• 제목/요약/키워드: Hydrothermal model

검색결과 95건 처리시간 0.024초

각형 출입구를 갖는 방호터널의 방폭밸브에 미치는 폭압 평가 (Blast Overpressure Evaluation for Blast Valves in Protective Tunnels with Rectangular-Shaped Tunnel Entrances)

  • 방승기;신진원
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.79-90
    • /
    • 2021
  • This paper presents a study to reduce the effect of blast pressure on the blast valves installed in protection tunnels, where the shape of the tunnel entrance and the blast pocket is optimized based on the predetermined basic shape of the protective tunnels. The reliability of the numerical tunnel models was examined by performing analyses of mesh convergence and overpressure stability and with comparison to the data in blast-load design charts in UFC 3-340-02 (DoD, 2008). An optimal mesh size and a stabilized distance of overpressure were proposed, and the numerical results were validated based on the UFC data. A parametric study to reduce the blast overpressures in tunnel was conducted using the validated numerical model. Analysis was performed applying 1) the entrance slope of 90, 75, 60, and 45 degrees, 2) two blast pockets with the depth 0.5, 1.0, and 1.5 times the tunnel width, 3) the three types of curved back walls of the blast pockets, and 4) two types of the upper and lower surfaces of the blast pockets to the reference tunnel model. An optimal solution by combining the analysis results of the tunnel entrance shape, the depth of the blast pockets, and the upper and lower parts of the blast pockets was provided in comparison to the reference tunnel model. The blast overpressures using the proposed tunnel shape have been reduced effectively.

ISO 성능데이터를 이용한 지열히트펌프 시스템의 성능 확인 커미셔닝 기술 (ISO performance data based commissioning technique for GSHP system)

  • 고건혁;김지영;강은철;장기창;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제4권2호
    • /
    • pp.1-7
    • /
    • 2008
  • GSHP(Ground Source Heat Pump) has been extensively disseminated due to the recent increasing demand over new and renewable energy. However, the system reliability has been key issues and barriers to insure a better system performance as designed originally in ISO (international standard organization) standard. This paper introduces a systematic method to verify its intended design target so called as ISO performance data based commissioning technology for a water to air GSHP system. The commissioning technology starts from are to the international standard ISO performance data of a GSHP model and to compare its installed operation data and to calibrate and tune to the target optimum operation parameters. Results indicated that cooling capacity could be raised up to 76.6% from 46.6% from this proposed commissioning technology.

  • PDF

Hydrothermal Acid Pretreatment of Chlamydomonas reinhardtii Biomass for Ethanol Production

  • Nguyen, Minh Thu;Choi, Seung-Phill;Lee, Jin-Won;Lee, Jae-Hwa;Sim, Sang-Jun
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권2호
    • /
    • pp.161-166
    • /
    • 2009
  • Certain microalgae have been known to use light and various carbon sources to produce carbohydrates, mainly in the form of starch. This is one of the pertinent feedstocks replacing agricultural products for the production of bioethanol by yeast. This study focuses upon dilute acid hydrothermal pretreatments at low cost and high efficiency to compete with current methods, and employs Chlamydomonas reinhardtii UTEX 90 as the feedstock. With dry cells of 5%(w/v), the algal biomass was pretreated with sulfuric acid(1-5%) under temperatures from 100 to $120^{\circ}C$, from 15 to 120 min. As a result, the glucose release from the biomass was maximum at 58%(w/w) after pretreatment with 3% sulfuric acid at $110^{\circ}C$ for 30 min. This method enabled not only starch, but also the hydrolysis of other oligosaccharides in the algal cell in high efficiency. Arrhenius-type of model equation enabled extrapolation of some yields of glucose beyond this range. The pretreated slurry was fermented by yeast, Saccharomyces cerevisiae S288C, resulting in an ethanol yield of 29.2% from algal biomass. This study suggests that the pretreated algal biomass is a suitable feedstock for ethanol production and can have a positive impact on large-scale applied systems.

코어 위치와 종횡비 및 방위에 따른 건물 에너지 부하 분석 (An Analysis on Building Energy Load along Core Position, Area Ratio and Orientation)

  • 김진호;박우평;신승호;민준기;김동훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권1호
    • /
    • pp.15-19
    • /
    • 2013
  • In this Study, effect of core position, area ratio and orientation of building on energy load is examined using TRNSYS17. This parameters are major parameters of the conceptual design stage. Reference model is square floor plan($1,444m^2$), centered core and 29% core area ratio. As the results, without considering the building orientation, the annual heating load of central building with 1:1 area ratio is lowest ($10.33kWh/m^2yr$) and the annual cooling load of off-central building with 1:1 area ratio is lowest ($59.27kWh/m^2yr$). As area ratio is bigger, cooling load is lower and heating load is higher. But if we consider building orientation, orders of heating load and cooling load are changed for area ratio and orientation.

$Co(OH)_2$로부터 수열법에 의한 코발트 분말제조 (Hydrothermal Reduction of $\Co(OH)_2$ to Cobalt Powder Preparation)

  • 김동진;정헌생
    • 한국재료학회지
    • /
    • 제9권7호
    • /
    • pp.675-679
    • /
    • 1999
  • $PdCl_2$를 촉매제로 사용한 수소환원분위기에서 $Co(OH)_2$ 로부터 약 400nm크기인 구형의 코발트분말 제조에 관한 연구를 수행하였다. 본 실험에서 코발트의 환원반응속도는 표면반응 코어모델식에 잘 일치하였으며 이때 활성화 에너지는 $145~195^{\circ}C$에서 약 55.6KJ/mol 이었다. 또한 코발트의 환원속도는 초기 수소분압의 0.63승에 비례하는 가스화학흡착반응식으로 표시할 수 있다.

  • PDF

이산화탄소 냉매를 이용한 냉동탑차용 핀-관 증발기의 서리성장에 따른 열교환기 성능에 관한 해석적 연구 (Theoretical Study on Heat Exchanger Performance of a Fin-tube Evaporator with Frost Growth in a $CO_2$ Refrigerator Truck)

  • 명치욱;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.48-54
    • /
    • 2012
  • To analyze the cooling performance of fin-tube evaporator in the refrigerator truck using R744 according to frost growth, the analytical model of evaporator was developed under frost and non-frost conditions. The performance of fin-tube evaporator was investigated with frost thickness and indoor temperature. Besides, the performance of evaporator under frost condition was compared to that under non-frost condition. As a result, area of air passage and system performance were decreased as the frost thickness increased. The cooling capacity was reduced by 10%, 20%, 30% when the frost thickness was 0.7 mm, 1.1 mm, and 1.6 mm respectively. At these conditions, the block ratio was 31%, 48%, and 71%. In addition, the outlet quality of refrigerant was not over 1 when the frost thickness was 1.6 mm in spite of high indoor air temperature.

고층빌딩의 층별 에너지 사용량 비교에 관한 연구 (Study of Comparison on Energy Consumption Based on HVAC area along Floor in High Rise Building)

  • 박우평;최병정;김진호
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.1-6
    • /
    • 2018
  • In this study, the energy consumption of the typical floor was compared by the total energy comsumption of the building in highrise building. In gerneral, many researchers are studying on the typical floor in highrise buildings for avoiding complexity in energy simulation. But few papers are studied on energy consumption along the floors. In the model bulding, the energy consumption data were acquired by BEMS system in 2011. According the data, the total net energy consumption was $193.99kWh/m^2$ for all area and the total net energy consumption was $247.61kWh/m^2$ for HVACR area. The total electricity and gas energy are used 47.7% for heating and cooling, 33.5% for lighting and plug, 12.9% for conveyance power and 5.9% for restaurant. In comparison of only ground floor, amount of energy consumption in the lobby is 10%, and 90% of total energy consumption is used in the typical floor. For this result, energy simulation on the typical floor is acceptable for calculating the total energy consumption in the highrise building.

폐열이용 열펌프시스템의 성능에 관한 연구 (Performance Analysis on a Heat Pump System using Waste Heat)

  • 박윤철;송뢰;고광수
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.53-60
    • /
    • 2018
  • This study was conducted for analysis of a heat pump system using waste heat in an enclosed space such as a green house. The model was developed with mathematical equations in literature and Engineering Equation Solver (EES) was used to get the solution of the developed equations. The simulation results have 5% of reliability comparing the results with actual test data of heat pump system's dynamic operation. The operating performance of the system was calculated with variation of working fluid temperature in the thermal storage tank such as $25^{\circ}C$, $35^{\circ}C$, $45^{\circ}C$ and $55^{\circ}C$. As a result, the system's the highest total heating capacity shows 280 kWh and the storage tank's operating time decreased as the starting storage tank's temperature was high.

리튬이온전지 열폭주에 대해 양극활물질이 미치는 영향에 대한 수치해석적 연구 (Numerical analysis on thermal runaway by cathode active materials in lithium-ion batteries)

  • 강명보;김남진
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.1-10
    • /
    • 2021
  • Lithium-ion batteries with high energy density, long cycle life and other advantages, have been widely used to energy storage systems(ESS). But as ESS fires frequently occur, the safety concern has become the main obstacle that hinders the large-scale applications of lithium-ion batteries. Especially, thermal runaway is the key scientific problem in battery safety research. Therefore, in this study, we performed a numerical analysis on the thermal runaway phenomenon of NCM111, NCM523 and NCM622 batteries using a two-dimensional analysis model. The results show that the two-dimensional simulation results are generally matched with three-dimensional simulation. Also, In the case of NCM111 with a low Ni content in the temperature range used in this study, thermal runaway phenomenon does occurred very slowly, but as the Ni content is increased, the thermal runaway phenomenon occurs rapidly and the thermal stability tends to be decreased. And, in NCM523 and NCM622 batteries, chain reactions occur almost simultaneously, but in the case of NCM111 battery, it is found that after the SEI(Solid Electrolyte Interface) layer decomposition reaction, the cathode-electrolyte reaction is appeared sequentially. After that, the anodic decomposition reaction is increased and leads to the thermal runaway reaction.

지중온도회복을 고려한 지열 히트펌프 시스템의 운전방법 검토 (Study on the Operation Method of Ground Source Heat Pump System Considering Recovery of Ground Temperature)

  • 배상무;전재영;권영식;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.24-30
    • /
    • 2020
  • Ground source heat pump (GSHP) systems are actively introduced as cooling and heating conditioning systems of buildings due to annual stable performance and easily maintenance. However, ground temperature imbalance is occurred when the GSHP is used for a long period. Therefore, in this study, we proposed the operation method of the system that considered the recovery time of heat source temperature. The entering water temperature (EWT) and heat exchange rate (HER) were comparatively analyzed according to the continuous and intermittent operation. Furthermore, the underground thermal environment was evaluated by numerical analysis model. As the result, the intermittent operation was a maximum of 12.3% higher HER during the heating period than the continuous operation. In addition, the overall ground heat source temperature at the intermittent operation was higher than it at the continuous operation.