• 제목/요약/키워드: Hydroxyapatite coating

검색결과 98건 처리시간 0.018초

저농도 알칼리 생체유리의 물성 및 Hydroxyapatite 형성 (Physical Properties and Hydroxyapatite Formation of Low Alkali Containing Bioglass)

  • 김용수;김철영
    • 한국세라믹학회지
    • /
    • 제31권12호
    • /
    • pp.1521-1528
    • /
    • 1994
  • To improve mechanical strength of bioglass, it is considered to use the glass as a coating material to alumina, but the difference in thermal expansion coefficient between two materials is too high to make a good coating. The aim of the present study, therefore, is to find out proper glass composition matching its thermal expansion coefficient to that of alumina without losing biocompatibility. In the present work, various glasses were prepared by substituting B2O3 and CaO for Na2O in the glass system of 55.1%SiO2-2.6%P2O5-20.1%Na2O-13.3%CaO-8.9%CaF2 (in mole%), and the thermal expansion property and reaction property in tris-buffer solution for the resulting glasses were measured. The thermal expansion coefficient of the glass was decreased with the substitution of B2O3 for Na2O, and it became close to that of alumina in the glass in which 8 mole% of CaO was substituted for Na2O. Hydroxyapatite formation was enhanced and silica rich layer thickness was decreased with B2O3 substitution for Na2O. CaO substitution for Na2O didn't deteriorated the hydroxyapatite development.

  • PDF

수산화인회석 코팅 임프란트의 골치유과정에 관한 실험적 연구 (Experimental study about the bony healing of hydroxyapatite coating implants)

  • 엄태관;김종화;조인희;정창모;조용석;김영균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권4호
    • /
    • pp.295-300
    • /
    • 2011
  • Introduction: Hydroxyapatite(HA) coating implant can accelerate osseointegration, however, there are many controversies. Materials and Methods: This study examined the early osseointegration of two types of hydroxyapatite coated implants. Twelve adult male miniature pigs (Medi Kinetics Micropigs, Medi Kinetics Co., Ltd., Busan, Korea) were used in this study. In the implants placed in the mandible, a histomorphometric evaluation was performed to evaluate the bone-implant contact (BIC) ratio. Results: The BIC ratio increased with time. TS III HA and Zimmer HA were not significantly different (P>0.05). At 8 weeks, the BIC of Zimmer HA was higher than TS III HA, but there was no significant difference (P>0.05). Conclusion: HA coated implants will accelerate early osseointegration.

Biological Effects of Different Thin Layer Hydroxyapatite Coatings on Anodized Titanium

  • Sohn, Sung-Hwa;Jun, Hye-Kyoung;Kim, Chang-Su;Kim, Ki-Nam;Ryu, Yeon-Mi;Lee, Seung-Ho;Kim, Yu-Ri;Seo, Sang-Hui;Kim, Hye-Won;Shin, Sang-Wan;Ryu, Jae-Jun;Kim, Meyoung-Kon
    • Molecular & Cellular Toxicology
    • /
    • 제1권4호
    • /
    • pp.237-247
    • /
    • 2005
  • Several features of the implant surface, such as roughness, topography, and composition play a relevant role in implant integration with bone. This study was conducted in order to determine the effects of various thin layer hydroxyapatite (HA) coatings on anodized Ti surfaces on the biological responses of a human osteoblast-like cell line (MG63). MG63 cells were cultured on A (100 nm HA coating on anodized surface), B (500-700 nm HA coating on anodized surface), C ($1{\mu}m$ HA coating on anodized surface), and control (non HA coating on anodized surface) Ti. The morphology of these cells was assessed by SEM. The cDNAs prepared from the total RNAs of the MG63 were hybridized into a human cDNA microarray (1,152 elements). The appearances of the surfaces observed by SEM were different on each of the four dental substrate types. MG63 cells cultured on A, C and control exhibited cell-matrix interactions. It was B surface showing cell-cell interaction. In the expression of several genes were up-, and down-regulated on the different surfaces. The attachment and expression of key osteogenic regulatory genes were enhanced by the surface morphology of the dental materials used.

Hydrothermal Coating of Hydroxyapatite on ZrO2 Ceramics

  • Ha, Jung-Soo
    • 한국세라믹학회지
    • /
    • 제43권8호
    • /
    • pp.463-468
    • /
    • 2006
  • Hydrothermal deposition of hydroxyapatite coatings on two types of $ZrO_2$ substrates (3 mol% $Y_2O_3$-doped and 13 mol% $CeO_2$-doped tetragonal $ZrO_2s$) was studied using aqueous solutions of $Ca(NO_3)_2\;4H_2O$ and $(NH_4)_2HPO_4$ containing EDTA (ethylene diamine tetra acetic acid) disodium salt as a chelating agent for $Ca^{2+}$ ions. For the precipitation of the coatings, the $EDTA-Ca^{2+}$ chelates were decomposed by oxidation with $H_2O_2$ at $90^{\circ}C$. The deposition behavior, morphology, and orientation of the coatings were investigated while varying the solution pH using scanning electron microscopy and X-ray diffractometry. For the two sub-strates, sparse deposition of the coating was obtained at pH 5.5, whereas a uniform deposition was obtained at pH 7.1, 9.8, and 11.4 with a denser microstructure for the higher pH. The coating consisted of thin needle-like or plate-like crystals ($1-2{\mu}m$ length or diameter) at pH 7.1, but fine rod-like crystals ($1-2{\mu}m$ length, $0.1{\mu}m$ diameter) at pH 9.8 and 11.4. The coatings were $1-3{\mu}m$ thick and showed a preferred orientation of the hydroxyapatite crystals with their c axis (i.e., the elongated direction) perpendicular to the substrate surface especially for pH 9.8 and 11.4.

Chitosan/hydroxyapatite composite coatings on porous Ti6Al4V titanium implants: in vitro and in vivo studies

  • Zhang, Ting;Zhang, Xinwei;Mao, Mengyun;Li, Jiayi;Wei, Ting;Sun, Huiqiang
    • Journal of Periodontal and Implant Science
    • /
    • 제50권6호
    • /
    • pp.392-405
    • /
    • 2020
  • Purpose: Titanium implants are widely used in the treatment of dentition defects; however, due to problems such as osseointegration failure, peri-implant bone resorption, and periimplant inflammation, their application is subject to certain restrictions. The surface modification of titanium implants can improve the implant success rate and meet the needs of clinical applications. The goal of this study was to evaluate the effect of the use of porous titanium with a chitosan/hydroxyapatite coating on osseointegration. Methods: Titanium implants with a dense core and a porous outer structure were prepared using a computer-aided design model and selective laser sintering technology, with a fabricated chitosan/hydroxyapatite composite coating on their surfaces. In vivo and in vitro experiments were used to assess osteogenesis. Results: The quasi-elastic gradient and compressive strength of porous titanium implants were observed to decrease as the porosity increased. The in vitro experiments demonstrated that, the porous titanium implants had no biological toxicity; additionally, the porous structure was shown to be superior to dense titanium with regard to facilitating the adhesion and proliferation of osteoblast-like MC3T3-E1 cells. The in vivo experimental results also showed that the porous structure was beneficial, as bone tissue could grow into the pores, thereby exhibiting good osseointegration. Conclusions: Porous titanium with a chitosan/hydroxyapatite coating promoted MC3T3-E1 cell proliferation and differentiation, and also improved osseointegration in vitro. This study has meaningful implications for research into ways of improving the surface structures of implants and promoting implant osseointegration.

MC3T3-E1 osteoblast adhesion to laser induced hydroxyapatite coating on Ti alloy

  • Huang, Lu;Goddard, Samuel C.;Soundarapandian, Santhanakrishnan;Cao, Yu;Dahotre, Narendra B.;He, Wei
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권2호
    • /
    • pp.81-93
    • /
    • 2014
  • An in vitro cell study evaluating cell adhesion to hydroxyapatite (HA) coated prosthetic Ti-6Al-4V alloy via laser treatment is presented in comparison with uncoated alloy. Based on our previous in vitro biocompatibility study, which demonstrated higher cell attachment and proliferation with MC3T3-E1 preosteoblast cells, the present investigation aims to reveal the effect of laser coating Ti alloy with HA on the adhesion strength of bone-forming cells against centrifugal forces. Remaining cells on different substrates after centrifugation were visualized using fluorescent staining. Semi-quantifications on the numbers of cells were conducted based on fluorescent images, which demonstrated higher numbers of cells retained on HA laser treated substrates post centrifugation. The results indicate potential increase in the normalized maximum force required to displace cells from HA coated surfaces versus uncoated control surface. The possible mechanisms that govern the enhancing effect were discussed, including surface roughness, chemistry, wettability, and protein adsorption. The improvement in cell adhesion through laser treatment with a biomimetic coating could be useful in reducing tissue damage at the prosthetic to bone junction and minimizing the loosening of prosthetics over time.

임플랜트 표면처리가 생체활성에 미치는 영향 (EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT)

  • 이호진;송광엽;윤태호
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.

RE Magnetron Sputtering에 의해 제조된 HAp와 HAp-Ag복합코팅층의 미세조직 (Microstructures of HAp and HAp-Ag Composite Coating Layer Prepared by RS Magnetron Sputtering)

  • Lee, Hee-Jung;Oh, Ik-Hyun;Park, Sang-Shik;Lee, Byong-Taek
    • 한국세라믹학회지
    • /
    • 제41권4호
    • /
    • pp.328-333
    • /
    • 2004
  • RF magnetron sputtering법에 의해 단상의 하이드록시아파타이트와 하이드록시아파타이트은 복합코팅층을 ZrO$_2$와 Si 웨이퍼 기판에 코팅하였다. 이들 코팅층들의 두께 0.7∼1.0$\mu\textrm{m}$ 범위였으며 또한 거칠기(roughness)는 3∼4nm였다. 열처리된 HAp 코팅층은 나노크기의 결정들로 구성되어 있었으며, 반면 Ag가 함유된 복합코팅층의 경우 결정질과 비결정질이 혼재되어 있었다. 열처리 전 HAp 코팅층의 Ca/P비는 1.9였고, Ag의 함량이 증가함에 따라 비는 감소하는 경향을 나타내었다. 또한 Ag 함량이 증가함에 따라 HAp코팅층의 미소 경도는 감소하였다.

Hydroxyapatite Coating on Al2O3 by Hydrothermal Process

  • Ha, Jung-Soo
    • 한국세라믹학회지
    • /
    • 제40권12호
    • /
    • pp.1154-1158
    • /
    • 2003
  • Hydrothermal deposition of hydroxyapatite coatings on $Al_2$O$_3$ substrates was studied using aqueous solutions of Ca(NO$_3$)$_2$ㆍ4$H_2O$ and (NH$_4$)$_2$HPO$_4$ containing EDTA disodium salt as a chelating agent for $Ca^{2+}$. For the precipitation of the coatings the EDTA-Ca$^{2+}$ chelates were dissociated thermally at 20$0^{\circ}C$ or decomposed by oxidation with $H_2O$$_2$ at 9$0^{\circ}C$. Scanning electron microscopy and X-ray diffraction were used to investigate the deposition behavior and the phase of the coatings. Hydroxyapatite coatings were not deposited with the thermal dissociation method, whereas uniform deposition of the coatings (about 0.7 $\mu\textrm{m}$ thickness) was obtained with the oxidative decomposition method. The coatings consisted of fine rod-like hydroxyapatite crystals (hexagonal structure) with 60-80 nm diameters, having some preferred orientation with their length (i.e., the c axis) perpendicular to the substrate.ate.