• Title/Summary/Keyword: Hysteresis Characteristic

Search Result 183, Processing Time 0.035 seconds

Effect on Matric Suction in Soils due to Hysteretic Soil Water Characteristic Curves (함수특성곡선 이력현상이 지반 내 모관흡수력에 미치는 영향)

  • Kim, Jae-Hong;Hwang, Woong-Ki;Song, Young-Suk;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.4
    • /
    • pp.91-100
    • /
    • 2012
  • Soil-water characteristic curves (SWCCs), which represent a physical property in partially saturated soils, show the relation between volumetric water content and matric suction. The SWCCs exhibit hysteresis during wetting and drying, however experimental expressions used to describe SWCCs have generally ignored the hysteresis. In addition, the shape of SWCC may depend on the void ratio which is changed by soil skeleton deformations or hysteretic behavior under various loading conditions. Hence, it is necessary to understand, both empirically and analytically, the relationship between soil skeleton deformations and the SWCCs of various soils. The typical SWCCs experimentally have drying, wetting, and the second drying curve. The measurement of a complete set of hysteretic curves is severely time-consuming and difficult works, then the first drying curve of SWCC is generally determined to estimate the hydraulic conductivity and shear strength function of partially saturated soils. This paper presents the hydraulic-mechanical behavior of partially saturated soils (weathered soil and silty soil) for volume changes and hysteresis in SWCCs regarding the difference between the first drying and wetting curve.

Analysis on Fault Current Limiting Characteristics of a Flux-Lock Type HTSC Fault Current Limiter with Hysteresis Characteristic (히스테리시스 특성을 고려한 자속구속형 고온초전도 사고전류 제한기의 사고전류 제한특성 분석)

  • Lim, Sung-Hun;Choi, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.94-98
    • /
    • 2007
  • The fault current limiting characteristics of a flux-lock type superconducting fault current limiter (SFCL) considering hysteresis characteristics of a flux-lock reactor, which is an essential component of the flux-lock type SFCL, were investigated. In the normal state, the hysteresis loss of iron core in the flux-lock type SFCL does not happen due to its winding's structure. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the hysteresis curves together with the fault current level due to the inductance ratio between the primary and the secondary windings, the increase of the number of turns in the secondary winding of the flux-lock type SFCL made the fault current level increase. On the other hand, the saturation of iron core was prevented.

SRM Driving Characteristics through Modeling of Variable Hysteresis Current Control (가변 히스테리시스 전류제어 모델링을 통한 SRM 구동특성)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.123-128
    • /
    • 2022
  • The torque of the SRM((Switched Reluctance Motor)) is proportional to the inductance slope, so it has a non-linear torque characteristic, and has a disadvantage in that the torque pulsation is large and noise is severe. In particular, the biggest obstacle to the commercialization of SRM is the pulsating torque generated from the rotating shaft, which has various adverse effects not only on the device itself but also on the peripheral devices. Therefore, various methods for reducing the pulsating torque have been published by domestic and foreign researchers, and there is a study result that the hysteresis controller has an advantage in that it can flow a smooth current compared to the chopping control. However, in determining the hysteresis band, if the band is too small, it has a disadvantage in that it may cause a switching loss due to many switching and an unstable initial start when the encoder is used. Therefore, in this paper, a variable hysteresis controller that can reduce torque ripple in a steady state while having a more stable and fast speed response through the change of the hysteresis band according to the speed error.

The hysteresis characteristic of Feedback field-effect transistors with fluctuation of gate oxide and metal gate (게이트 절연막과 게이트 전극물질의 변화에 따른 피드백 전계효과 트랜지스터의 히스테리시스 특성 확인)

  • Lee, Kyungsoo;Woo, Sola;Cho, Jinsun;Kang, Hyungu;Kim, Sangsig
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.488-490
    • /
    • 2018
  • In this study, we propose newly designed feedback field-effect transistors that utilize the positive feedback of charge carriers in single-gated silicon channels to achieve steep switching behaviors. The band diagram, I-V characterisitcs, subthreshold swing, and on/off current ratio are analyzed using a commercial device simulator. To demonstrate the changing characteristics of hysteresis, one of the important features of the feedback field effect transistor, we simulated changing the gate insulating material and the gate metal electrode. The fluctuation in the characteristics changed the $V_{TH}$ of the hysteresis and showed a decrease in width of the hysteresis.

Magnetic Tunneling Effects in $Permalloy/Al_{2}O_{3}/Co$ Junction ($Permalloy/Al_{2}O_{3}/Co$ 접합의 자기터널 효과)

  • 이민숙;송현주;장현숙;김미양;이장로;이용호
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.1
    • /
    • pp.29-33
    • /
    • 1993
  • Magnetoresistance was studied for the ferromagnetic tunneling junction in $Permalloy/Al_{2}O_{3}/Co$ prepared by evaporation in a vacuum of $1{\times}10^{-6}$Torr. We measured voltage-current characteristic and magnetic valve effect of prepared ferromagnetic tunneling junction sample. We investigated field-dependency of tunnel resistance by Wheat-stone bridge method and measured magnetic hysteresis curve by vibrating sample magnetometer. The tunneling is confirmed by measuring voltage-current characteristic. The hysteresis curve of magnetoresistance corresponds well with that of magnetization. The magnetoresistance ratio ${\Delta}R/R$ is 0.6% at room temperature.

  • PDF

Evaluating Unsaturated Hydraulic Properties of Compacted Geomaterials in Road Foundations (I) : Laboratory Test (다져진 도로기초 재료의 불포화투수특성 평가 (I) : 실내실험)

  • Park, Seong-Wan;Sung, Yeol-Jung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.73-82
    • /
    • 2011
  • Generally, an unsaturated condition was not considered to predict the long-term strength and drainage behaviors on compacted road foundations. However, it is logical way to consider the unsaturated condition and hysteresis behavior on road foundations like subbase and subgrade. For more quantitative analysis, rational experimental approach requires proper laboratory tool and material model, and hydraulic properties of pavement geomaterials under unsaturated conditions. In this study, therefore, laboratory data from the soil-water characteristic curve tests were used to predict suction and unsaturated permeability on pavement foundations and the results were analyzed based on the nonlinear fitting model considered. In addition to that, the unsaturated moisture capacity of each material is discussed.

Compensation Algorithm for the Secondary Voltage of a Coupling Capacitor Voltage Transformer by Considering the Hysteresis Characteristics of the Core (코어의 히스테리시스 특성을 고려한 CCVT 2차 전압 보상 알고리즘)

  • Kang, Yong-Cheol;Zheng, Tai-Ying;Kang, Hae-Gweon;Jang, Sung-Il;Kim, Yong-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1457-1462
    • /
    • 2009
  • This paper proposes a compensating algorithm for the secondary voltage of a coupling capacitor voltage transformer (CCVT) in the time domain by considering the hysteresis characteristics of the core. The proposed algorithm estimates the three error terms i.e. the voltage across the secondary winding parameters, the voltage across the primary winding parameters, and the voltage across the capacitor and the tuning reactor. These three terms are added to the measured secondary voltage to obtain the correct voltage. The algorithm reduces the errors of the CCVT significantly both in the steady state and during a fault. The performance of the algorithm is verified under the various fault conditions by varying the fault distance, the fault inception angle, and the fault impedance with the EMTP generated data. Test results clearly indicate that the algorithm can increase the accuracy of a CCVT significantly under the fault conditions as well as in the steady state. The algorithm helps improve the performance of a protection relay or a metering device.

Preisach model based Real-time control for systems with Hysteresis (히스테리시스를 갖는 미세 구동기의 실시간 제어 알고리즘)

  • Lee, Ah-Ram;Lee, Ji-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.1
    • /
    • pp.31-40
    • /
    • 2008
  • This paper presented the development and real-time control of a magnetostrictive micro actuator. Magnetostrictive material has many advantages such as high response time, precision displacement and powerful output force. But Magnetostrictive material has characteristic of hysteresis. Conventional Preisach model which based on experimental data is not suitable to the real-time control because of controlling a magnetostrictive system by Preisach model costs a lot of calculating time. And, we prove the validity of proposed model through the experimental comparison between the classical Preisach model and the proposed one.

A Study on the Characteristic of Remote Control Valve Using Simulation X (SimulationX를 이용한 Remote Control Valve의 특성 분석에 관한 연구)

  • Jeong, Yoo Seong;Chung, Won Jee;Lee, San Sung;Lee, Jung Min;Choi, Kyoung Shin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.78-84
    • /
    • 2017
  • Compared to other types of power, hydraulic energy is the most commonly used for heavy vehicles and ships because it has fewer location and space constraints, and its controllability can be maintained even under adverse conditions. Operators have controlled a main control valve of ship winches by pushing or pulling the lever, which is directly connected to the spool. However, because of the spatial arrangement, the importance of remote control valves has emerged. In this paper, experiments of the hysteresis characteristics were performed by analyzing the remote-control valve using a valve tester and RA2300. The validity was verified by comparing with the analytical model using SimulationX as the hydraulic analysis program. This study examined the effects of the spool's notch (Non, End-mill, and Spherical) and the effects of stiffness and pre-load of the spool spring on Spool stroke, open area, and hysteresis characteristics. It is considered possible to reduce the cost and the, trial and error process in designing remote-control valves in the future.

The Design, Fabrication, and Characteristic Experiment for Control Rod Position Indicator Using Reed Switch in System-Integrated Modular Advanced Reactor (리드스위치를 이용한 일체형원자로용 제어봉 위치지시기 설계 제작 및 특성해석)

  • Hur, Hyung;Kim, Jong-In;Kim, Kern-Jung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.452-461
    • /
    • 2003
  • The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indicator system and its actual implementation in the existing nuclear power plants in Korea was performed first. The control rod position indicator having the high performance for SMART was developed on the basis of RSPT technology identified through the survey. The arrangement of permanent magnet and reed switches is the most important procedure in the design of control rod position indicator. The hysteresis of reed switches is one of the important factors in a repeat accuracy of control rod position indicator as well. This paper investigates efficiency of the magnetic flux concentrator and the hysteresis using FEM and verified differences in physicals characteristics by comparing the results of FEM and those of the experiment. As a result, it is shown that the characteristics of prototype control rod position indicator have a good agreement with the results of FEM.