• 제목/요약/키워드: Hydraulic conductivity (K)

검색결과 414건 처리시간 0.035초

A Study on the Effective Hydraulic Conductivity of an Anisotropic Porous Medium

  • Seong, Kwanjae
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.959-965
    • /
    • 2002
  • Effective hydraulic conductivity of a statistically anisotropic heterogeneous medium is obtained for steady two-dimensional flows employing stochastic analysis. Flow equations are solved up to second order and the effective conductivity is obtained in a semi-analytic form depending only on the spatial correlation function and the anisotropy ratio of the hydraulic conductivity field, hence becoming a true intrinsic property independent of the flow field. Results are obtained using a statistically anisotropic Gaussian correlation function where the anisotropy is defined as the ratio of integral scales normal and parallel to the mean flow direction. Second order results indicate that the effective conductivity of an anisotropic medium is greater than that of an isotropic one when the anisotropy ratio is less than one and vice versa. It is also found that the effective conductivity has upper and lower bounds of the arithmetic and the harmonic mean conductivities.

고준위방사성폐기물 처분시스템의 압축 벤토나이트 완충재의 포화 수리전도도 추정 (A Prediction of Saturated Hydraulic Conductivity for Compacted Bentonite Buffer in a High-level Radioactive Waste Disposal System)

  • 박승훈;윤석;권상기;김건영
    • 방사성폐기물학회지
    • /
    • 제18권2호
    • /
    • pp.133-141
    • /
    • 2020
  • 고준위방사성폐기물의 처분은 고심도 암반내에 처분시스템을 구축하는 심층 처분방법이 고려된다. 심층 처분은 처분용기, 완충재, 뒷채움재, 근계암반의 설계 요소인 공학적방벽과 천연 방벽으로 구성된다. 공학적방벽 중에서 벤토나이트 완충재는 암반으로부터 유입되는 지하수 흐름을 최소화하고 핵종 유출을 저지하는 기능을 한다. 지하수 유입으로 인한 완충재의 수리전도도 특성 규명은 처분장 공학적방벽의 안정성 및 건전성에 대한 성능 평가에 있어 중요한 사안이다. 본 연구에서는 경주 벤토나이트를 이용하여 다양한 건조밀도와 온도 조건에 따라 포화 수리전도도 실험을 수행하였으며, 120개의 실험 결과를 다중 회귀 분석을 통해 수리전도도 추정 모델을 제시하였다. 실험 결과에서는 건조밀도가 커질수록 수리전도도가 감소하는 경향이 나타났다. 또한, 온도가 증가할수록 수리전도도가 증가하였다. 이러한 실험 결과들을 종합한 다중 회귀 분석 결과에서는 수리전도도 추정식의 결정계수(R2)가 0.93으로 높게 나타났다. 본 연구에서 제시된 수리전도도 추정식은 벤토나이트 완충재의 성능과 연관된 건조밀도와 온도의 영향을 고려하여 처분시스템의 공학적방벽 설계에 활용 될 것으로 판단된다.

Changes in plant hydraulic conductivity in response to water deficit

  • Kim, Yangmin X.;Sung, Jwakyung;Lee, Yejin;Lee, Seulbi;Lee, Deogbae
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.35-35
    • /
    • 2017
  • How do plants take up water from soils especially when water is scarce in soils? Plants have a strategy to respond to water deficit to manage water necessary for their survival and growth. Plants regulate water transport inside them. Water flows inside the plant via (i) apoplastic pathway including xylem vessel and cell wall and (ii) cell-to-cell pathway including water channels sitting in cell membrane (aquaporins). Water transport across the root and leaf is explained by a composite transport model including those pathways. Modification of the components in those pathways to change their hydraulic conductivity can regulate water uptake and management. Apoplastic barrier is modified by producing Casparian band and suberin lamellae. These structures contain suberin known to be hydrophobic. Barley roots with more suberin content from the apoplast showed lower root hydraulic conductivity. Root hydraulic conductivity was measured by a root pressure probe. Plant root builds apoplastic barrier to prevent water loss into dry soil. Water transport in plant is also regulated in the cell-to-cell pathway via aquaporin, which has received a great attention after its discovery in early 1990s. Aquaporins in plants are known to open or close to regulate water transport in response to biotic and/or abiotic stresses including water deficit. Aquaporins in a corn leaf were opened by illumination in the beginning, however, closed in response to the following leaf water potential decrease. The evidence was provided by cell hydraulic conductivity measurement using a cell pressure probe. Changing the hydraulic conductivity of plant organ such as root and leaf has an impact not only on the speed of water transport across the plant but also on the water potential inside the plant, which means plant water uptake pattern from soil could be differentiated. This was demonstrated by a computer simulation with 3-D root structure having root hydraulic conductivity information and soil. The model study indicated that the root hydraulic conductivity plays an important role to determine the water uptake from soil with suboptimal water, although soil hydraulic conductivity also interplayed.

  • PDF

Estimating coefficient of consolidation and hydraulic conductivity from piezocone test results - Case studies

  • Hossain, Md. Julfikar;Chai, Jinchun
    • Geomechanics and Engineering
    • /
    • 제6권6호
    • /
    • pp.577-592
    • /
    • 2014
  • The methods for estimating in-situ hydraulic conductivity ($k_{hp}$) and coefficient of consolidation ($c_{hp}$) in the horizontal direction from piezocone penetration and dissipation test results have been investigated using test results at two sites in Saga, Japan. At the two sites the laboratory values of hydraulic conductivity ($k_v$) and coefficient of consolidation ($c_v$) in the vertical direction are also available. Comparing $k_{hp}$ with $k_v$ and $c_{hp}$ with $k_v$ values, suitable methods for estimating $k_{hp}$ and $c_{hp}$ values are recommended. For the two sites, where $k_{hp}{\approx}k_v$ and $c_{hp}{\approx}2c_v$. It is suggested that the estimated values of $k_{hp}$ and $c_{hp}$ can be used in engineering design.

상대습도를 이용한 벤토나이트 완충재의 불포화 수리전도도 평가방안 (The Method for Evaluating Unsaturated Hydraulic Conductivity of the Bentonite-buffer Using Relative Humidity)

  • 이항복;김진섭;최영철;최희주;김경수
    • 방사성폐기물학회지
    • /
    • 제12권1호
    • /
    • pp.69-77
    • /
    • 2014
  • 상대습도 데이터를 이용하여 벤토나이트 완충재 블록의 불포화 수리전도도 변화를 평가하였다. 불포화 매질에서의 물의 흐름을 나타내는 일반적인 분석해를 통해 상대습도를 통한 불포화 수리전도도 계산방안을 도출하였고, 이를 실제 수행한 실내 물 유입 실험 결과에 적용하여 포화가 진행됨에 따라 변화하는 완충재 불포화 수리전도도 양상을 확인하였다. 일반적인 포화 상태와는 확연히 다르게 수두 구배와 물의 유출량이 시간에 따라 불규칙하게 변화하는 결과를 나타냈으며, 벤토나이트 완충재의 불포화 수리전도도는 시간에 따라 증가하는 경향을 보였다. 수분 흡수로 인한 벤토나이트 입자 팽창 때문으로 인한 매질 내 공극의 부피 및 크기 확대가 불포화 수리전도도값의 증가를 야기하는 것으로 판단되었고, 이러한 결과는 완충재 블록의 팽창 정도와 수리전도도의 상관성에 관한 추후 연구의 필요성을 제시하였다. 본 연구에서 수행된 불포화 수리전도도 평가 방안은 방사성폐기물 처분 시 완충재의 장기적인 수리학적 성능평가에 유용한 기술로 사용될 수 있을 것이다.

제주도 대정유역의 수리전도도 적용에 따른 지하수 모델링 결과 평가 (Assessment of Groundwater Flow Modeling according to Hydraulic Conductivity Zonation in the Dae-jeong Watershed of Jeju Island)

  • 박재규;김민철;양성기;이준호;김용석
    • 한국환경과학회지
    • /
    • 제25권12호
    • /
    • pp.1727-1738
    • /
    • 2016
  • In this study, groundwater flow was analyzed targeting Dae-jeong watershed, which exhibited the largest variations of groundwater levels at the identical elevation points among the 16 watersheds of Jeju Island. The issues of the methods applied in practice were identified and improvement plans were suggested. This groundwater-flow estimates derived by applying hydraulic conductivity values onto zones of equal topographic ground level were found to be quite different from actual measured groundwater flow. Conversely, groundwater-flow estimates that utilized hydraulic conductivity values applied onto groundwater-level equipotential lines indicated relatively lesser divergences from actual measured groundwater flow. The reliabilities of the two approaches were assessed for 60 randomly selected points on DEM (digital elevation model) maps, The method using hydraulic conductivity values applied onto groundwater-level contours turned out to be the more reliable approach for the Dae-jeong watershed in Jeju Island.

방사형집수정의 수평집수관에서 지질특성과 취수량의 상관관계 분석 (Analysis of the Correlation between Geological Characteristics and Water Withdrawals in the Laterals of Radial Collector Well)

  • 김태형;정재훈;김민;오세형;이재성
    • 지질공학
    • /
    • 제24권2호
    • /
    • pp.201-215
    • /
    • 2014
  • 본 연구에서는 창원시 강변여과수 개발사업(2단계)에서 얻어진 자료들을 이용하여 대수층의 수리전도도와 방사형집수정의 수평집수관에서 산출되는 유량과의 상관관계를 규명하고자 하였다. 연구지역인 낙동강 중하류 모래자갈층에서 수평적으로 채취한 미고결 퇴적물의 시료를 이용하여 경험식에 의한 수리전도도를 산정하였다. 여러 경험식을 이용하여 연구지역에서 수리전도도를 산정한 결과, Beyer식에 의한 수리전도도가 가장 적합한 것으로 판정되었다. 산정된 수리전도도는 0.083 ~ 0.264 cm/s의 범위, 평균 0.159 cm/s로 나타내고 있어 연구지역의 대수층 특성은 모래자갈층에 투수성이 양호한 것으로 나타났다. 산정된 수리전도도와 실측자료에 의한 스크린 내 지하수의 유입속도 및 유량과의 상관관계를 분석하고자 회귀분석을 실시하였다. 회귀분석 결과, 수리전도도와 지하수의 유입속도 및 유량은 약 72 %의 높은 상관관계를 가지는 것으로 나타났고, 각 변수들 간에 실측자료와의 검증에서도 약 72 %가 일치하는 것으로 분석되어 선형 회귀식은 높은 적합성을 나타내었다. 본 연구의 결과로서 선형 회귀식을 이용하여 수리전도도에 의한 방사형집수정의 수평집수관에서 산출되는 유량의 추정이 가능하고, 연구지역과 유사한 대수층에서 적용이 가능할 것이라고 사료된다.

AN ANALYSIS OF THE FACTORS AFFECTING THE HYDRAULIC CONDUCTIVITY AND SWELLING PRESSURE OF KYUNGJU CA-BENTONITE FOR USE AS A CLAY-BASED SEALING MATERIAL FOR A HIGH-LEVEL WASTE REPOSITORY

  • Cho, Won-Jin;Lee, Jae-Owan;Kwon, Sang-Ki
    • Nuclear Engineering and Technology
    • /
    • 제44권1호
    • /
    • pp.89-102
    • /
    • 2012
  • The buffer and backfill are important components of the engineered barrier system in a high-level waste repository, which should be constructed in a hard rock formation at a depth of several hundred meters below the ground surface. The primary function of the buffer and backfill is to seal the underground excavation as a preferred flow path for radionuclide migration from the deposited high-level waste. This study investigates the hydraulic conductivity and swelling pressure of Kyungju Ca-bentonite, which is the candidate material for the buffer and backfill in the Korean reference high-level waste disposal system. The factors that influence the hydraulic conductivity and swelling pressure of the buffer and backfill are analyzed. The factors considered are the dry density, the temperature, the sand content, the salinity and the organic carbon content. The possibility of deterioration in the sealing performance of the buffer and backfill is also assessed.

Hydraulic architecture를 이용한 참나무속 주요 수종의 수분 특성 분석 (Analysis of Water Relations of Economic Oak Species by Hydraulic Architecture Method)

  • 권기원;최정호;김선아
    • 농업과학연구
    • /
    • 제23권1호
    • /
    • pp.108-119
    • /
    • 1996
  • 낙엽성 참나무류 6종의 당년생 가지에 대해 목부를 구성하는 도관의 수분 통도성에 관련된 몇 가지 모수들이 조사되었다. 또한 신갈나무와 굴참나무 맹아 및 신갈나무와 상수리나무의 실생묘를 대상으로 상기 수분 통도와 관련된 모수들을 조사하였다. specific conductivity와 leaf specific conductivity 그리고 도관의 직경과 관련을 지닌 것으로 간주되는 Hagen-Poiseuille's relative hydraulic conductivity의 측정치 들은 조사된 모든 수종 중 떡갈나무에서 가장 높은 값을 보였다. 조사된 대부분의 수종에 있어서 5-6월에 측정된 상기 측정치 들은 생육기의 경과와 함께 cavitation 등에 의해 도관 폐색이 증대되는 9-10월의 측정치보다 높은 값을 보였다. Hagen-Poiseuille의 경험식에 의해 추정된 도관의 relative hydraulic conductivity와 실측한 hydraulic conductivity 간에는 대부분의 수종에서 정의 상관 관계를 보였다. 잎의 면적 또는 건중량 각각을 기준으로 하는 Huber value와 leaf specific conductivity 간에는 일부 예외가 있지만 전체적으로 서로 비슷한 양상을 나타냈다. 신갈나무와 굴참나무에서 맹아지의 수분 통도성은 정상지보다 양호한 것으로 나타났다. 신갈나무와 상수리나무의 실생묘에 있어서 가지를 절단한 직후에 측정된 specific conductivity와 leaf specific conductivity는 그 후 cavitation에 의한 도관 폐색으로 급격히 낮아지는 현상을 보였다. 신갈나무와 상수리나무 실생묘에서 측정된 수분 통도 기능의 일중 변화를 고려할 때 약한 수분 stress 하에서는 수목이 능동적인 수분 흡수를 통해 그들의 수분 통도성을 자체 회복할 수 있음을 보여주었다. 주기적으로 수분 stress를 받는 상수리나무 실생묘의 specific conductivity와 leaf specific conductivity 등은 생육 기간이 경과되면서 감소되었지만 통도성에 미치는 수분 stress의 영향은 이와 관련을 지닌 목부 및 잎의 발달에 동시에 비슷한 방향으로 작용하고 있어 분명한 결론을 얻기 어려웠다. 이들 묘목에서 수분 통도성에 대한 측정치들은 일반적으로 근원부보다 줄기의 중간 또는 상부에서 더 높은 값을 나타내었다.

  • PDF

Infiltration characteristics and hydraulic conductivity of weathered unsaturated soils

  • Song, Young-Suk;Hong, Seongwon
    • Geomechanics and Engineering
    • /
    • 제22권2호
    • /
    • pp.153-163
    • /
    • 2020
  • Laboratory experiments were conducted with two different soil conditions to investigate rainfall infiltration characteristics. The soil layer materials that were tested were weathered granite soil and weathered gneiss soil. Artificial rainfall of 80 mm/hr was reproduced through the use of a rainfall device, and the volumetric water content and matric suction were measured. In the case of the granite soil, the saturation velocity and the moving direction of the wetting front were fast and upward, respectively, whereas in the case of the weathered gneiss soil, the velocity and direction were slow and downward, respectively. Rainfall penetrated and saturated from the bottom to the top as the hydraulic conductivity of the granite soil was higher than the infiltration capacity of the artificial rainfall. In contrast, as the hydraulic conductivity of the gneiss soil was lower than the infiltration capacity of the rainfall, ponding occurred on the surface: part of the rainfall first infiltrated, with the remaining rainfall subsequently flowing out. The unsaturated hydraulic conductivity function of weathered soils was determined and analyzed with matric suction and the effective degree of saturation.