• Title/Summary/Keyword: Hydraulic device

Search Result 259, Processing Time 0.037 seconds

Development of Hydraulic Device Performance Test Equipment Automation Process (유압 디바이스 성능 검사 장비 자동화 공정 개발)

  • Kim, Hong-Rok;Chung, Won-Jee;Seol, Sang-Seok;Park, Sang-Hyeok;Lee, Kyeong-Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.74-80
    • /
    • 2020
  • Crawler-type hydraulic devices facilitate forward and backward driving of construction equipment by converting power into mechanical energy. The existing hydraulic device performance test process is time- and labor-intensive. This study aims to improve efficiency and productivity by automating the hydraulic device production performance test processes, which have been separately conducted so far. We also used SolidWorksⓇ, a 3D modeling program, and ANSYSⓇ, a structural analysis tool, for structural analysis and to verify the suitability of fixing pins required for connecting a hydraulic device to performance test equipment. Our results that employing an automated hydraulic device performance test process improves efficiency.

Modeling and testing for hydraulic shock regarding a valve-less electro-hydraulic servo steering device for ships

  • Jian, Liao;Lin, He;Rongwu, Xu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.318-326
    • /
    • 2015
  • A valve-less electro-hydraulic servo steering device (short: VSSD) for ships was chosen as a study object, and its mathematic model of hydraulic shock was established on the basis of flow properties and force balance of each component. The influence of system structure parameters, changing rate of motor speed and external load on hydraulic shock strength was simulated by the method of numerical simulation. Experiment was designed to test the hydraulic shock mathematic model of VSSD. Experiment results verified the correctness of the model, and the model provided a correct theoretical method for the calculation and control of hydraulic shock of valve-less electro-hydraulic servo steering device.

A Study on the characteristics Torque and rpm for Varying Oil Quantity in Hydaultic Couplings (유체커플링의 작동유체량의 변화에 대한 토크와 회전수 특성에 관한연구)

  • 박용호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.241-247
    • /
    • 1998
  • The hydraulic coupling is a kind of power transmission device combined with pump turbine and casing as its main parts. The purpose of this research is to construct an experimental test set-up and to establish an available soft ware for th characteristics of two domestically developed hydraulic couplings. The test item is torgue rpm. and slip and or efficiency characteristic in accordance with variation of oil quantity. in this case the oil quantity was varied 55%, 67% and 77% of the inside capacity of hydraulic copuling.

  • PDF

Study on Performance Improvement of an Axial Flow Hydraulic Turbine with a Collection Device

  • Nishi, Yasuyuki;Inagaki, Terumi;Li, Yanrong;Hirama, Sou;Kikuchi, Norio
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 2016
  • The portable hydraulic turbine we previously developed for open channels comprises an axial flow runner with an appended collection device and a diffuser section. The output power of this hydraulic turbine was improved by catching and accelerating an open-channel water flow using the kinetic energy of the water. This study aimed to further improve the performance of the hydraulic turbine. Using numerical analysis, we examined the performances and flow fields of a single runner and a composite body consisting of the runner and collection device by varying the airfoil and number of blades. Consequently, the maximum values of input power coefficient of the Runner D composite body with two blades (which adopts the MEL031 airfoil and alters the blade angle) are equivalent to those of the composite body with two blades (MEL021 airfoil). We found that the Runner D composite body has the highest turbine efficiency and thus the largest power coefficient. Furthermore, the performance of the Runner D composite body calculated from the numerical analysis was verified experimentally in an open-channel water flow test.

Modeling & Simulation of a Hydraulic Servo Actuator Cushion for Power Plants (발전소용 유압 서보액추에이터의 쿠션 모델링 및 시뮬레이션)

  • Lee, YongBum;Yoon, Young Hwan
    • Tribology and Lubricants
    • /
    • v.29 no.1
    • /
    • pp.7-12
    • /
    • 2013
  • Turbine power control devices at a nuclear / thermoelectric power plant lead to failure by creating mechanical shocks and strong vibrations that are due to the strong elasticity of a spring and the inertia of the valve face during its rapid movement to block steam. To ensure durability of the turbine power control device, which is the main component in the power plant, it is necessary to develop a device that can prevent such vibrations. In this study, a cushion mechanism is added to the head of the hydraulic servo actuator, which is a turbine power control device. Moreover, the cushion mechanism, which includes various modifies shapes and orifices is investigated dynamically through modeling and simulations.

Using a Borehole Stability Device for Hydraulic Testing in Unconsolidated Alluvium (공벽 유지장치를 이용한 미고결 충적층의 수리특성 평가)

  • Won, Kyoung-Sik;Kim, Chunsoo;Chae, Soo-Yong;Shin, Dong-Min
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.15-22
    • /
    • 2016
  • Hydraulic falling head and slug tests were carried out in an alluvium aquifer using a borehole stability device. The hydraulic testing had proved difficult in alluvial formations of sands and gravels due to borehole collapse and unstable borehole walls within the test section. This study aims to improve the hydraulic test results by using a borehole stability device. The device can minimize the collapse of borehole walls, and the use of a filter with a constant opening ratio improves the calculations per unit area of the test section. Permeability obtained from the falling head test without a borehole stability device was 8.82 × 10−5m/sec. When the borehole stability device was installed in the same test section the measured permeability increased to 4.00 × 10−4m/sec, which is 4.5 times that obtained without the borehole device. The relatively low permeability obtained using the conventional test method is attributed to the presence of a fine-grained slime generated during drilling and a reduction of the test area in the test interval due to a gradual collapse of the borehole walls. This study considers how the use of a borehole stability device to prevent borehole collapse can influence the results of hydraulic tests in alluvial formations. It is expected that the results can be used as a basis for improving the reliability and applicability of hydraulic tests performed in alluvial aquifers.

A Study on Pick-up Device of Beep Sea Manganese Nodules Collector (심해저 망간단괴 집광기의 채집장치에 관한 연구)

  • Hong, Sub;Sim, Jae-Yong;Lee, Tae-Hee;Choi, Jong-Soo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.891-895
    • /
    • 1996
  • Performance and efficiency of hybrid (hydraulic-mechanical) pick-up device of deep sea manganese nodules collector are very sensitive to altitude and altitude of pick-up head relative to undulating seafloor. For this reason, motion control of pick-up head relative to the changing deep sea topography and other disturbances is of particular importance in design of pick-up device. The concept of design axiom is applied to a pick-up device of hybrid type. Kinematic analysis conducted in absolute Cartesian coordinates gives position, velocity, and acceleration of the hydraulic cylinders which enable the pick-up head to keep the preset optimal distance from seafloor. Inverse dynamic analysis provides the driving forces of hydraulic cylinders and the reaction forces at each joint. Design sensitivity analysis is performed in order to investigate the effects of possible design variables on the change of the maximum strokes of hydraulic cylinders. The direct differentiation method is used to obtain the design sensitivity coefficients.

  • PDF

A Study on a Configuration of the Load Characteristic Evaluation Device Using Hydraulic Power for the Analysis of the Tilting Kinetic Mechanism (틸팅 부하메커니즘 특성 분석을 위한 유압식 부하특성 평가 장치구성에 대한 연구)

  • Lee, Jun-Ho;Kim, Ho-Yeon;Han, Seong-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1152-1158
    • /
    • 2011
  • In this paper a configuration of the load evaluation device for the tilting actuator using hydraulic power is presented, which makes it possible to measure the force action on the tilting actuator. It is possible to measure only current using the conventional electro-mechanical actuator when the bogie is in the process of the tilting. This makes impossible to measure the force acting on the tilting actuator. In order to overcome this problem a kinetic mechanism test system using hydraulic cylinder is proposed. The system are consisted of hydraulic cylinder for the tilting actuation, control system to control hydraulic power, sensors to measure for force and displacement and monitoring system for the user interface.

A Study of the Variation in Intensifier Performance Characteristics Varying with Pressure and Temperature (압력·온도 변화에 따른 초고압 발생기 성능특성 연구)

  • Kim, Hyoung-Eui;Lee, Gi-Chun;Kim, Jae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1249-1255
    • /
    • 2010
  • An ultra high- pressure system generally consists of a hydraulic power unit, an oil supply unit, an electrical power supply device, and an electrical control device. The hydraulic power unit supplies the hydraulic power to the intensifier to create generate ultra high pressure. The intensifier amplifies increases the pressure using the oil supplied from by the hydraulic power unit. The electrical supply devices and control devices maintain are provided for the electric motors, valves, and sensors. In this study, instead of a flow-control device, a pressure-control type device was mounted on a manifold block in the hydraulic power unit instead of the flow-control type. A servo valve was fitted in the intensifier, and the performance characteristics of the intensifier varied according to the variations of in the pressure cycle and with the temperature of the operating oil in the hydraulic power unit.

A Study on the Hydraulic Fall Prevention Device (유압식 추락 방지장치에 관한 연구)

  • Choi, Jung-Hun;Koo, Jae-Mean;Seok, Chang-Sung;Huh, Yong;Chang, Sung-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.78-83
    • /
    • 2010
  • Since a tower crane is too high for a worker to ascend and by the wind in the high altitude, the possibility of a safety accident is very high, a lift assist is used. In this study, the hydraulic fall prevention device using the pressure generation device by Seok, et al. was developed. For this, the effects on the fall prevention performances of factors such as gear clearance, oil viscosity, rotative velocity and so on were evaluated by the analysis of fluid flow using FEM and the prototype was producted and a function test was performed.