하수처리시설의 에너지자립화 및 경제적 효과분석 (Study on Energy Independence Plan and Economic Effects for Sewage Treatment Plant)

  • 박기학;이호식;하준수;김극태;임채승
    • 한국물환경학회지
    • /
    • 제37권2호
    • /
    • pp.128-136
    • /
    • 2021
  • It is generally known that a wastewater treatment plant (WWTP) consumes immense energy even if it can produce energy. With an aim to increase the energy independence rate of WWTP from 3.5% in 2010 to 50% in 2030, the Korean government has invested enormous research funds. In this study, cost-effective operating alternatives were investigated by analyzing the energy efficiency and economic feasibility for biogas and power generation using new and renewable energy. Based on the US EPA Energy Conservation Measures and Korea ESCO projects, energy production and independence rate were also analyzed. The main energy consumption equipment in WWTP is the blower for aeration, discharge pump for effluent, and pump for influent. Considering the processes of WWTP, the specific energy consumption rate of the process using media and MBR was the lowest (0.549 kWh/㎥) and the highest (1.427 kWh/㎥), respectively. Energy-saving by enhancing anaerobic digester efficiency was turned out to be efficient when in conjunction with stable wastewater treatment. The result of economic analysis (B/C ratio) was 2.5 for digestive gas power generation, 0.86 for small hydropower, 0.49 for solar energy, and 0.15 for wind energy, respectively. Furthermore, it was observed that the energy independence rate could be enhanced by installing energy production facilities such as solar and small hydropower and reducing energy consumption via the replacement of high-efficiency operating.

수력발전소 가이드 베인 저개도율 운전에 따른 가이드 베인 베어링 부슁의 마모 가속효과 평가 (Evaluation of Effect of Low Opening Operation on Increasing Wear of Bearing Bushings of Guide Vanes used in Hydropower Plants)

  • 김종성;김세나
    • 대한기계학회논문집A
    • /
    • 제36권10호
    • /
    • pp.1267-1274
    • /
    • 2012
  • 가이드 베인은 수력발전소 수차에 공급되는 물량을 제어하는 핵심적인 역할을 수행한다. 가이드 베인 베어링 부슁에 발생하는 마모와 관련하여 많은 정비 사례들이 보고되고 있다. 수력발전소의 중요기능인 주파수 조정, 급전 등과 같은 부수적 서비스는 가이드 베인을 작게 열고 운전하는 저개도율 운전을 반복적으로 수행하게 한다. 이러한 저개도율 운전은 가이드 베인 베어링 부슁의 마모율을 증가시키는 것으로 경험적으로 알려져 있다. 본 연구에서는 수력발전소의 가이드 베인 저개도율 운전이 가이드 베인 베어링 부슁의 마모를 가속시키는 효과를 유한요소 유동/응력 해석 및 상대적인 마모 평가를 통해 정량적으로 평가한다. 평가 결과, 가이드 베인 개도율이 작을수록 가이드 베인면에 작용하는 압력이 증가하고 가이드 베인 스템 외면과 베어링 부슁 내면 사이의 접촉길이는 감소하였으며 베어링 부슁 표면에 작용하는 접촉압력이 크게 발생하여 상대적으로 마모량이 증가함을 확인하였다.

해외 노후 수력발전시스템 수용가 맞춤형 현대화 기술개발 및 실증 (Development of modernizing Old Small-Hydropower system with custom-built at Overseas)

  • 김운학;강석원;신기석
    • 한국재난정보학회 논문집
    • /
    • 제14권2호
    • /
    • pp.174-181
    • /
    • 2018
  • 연구목적: 본 연구는 운용중인 해외 노후 수력발전 시스템 수용가 맞춤형 현대화 기술개발 및 실증이 그 목적이다. 연구방법: 현지에서 운용중인 발전소의 일간, 주간, 윌간, 년간 정보를 바탕으로 현대화 설계를 수행 하였다. 연구결과: 본 논문에서는 국내 시설물 안전관리에 관한 특별법에 의거 필리핀에 위치한 노후 수력발전소의 현대화를 위해 최초 기존 시설물에 대한 안전진단을 실시하여 토목 및 건축물의 보강을 위한 방법을 선정하였다. 결론: 현지 환경에 적합한 수차선정과 노후 시설물의 유지보수를 국내 토목 보수 보강 기술로 설계하였다.

Theory and Practices of Water Pollution Control by Wetland - a Case Study of Reed Wetland in Baiyangdian Lake

  • Li, Guibao;Zhou, Huaidong;Liu, Fang;Wang, Dianwu
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.72-76
    • /
    • 2004
  • Wetland is an important eco-system on the earth and can effectively control agricultural non-point source pollution. Reed is a typical wetland plant for land/inland water ecotone in north China. The studies indicated that reed had a underground rooted-stem, which formed a 'high speeded-connecting vessels' i.e. reed root channel (RRC) in Baiyangdian lake of Hebei province. It spread predominantly along horizontal direction underground and are mainly distributed at 18-75 cm. The results of field work from healthy reed-wetland (HRW) and regarded reed-wetland (RRW) showed that the reed, averagely, in HRW is 4.2 m height, 1 cm diameter, 65/m2 density; in RRW is 2.4 m height, 3 mm diameter, 86/m2 density. These results indicated the regradation of the function of RRC in RRW. The results of laboratory work of sewage purification from reed soil column (RSC) $(0\~100cm)$ and wheat soil column (WSC) showed that the efficiency of purification to sewage, in RSC, is high than in WSC, especially for phosphorus. The efficiency of purification, in RSC, is $92.6\%$ for total phosphorus, $43.5\%$ for total nitrogen, $54.1\%$ fur COD, respectively; in WSC, is $86.0\%$ for total phosphorus, $241.3\%$ for total nitrogen, $29.8\%$ for COD, respectively.

  • PDF

Experimental and numerical investigation on bearing mechanism and capacity of new concrete plug structures

  • Weng, Yonghong;Huang, Shuling;Xu, Tangjin;Zhang, Yuting
    • Computers and Concrete
    • /
    • 제24권5호
    • /
    • pp.459-468
    • /
    • 2019
  • The stability and safety of concrete plug structure of diversion tunnel is crucial for the impoundment of upstream reservoir in hydropower projects. The ongoing Wudongde hydropower plant in China plans to adopt straight column plugs and curved column plugs to replace the traditional expanded wedge-shaped plugs. The performance of the proposed new plug structures under high water head is then a critical issue and attracts the attentions of engineers. This paper firstly studied the joint bearing mechanism of plug and surrounding rock mass and found that the quality and mechanical properties of the interfaces among plug concrete, shotcrete, and surrounding rock mass play a key role in the performance of plug structures. By performing geophysical and mechanical experiments, the contact state and the mechanical parameters of the interfaces were analyzed in detail and provide numerical analysis with rational input parameters. The safety evaluation is carried out through numerical calculation of plug stability under both construction and operation period. The results indicate that the allowable water head acting on columnar plugs is 3.1 to 7.4 times of the designed water head. So the stability of the new plug structure meets the design code requirement. Based on above findings, it is concluded that for the studied project, it is feasible to adopt columnar plugs to replace the traditional expanded wedge-shaped plugs. It is hoped that this study can provide reference for other projects with similar engineering background and problems.

상관분석 및 의사결정나무분석을 통한 하수처리시설의 에너지 소비량과 운영인자의 관계 분석 (Relationship between Energy Consumption and Operational Variables at Wastewater Treatment Plant)

  • 정용준;김예진
    • 한국물환경학회지
    • /
    • 제32권3호
    • /
    • pp.253-260
    • /
    • 2016
  • To reduce energy consumption in wastewater treatment plants (WWTPs), renewable energy applications such as small hydropower, solar energy, and wind energy are popular. However, it should be noticed that energy originated from operation of wastewater treatment process can be reduced through optimized operation based on analysis of factors affecting energy. In this research, the relationship to the various operational variables and influent factors was explored using correlation analysis and decision tree algorithm. Due to the non-linear characteristics of the process, it was difficult to find clear linear patterns through correlation analysis. However, decision tree algorithm showed its usefulness in uncovering hidden patterns that consume energy. As operational factors, influent flowrate, the amount of aeration, nitrate recycling pumping rate, and sludge wasting pumping rate were selected as important factors. For environmental factors associated with influent compositions and removal rate, BOD and T-N removal rate were selected as significant factors.

Effect of compressible membrane's nonlinear stress-strain behavior on spiral case structure

  • Zhang, Qi-Ling;Wu, He-Gao
    • Structural Engineering and Mechanics
    • /
    • 제42권1호
    • /
    • pp.73-93
    • /
    • 2012
  • With an active structural involvement in spiral case structure (SCS) that is always the design and research focus of hydroelectric power plant (HPP), the compressible membrane sandwiched between steel spiral case and surrounding reinforced concrete was often assumed to be linear elastic material in conventional design analysis of SCS. Unfortunately considerable previous studies have proved that the foam material serving as membrane exhibits essentially nonlinear mechanical behavior. In order to clarify the effect of membrane (foam) material's nonlinear stress-strain behavior on SCS, this work performed a case study on SCS with a compressible membrane using the ABAQUS code after a sound calibration of the employed constitutive model describing foam material. In view of the successful capture of fitted stress-strain curve of test by the FEM program, we recommend an application and dissemination of the simulation technique employed in this work for membrane material description to structural designers of SCS. Even more important, the case study argues that taking into account the nonlinear stress-strain response of membrane material in loading process is definitely essential. However, we hold it unnecessary to consider the membrane material's hysteresis and additionally, employment of nonlinear elastic model for membrane material description is adequate to the structural design of SCS. Understanding and accepting these concepts will help to analyze and predict the structural performance of SCS more accurately in design effort.

전력계통 보조서비스 제공에 따른 수력발전소의 전수비 분석 (Analysis for Energy Production and Water Supply Ratio of Hydropower-Plant Through Providing Power System Ancillary Service)

  • 정우진;이경배;임선택;김종겸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.250-251
    • /
    • 2011
  • 현대사회의 산업구조가 고도화 되고 IT 활용 기술이 발달함에 따라 전기품질에 대한 고급화가 요구되고 있다. 우리나라 전력계통을 운영하는 한국전력거래소는 급격한 부하변동에 대응하고 고품질의 전력을 공급하기 위해 출력의 증 감발 특성이 우수한 수력발전소의 보조서비스(주로 자동발전제어)를 활용하고 있다. 전력계통의 신뢰도 향상과 안정적인 운영 목적을 달성하기 위해 수력발전소가 계통보조서비스에 적극적으로 참여해야 하지만, 전력계통 보조서비스 제공으로 수력발전소의 전수비가 하락하는 문제가 있다. 따라서 본 논문에서는 이 문제를 해결하기 위해 수력발전소 전력계통 보조서비스 제공에 따른 전수비의 변화를 정량적으로 분석하고 검토하여 향후 수력발전소 운영 자료로 활용하고자 한다.

  • PDF

소수력 발전소에 적용하는 유도발전기의 동작 특성 (A Study on the Operation Characteristic of Induction Generator in the Small Hydropower Plant)

  • 김영국;김종겸
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.632-638
    • /
    • 2013
  • In this study, we described voltage fluctuation characteristics of distribution line during starting and normal operation condition of the small hydro generators. Based on these theories, we scrutinized the starting and operating characteristics of induction generators installed in two small hydro power plants that is connected to the distribution line and researched necessary factors when selecting the generator type. The type of turbines and capacity of generators are different. One is below 1,000kW and the other is above 1,000kW. Two generators are tested during starting, and it acts as motor not generator at the instant that the machine is connected to the grid. After connecting to the grid, the machine rotates above synchronous speed before converting to the generator mode. Therefore the characteristic of the generator during starting is same as it of motor.

연계계통에서 발전기 정지에 따른 주파수의 동적 변화 (Dynamic change of frequency after a generator outage in an Interconnection considering the primary control)

  • 블라디미르;문영환;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.95-99
    • /
    • 2001
  • Frequency is the unique physical value for all the interconnected systems. Therefore. the load frequency control is in the responsibility of all members in the interconnection power unbalance in one of the interconnected system can cause the problems in others. In the following text a brief description and the role of frequency in an interconnected system will be presented. Following is the short description of the Balkan Interconnection (UCTE Second Synchronous Zone) with schematic diagram. A Power-Frequency (P-f) dynamic model of a control area wil1 be shown. Model gives the analytical solution for frequency change versus a time after outage of a generator in the power system. This model will be applied to the Balkan Interconnection and compared with numerical approach. Advantages and drawbacks of the analytical method will be discussed Purpose of using this model is to investigate if the pumps in reversible hydropower plant will be underfrequency shed after the outage of the biggest generator unit in the interconnection, according %o (n-1) security postulate.

  • PDF