• Title/Summary/Keyword: Hysteresis width

Search Result 86, Processing Time 0.024 seconds

Current Controlled PWM for Multilevel Voltage-Source Inverters with Variable and Constant Switching Frequency Regulation Techniques: A Review

  • Gawande, S.P.;Ramteke, M.R.
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.302-314
    • /
    • 2014
  • Due to advancements in power electronics and inverter topologies, the current controlled multilevel voltage-source pulse width modulated (PWM) inverter is usually preferred for accurate control, quick response and high dynamic performance. A multilevel topology approach is found to be best suited for overcoming many problems arising from the use of high power converters. This paper presents a comprehensive review and comparative study of several current control (CC) techniques for multilevel inverters with a special emphasis on various approaches of the hysteresis current controller. Since the hysteresis CC technique poses a problem of variable switching frequency, a ramp-comparator controller and a predictive controller to attain constant switching frequency are described along with its quantitative comparison. Furthermore, various methods have been reviewed to achieve hysteresis current control PWM with constant switching frequency operation. This paper complies various guidelines to choose a particular method suitable for application at a given power level, switching frequency and dynamic response.

Hysteresis loss of YBCO thin film strip with filamentary structure (필라멘트 구조의 YBCO 박막의 자기이력 손실)

  • Park H. W;Na D. H;Kim M. J;Chang Y. S;Kim J. M;Ri H.-C;Lee Y. H
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.99-103
    • /
    • 2005
  • For ac applications a detailed understanding of the ac power losses associated with different conductor configurations is of crucial importance. YBCO thin films were divided into parallel filaments with widths of 1, 2, and 4 mm to reduce hysteresis losses. The measured hysteresis losses show a linear relationship between the strip width and hysteresis loss as anticipated. The influence of different inter-filament separations on the hysteresis loss is investigated.

  • PDF

Magnetic Exchange Coupling at The Interface of MR/TbCo Thin Films (자기저항 헤드용 MR/TbCo 박막의 자기교환 결합)

  • 서정교;조순철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 1996
  • To simulate the characteristics of magnetic exchange coupling at the interface of MR/TbCo thin films, the directions of magnetizations were calculated by minimizing energy in the films. Newton method and Gauss-Seidel method were used. The width of M-H curve increased with TbCo anisotropy constant, and with the thickness of the transition region of TbCo layer. Hysteresis loop width became extremely narrow (less than 10 Oe of coercivity), when the TbCo transition region length was $400\;\AA$. Also the hysteresis loop of films with low interfacial exchange coupling constant was similiar to that of short transition region length. When interfacial exchange coupling constant was 1/100 of perfect coupling, hysteresis loop showed a coercivity of less than 10 Oe. Comparing the measured hysteresis loop of a fabricated sample with that of simulated one, exchange coupling con¬stant could be estimated.

  • PDF

Effects of Microstructure on the Magnetic Properties of Mg-ferrite Sintered Body (미세 구조가 Mg-페라이트 소결체의 자성에 미치는 영향)

  • 김성재;정명득;백종규
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.4
    • /
    • pp.436-440
    • /
    • 1995
  • Effects of microstructure of two Mg-ferrite specimens with the same starting composition and relative density but with different grain size on B-H hysteresis loop, natural resonance frequency, and ferromagnetic resonance line width are reported. Such properties as B-H hysteresis loop, saturation magnetization, natural resonance frequency, and ferromagnetic resonance line width were influenced by the microstructure development during sintering. Large grain size specimen showed high saturation magnetization, low coercive force, low natural resonance frequency, and low ferromagnetic resonance line width compared with the specimen of small grain size. The main reason for the changes in properties can be explained by the variation in anisotropic characteristics due to Fe+2 content generated during sintering process.

  • PDF

A Voltage Bus Conditioner for a High Voltage DC Power Distribution System using High Performance Hysteresis Control (고성능 히스테리 제어를 이용한 고전압 DC 전력시스템을 위한 Voltage Bus Conditioner)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.90-98
    • /
    • 2007
  • More and All-Electric Aircraft (AEA) carry many loads with varied functions. In particular, there may be large pulsed loads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converter with inductive storage is used as a voltage bus conditioner (VBC) to mitigate voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a VBC is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package, The proposed hysteresis control results in the shortest and the smallest excursions.

Improved Hysteresis Current Control Regulator for High-efficiency Switching (고효율 스위칭을 위한 개선된 히스테리시스 전류제어기)

  • Hong, Sun-Ki;Park, Jin-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1606-1610
    • /
    • 2012
  • Hysteresis current regulator has been used widely because of its simple principle and structure. However, when the current band width is too narrow or the applied voltage is relatively too high, the switching frequency may increase abruptly and it generates a large amount of heat. Thus, this study will suggest a better and simple method to reduce the switching frequency. For single phase current control, the proposed hysteresis current control is executed by adding 0 mode state and comparing the slope of the current reference. This simple method decreases the generated switching frequency and significantly reduces the generated heat. This proposed method was proved with simulations and experiments comparing with the classical hysteresis current control method.

A Variable Hysteresis Control for a DC Bus Conditioner (DC Bus Conditioner을 위한 카변히스테리시스제어)

  • La, Jae-Du;Han, Moon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.472-475
    • /
    • 2008
  • A DC distributed power system(DPS) has many loads with varied functions. In particular, there may be large pulsed toads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converts with inductive storage is used as a DC bus conditioner to damp voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a DC bus conditioner is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package. The proposed hysteresis control results in the shortest and the smallest excursions.

  • PDF

Influence of width and lateral separation of the strips on AC Loss in subdivided YBCO thin film (필라멘트 구조로 분리된 YBCO 박막에서 필라멘트 넓이와 간격이 교류손실에 미치는 영향)

  • Na D. H;Park H. W;Kim M. J;Chang Y. S;Kim J. M;Ri H. C;Lee Y. H
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.32-36
    • /
    • 2004
  • To investigate the influence of strip width and inter-strip separation on the ac loss, arrays of parallel strips with different widths and separations were prepared. Studies on the hysteresis-loss characteristics of multifilamentary YBCO films were performed. The local magnetic field due to magnetization currents is measured by a scanning Hall probe microscope. Based on these results a conceptual design for a low loss YBCO coated conductor is suggested.

  • PDF

Static Var Compensator Using Current Source PWM Converter (전류형 PWN 콘버어터의 희한 정지형 무효전력 보상장치에 관한연구)

  • 김철우;권순재;김광태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.11
    • /
    • pp.1183-1190
    • /
    • 1990
  • In this paper, instantaneous reactive power compensation algorithm is proposed and analyzed. The static Var generator developed in this paper is the current source PWM converter using hysteresis comparator method, which compensates the reactive power by detecting each instantaneous phase voltage and line current, independently. Some aspects on the static Var compensator-such as inductance, capacitance, hysteresis width, and switching frequency, etc.-are discussed. The dynamic performances are examined through digital simulation and experimental test.

  • PDF

Bus Clamping PWM Based Hysteresis Current Controlled VSI Fed Induction Motor Drive with Nearly Constant Switching Frequency

  • Peter, Joseph;Mohammed Shafi, KP;Ramchand, Rijil
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1523-1534
    • /
    • 2017
  • A Current Error Space Phasor (CESP) based hysteresis controller with online computation of the boundary for two-level inverter fed Induction Motor (IM) drives is presented in this paper. The stator voltages estimated along the ${\alpha}$-and ${\beta}$-axes and the orthogonal current error components of the motor are used in the online computation of the hysteresis boundary. All of the inherent benefits of space phasor based hysteresis controllers such as its quick dynamic response and nearby voltage vector switching are present in the proposed scheme with the added benefit of suppressing switching frequency variations. The similarity in the frequency spectrum of the phase voltage obtained at the output of the inverter using the proposed scheme and Bus Clamping Pulse Width Modulation (BCPWM) based drive is justified with the help of extensive MATLAB SIMULINK simulations. The controller is experimentally verified with a three phase, 2.2 kW IM drive for steady state and transient conditions and the obtained results match the simulation results.