전송지연시간, 높은 최대 throughput, 낮은 손실률을 가지고, Android가 iOS보다 짧은 전송지연시간과 높은 최대 throughput을 가지며, UDP가 TCP보다 긴 전송지연시간, 높은 최대 throughput을 가진다는 것을 확인하였다.

Study on the Inclusion Behavior of Sulfobutylether-β-Cyclodextrin with Perphenazine by Flow Injection Chemiluminescence

  • Shen, Minxia;Lv, Hairu;Song, Zhenghua
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3199-3205
    • /
    • 2013
  • The inclusion behavior of sulfobutylether-${\beta}$-cyclodextrin (SBE-${\beta}$-CD) with perphenazine (PPH) was first studied by flow injection (FI)-chemiluminescence (CL) analysis with proposed $lg[(I_0-I_s)/I_s]=lgK_{P-CD}+nlg[C_{PPH}]$ model and molecular docking. Results showed that a 1:1 complex of SBE-${\beta}$-CD/PPH could online form, with the formation constant $K_{P-CD}$ of $2.57{\times}10^7Lmol^{-1}$ at 298 K. The thermodynamic parameters showed that the inclusion behavior of SBE-${\beta}$-CD/PPH was a spontaneous process by hydrophobic interaction. The molecular docking results revealed PPH entered into the larger cavity of SBE-${\beta}$-CD with two hydrogen bonds. Based on the linear relationship of the decrement of luminol/SBE-${\beta}$-CD/PPH CL intensity against the logarithm of PPH concentration ranging from 0.03 to 30.0 ng $mL^{-1}$, the present FI-CL analysis using luminol/SBE-${\beta}$-CD/PPH system was successfully applied to PPH determination in biological fluids and tablets with recoveries from 94.5 to 105.6% and RSDs less than 2.6% (n = 5).

Glass Ionomer Cement의 방사선 불투과성에 관한 연구 (A STUDY ON THE RADIOPACITY OF GLASS IONOMER CEMENTS)

  • 박수경;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.122-132
    • /
    • 1993
  • The aim of this study was to investigate the level of radiopacity of glass ionomer cements and to determine the optimum level of radiopacity that is the most compatible with the radiographic diagnosis of secondary caries. The experiments were performed in two parts. In the first part, the radiopacities of 9 glass ionomer cements (FI, FII, FI-LC, FII-LC, SI, SII, Vit, B-VLC, AC) and base materials(Ultra-Blend, Zinc phoaphate cements, Cavitec, Dycal) were measured by densitometer. Then all experimental materials were divided into 5 groups based on the level of radiopacity of enamel and dentin. In the second part, class III cavities with or without secondary caries were prepared in extracted anterior teeth. The representative materials of each group with different radiopacities were inserted into each cavity. The radiographs were interpreted by 15 dentists and seconsary caries were diagnosed according to a five-point confidence rating. Sensitivity and ROC analysis were used to compare observer performance. The following results were obtained : 1. The radipacity of glass ionomer cements varied between 1.111mm Al and 6.011mm Al equivalent. 2. Among experimental materials, three materials in group I had lower radiopacity than that of dentin. The radiopacity of two materials in group II slightly exeeded that of dentin. Three materials in group III had slightly lower radiopacity than that on enamel. The radiopacity of one material in group W was slightly higher than that of enamel. Four materals in group V had the radiopacity that exeeded over 2.0mm AI equivalent to that of enamel. 3. The group IV was the highest for sensitivity and the group V was the highest for ROC area. However, no significant differences were obtained among group II, III, IV and V (P<0.05) but only group I was significantly lower(P<0.01). 4. In comparison with the observer performance for the radiographic diagnosis of secondary caries, the group II, III, IV, and V were superior to the group I (P<0.01). And so the optimum level of radiopacity to detect the secondary caries was the radiopacity that is higher than that of dentin.

  • PDF

Salmonella typhi KNIH100으로부터 aroD 유전자의 클로닝과 염기서열 분석 (Cloning and Nucleotide Sequence Analysis of the aroD Gene from Salmonella typhi KNIHI100)

  • 길영식;전형규;신희정;김영창
    • 미생물학회지
    • /
    • 제36권3호
    • /
    • pp.187-191
    • /
    • 2000
  • 장티푸스는 Salmonella typhi 에 의해 유발되는 장감염성 질환으로 사람과 동물에 공통되는 질병이다. 본 연구에서는 기 보고된Salmonella typhi KNH100의 염색체 DNA로부 터 방향족 아미노산의 생합성에 관여하는 효소인 3-dehydroquinate hydratase(3- dehydroquinate)를 암호화하는 aroD 유전자를 포함하는 약 3.2 kb의 Sal I 절편을 pSAL62 이라 명명하였다. 클로닝된 재조합 plasmid인 pSAL61에는 ATG 개시코돈과 TGA 종결코돈 을 포함하는 759 염기로 구성된 aroD 유전자가 위치하고 있었다. 또한 S. typhi Ty2, Shigella dysenteriae, 그리고 Escherichia coli 등 다른 장내 세균의 aroD 유전자와 상동성을 비교하여 본 결과 각각 90%, 72.7% 그리고 73%의 상동성을 나타내었다.

  • PDF

맞춤형 야구복의 효율적 생산관리를 위한 공정관리 분석 (Process Control Analysis for Efficient Production Management of Customized Baseball Uniforms)

  • 최경미;황현정;전정일;박용수
    • 한국의류산업학회지
    • /
    • 제14권4호
    • /
    • pp.597-606
    • /
    • 2012
  • To increase the productivity and product quality of customized baseball jerseys, this study developed a multi-variable system for a production process that efficiently controls diverse production management factors. The working time was measured through the establishment of a standard process where skilled workers and Chinese factory workers manufactured 5 sets of the same basic design jerseys. Based on the measured working time (1,136 seconds/per unit), the multi-variable process control system was developed, where hourly production management is possible according to the involved workers and equipment types. Each process was assigned accoding to the production management factors for a total of 28 standard processes. The processes were developed based on consideration of work characteristics according to the order of needlework of open-type set baseball jerseys with sleeves(the basic design of baseball jerseys)to result in a customized production system structure that could be set up with multi-variables. As a result, a total 12 types of systems were developed in consideration of the personnel involved and the number of equipments. The optimal production management system (with the highest efficiency compared to the number of workers)was A-2, B-1, C-1. D-2, E-2, F-1, and G-1. This system had extremely high efficiency and showed 99% assignment efficiency for the 7-person team. Though not optimal, possible process assignment for each working personnel is proposed as a reserve process in case work modification is inevitable due to malfunctions and the absence of equipments.

안드로이드 통신모듈 및 센서를 이용한 가속에 따른 이동방법 산출 시스템 (Using the Android Communication Module and Sensor the Movement Method Output System of According to Accelerated)

  • 박성현;장기만;육정수;허태상;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.672-674
    • /
    • 2014
  • 모바일 통신 기술의 하나인 GPS 기술이 발달됨에 따라, 스마트폰, 테블릿PC와 같은 모바일 기기에 GPS기능이 필수적으로 탑재되고 있다. 이에 사용자들은 GPS 센서의 현재 위치를 기반으로 하는 앱 어플리케이션 서비스를 통해 길 찾기, 현재 자신의 속도 등 여러 정보를 주고받을 수 있게 되었다. 이에, 본 논문에서는 모바일 기기의 통신 모듈인 Wi-Fi 및 Mobile Network, GPS, 가속 센서를 이용하여 2차원적 위치 및 3차원적 고도에 따른 알고리즘을 분석 및 산출하여, 사용자가 현재 이용하고 있는 이동수단의 정보를 전달하는 시스템을 제안한다. 이는, 특정 이동수단을 이용하고 있는 사용자에게 불필요한 정보를 제공하지 않는 광고시스템이나 재난정보시스템, 의료분야 등 각종 분야에 적용 할 수 있을 것이라 사료된다.

  • PDF

원전 내 무선통신 적용에 대한 전자파 적합성 평가방법 분석 (Analysis on the EMC evaluating method for applying wireless communications in NPP)

  • 강승석;임태흥;주재율;김형태;김대희;변강일;박종언;이준용;추호성
    • 한국정보통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.2221-2231
    • /
    • 2017
  • 본 논문에서는 원전용 계측 제어기기를 진단하고 유지 보수하기 위한 무선통신기술의 국내외 적용 사례, 프로토콜(Wi-Fi, Zigbee, Z-wave, WirelessHart 등) 및 그에 따른 전파특성을 조사하였다. 또한, 원전 내 무선통신기술 적용시 우려되는 전자파 간섭(EMI/RFI)과 관련하여 국내 규제지침 KINS/RG-N03.09(개정 2판)에서 승인한 RG. 1.180(Regulatory Guide 1.180 rev.1), MIL-STD 461E, 및 IEC 61000-4의 차이를 분석하였다. 추가적으로 기존의 EMC 관련 규제에 포함되어 있지 않았던, 실내 환경에서의 구조적 특징, 전파산란 및 차폐효과, 실내 감쇄모델을 고려한 전자파 영향성 평가요소에 대해서도 연구하였다.

패혈성 폐가 유도된 신생자돈에서 외인성 Nitric Oxide 흡입의 혈역학, 가스교환 및 폐 염증에 대한 효과 (Effect of Inhaled Nitric Oxide on Hemodynamics, Gas Exchange and Pulmonary Inflammation in Newborn Piglets with Escherichia coli Induced Septic Lungs)

  • 장윤실;고선영;박원순
    • Clinical and Experimental Pediatrics
    • /
    • 제46권8호
    • /
    • pp.777-783
    • /
    • 2003
  • 목 적 : E. coli 패혈성 폐가 유도된 신생자돈에서 Nitric oxide(NO) 가스 흡입요법이 혈역학, 가스교환 및 폐 염증 소견에 미치는 영향을 알아보고자 본 연구를 실시하였다. 방 법 : 23마리의 신생자돈에서 도관 삽입과 기도 삽관을 시행하여 기계적 가스 인공환기를 시키면서 CON군(n=6)은 생리적 식염수 5 mL, PCON(n=9) 및 PNO(n=8) 군은 Escherichia coli strain $69{\times}10^9cfu$(10 mL)를 투여한 후 time-cycled pressure-limited 인공환기기로 PIP 30 $cmH_2O$, 호흡수 분당 30회, $FiO_2$ 1.0, PEEP 4 $cmH_2O$의 설정에서 6시간 동안 유지하였다. PNO군에서는 NO 10 ppm을 E. coli 투여 후부터 실험 종료 시까지 기도 내로 투여하였다. 모든 신생자돈에서 가스교환, 혈역학, 폐기능 지수들을 1시간 간격으로 측정하였고 실험 종료후 폐 조직을 얻어 염증반응 정도 지표인 myeloperoxidase 활성을 측정하였다. 결 과 : E. coli가 기도 내로 투여된 PCON 및 PNO군 모두에서 실험 종료시 E. coli 패혈증이 발생하였다. PCON군에서는 시간에 따라 진행되는 폐동맥 고혈압, 저산소혈증, 고탄산혈증, 및 폐 내 단락과 폐 내 사강의 비율의 증가를 보였고 대조군에서는 실험 종료시까지 의미 있는 변화를 보이지 않았다. NO가 투여된 PNO군에서 폐동맥 고혈압이 감소되지 않았으나 폐 내 단락의 의미 있는 개선과 폐 내 사강 비율 증가의 일부 감소에 기인한 저산소혈증 진행의 완화가 관찰되었다. 폐 염증정도의 지표인 폐조직의 myeloperoxidase 활성도는 PCON군에서 CON군에 비해 의미 있게 증가되었으며 이는 PNO군에서 의미 있게 완화되었다. 결 론 : E. coli 패혈성 폐가 유도된 신생자돈에서 NO 가스 흡입요법은 폐 내 단락 개선을 통해 산소화를 향상시켰으며 또한 폐 염증 소견을 완화시켰다.