In this paper, a compression to tensile load converter device was developed to determine the anisotropic tensile strength of concrete. The samples were made from a mixture of water, fine sand and cement, respectively. Concrete samples with a hole at its center was prepared and subjected to tensile loading using the compression to tensile load converter device. A hydraulic load cell applied compressive loading to converter device with a constant pressure of 0.02 MPa per second. Compressive loading was converted to tensile stress on the sample because of the overall test design. The samples have three different configurations related to loading axis; 0, $45^{\circ}$, $-45^{\circ}$. A series of finite element analysis were done to analyze the effect of hole diameter on stress concentration of the hole side along its horizontal axis to provide a suitable criterion for determining the real tensile strength of concrete. Concurrent with indirect tensile test, Brazilian test and three point loading test were also performed to compare the results from the three methods. Results obtained by this device were quite encouraging and show that the tensile strengths of concrete were similar in different directions because of the homogeneity of bonding between the concrete materials. Also, the indirect tensile strength was clearly lower than the Brazilian test strength and three point loading test.
1970년대에 여러 연구자가 시제품 시험장비를 가지고 인발시험을 실시하였으며, 인발시험은 콘크리트 강도를 결정하는 신뢰할 만한 비파괴검사 방법(NDT)으로 입증되었다. 우리는 고강도 콘크리트 강도를 추정하기 위하여 직경 10 mm볼트에 홈이 파인 파단형 인발 볼트와 인발너트, 그리고 로드셀이 필요 없는 오일 유압펌프를 포함한 간이 인발시험법을 제안하였다. 저비용, 간편성 및 편의성을 갖는 간이인발시험의 이점을 검증하기 위하여, 30 MPa 및 50 MPa 급 두가지 유형의 콘크리트로 제작된 4개의 모의벽체를 대상으로 로드셀을 장착한 간이인발시험을 사용하여 인발시험을 실시하였다. 인발하중과 콘크리트 압축강도는 재령 7일까지는 매일, 그리고 14일, 21일, 28일에 측정되었다. 시험결과 인발하중과 콘크리트 압축강도는 매우 밀접한 상관관계를 보여주었으며 따라서 인발하중이 현장에서 구조물의 고강도 콘크리트 강도를 평가할 수 있다는 것을 확인할 수 있었다. 파단형 인발볼트 직경과 콘크리트 강도와의 관계식으로 y=0.05x+3.79(x=콘크리트 압축강도, y=파단형 인발볼트 직경)이 도출되었으며 결정계수는 0.88로 나타났다.
A compression to tensile load transforming (CTT) device was developed to determine indirect tensile strength of concrete material. Before CTT test, Particle flow code was used for the determination of the standard dimension of physical samples. Four numerical models with different dimensions were made and were subjected to tensile loading. The geometry of the model with ideal failure pattern was selected for physical sample preparation. A concrete slab with dimensions of $15{\times}19{\times}6cm$ and a hole at its center was prepared and subjected to tensile loading using this special loading device. The ratio of hole diameter to sample width was 0.5. The samples were made from a mixture of water, fine sand and cement with a ratio of 1-0.5-1, respectively. A 30-ton hydraulic jack with a load cell applied compressive loading to CTT with the compressive pressure rate of 0.02 MPa per second. The compressive loading was converted to tensile stress on the sample because of the overall test design. A numerical modeling was also done to analyze the effect of the hole diameter on stress concentrations of the hole side along its horizontal axis to provide a suitable criterion for determining the real tensile strength of concrete. Concurrent with indirect tensile test, the Brazilian test was performed to compare the results from two methods and also to perform numerical calibration. The numerical modeling shows that the models have tensile failure in the sides of the hole along the horizontal axis before any failure under shear loading. Also the stress concentration at the edge of the hole was 1.4 times more than the applied stress registered by the machine. Experimental Results showed that, the indirect tensile strength was clearly lower than the Brazilian test strength.
액성한계 두 배 이상의 매우 높은 함수비를 갖는 준설점토의 압밀특성을 파악하기 위해 Rowe cell 압밀시험기를 사용하여 압밀시험을 실시하였다. 초기함수비 변화가 압밀특성에 주는 영향을 검토하기 위해서 함수비를 $100\~150\%로$ 변화시켜서 실험을 수행하였고 재성형 준설점토의 압밀특성과 비교하였다. 실험결과로부터 준설점토의 초기함수비가 증가할수록 e-logP 곡선의 비선형적 거동이 뚜렷하였고, 하중단계 40kPa까지는 곡선의 기울기 변화가 급변하였으며 그 이후의 하중단계에서는 완만한 형상을 보여주었다. 압축지수비는 Mesri(1973)가 제안한 값의 범위 내에 존재하였으며, 초기함수비변화가 압밀계수에 미치는 영향은 거의 없었고 오히려 압밀하중의 크기가 연직압밀계수에 영향을 미치고 있음을 알 수 있었다. 또한 대형압밀시험기를 이용하여 압밀기간 중 층 두께의 변화를 고려하여 압밀기간을 산정하는 Mikasa이론과 그렇지 않은 Terzaghi의 이론을 비교하였다. 그 결과 변형률이 큰 지반에서의 압밀기간은 압밀기간 중 층 두께의 변화를 고려한 Mikasa 이론의 경우가 그렇지 않은 경우보다 실측치에 근사하게 산정되었다.
본 연구의 목적은 낙동강 내에 위치한 강정고령보 구간을 대상으로 EFDC 모델을 검정하고, 보 구간의 유량에 따른 체류시간과 유입수 인 농도 변화가 수질 및 조류 그룹별(규조류, 녹조류, 남조류) 생체량에 미치는 영향을 평가하는데 있다. 2018년 실험자료를 이용하여 모델을 검정한 결과, 보 구간의 수위와 수온의 수직 분포, DO, 유기물, 질소, 인 계열의 시계열 변화를 적절히 모의하였다. 조류 그룹별 생체량 예측에 있어서는 계절별 변동 특성은 적절히 재현하였으나, 일부기간에 실측값과 편차가 크게 나타났다. 보의 관리수위와 유량을 조절하는 시나리오 모의결과, 보의 운영 수위를 낮출수록 유량을 증가시킬수록 수온성층이 완화 또는 해소되는 것으로 분석되었다. 강정고령보에서 수온성층이 해소된 유속은 약 0.1 m/s였으며, 이는 금강의 백제보에서 연구결과와 일치한다. 2Q 유량 시나리오 모의결과, Chl-a는 8.7% 감소하였고 규조류와 녹조류 세포수 밀도도 감소하였다. 하지만 남조류 세포수는 오히려 증가하였는데, 그 이유는 유량이 증가함에 따라 유속이 빨라져 상류경계조건의 높은 남조류 농도가 하류에 직접 영향을 끼친 것으로 나타났다. 유입수 인 부하 농도(평균 0.056mg/L)를 50% 수준으로 저감하는 시나리오 모의결과, Chl-a는 13.6 % 감소하였다. 연구결과는 강정고령보의 조류 과잉성장을 억제하기 위해서는 수리학적 제어와 함께 상류 유입 조류 농도와 인 부하량 저감이 동시에 고려되어야 함을 시사한다.
본 연구는 하천 유역에 대한 수문분석의 대표적인 요소인 유출량과 오염부하량을 추정하는데 있어서 기존의 수문학적 모델링 방법과는 달리 GIS분석기법을 적용하였다. 분석을 위한 기본 자료로는 토양도, 토지이용도, 수계도, 강수량 등의 유역형태 및 기상학적 특성을 정량화한 지리정보자료와 수치표고모형과 같은 지형 자료를 이용하였다. 토양, 토지 이용 인자에 대한 기준값으로는 미국토양보존국(SCS)에서 제시하고 있는 토양 분류 기준 및 유출곡선지수(CN)와 환경부에서 제시하고 있는 토양의 기대평균농도(EMC)를 적용하였다. 고흥군 고읍천 유역의 2010년 7월~8윌의 9개 강우사상에 대하여 유출량 및 오염부하량의 추정값과 실측값을 비교한 결과, 유출량은 평균 3.86%의 차이를 갖으며, 오염부하량은 평균 5.67%의 차이를 갖는 것으로 분석되었다. 그러나 각 강우사상별 분석결과 추정 유출량은 강우량이 적을수록 그 오차가 매우 커지며, 추정 오염부하량은 강우량 및 계절의 변화에 따라 오차량에 차이가 있는 것으로 분석되었다. 향후 우리나라의 토양 및 토지이용에 적합한 배수 분류기준과 지역별 특성을 고려한 기대평균농도가 제시된다면 보다 정확한 유출량 및 오염부하량의 추정이 가능할 것으로 판단된다.
A hydraulic tensile test machine (HSTM) is one of the devices used to obtain the flow stress of a material during high-speed elongation. This paper first describes some features of a newly built HSTM. The improvement histories of the upper and lower jigs, which are the most vital parts of the HSTM, are also presented. We have frequently witnessed test failures with 1st generation jigs and specimens due to slip between the jig and specimen. 2nd generation jigs provide more stable test results, but the use of a longer upper jig induces excessive vibration and consequently makes it difficult to attach an environment chamber. 3rd generation jigs have some advances in terms of the symmetric fastening between the upper jig and specimen, as well as an exemption from direct contact between the lower jig and specimen. The performance of an environment chamber is verified by high and low temperature tests. A high-speed displacement measurement system is introduced based on a high-speed camera and motion-tracking software with aid of a surface grid device for the specimen.
This study aims to investigate the effects of the microstructures and nodule type on the fatigue characteristics of cast iron. Fatigue tests were carried out in tension-tension mode using a servo-hydraulic testing machine with load control mode operating at a frequency of 15 Hz. The tests were conducted at stress ratio R=Kmin/Kmax, of 0.1. Initial crack ${\Dalta}K$ values were highly performed with increase in tensile strength of DCI fatigue specimens. ${\Dalta}K_{th}$ region, fatigue crack propagation was primarily advanced through cell boundary and in periphery of near nodule. Fatigue crack propagation rate of D2 consisted with 2Phase(Ferrite+Pearlite) was slow due to crack closure enhanced by crack deflection and occurred crack branching. The generation of crack branch was occurred due to interaction of crack-nodule. At Threshold and Paris zone, the fractographs of the fatigue fracture surface for DCI show typical striations of a ductile fracture and isolated cleavage planes near graphite. The effect of microstructure on fatigue crack propagation of GC strongly depends on the type of flake. The generation of crack branch occurred due to interaction of crack-nodule. The fractographs of the fatigue fracture surface for GC show cleavage plane along the flake graphite.
최근 해안, 도서, 산간지방 등의 개발로 장대교량의 수요가 증가되고 재료 및 설계 시공기술의 지속적 발전으로 인하여 현수교나 사장교 등 장지간을 가지는 교량의 건설이 증가하고 있다. 장대교량은 사장재 또는 주 케이블 및 행어로 주형을 지지하는 고차 부정정구조물로 다양한 형태의 설계가 가능하고 구조물의 외관이 뛰어나기 때문에 현재 많은 교량에 적용되고 있다. 케이블지지교량은 시공 중 그리고 공용상태에서 케이블의 장력을 지속적으로 측정함으로써 교량의 건전성을 파악할 수 있다. 케이블의 장력을 추정하는 기법으로 로드셀 및 유압잭 등을 이용하여 케이블의 응력을 직접 측정하는 방법과 케이블의 형상조건과 계측된 동적 특성을 활용하여 장력을 구하는 진동법이 많이 활용되고 있다. 본 연구에서는 디지털 영상처리를 이용한 행어케이블의 동특성 추정 방법을 제시하였으며 사용의 편의성과 경제성을 고려하여 원거리에 있는 행어케이블을 측정하기 위한 센서로 휴대용 디지털 캠코더를 사용하였다. 디지털 영상처리를 이용하는 방법은 digital image correlation(DIC) 기법을 사용하였으며 변형이 없는 이미지와 변형이 있는 이미지 사이의 기하학적인 왜곡을 보정하는 이미지 변환함수(ITF)를 사용하여 단위픽셀이하를 계산하였다. 또한 영상계측시스템의 흔들림을 추가적인 센서의 설치 없이 한 영상내의 고정된 물체를 이용하여 보정함으로써 행어케이블의 동적응답 및 모드별 고유진동수의 해상도를 향상시켰다.
인발법은 콘크리트 강도를 비파괴적으로 측정하는 방법으로 매우 신뢰할 만한 실험결과를 보여주고 구미에서는 규격화되고 표준화가 이루어져 있다. 하지만 시험방법이 복잡하고 시험기기가 고가이어서 국내에서는 사용이 전무한 실정이다. 이에 본 연구에서는 인발법이 현장에서 사용하기 쉽도록 시험방법을 간단히 하고 저렴하게 할 수 있도록 후매입 파단형 인발볼트를 이용한 인발시험법을 제안하였으며, 시험법에 필요한 후매입 파단형 인발볼트와 매입인발너트 고정방법, 인발시험기를 개발하였다. 특히 매입인발너트 고정방법으로는 임시고정용 볼트를 이용한 방법, 플라스틱 고정판을 이용한 방법, 고정막대를 이용한 고정방법을 제안하였다. 인발시험기는 유압실린더와 로드셀 등이 필요 없도록 기어를 이용하여 손잡이를 통한 회전력으로 인발시험이 가능하도록 고안하였다. 이 개발된 각각의 항목들은 직접 제작하고 현장에서 그 편리성과 정확성을 검토해 보았으며 검증실험도 실시하였다. 결과적으로 개발된 항목들은 추가적인 수정만 거치면 현장에서 유용하게 사용할 수 있으리라 판단된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.