• 제목/요약/키워드: Hydrogen generation system

검색결과 280건 처리시간 0.022초

Mg2NiHx-CaF2 수소 저장 복합체의 물질 전과정 평가 (Material Life Cycle Assessment on Mg2NiHx-CaF2 Composites)

  • 황준현;신효원;홍태환
    • 한국수소및신에너지학회논문집
    • /
    • 제33권2호
    • /
    • pp.148-157
    • /
    • 2022
  • Research on hydrogen storage is active to properly deal with hydrogen, which is considered a next-generation energy medium. In particular, research on metal hydride with excellent safety and energy efficiency has attracted attention, and among them, magnesium-based hydrogen storage alloys have been studied for a long time due to their high storage density, low cost, and abundance. However, Mg-based alloys require high temperature conditions due to strong binding enthalpy, and have many difficulties due to slow hydrogenation kinetics and reduction in hydrogen storage capacity due to oxidation, and various strategies have been proposed for this. This research manufactured Mg2Ni to improve hydrogenation kinetics and synthesize about 5, 10, 20 wt% of CaF2 as a catalyst for controlling oxidation. Mg2NiHx-CaF2 produced by hydrogen induced mechanical alloying analyzed hydrogenation kinetics through an automatic PCT measurement system under conditions of 423 K, 523 K, and 623 K. In addition, material life cycle assessment was conducted through Gabi software and CML 2001 and Eco-Indicator 99' methodology, and the environmental impact characteristics of the manufacturing process of the composites were analyzed. In conclusion, it was found that the effects of resource depletion (ARD) and fossil fuels had a higher burden than other impact categories.

120 kW급 태양광 발전시스템 설치 및 실 계통연계 운전 결과 평가 (Test Results Grid Connection of 120 kW Power Generation System)

  • 황정희;안교상;임희천;김수창;김신섭
    • 한국수소및신에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.338-346
    • /
    • 2006
  • In this paper, the test results of medium-size(120 kW class) PV system which was installed in the Taeahn thermal power station of Korea Western Power Co., Ltd., were summarized for developing the practical technology to applicate high voltage grid connection PV system. The 120 kW photovoltaic system which was consisted of 1,300 modules, PCS, and 150 kVA transformer station has been operated since Aug. 05, 2005. For verifying the modeling results of PV system, the operation data was compared with modeling results which was executed commercial PSCAD/EMTD and Psim tools. An equivalent circuit model of a solar cell has been also used for solar array modeling. A series of parameters required for array modeling have been estimated from general specification data of a solar module. A PWM voltage source inverter(VIS) and its current control scheme have been analyzed by using P&O (perturbation and Observation) MPPT algorithms technique.

무인기용 연료전지 추진 시스템의 동력 관리 (Power Management of Fuel Cell Propulsion System for Unmanned Aerial Vehicles)

  • 김태규;심현철;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.13-16
    • /
    • 2007
  • 본 연구에서는 무인기용 추진 시스템으로 연료전지를 사용하였다. 연료전지 추진 시스템은 고항속 무인기를 위한 고에너지 밀도를 갖는 이상적인 대체 동력원이다. 연료전지 동력 시스템은 기폰 배터리의 5배 이상의 에너지 밀도를 제공한다. 액체상태로 저장되는 수소화붕소나트륨을 수소원으로 사용하였다. 수소 생성 시스템은 촉매 반응기, 펌프, 연료, 카트리지, 분리기로 구성된다. 연료전지와 리륨-폴리머 배터리의 하이브리드 동력 관리 시스템이 개발되었다. 모터, 펌프, 팬은 연료전지 시스댐의 피트백 신호에 따라 배터리 동력으로 작동되고 배터리는 연료전지의 잉여 동력으로 재충전되었다.

  • PDF

AMESet 기반 20 kW급 수소 연료전지 시스템 동특성 모델 해석 (Analysis of Dynamic Characteristics of 20 kW Hydrogen Fuel Cell System Based on AMESet)

  • 우종빈;김영현;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.465-477
    • /
    • 2023
  • In proton exchange membrane fuel cell (PEMFC), proper thermal management of the stack and moisture generation by electrochemical reactions significantly affect fuel cell performance. In this study, the PEMFC dynamic characteristic model was developed through Simcenter AMESim, a development program. In addition, the developed model aims to understand the thermal resin balance of the stack and performance characteristics for input loads. The developed model applies the thermal management model of the stack and the moisture content and permeability model to simulate voltage loss and stack thermal behavior precisely. This study extended the C based AMESet (adaptive modeling environment submodeling tool) to simulate electrochemical reactions inside the stack. Fuel cell model of AMESet was liberalized with AMESim and then integrated with the balance of plant (BOP) model and analyzed. And It is intended to be used in component design through BOP analysis. The resistance loss of the stack and thermal behavior characteristics were predicted, and the impact of stack performance and efficiency was evaluated.

이산화탄소 배출을 최소화하는 용융탄산염 연료전지 하이브리드 시스템들의 성능 비교 (Performance Comparison of Molten Carbonate Fuel Cell Hybrid Systems Minimizing Carbon Dioxide Emissions)

  • 안지호;윤석영;김동섭
    • 한국수소및신에너지학회논문집
    • /
    • 제28권1호
    • /
    • pp.30-39
    • /
    • 2017
  • Interests in fuel cell based power generation systems are on the steady rise owing to various advantages such as high efficiency, ultra low emission, and potential to achieve a very high efficiency by a synergistic combination with conventional heat engines. In this study, the performance of a hybrid system which combined a molten carbonate fuel cell (MCFC) and an indirectly fired micro gas turbine adopting carbon dioxide capture technologies was predicted. Commercialized 2.5 MW class MCFC system was used as the based system so that the result of this study could reflect practicality. Three types of ambient pressure hybrid systems were devised: one adopting post-combustion capture and two adopting oxy-combustion capture. One of the oxy-combustion based system is configured as a semi-closed type, while the other is an open cycle type. The post-combustion based system exhibited higher net power output and efficiency than the oxy-combustion based systems. However, the semi-closed system using oxy-combustion has the advantage of capturing almost all carbon dioxide.

저등급 열원으로 구동되는 병렬 열병합 발전시스템의 엑서지와 엔트랜시 성능 특성 (Exergy and Entransy Performance Characteristics of Cogeneration System in Parallel Circuit Using Low-Grade Heat Source)

  • 김경훈;김경진;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제32권1호
    • /
    • pp.77-85
    • /
    • 2021
  • In this paper, entransy analysis is carried out for combined heat and power (CHP) generation system driven by low-grade heat source compared with energy and exergy analyses. The system consists of an organic Rankine cycle (ORC) and an additional process heater in a parallel circuit. Special attention is paid to the effects of the source temperature, turbine inlet pressure, and the working fluid on the thermodynamic performance of the system. Results showed that the work efficiency of entransy is higher than that of energy but lower than that of exergy, wheress the process heat efficiency of entransy is lower than that of energy but higher than that of exergy. Entrancy analysis showed the potential to complement the exergy analysis in the optimal design of the energy system.

Development of kW Class SOFC Systems for Combined Heat and Power Units at KEPRI

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Keun-Bae;Yoo, Young-Sung
    • 한국세라믹학회지
    • /
    • 제45권12호
    • /
    • pp.772-776
    • /
    • 2008
  • The Korea Electric Power Research Institute (KEPRI) has been developing planar solid oxide fuel cells (SOFCs) and power systems for combined heat and power (CHP) units. The R&D work includes solid oxide fuel cell (SOFC) materials investigation, design and fabrication of single cells and stacks, and kW class SOFC CHP system development. Anode supported cells composed of Ni-YSZ/FL/YSZ/LSCF were enlarged up to $15{\times}15\;cm^2$ and stacks were manufactured using $10{\times}10\;cm^2$ cells and metallic interconnects such as ferritic stainless steel. The first-generation system had a 37-cell stack and an autothermal reformer for use with city gas. The system showed maximum stack power of about $1.3\;kW_{e,DC}$ and was able to recover heat of $0.57{\sim}1.2\;kW_{th}$ depending on loaded current by making hot water. The second-generation system was composed of an improved 48-cell stack and a prereformer (or steam reformer). The thermal management subsystem design including heat exchangers and insulators was also improved. The second-generation system was successfully operated without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_{e,DC}$ with hydrogen and $1.2\;kW_{e,DC}$ with city. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water. Recently KEPRI manufactured a 2kW class SOFC stack and a system by scaling up the second-generation 1kW system and will develop a 5kW class CHP system by 2010.

광어노드의 수소 제조와 광전기 특성에 관한 상관관계 연구 (Study on Relation between $H_2$ Evolution and Photoelectrical Properties of Photoanode)

  • 배상현;강준원;심은정;윤재경;주현규
    • 한국수소및신에너지학회논문집
    • /
    • 제18권3호
    • /
    • pp.244-249
    • /
    • 2007
  • The present work considers the concept of enzymatic photoelectrochemical generation of hydrogen through water splitting using a Xe lamp as a source of light. A solar cell was applied to the system in order to shift the level of electrochemical energy of the system, resulting in the rate of hydrogen production at $43\;{\mu}mol/(cm^2{\times}hr)$ in cathodic compartment with an anodized tubular $TiO_2$ electrode(ATTE, $5^{\circ}C$/1hr in 0.5 wt% HF-$650^{\circ}C$/5hr). The trend of the rate of hydrogen production, for the ATTEs with different annealing temperature from $350^{\circ}C$ to $850^{\circ}C$, fairly well coincided with the photoelectrical properties measured by potentiostat. The actual chemical bias through imposition of two electrolytes of different pHs between anode(13.68) and cathode(7.5) was 0.24eV.

발전용 대형 엔진 적용을 위한 천연가스-디젤 혼소에 대한 수치 해석적 연구 (Numerical Study on Co-Combustion in Diesel Engine for Heavy-Duty Power Generation)

  • 서동균;허광범;정연태;김의현
    • 한국수소및신에너지학회논문집
    • /
    • 제26권4호
    • /
    • pp.369-376
    • /
    • 2015
  • Recently KEPCO, KOGAS and other institutions are jointly conducting an R&D for the development and demonstration of the power generation system based on a natural gas/diesel engine on an island. As a preliminary study, co-combustion in the dual fuel engine, which is expected to produce a few mega-watts of electricity, was modeled and calculated using computational fluid dynamics (CFD). The applied key assumptions are 2-dimensional axisymmetric, transient and static volume chemical reaction. Based on the selected blending ratio, which is the key operating condition, natural gas is substituted instead of diesel fuel (basis of high heating value). Results showed that as the blending ratio increases, the reaction rate of the combustion increases and thus maximum temperature is reached more rapidly. For the optimal performance, various geometric or operational studies will further be conducted.

수전해 시스템 성능 향상을 위한 능동 이온수송 기술 연구 (A Study on Active Ion Transport Technology to Improve Water Electrolysis System Performance)

  • 김현중;궈하오;김상영
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.132-140
    • /
    • 2023
  • In this study, rotary magnet holder (RMH) was manufactured to analyze the ion transport effect according to the rotating magnetic field for the hydrogen production efficiency by alkaline water electrolyte. In the experiment, the voltage signal according to the magnet arrangement inside the RMH, the rotation speed, and the rotation time was measured using the voltage measurement module. As a result of the voltage signal measurement experiment, the average potential difference increased as the rotation speed of the RMH increased. Through the results of the voltage signal measurement experiment, the most efficient magnet arrangement (case 2) was applied to the RMH to conduct a water electrolysis experiment. A 20% NaOH aqueous solution was filled in the electrolytic cell, and a direct current 2 V constant voltage was applied to measure the current value according to the RMH rotation to compare the hydrogen generation amount. When rotating at 100 RPM, the hydrogen production efficiency increased by 8.06% compared to when not rotating. Considering the area exceeding +25 mA, which was not measured at the beginning of the experiment, an increase in hydrogen production of about 10% or more can be expected.