• 제목/요약/키워드: HyperGam

검색결과 6건 처리시간 0.015초

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.

Uranium Enrichment Determination Using a New Analysis Code for the U XKα Region: HyperGam-U

  • Kim, Junhyuck;Choi, Hee-Dong;Park, Jongho
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.778-784
    • /
    • 2016
  • HyperGam-U was recently developed to determine uranium enrichment based on ${\gamma}$- and X-ray spectroscopy analysis. The $XK_{\alpha}$ region of the uranium spectrum contains 13 peaks for $^{235}U$ and $^{238}U$ and is used mainly for analysis. To describe the X-ray peaks, a Lorentzian broadened shape function was used, and methods were developed to reduce the number of fitting parameters for decomposing the strongly overlapping peaks using channel-energy, energy-width, and energy-efficiency calibration functions. For validation, eight certified reference material uranium samples covering uranium enrichments from 1% to 99% were measured using a high-resolution planar high-purity germanium detector and analyzed using the HyperGam-U code. When corrections for the attenuation and true coincidence summing were performed for the detection geometry in this experiment, the goodness of fit was improved by a few percent. The enrichment bias in this study did not exceed 2% compared with the certified values for all measured samples.

NEW DEVELOPMENT OF HYPERGAM AND ITS TEST OF PERFORMANCE FOR γ-RAY SPECTRUM ANALYSIS

  • Park, B.G.;Choi, H.D.;Park, C.S.
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.781-790
    • /
    • 2012
  • The HyperGam program was developed for the analysis of complex HPGe ${\gamma}$-ray spectra. The previous version of HyperGam was mainly limited to the analysis of ${\gamma}$-ray peaks and the manual logging of the result. In this study, it is specifically developed into a tool for the isotopic analysis of spectra. The newly developed features include nuclide identification and activity determination. An algorithm for nuclide identification was developed to identify the peaks in the spectrum by considering the yield, efficiency, energy and peak area for the ${\gamma}$-ray lines emitted from the radionuclide. The detailed performance of nuclide identification and activity determination was accessed using the IAEA 2002 set of test spectra. By analyzing the test spectra, the numbers of radionuclides identified truly (true hit), falsely (false hit) or missed (misses) were counted and compared with the results from the IAEA 2002 tests. The determined activities of the radionuclides were also compared for four test spectra of several samples. The result of the performance test is promising in comparison with those of the well-known software packages for ${\gamma}$-ray spectrum analysis.

Basic characterization of uranium by high-resolution gamma spectroscopy

  • Choi, Hee-Dong;Kim, Junhyuck
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.929-936
    • /
    • 2018
  • A basic characterization of uranium samples was performed using gamma- and X-ray spectroscopy. The studied uranium samples were eight types of certified reference materials with $^{235}U$ enrichments in the range of 1-97%, and the measurements were performed over 24 h using a high-resolution and high-purity planar germanium detector. A general peak analysis of the spectrum and the $XK_{\alpha}$ region of the uranium spectra was carried out by using HyperGam and HyperGam-U, respectively. The standard reference sources were used to calibrate the spectroscopy system. To obtain the absolute detection efficiency, an effective solid angle code, EXVol, was run for each sample. Hence, the peak activities and isotopic activities were determined, and then, the total U content and $^{234}U$, $^{235}U$, and $^{238}U$ isotopic contents were determined and compared with those of the certified reference values. A new method to determine the model age based on the ratio of the activities of $^{223}Ra$ and $^{235}U$ in the sample was studied, and the model age was compared with the known true age. In summary, the present study developed a method for basic characterization of uranium samples by nondestructive gamma-ray spectrometry in 24 h and to obtain information on the sample age.

진간식풍탕(鎭肝熄風湯)이 가토(家兎)의 혈압(血壓) 및 혈청(血淸) Total Cholesterol에 미치는 영향(影響) (Effect of Chin Gan Sik Pung Tang on Blood Pressure and induced Hypercholesteremic Rabbit)

  • 김희준;임재훈
    • 대한한방내과학회지
    • /
    • 제11권1호
    • /
    • pp.109-120
    • /
    • 1990
  • In order to investigate the therapeutic effects on blood pressure and hyper cholesteremia, aqueous extract of Chin Gan Sik Pung Tang were studied. The result of the total cholesterol contents in serum and blood pressure of each group were as follows, 1. The aqueous extract of Chin Gan Sik Pung Tang inhibited increased Total cholesterol in serum of rabbits administrated with cholesterol rich diet. 2. Blood pressure manifested gradual response by the fall of 4, 3, 9.2, 19.9 percent in proportion to the administration of 10, 30, 100 mg/kg of Chin Gan Sik pung Tang, respectively 3. Administration of Chin Gan Sik Pung Tang to the rabbit pretreated with Vagotomy, Atropine and Regitine did not show any significant difference in the blood pressure, compare with that of the control group. 4. Administration of Chin Gan Sik Pung Tang to the rabbit pretreated with propranolol show significant difference in the blood pressure, compare with that of the control group. From the above results, it is suggested that Chin Gam Sik Pung Tang has the action on adrenergic ${\beta}-receptor$ and can he used therapeutic effect on the hypertension, and inhibit the increase of Total Cholesterol contents in serum.

  • PDF

ANALYSIS OF DOPPLER-BROADENED PEAK IN THERMAL NEUTRON INDUCED 10B(n,α γ)7Li REACTION USING HYPERGAM

  • Choi, Hee-Dong;Jung, Nam-Suk;Park, Byung-Gun
    • Nuclear Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.113-124
    • /
    • 2009
  • The line shape functions for the Doppler-broadened gamma ray spectrum are considered in the $^{10}B(n,{\alpha}{\gamma})^7Li$ reaction occurring in a surrounding medium where the excited $^7Li$ nucleus is slowed down and stopped before decay. The phenomenological form of the stopping power was used for the broadening effect. Convolution with the detailed response of a germanium detector is taken into consideration for the simplest case of solely electronic stopping. A numerical study for the analysis of $^{10}B$ by thermal neutron capture is conducted by performing a parametric search and fitting the measured spectrum in a least-squares approach. In comparison with the previous numerical approach using the same analysis, the computational speed is increased and reliable information concerning the stopping power of the medium is obtained while estimating the uncertainty. Implementation of the routine analysis of $^{10}B$ is facilitated on a recent version of the gamma ray spectrum analysis package HyperGam.