• Title/Summary/Keyword: Hydroxyapatite coated implant

Search Result 59, Processing Time 0.021 seconds

Experimental Study of Osseointegration and Stability of Intentionally Exposed Hydroxyapatite Coating Implants (의도적으로 연조직에 노출시킨 수산화인회석 코팅 임플란트의 골유착과 안정성에 대한 실험적 연구)

  • Jeong, Kyung-In;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Jo, Ji-Ho;Lim, Hyoung-Sup;Kim, Jeong-Sun;Lim, Sung-Chul;Jeong, Mi-Ae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose: The purpose of this study is to evaluate the effect of exposure of hydroxyapatite coating on the amount of bone formation and stability in the dogs. Methods: In this study, hydroxyapatite coated implants (HAPTITE) was placed over the femur bone surface of four dogs about 1 mm. The experimental group was divided into 4 weeks group of 8 implants and 8 weeks group of 8 implants, and then they were sacrificed. The stability of implants was evaluated twice with Osstell$^{TM}$ mentor (Osstell AB, Goteborg, Sweden) at right after placement and sacrifice. The amount of bone formation was evaluated through histomorphometric examination. Results: The stability of implants was in normal range, and tended to increase as time goes by. Mean percentages of new bone formation rates were $90.5{\pm}6.6$ at uppermost 1 mm bone level adjacent to soft tissues (level 1) and $92.9{\pm}4.1$ at next 1 mm bone level (level 2) in 4 weeks group, $90.1{\pm}11.5$ at level 1 and $95.9{\pm}2.3$ at level 2 in 8 weeks group. Mean percentages of bone-implant contact rates were $85.1{\pm}10.8$ at level 1 and $88.1{\pm}13.8$ at level 2 in 4 weeks group, $88.5{\pm}14.4$ at level 1 and $95.3{\pm}3.1$ at level 2 in 8 weeks group. There was no statistically significant difference of new bone formation rate and bone-implant contact rate between uppermost 1 mm bone level adjacent to soft tissues and next 1 mm bone level. However, there was no significant difference in bone formation between 4 and 8 weeks groups. Conclusion: These results suggested that exposed hydroxyapatite coated implants to soft tissue showed favorable bone formation and implant stability.

A study of hydroxyapatite coating on Ti-6Al-4V dental implant alloy with different surface treatments using a sol-gel derived precursor (Sol-Gel 성형체에 의해 다르게 표면 처리된 치과 Implant용 Ti-6Al-4V합금의 Hydroxyapatite 코팅에 관한 연구)

  • Han, Sok-Yoon
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.139-144
    • /
    • 2004
  • In the present study, a simple method was successfully used for hydroxyapatite coatings on Ti-6Al-4V substrates deposited by using a sol-gel derived precursor. Prior to hydroxyapatite coating the samples were micropolished (0.1 micron) and divided into three sets. The first set,were the micropolished samples kept as such. The second set were coated with titania sol and the third set was treated with 5M NaOH. After three repetitions of hydroxyapatite coating procedures on each set and heat treatment at 600 $^{\circ}\Delta C$, the formation of hydroxyapatite has been confirmed by XRD analyses and the substrate material was found to be oxidized with negligible amount of CaO in the coating. The SEM studies revealed surface morphology. Hydroxyapatite, calcined at 600$^{\circ}\Delta C$, displaying a porous structure arisen from heating of the bulk. But, it is very meaningful in trying to approach morale management plans with an object of dental technicians. It is necessary that dental technicians should make efforts to control themselves.

  • PDF

Surface characteristics of a novel hydroxyapatite-coated dental implant

  • Jung, Ui-Won;Hwang, Ji-Wan;Choi, Da-Yae;Hu, Kyung-Seok;Kwon, Mi-Kyung;Choi, Seong-Ho;Kim, Hee-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.59-63
    • /
    • 2012
  • Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe's test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total, seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer's instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.

A review of biocompatibility of zirconia and bioactivity as a zirconia implant: In vivo experiment (지르코니아의 생체적합성과 임플란트로서의 생체활성에 대한 연구: In vivo 실험 문헌 고찰)

  • Suh, Da-Won;Kim, Young-Kyun;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.88-94
    • /
    • 2019
  • Increasing demands for esthetic dental treatment, zirconia, which has high mechanical and esthetic properties, had been applied more and more in clinics. Therefore, assessment of biocompatibility of zirconia is necessary. In this article, a review of in vivo studies of zirconia compatibility was performed. In vivo studies showed zirconia had great biocompatibility both on soft and hard tissue. Studies with various animals and patients reported high biocompatibility of zirconia. In terms of bone synthesis and bone adhesion, zirconia showed similar biocompatible properties to titanium. On the other hand, zirconia could be used as implant. For using as an implant, various methods of Hydroxyapatite (HA) coating had been suggested. Since HA coating on titanium implant showed some problems such as low bonding strength and degeneration of HA, HA-zirconia composite, HA-coated zirconia, and HA-zirconia functionally graded material (FGM) or intermediate layer of alumina had been proposed. These methods showed higher bonding strength and biocompatibility.

Effect of Titanium Coating on Cell Adhesion and Extracellular Matrix Formation in Human Osteoblast-like MG-63 Cells

  • Lee, Jae-Bum;Seo, Sang-Hui;Kim, Yu-Ri;Shin, Sang-Wan;Kim, Meyoung-Kon;Ryu, Jae-Jun
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.3
    • /
    • pp.192-198
    • /
    • 2008
  • A variety of titanium (Ti) and its alloys are used in the clinical procedures of bone regeneration for periodontal and dental implant therapies. This study was performed to determine the effect of different surface dental implant materials on biologic responses of a MG-63 human osteoblast-like cell line. MG-63 cells were cultured on Ti coated with hydroxyapatite (HA), calcium metaphosphate (CMP), anodized (A), which compared with non-coated Ti (control). The appearances of surface of dental implant materials and the morphology of these cells were assessed by scanning electron microscopy (SEM). The gene expression profiles of MG-63 cells cultured on Ti were examined by human cDNA microarray (1,152 elements). The expression of several genes was up- and down-regulated by different surfaces of dental implant materials. Interesting, the genes correlated with cellular adhesion and extra cellular matrix (ECM) formation were enhanced, in accordance surface morphology of the dental implant materials used.

Effect of loading time on marginal bone loss around hydroxyapatite-coated implants

  • Kim, Young-Kyun;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Minkyoung;Yang, Hong-So;Yi, Yang-Jin;Bae, Ji-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.161-167
    • /
    • 2013
  • Objectives: The objective of this study is compare the rate of marginal bone resorption around hydroxyapatite-coated implants given different loading times in order to evaluate their stability. Materials and Methods: The study was conducted retrospectively for one year, targeting 41 patients whose treatment areas were the posterior maxilla and the mandible. Osstem TS III HA (Osstem Implant Co., Busan, Korea) and Zimmer TSV-HA (Zimmer Dental, Carlsbad, CA, USA), which employ the new hydroxyapatite coating technique, were used. The patients were divided into two groups - immediate and delayed loading - and the bone level at the time of loading commencement and after one year of loading was measured using periapical radiography. Differences between the groups were evaluated using Mann-Whitney (${\alpha}$=0.05). Results: For all patients as a single group, the survival rate of the implants was 100%, and the mean marginal bone loss was $0.26{\pm}0.59mm$. In comparison of the differences by loading, mean marginal bone loss of $0.32{\pm}0.69mm$ was recorded for the immediate loading group whereas the delayed loading group had mean marginal bone loss of $0.16{\pm}0.42mm$. However, the difference was not significant (P>0.05). Conclusion: Within the limited observation period of one year, predictable survival rates can be expected when using immediately loaded hydroxyapatite-coated implants.

EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT (임플랜트 표면처리가 생체활성에 미치는 영향)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Yoon, Tae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.

Healing of the Bone around Hydroxyapatite-Coated Implants without Primary Bone Contact (초기 골 접촉이 없는 수산화 인회석 피복 임프란트 주위 골의 치유)

  • Cho, Hyung-Soo;Shin, Kwang-Yong;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.2
    • /
    • pp.415-433
    • /
    • 1999
  • Implant stability is the key to long-term successful outcome for osseointegrated implants. To evaluate the initial healing response of bone around HA-coated implants without primary bone contact. 21 HA-coated thread type implants(STERI-OSS?) were placed in the femurs of 5 mongrel dogs, about 1-year old. Implants, 8 mm in length and 3.8mm(experimental 1group), 5.0mm(experimental 2group) and 6.0mm(control group) in diameter, were inserted after 3 holes of 6.0mm in diameter and 10mm in depth were prepared in the surgical sites each dog. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), in order to prevent the ingrowth of upper soft tissue into the gap between bone and implant, and to maintain each implant to be positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 implants were inserted in 2 dogs for mobility test and removal torque test. Fluorescent dyes were injected for the observation of new bone formation in order of $Terramycin^{(R)}$, Arizarin $Red^{(R)}$, and $Calcein^{(R)}$ at an interval of 2 weeks. 3 dogs were sacrificed for histologic observation at 4, 8, and 12-week after placement. Light microscopy and confocal laser scanning microscopy were used to qualitatively characterize the bone around HA-coated implant. 2 dogs were sacrificed for mobility test($Periotest^{(R)}$, Simens AG, Bensheim, Germany) and removal torque test($Autograph^{(R)}$ AGS-1000D series, Japan) at 8 and 12-week after placement The results were as follows: 1. Histologic observation showed that osseointegration occurred to both control and experimental groups as time lapse, but delayed bone healing was revealed in 3.8mm group (experimental 1group), compared to contrtol group and 5.0mm group (experimental 2group). 2. The mobility test showed that the experimental groups had no distinguishable movement during experimental periods of 8 and 12-week, and there was no difference in mobility depending on the gap between bone and implant, and time lapse. 3. The removal torque forces were increased depended on the gaps decreasing between bone and implant, and time lapse. The results suggest that HA-coated implant without primary bone contact, based on guided bone regeneration could obtain its stability in all experimental groups as time lapse, but bone healing was delayed in experimental group of 3.8mm. And the results suggested that studies on correlationship between mobility test and removal torque test for implant stability would be necessary.

  • PDF

The effects of Hydroxyapatite nano-coating implants on healing of surgically created circumferential gap in dogs

  • Chae, Gyung-Joon;Lim, Hyun-Chang;Choi, Jung-Yoo;Chung, Sung-Min;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.373-384
    • /
    • 2008
  • Purpose: The aim of this study is to compare the healing response of various Hydroxyapatite(HA) coated dental implants by Ion-Beam Assisted Deposition(IBAD) placed in the surgically created circumferential gap in dogs. Materials and methods: In four mongrel dogs, all mandibular premolars and the first molar were extracted. After an 8 weeks healing period, six submerged type implants were placed and the circumferential cylindrical 2mm coronal defects around the implants were made surgically with customized step drills. Groups were divided into six groups : anodized surface, anodized surface with 150nm HA and heat treatment, anodized surface with 300nm HA and heat treatment, anodized surface with 150nm HA and no heat treatment, and anodized surface with 150nm HA, heat treatment and bone graft, anodized surface with bone graft. The dogs were sacrificed following 12 weeks healing period. Specimens were analyzed histologically and histomorphometrically. Results: During the healing period, healing was uneventful and implants were well maintained. Anodized surface with HA coating and $430^{\circ}C$ heat treatment showed an improved regenerative characteristics. Most of the gaps were filled with newly regenerated bone. The implant surface was covered with bone layer as base for intensive bone formation and remodeling. In case that graft the alloplastic material to the gaps, most of the coronal gaps were filled with newly formed bone and remaining graft particles. The bone-implant contact and bone density parameters showed similar results with the histological findings. The bone graft group presented the best bone-implant contact value which had statistical significance. Conclusion: Within the scope of this study, nano-scale HA coated dental implants appeared to have significant effect on the development of new bone formation. And additional bone graft is an effective method in overcoming the gaps around the implants.

EFFECTS OF THE ION BEAM ASSISTED DEPOSITION OF HYDROXYAPATITE ON OSSEOINTEGRATION OF THE ENDOSSEOUS IMPLANTS IN RABBIT TIBIAE (이온빔 보조 전자빔 수산화 인회석 증착이 골내 임플란트의 골유착에 미치는 영향)

  • Jung, Young-Chul;Han, Chong-Hyun;Lee, In-Seop;Lee, Hyeon-Jeong;Kim, Myeong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.659-674
    • /
    • 2000
  • A large increase in the use of thin film coating of hydroxyapatite(HA) in implant dentistry is driven by the desire to take advantage of the excellent biocompatibility and high strength of HA coating. The purpose of this study was to evaluate the effects of HA-coated implants by ion Beam Assisted Deposition(IBAD) method in comparison to the sand-blasted and machined surfaces. Osteoblast culture test, removal torque test and histomorphometric analysis were performed and the following results obtained; 1. Examination of the osteoblast cultures displayed no difference in the secretion of alkaline phosphatase between the various specimen, but IBAD with pure HA specimen showed low alkaline phosphatase secretion(p<0.05). 2. Removal torque tests showed HA-coated implants by IBAD method to be similar in high value to the implants with sand-blasted surface than the implants with machined surface. And the ovariectomized group showed low mechanical test value than the normal group(p<0.05). 3. Histomorphometrical comparisons were performed on undecalcified ground sections. HA-coated implants by IBAD method demonstrated the highest mean bone-to-metal contact ratio on all threads and 3-best consecutive threads, and the implants with sand-blasted surface and implants with machined surface was in the next consecutive order(p<0.05). HA-coated implants showed slightly higher bone-to- metal contact ratio than sand-blasted implants, but no statistically significant difference was obtained between the two materials. The ovariectomized group showed lower value of bone-to-metal contact ratio than the normal group, but no statistically significant difference was obtained between the two groups. 4. Evaluation of bone volume on all threads and 3-best consecutive threads showed no statistically significant difference among the different surface treatment groups, but showed lower bone volume in ovariectomized group than in the normal group(p<0.05). According tn these results, thin film coated implants with HA showed high bone contact ratio, bone volume and removal torque strength in the short term, but long term observation is needed.

  • PDF