DOI QR코드

DOI QR Code

Experimental study about the bony healing of hydroxyapatite coating implants

수산화인회석 코팅 임프란트의 골치유과정에 관한 실험적 연구

  • Eom, Tae-Gwan (Interdisciplinary Program in Biomedical, Pusan National University) ;
  • Kim, Jong-Hwa (Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, School of Dentistry, Seoul National University) ;
  • Cho, In-Hee (Implant R&D Center, OSSTEM IMPLANT Co., Ltd.) ;
  • Jeong, Chang-Mo (Pusan National University, School of Dentistry) ;
  • Cho, Yong-Seok (Apsun Dental Hospital) ;
  • Kim, Young-Kyun (Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, School of Dentistry, Seoul National University)
  • 엄태관 (부산대학교 치의학전문대학원 치의학과) ;
  • 김종화 (서울대학교 치의학대학원 분당서울대학교병원 치과 구강악안면외과) ;
  • 조인희 (오스템임프란트 연구소) ;
  • 정창모 (부산대학교 치의학전문대학원) ;
  • 조용석 (앞선치과병원) ;
  • 김영균 (서울대학교 치의학대학원 분당서울대학교병원 치과 구강악안면외과)
  • Received : 2011.03.11
  • Accepted : 2011.07.20
  • Published : 2011.08.31

Abstract

Introduction: Hydroxyapatite(HA) coating implant can accelerate osseointegration, however, there are many controversies. Materials and Methods: This study examined the early osseointegration of two types of hydroxyapatite coated implants. Twelve adult male miniature pigs (Medi Kinetics Micropigs, Medi Kinetics Co., Ltd., Busan, Korea) were used in this study. In the implants placed in the mandible, a histomorphometric evaluation was performed to evaluate the bone-implant contact (BIC) ratio. Results: The BIC ratio increased with time. TS III HA and Zimmer HA were not significantly different (P>0.05). At 8 weeks, the BIC of Zimmer HA was higher than TS III HA, but there was no significant difference (P>0.05). Conclusion: HA coated implants will accelerate early osseointegration.

Keywords

References

  1. Jeong R, Marin C, Granato R, Suzuki M, Gil JN, Granjeiro JM, et al. Early bone healing around implant surfaces treated with variations in the resorbable blasting media method. A study in rabbits. Med Oral Patol Oral Cir Bucal 2010;15(1):e119-25.
  2. Abdel-Haq J, Karabuda CZ, Arısan V, Mutlu Z, Kurkcu M. Osseointegration and stability of a modified sand-blasted acidetched implant: an experimental pilot study in sheep. Clin Oral Implants 2011;22:265-74. https://doi.org/10.1111/j.1600-0501.2010.01990.x
  3. Zhu X, Ong JL, Kim S, Kim K. Surface characteristics and structure of anodic oxide films containing Ca and P on a titanium implant material. J Biomed Mater Res 2002;60:333-8. https://doi.org/10.1002/jbm.10105
  4. Whitehead RY, Lucas LC, Lacefield WR. The effect of dissolution on plasma sprayed hydroxylapatite coatings on titanium. Clin Mater 1993;12:31-9. https://doi.org/10.1016/0267-6605(93)90025-3
  5. Wheeler SL. Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants. Int J Oral Maxillofac Implants 1996;11:340-50.
  6. Trisi P, Keith DJ, Rocco S. Human histologic and histomorphometric analyses of hydroxyapatite-coated implants after 10 years of unction: a case report. Int J Oral Maxillofac Implants 2005;20:124-30.
  7. McGlumphy EA, Peterson LJ, Larsen PE, Jeffcoat MK. Prospective study of 429 hydroxyapatite-coated cylindric omniloc implants placed in 121 patients. Int J Oral Maxillofac Implants 2003;18:82-92.
  8. Lee JJ, Rouhfar L, Beirne OR. Survival of hydroxyapatite-coated implants: a meta-analytic review. J Oral Maxillofac Surg 2000;58:1372-9. https://doi.org/10.1053/joms.2000.18269
  9. Morris HF, Ochi S. Hydroxyapatite-coated implants: a case for their use. J Oral Maxillofac Surg 1998;56:1303-11. https://doi.org/10.1016/S0278-2391(98)90615-2
  10. Chang YL, Lew D, Park JB, Keller JC. Biomechanical and morphometric analysis of hydroxyapatite-coated implants with varying crystallinity. J Oral Maxillofac Surg. 1999;57:1096-108. https://doi.org/10.1016/S0278-2391(99)90333-6
  11. Kim H, Choi SH, Chung SM, Li LH, Lee IS. Enhanced bone forming ability of SLA-treated Ti coated with a calcium phosphate thin film formed by e-beam evaporation. Biomed Mater 2010;5:044106. https://doi.org/10.1088/1748-6041/5/4/044106
  12. Rohner D, Tay A, Chung SM, Hutmacher DW. Interface of unloaded titanium implants in the iliac crest, fibula, and scapula: a histomorphometric and biomechanical study in the pig. Int J Oral Maxillofac Implants 2004;19:52-8.
  13. Choi JY, Jung UW, Lee IS, Kim CS, Lee YK, Choi SH. Resolution of surgically created three-wall intrabony defects in implants using three different biomaterials: an in vivo study. Clin Oral Implants Res 2011;22:343-8. https://doi.org/10.1111/j.1600-0501.2010.01978.x
  14. Thierer T, Davliakos JP, Keith JD Jr, Sanders JJ, Tarnow DP, Rivers JA. Five-year prospective clinical evaluation of highly crystalline HA MP-1-coated dental implants. J Oral Implantol 2008;34:39-46. https://doi.org/10.1563/1548-1336(2008)34[39:FPCEOH]2.0.CO;2
  15. Artzi Z, Carmeli G, Kozlovsky A. A distinguishable observation between survival and success rate outcome of hydroxyapatite-coated implants in 5-10 years in function. Clin Oral Implants Res 2006;17:85-93. https://doi.org/10.1111/j.1600-0501.2005.01178.x
  16. Osstem Implant Co. TS III HA implant system clinical monitoring, 2010;1-36. Busan.
  17. Cook SD, Key JF, Thomas KA, Jarcho M. Interface mechanics and histology of titanium and hydroxylapatite-coated titanium for dental implant applications. Int J Oral Maxillofac Implants 1987;2:15-22.
  18. Block MS, Kent JN, Kay JF. Evaluation of hydroxylapatite-coated titanium dental implants in dogs. J Oral Maxillofac Surg 1987;45:601-7. https://doi.org/10.1016/0278-2391(87)90270-9
  19. Baker D, London RM, O'Neal R. Rate of pull-out strength gain of dual-etched titanium implants: a comparative study in rabbits. Int J Oral Maxillofac Implants 1999;14:722-8.
  20. Friberg B, Sennerby L, Linden B, Grondahl K, Lekholm U. Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg 1999;28:266-72. https://doi.org/10.1016/S0901-5027(99)80156-8
  21. Noguerol B, Munoz R, Mesa F, de Dios Luna J, O'Valle F. Early implant failure. Prognostic capacity of Periotest: retrospective study of a large sample. Clin Oral Implants Res 2006;17:459-64. https://doi.org/10.1111/j.1600-0501.2006.01250.x
  22. Masuda T, Yliheikkila PK, Felton DA, Cooper LF. Generalizations regarding the process and phenomenon of osseointegration. Part I. In vivo studies. Int J Oral Maxillofac Implants 1998;13:17-29.
  23. Nkenke E, Fenner M, Vairaktaris EG, Neukam FW, Radespiel-Troger M. Immediate versus delayed loading of dental implants in the maxillae of minipigs. Part II: histomorphometric analysis. Int J Oral Maxillofac Implants 2005;20:540-6.