• Title/Summary/Keyword: Hyper-V

Search Result 69, Processing Time 0.025 seconds

Implementation of Covert Channel Using Mutex Shared Resources in Virtual Machine (가상머신 내 mutex 공유 자원을 이용한 은닉 채널 구현)

  • Ko, Ki-Wan;Choi, Hyoung-Kee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.5
    • /
    • pp.961-971
    • /
    • 2019
  • Isolation between virtual machines in a cloud computing environment is an important security factor. The violation of isolation between virtual machines leads to interferences of shared resources and the implementation of covert channels. In this paper, the structure of Hyper-V hypervisor is analyzed to implement covert channels between virtual machines. Hyper-V uses a mutex technique for mutual exclusion between virtual machines. It indicates that isolation of virtual machines is violated and covert channels can be implemented due to mutex. We implemented several covert channels by designing a method for searching mutex resources applicable to Hyper-V with complex architectures. The mutex-based covert channel is not hardware dependent. If the covert channel is detected or defended, the defensive technique can be avoided by using the other covert channel among several covert channels.

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.

Analysis of Bisection width and Fault Diameter for Hyper-Star Network HS(2n, n) (상호연결망 하이퍼-스타 HS(2n, n)의 이분할 에지수와 고장지름 분석)

  • Kim, Jong-Seok;Lee, Hyeong-Ok
    • The KIPS Transactions:PartA
    • /
    • v.12A no.6 s.96
    • /
    • pp.499-506
    • /
    • 2005
  • Recently, Hyper-Star network HS(m,k) which improves the network cost of hypercube has been proposed. In this paper, we show that the bisection width of regular Hyper-Star network HS(2n,n) is maximum (2n-2,n-1). Using the concept of container, we also show that k-wide diameter of HS(2n,n) is less than dist(u,v)+4, and the fault diameter is less than D(HS(2n,n))+2, where dist(u,v) is the shortest path length between any two nodes u and v in HS(2n,n), and D(HS(2n,n)) is its diameter.

BOUNDS ON THE HYPER-ZAGREB INDEX

  • FALAHATI-NEZHAD, FARZANEH;AZARI, MAHDIEH
    • Journal of applied mathematics & informatics
    • /
    • v.34 no.3_4
    • /
    • pp.319-330
    • /
    • 2016
  • The hyper-Zagreb index HM(G) of a simple graph G is defined as the sum of the terms (du+dv)2 over all edges uv of G, where du denotes the degree of the vertex u of G. In this paper, we present several upper and lower bounds on the hyper-Zagreb index in terms of some molecular structural parameters and relate this index to various well-known molecular descriptors.

Expanding LZW initial dictionary for the effective compression of hyper-text (LZW 알고리즘의 초기 사전 확장을 통한 효과적인 Hyper-Text 문서 압축)

  • 신광철;한상용
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04a
    • /
    • pp.688-690
    • /
    • 2002
  • LZW 알고리즘은 사전방식의 압축 알고리즘인 LZ78의 변형된 형태로써 높은 압축률을 제공하기 때문에 많은 압축 방법에서 사용되고 있다. LZW에서 사전을 이용하는 방식은 LZ78과는 달리 미리 문서에 나오는 문자들을(즉, ASCII 코드) 미리 저장해 놓고 압축을 한다. 본 논문은 Hyper-Text에서는 같은 단어가 자주 반복되는 것에 착안하여 그러한 한 단어를 코드형태로 미리 저장해 놓고 LZW알고리즘을 적용하였다. 본 논문에서 제시하는 방법의 성능을 테스트하기 위해 기존의 V.42bis에 이러한 확장된 초기사전을 적용한 후 기존의 V.42bis 및 UNIX의 compress에 비교하였다. 실험결과를 통해 기존의 V.42bis와 compress에 비해 각각 17.9%와 17.5%의 향상된 성능을 확인할 수 있다.

  • PDF

Dynamic Responses of the TRU-loaded HYPER System

  • Kim, T.K.;Oh, Se-Kee;Kim, Y.H.;Park, W.S.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.127-137
    • /
    • 2000
  • Accelerator Driven System (ADS) named HYPER(Hybrid Power Extraction Reactor) is being developed for the transmutation of nuclear waste in Korea Atomic Energy Research Institute(KAERI). The concept of the HYPER is using 1GeV proton to drive a subcritical core. HYPER system is believed to have much more stable dynamics than the critical system in terms of neutronics. However, the HYPER system is supposed to have some drawbacks for the cooling system accidents. Loss of Flow(LOF) and Loss of Heat Sink (LOHS) cause a strong damage. As results, those accidents would stop the power production in the critical system. On the other hand, the negative reactivity feedback could not stop the HYPER system because the HYPER is driven by an accelerator rather than reactivity.(omitted)

  • PDF

A Study on the Operating Characteristics by Heat Flow Analysis of HYPER Beam Window (HYPER 빔창의 열수력 해석에 의한 운전특성에 관한 연구)

  • Song, Min-Geun;Choi, Jin-Ho;Ju, Eun-Sun;Song, Tae-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.915-920
    • /
    • 2001
  • A spent fuel problem has prevented the nuclear power from claiming to be a completely clean energy source. The nuclear transmutation technology to incinerate the long lived radioactive nuclides and produce energy during the incineration process is believed to be one or the best solutions. HYPER(Hybrid Power Extraction Reactor) is the accelerator driven transmutation system which is being developed by KAERI(Korea Atomic Energy Research Institute). Some major feature of HYPER have been developed and employed. On-power fueling concepts are employed to keep system power constant with minimum variation of accelerator power. A hollow cylinder-type metal fuel is designed for the on-line refueling concept. Lead-bismuth(Pb-Bi) is adopted as a coolant and Spallation target material. HYPER is a subcritical reactor which needs an external neutron source. 1GeV proton beam is irradiated to Lead-bismuth(Pb-Bi) target inside HYPER, and spallation neutrons are produced. When proton beams are irradiated, much heat is also deposited in the Pb-Bi target and beam window which separates Pb-Bi and accelerator vacuum. Therfore, an effective cooling is needed for HYPER target. In this paper, we performed the thermal-hydraulic analysis of HYPER target using FLUENT code, and also calculated thermal and mechanical stress of the beam window using ANSYS code.

  • PDF

Fabrication and Characteristics of a Varactor Diode for UHF TV Tuner Operated within Low Tuning Voltage (저전압 UHF TV 튜너용 바렉터 다이오드의 제작 및 특성)

  • Kim, Hyun-Sik;Moon, Young-Soon;Son, Won-Ho;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.185-191
    • /
    • 2014
  • The width of depletion region in a varactor diode can be modulated by varying a reverse bias voltage. Thus, the preferred characteristics of depletion capacitance can obtained by the change in the width of depletion region so that it can select only the desirable frequencies. In this paper, the TV tuner varactor diode fabricated by hyper-abrupt profile control technique is presented. This diode can be operated within 3.3 V of driving voltage with capability of UHF band tuning. To form the hyperabrupt profile, firstly, p+ high concentration shallow junction with $0.2{\mu}m$ of junction depth and $1E+20ions/cm^3$ of surface concentration was formed using $BF_2$ implantation source. Simulation results optimized important factors such as epitaxial thickness and dose quality, diffusion time of n+ layer. To form steep hyper-abrupt profile, Formed n+ profile implanted the $PH_3$ source at Si(100) n-type epitaxial layer that has resistivity of $1.4{\Omega}cm$ and thickness of $2.4{\mu}m$ using p+ high concentration Shallow junction. Aluminum containing to 1% of Si was used as a electrode metal. Area of electrode was $30,200{\mu}m^2$. The C-V and Q-V electric characteristics were investigated by using impedance Analyzer (HP4291B). By controlling of concentration profile by n+ dosage at p+ high concentration shallow junction, the device with maximum $L_F$ at -1.5 V and 21.5~3.47 pF at 0.3~3.3 V was fabricated. We got the appropriate device in driving voltage 3.3 V having hyper-abrupt junction that profile order (m factor) is about -3/2. The deviation of capacitance by hyper-abrupt junction with C0.3 V of initial capacitance is due to the deviation of thermal process, ion implantation and diffusion. The deviation of initial capacitance at 0.3 V can be reduced by control of thermal process tolerance using RTP on wafer.

Hyper-inflammatory responses in COVID-19 and anti-inflammatory therapeutic approaches

  • Choi, Hojun;Shin, Eui-Cheol
    • BMB Reports
    • /
    • v.55 no.1
    • /
    • pp.11-19
    • /
    • 2022
  • The coronavirus disease 2019 (COVID-19) is an ongoing global pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Patients with severe COVID-19 exhibit hyper-inflammatory responses characterized by excessive activation of myeloid cells, including monocytes, macrophages, and neutrophils, and a plethora of pro-inflammatory cytokines and chemokines. Accumulating evidence also indicates that hyper-inflammation is a driving factor for severe progression of the disease, which has prompted the development of anti-inflammatory therapies for the treatment of patients with COVID-19. Corticosteroids, IL-6R inhibitors, and JAK inhibitors have demonstrated promising results in treating patients with severe disease. In addition, diverse forms of exosomes that exert anti-inflammatory functions have been tested experimentally for the treatment of COVID-19. Here, we briefly describe the immunological mechanisms of the hyper-inflammatory responses in patients with severe COVID-19. We also summarize current anti-inflammatory therapies for the treatment of severe COVID-19 and novel exosome-based therapeutics that are in experimental stages.

EXTREMAL CHEMICAL TREES WITH RESPECT TO HYPER-ZAGREB INDEX

  • Ghalavand, Ali;Ashrafi, Ali Reza;Sharafdini, Reza;Ori, Ottorino
    • The Pure and Applied Mathematics
    • /
    • v.26 no.3
    • /
    • pp.177-188
    • /
    • 2019
  • Suppose G is a molecular graph with edge set E(G). The hyper-Zagreb index of G is defined as $HM(G)={\sum}_{uv{\in}E(G)}[deg_G(u)+deg_G(v)]^2$, where $deg_G(u)$ is the degree of a vertex u in G. In this paper, all chemical trees of order $n{\geq}12$ with the first twenty smallest hyper-Zagreb index are characterized.