• 제목/요약/키워드: Hydro-Pressure test

검색결과 60건 처리시간 0.028초

KSLV-1 Kick Motor 노즐 수압시험 (KSLV-I Kick Motor Nozzle Hydro-Pressure Test)

  • 유재석;김병훈;조인현;장영순
    • 항공우주기술
    • /
    • 제7권1호
    • /
    • pp.202-209
    • /
    • 2008
  • KSLV-1 2단 Kick Motor 노즐은 연소 동안 고온 고압의 환경에 노출된다 이러한 고압 환경에서 노즐부의 안전성검토를 위하여 KM 노즐 수압시험을 수행하였다. KM 수압시험 [1]과 다른 점은 실물형 잡입부 내열재가 사용되었으며 목부 내열재도 실물형과 유사하게 제작되어 조립되었다. 수압시험은 MEOP (975 psi, GT#2 기준)의 40% 예비시험, 120% 수압시험 2회 반복 및 153% 수압시험을 수행하였다.

  • PDF

Numerical Investigation of Pressure Fluctuation Reducing in Draft Tube of Francis Turbines

  • Li, WF;Feng, JJ;Wu, H;Lu, JL;Liao, WL;Luo, XQ
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권3호
    • /
    • pp.202-208
    • /
    • 2015
  • For a prototype turbine operating under part load conditions, the turbine output is fluctuating strongly, leading to the power station incapable of connecting to the grid. The field test of the prototype turbine shows that the main reason is the resonance between the draft tube vortex frequency and the generator natural vibration frequency. In order to reduce the fluctuation of power output, different measures including the air admission, water admission and adding flow deflectors in the draft tube are put forward. CFD method is adopted to simulate the three-dimensional unsteady flow in the Francis turbine, to calculate pressure fluctuations in draft tube under three schemes and to compare with the field test result of the prototype turbine. Calculation results show that all the three measures can reduce the pressure pulsation amplitude in the draft tube. The method of water supply and adding flow deflector both can effectively change the frequency and avoid resonance, thus solving the output fluctuation problem. However, the method of air admission could not change the pressure fluctuation frequency.

필라멘트 와인딩 복합재 압력용기의 섬유 방향 물성 평가 기법 (Test Method to Evaluate the Fiber Material Properties of Filament Wound Composite Pressure Vessel)

  • 황태경;박재범;김형근
    • Composites Research
    • /
    • 제23권3호
    • /
    • pp.37-42
    • /
    • 2010
  • 섬유 방향 강성과 강도는 복합재 압력 용기의 성능과 밀접한 관계를 갖기 때문에, 압력 용기 구조 설계시에 다른 물성들보다 중요 설계 인자가 된다. 즉 복합재 압력 용기의 내압 변형 및 파열 압력은 섬유 물성에 의해 큰 영향을 받는다. 그러므로 정확한 섬유 방향 물성을 측정할 수 있는 기법을 확립하는 것이 복합재 압력 용기 설계 전에 우선되어야 한다. 그러나 복합재 압력용기의 섬유 방향 물성은 제작 공정 변수(와인딩 장비, 작업자, 작업환경 등)와 크기 효과에 의해 큰 영향을 받으므로 기존의 시편 시험 방법으로는 정확한 섬유 방향 물성 측정이 어렵다. 섬유 물성을 측정하는 가장 이상적인 시험 방법은 실물 압력용기 파괴시험이지만 많은 비용이 소요되어, 제품으로부터 다량의 링 시편을 채취, 내압 시험을 할 수 있는 Hoop ring 시험 방법이 제시되었다. Hoop ring 시험과 실물 압력용기의 수압 파괴 시험으로부터 구한 섬유 방향 물성들은 근접된 좋은 일치를 나타내었다.

소수력 발전설비 성능평가 시스템 구축 (Construction of small hydropower facilities performance evaluation system)

  • 김영준;김용열;조용;고재명
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.193.2-193.2
    • /
    • 2010
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

소수력 발전설비 성능평가 시스템 구축 (Construction of small hydropower facilities performance evaluation system)

  • 김영준;조용;고재명
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.206.2-206.2
    • /
    • 2011
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

ANALYSIS OF PRESTRESSED CONCRETE CONTAINMENT VESSEL (PCCV) UNDER SEVERE ACCIDENT LOADING

  • Noh, Sang-Hoon;Moon, Il-Hwan;Lee, Jong-Bo;Kim, Jong-Hak
    • Nuclear Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.77-86
    • /
    • 2008
  • This paper describes the nonlinear analyses of a 1:4 scale model of a prestressed concrete containment vessel (PCCV) using an axisymmetric model and a three-dimensional model. These two models are refined by comparison of the analysis results and with testing results. This paper is especially focused on the analysis of behavior under pressure and the temperature effects revealed using an axisymmetric model. The temperature-dependent degradation properties of concrete and steel are considered. Both geometric and material nonlinearities, including thermal effects, are also addressed in the analyses. The Menetrey and Willam (1995) concrete constitutive model with non-associated flow potential is adopted for this study. This study includes the results of the predicted thermal and mechanical behaviors of the PCCV subject to high temperature loading and internal pressure at the same time. To find the effect of high temperature accident conditions on the ultimate capacity of the liner plate, reinforcement, prestressing tendon and concrete, two kinds of analyses are performed: one for pressure only and the other for pressure with temperature. The results from the test on pressurization, analysis for pressure only, and analyses considering pressure with temperatures are compared with one another. The analysis results show that the temperature directly affects the behavior of the liner plate, but has little impact on the ultimate pressure capacity of the PCCV.

고준위폐기물처분장 공학적방벽의 열-수리-역학적 거동 연구: 엔지니어링 규모의 실증실험 (Thermal-Hydro-Mechanical Behaviors in the Engineered Barrier of a HLW Repository: Engineering-scale Validation Test)

  • 이재완;조원진
    • 터널과지하공간
    • /
    • 제17권6호
    • /
    • pp.464-474
    • /
    • 2007
  • 고준위폐기물처분장의 성능 및 안전성 향상을 위해서 공학적방벽(engineered barrier)에 대한 실증이 필요하다. 우리나라 기준처분시스템에 대한 엔지니어링 규모의 실험장치(KENTEX)를 제작 설치하고, 공학적방벽에서의 열-수리-역학적 거동 규명을 위한 실증실험을 수행하였다. KENTEX 실험은 2005년 5월 31일에 시작되어 현재 성공적으로 진행 중에 있으며, 지금까지 얻어진 실험결과로부터 공학적방벽에서의 열-수리-역학적 거동에 대한 중간결론을 얻을 수 있었다. 벤토나이트 블록 내 온도는 실험 시작 후 수 주 만에 정상상태에 도달하였고, 온도분포는 히터에 가까울수록 높고 멀어질수록 낮은 값을 보였다. 수분함량은 히터 쪽보다는 지하수가 유입되는 실린더 벽면 부근에서 높은 값을 가졌고, 건조-습윤 과정에 의한 벤토나이트 블록의 수화는 측정위치에 따라 달랐다. 실험기간 동안 벤토나이트 블록에 작용하는 압력은 블록의 포화도 (그 결과, 팽윤압)이 증가할수록 증가하였다. 히터 부근에서는 벤토나이트의 열응력이나 블록 공극 내 증기압도 중요한 역할을 하였다.

해외 수력발전설비 성능평가설비 및 평가 방법 (Performance evaluation facilities and evaluation methods for hydropower equipment)

  • 김영준;김용열;조용;고재명
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.194-194
    • /
    • 2010
  • The variable demand on the energy market, as well as the limited energy storage capabilities, requires a great flexibility in operating hydraulic turbines. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and/or maximum steady-state runaway speed, as well as guarantees related to cavitation. Performance test are conducted by the test standard. Test codes based on extensive research data are written under the leadership of an IEC. Performance evaluation is carry out several test(performance test, cavitation test and runaway test). The paper presents the international turbine test laboratory and performance test standard.

  • PDF

광섬유 센서를 이용한 복합재료 고압탱크 변형률 측정 (Strain monitoring of the composite high pressure tanks using the FBG sensors)

  • 박재성;윤종훈;공철원;장영순;이원복;노태호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.141-145
    • /
    • 2003
  • The FBG sensors are inserted on the liners of the filament wound pressure tanks. The strains near the welding region of the liners are monitored in the hydro-pressurizing tests. The hydro-pressurizing tests consist of the proof tests at 4500 or 3300 psi and repeated test at the operating pressure, 3000 psi. The FBG sensors work well under $3000\mu\varepsilon$, but the strains calculated from the reflected signals are instable at the high strain level. The transverse compression on the sensor head results in the split of the reflected peaks, and the calculating algorism from the split peaks is not robust under the various signal condition. The FBG sensors fracture near $7500\mu\varepsilon$ level and lose their function permanently.

  • PDF

수차 발전기의 실시간 효율관리 기법 연구 (The study on the technic of real time efficiency management of hydro turbine -generator)

  • 김승효;권영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1018-1020
    • /
    • 2000
  • In the operation and maintenance activity of hydro turbine generator, one of the important parameters is the efficiency. This study analyze the case of efficiency management by pressure time method and survey the application of this method through the actual test. And it is confirmed that the Pressure time method exccesively limit the general condition to be applied. If index method is used for efficiency management because the index method calibrated by absolute discharge(by flow of pressure time method) is very accurate. it make to be able to manage the realtime efficiency.

  • PDF