• 제목/요약/키워드: Hydrogen Fuel Cell

검색결과 1,157건 처리시간 0.026초

등가 연료 소모량을 이용한 연료전지 자동차의 하이브리화에 대한 평가 (Evaluation of Hybridization in FCVs Based on Equivalent Fuel Consumption)

  • 정춘화;신창우;박영일;차석원
    • 한국자동차공학회논문집
    • /
    • 제19권5호
    • /
    • pp.143-147
    • /
    • 2011
  • Operating points of a fuel cell system (FCS) can be shifted to its high-efficiency region by hybridization in a fuel cell hybrid vehicle (FCHV), so the hydrogen can be saved. In this paper, the hydrogen consumption of an FCHV is compared to that of a fuel cell vehicle (FCV). A power management strategy is applied to the FCHV and the related simulation is carried out. The concept of equivalent hydrogen consumption is introduced in order to consider the effect of the difference between initial and final battery SOC on the total hydrogen consumption.

연료전지 이젝터 시스템에 관한 수치해석적 연구 (A Computational Study of the Fuel-Cell Ejector System)

  • 이준희;이해동;남궁혁준;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3191-3196
    • /
    • 2007
  • The present study addresses a method to operate a fuel-cell system effectively using a recirculation ejector which recycles wasted hydrogen gas. Configuration of a recirculation ejector is changed to investigate the flow behavior through it under varying operating conditions, and how such conditions affect the fuel-cell hydrogen cycle. The numerical simulations are based on a fully implicit finite volume scheme of the axisymmetric, compressible, Reynolds-Averaged, Navier-Stokes equations for hydrogen gas, and are compared with available experimental data for validation. The results show that a hydrogen recirculation ratio is effectively controlled by a configurational alteration within the operational region in which the recirculation passage doesn't plugged by a sonic line.

  • PDF

연료전지자동차의 고압수소저장시스템 신뢰성 평가 (The Evaluation of Reliability for the High Pressure Hydrogen Storage System of Fuel Cell Vehicle)

  • 장규진;최영민;안병기;임태원
    • 한국수소및신에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.266-275
    • /
    • 2008
  • The performance improvement of each part for durability, safety and cost of high pressure storage system for fuel cell vehicle has been focused so far. However, for the mass production of fuel cell vehicle, it is necessary to evaluate durability and safety in system module and vehicle level. The test procedure to evaluate vibration and collision safety of high pressure hydrogen storage system for the fuel cell vehicle is established and its reliability is verified.

수소연료를 이용하는 원자층증착 박막전해질 세라믹연료전지의 초기성능 저하에 관한 연구 (A Study on the Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Atomic Layer-Deposited Thin-Film Electrolyte)

  • 지상훈
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.410-416
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~17% for 40 minutes, which rapidly decreased in the early stage of the performance evaluation but gradually decreased. The open circuit voltage ratio decreased with respect time; however, its time behavior was remarkably different with the reduction behavior of the peak power density ratio. The activation resistance ratio increased as ~15% for 40 minutes, which was almost similar with the time behavior of the peak power density ratio.

실험계획법을 이용한 고온 고분자 전해질 막 연료전지의 운전조건 최적화 연구 (Study on Optimization of Operating Conditions for High Temperature PEM Fuel Cells Using Design of Experiments)

  • 김진태;김민진;손영준
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.50-60
    • /
    • 2013
  • High temperature proton exchange membrane fuel cells (PEMFCs) using phosphoric acid (PA) doped polybenzimidazole (PBI) membranes have been concentrated as one of solutions to the limits with traditional low temperature PEMFCs. However, the amount of reported experimental data is not enough to catch the operational characteristics correlated with cell performance and durability. In this study, design of experiments (DOE) based operational optimization method for high temperature PEMFCs has been proposed. Response surface method (RSM) is very useful to effectively analyze target system's characteristics and to optimize operating conditions for a short time. Thus RSM using central composite design (CCD) as one of methodologies for design of experiments (DOE) was adopted. For this work, the statistic models which predict the performance and degradation rate with respect to the operating conditions have been developed. The developed performance and degradation models exhibit a good agreement with experimental data. Compared to the existing arbitrary operation, the expected cell lifetime and average cell performance during whole operation could be improved by optimizing operating conditions. Furthermore, the proposed optimization method could find different new optimal solutions for operating conditions if the target lifetime of the fuel cell system is changed. It is expected that the proposed method is very useful to find optimal operating conditions and enhance performance and durability for many other types of fuel cell systems.

Highly Sulfonated Poly(Arylene Biphenylsulfone Ketone) Block Copolymers Prepared via Post-Sulfonation for Proton Conducting Electrolyte Membranes

  • Lee, Kyu Ha;Chu, Ji Young;Kim, Ae Rhan;Nahm, Kee Suk;Yoo, Dong Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1763-1770
    • /
    • 2013
  • A series of the block copolymers were successfully synthesized from post-sulfonated hydrophilic and hydrophobic macromers via three-step copolymerization. The degrees of sulfonation (DS) of the copolymers (10%, 30%, or 50%) were controlled by changing the molar ratio of the hydrophilic and hydrophobic parts. The resulting block copolymers were characterized by $^1H$ NMR and other technologies. The membranes were successfully cast using dimethyl sulfoxide (DMSO) solution at $100^{\circ}C$. The copolymers were characterized to confirm chemical structure by $^1H$ NMR and FT-IR. Thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) demonstrated that all sulfonated block copolymers exhibited good thermal stability with an initial weight loss at temperatures above $240^{\circ}C$. The membranes showed acceptable ion exchange capacity (IEC) and water uptake values in accordance with DS. The maximum proton conductivity was 184 mS $cm^{-1}$ in block copolymer-50 at $60^{\circ}C$ and 100% relative humidity, while the conductivity of Nifion-115 was 160 mS $cm^{-1}$ under the same measurement conditions. AFM images of the block copolymer membranes showed well separated the hydrophilic and hydrophobic domains. From the observed results it is that the prepared block membranes can be considered as suitable polymer electrolyte membranes for the application of polymer electrolyte membrane fuel cells (PEMFC).

가정용 연료전지 시스템 내부 수소 누출 시 센서 응답 특성에 관한 연구 (An Experimental Study on the Sensor Response at Hydrogen Leakage in a Residential Fuel Cell System)

  • 김영두;신동훈;정태용;남진현;김영규;이정운
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.378-383
    • /
    • 2009
  • Hydrogen is the primary fuel in fuel cell systems. Because of high inflammation and explosion possibility of hydrogen, fuel cell systems require safety measures to prevent hydrogen hazard upon leakage. In this study, a model enclosure was made by referring to a commercial residential fuel cell system and hydrogen leakage experiments and computational simulations were conducted therein. Hydrogen was injected into the cavity through leakage holes located at the bottom while its flow rate was precisely controlled using MFC. The transient sensor signals from hydrogen sensors installed inside the enclosure were recorded and analyzed. The hydrogen sensor signals showed different delay times depending on their position relative to a leakage point, which indicated that hydrogen generally moves upward and accumulates at the upper region of a closed cavity. The inflammable regions with hydrogen concentration over 4% LEL were observed to locate near the leakage hole initially, and broaden towards the upper cavity region afterward. The simulation result showed that detection time at the hydrogen sensor was similar to the pattern of experimental results. However, the maximum concentration of hydrogen had a gap between experiment and simulation at detect point due to measurement errors and reaction rate.

양극 닫힌계 작동에서 수소 배출 방법에 의한 고분자전해질 연료전지 성능 영향 (Effect of Hydrogen Purge Mode on the Polymer Electrolyte Membrane Fuel Cell (PEMFC) Performance under Dead-ended Anode Operation)

  • 김준섭;김준범
    • 공업화학
    • /
    • 제30권6호
    • /
    • pp.687-693
    • /
    • 2019
  • 수소전기차와 발전을 시작으로 수소연료전지 시장이 성장하면서 연료전지와 수소의 수요가 증가하고 있으므로, 조기 상용화와 시장 활성화를 위하여 연료전지의 내구성과 연료 이용효율에 관한 연구가 진행되어야 한다. 본 연구에서는 연료전지의 성능과 연료 이용효율을 최적화하기 위하여 양극 닫힌계의 운전조건에 대한 연구를 수행하였다. 부하 전류에 대한 배출 조건과 수소 공급 압력이 고분자전해질 연료전지의 성능에 미치는 영향에 대하여 평가하였고, 전해질막 두께에 대한 물의 역확산 영향을 분석하였다. 양극 닫힌계에서 수소극에 쌓인 물은 연료전지 전압이 3% 감소한 경우에 솔레노이드 밸브를 열어 배출하였다. 수소 공급 압력은 0.1~0.5 bar, 배출 시간은 0.1~1 s까지 변화시키면서 실험을 수행하였다. NR 211 (25.4 um) 전해질막의 경우 0.1 bar의 수소 공급 압력과 0.1 s 배출 시간 조건에서 수소 이용효율 98.9%의 가장 높은 연료 이용효율을 보였지만 잦은 flooding으로 인하여 장시간 운전 시 연료전지의 성능이 감소하였다. 이에 반해 NR 212 (50.8 um)의 전해질막에서 생성된 물과 질소의 역확산 속도를 늦추어 배출 간격을 늘리고 연료 이용효율을 높일 수 있었다.

Combined Effect of Catholyte Gap and Cell Voltage on Syngas Ratio in Continuous CO2/H2O Co-electrolysis

  • Ha, Min Gwan;Na, Youngseung;Park, Hee Young;Kim, Hyoung-Juhn;Song, Juhun;Yoo, Sung Jong;Kim, Yong-Tae;Park, Hyun S.;Jang, Jong Hyun
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권4호
    • /
    • pp.406-414
    • /
    • 2021
  • Electrochemical devices are constructed for continuous syngas (CO + H2) production with controlled selectivity between CO2 and proton reduction reactions. The ratio of CO to H2, or the faradaic efficiency toward CO generation, was mechanically manipulated by adjusting the space volume between the cathode and the polymer gas separator in the device. In particular, the area added between the cathode and the ion-conducting polymer using 0.5 M KHCO3 catholyte regulated the solution acidity and proton reduction kinetics in the flow cell. The faradaic efficiency of CO production was controlled as a function of the distance between the polymer separator and cathode in addition to that manipulated by the electrode potential. Further, the electrochemical CO2 reduction device using Au NPs presented a stable operation for more than 23 h at different H2:CO production levels, demonstrating the functional stability of the flow cell utilizing the mechanical variable as an important operational factor.

소형 수소추진선박 기술 개발 및 실증 (The Technology Development and Substantiation of Small Hydrogen Powered Vessel)

  • 임재완;이세준;윤상진;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.555-561
    • /
    • 2023
  • In this study, we proposed a standard model for the design, construction and demonstration of the technology development and substantiation of small hydrogen powered vessel in order to respond to the alternative fuel-using vessel market that requires the use of low-carbon/carbon-free fuel as a greenhouse gas reduction measure. The hydrogen fuel cell-based electric propulsion system developed through this is optimized through performance and durability tests on the land-based test site (LBTS), and the electric propulsion system applied to this result is mounted on a small hydrogen propulsion vessel and operated. Simultaneously, through the digital twin technology between the LBTS and the hydrogen-propelled vessel on the sea, the technology that can predict and diagnose the problems that can occur in the electric propulsion system of the vessel is applied to carry out the empirical study of the hydrogen-propelled vessel. In addition, we propose a commercialization model by analyzing the economic feasibility of the demonstration vessel.