• 제목/요약/키워드: Hydraulic System Efficiency Analysis

검색결과 105건 처리시간 0.028초

전력설비 대용량 보일러 통풍기 날개각 제어 작동기 모델링 (Modelling of Power Plant Fan Pitch Blade Control Actuator)

  • 허준영;손태하
    • 유공압시스템학회논문집
    • /
    • 제4권2호
    • /
    • pp.28-33
    • /
    • 2007
  • In the power plant facility which use soft coal as a power source the fan pitch blade control hydraulic actuator is used to control the inlet and outlet gas to regulate the internal pressure of the furnace and control the frequence. Sometimes malfunctions of this equipment lead to the decline of boiler thermal efficiency and unexpected power plant trip. In order to localize the fan pitch blade control hydraulic actuator specially for the 500MW large scale boiler, Analysis and modelling of the system is carried out mathematically. The responses of the system are examined by using matlab simulation fur the variation of the major parameters in view of reverse engineering. Consequently the validity of the established parameters are examined.

  • PDF

Numerical Analysis Dynamometer (Water Brake) Using Computational Fluid Dynamic Software

  • 최광환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.103-111
    • /
    • 2008
  • One of the most popular internal combustion engines is the engine in the transportation device. Power is a parameter that shows the capabilities of an object that gives energy, for example the internal combustion engine. Power in this engine is measured by a device called dynamometer. The CFD (Computational Fluid Dynamic) fluent software was simulated several impeller variables to absorb power of engine. With that result, we knew the biggest dynamometer absorber power, cheapest and easy to be made. The hydraulic dynamometer is selected type of dynamometer as the result of design process. The basic principle of a hydraulic dynamometer is the same as centrifugal pump but it has low pump efficiency. The results of the test are maximum power and torque of the tested engine and the operation area of the selected hydraulic dynamometer.

  • PDF

3-way형과 Bypass형 서보유압 피에조 인젝터의 구동특성 비교 (Comparison Analysis of Dynamic Characteristics of Servo-hydraulic Piezo-driven Injector between 3-way and Bypass-circuit Type)

  • 조인수;정명철;이진욱
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.169-175
    • /
    • 2013
  • CRDi technology of diesel engine was developed from in the early 2000s due to a need to increase fuel efficiency and environment care. Especially, high-pressure fuel injection system in CRDi system which has a fuel injection unit including an injector, a fuel pump and common-rail, etc. becomes possible to make the exhaust gas clean as well as power improvement. In this study, comparison of dynamic characteristics of servo-hydraulic piezo-driven injector with 3-way and bypass-circuit type was analyzed by using the AMESim code. As results of this study, it found the bypass-circuit inside servo-hydraulic piezo injector can cause a faster injection response than that of the 3-way type. Also it was shown that bypass-circuit type had better control capability due to hydraulic bypass system.

초대형 굴삭기용 유압펌프 구동 기어박스의 수명시험에 관한 연구 (A Study of the Life Test of Hydraulic Pump Driving Gear Box for the Large Excavator)

  • 이용범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권3호
    • /
    • pp.211-216
    • /
    • 2015
  • 차체중량이 90 ton인 초대형 유압굴삭기에서는 유압시스템의 효율향상을 통한 연비개선을 위해서 유압펌프 구동용 기어박스(hydraulic pump driving gear box)를 사용하여 다수(3~6개)의 펌프를 병렬로 장착하여 사용한다. 펌프 구동 기어 박스는 굴삭기의 대형엔진과 연결되는 입력 축 1개로 기계적 동력인 회전수와 토크를 공급받아 고압펌프와 저압펌프에서로 다른 기계적 출력을 공급하게 된다. 따라서 펌프 구동 기어박스는 굴삭기의 대동맥과 같으며, 엔진이 가동되는 시간동안 지속적으로 펌프를 구동함으로서 장 수명이 요구된다. 본 연구에서는 큰 시험동력(600kw)이 요구되는 수명평가에서 에너지절감을 위한 전기 회생식 시험 장비를 구축하여 높은 에너지 절감과 수명시험을 수행하면서 기어박스의 마모 특성을 분석하는 방법으로 윤활유 오염 입자 분석과 기어파손 유무를 검증하는 방법으로 진동분석 방법을 사용하였다.

지하수 유동 영향에 따른 지하수 이용 열펌프 시스템의 대수층 온도 변화 예측 모델링 (Simulation of aquifer temperature variation in a groundwater source heat pump system with the effect of groundwater flow)

  • 심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.701-704
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having influenced by groundwater movement, understanding of thermo hydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.00 1 are shaped circular, and the center is moved less than 5m to the groundwater flow direction in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

RF 방사 신호 차폐를 통한 비상 유압경고등의 비정상 점등 현상의 원인분석 및 개선 (Analysis and Improvement of False Alarm Phenomenon of Emergency Hydraulic Warning Light by Shielded RF Radiation Signal)

  • 권정혁;김경남;전병권;이왕상
    • 항공우주시스템공학회지
    • /
    • 제17권1호
    • /
    • pp.68-78
    • /
    • 2023
  • 본 논문에서는 항공기 내의 RF 방사 신호로 인하여 비상 유압 경고등이 비정상으로 점등되는 현상에 대한 개선 방안을 연구하였다. RF 방사 신호의 전자파 간섭으로 비행 중에 비상 유압 시스템의 경고등이 점등되면, 비행 임무 및 안전에 영향을 주어 비행 임무의 효율 저해 및 정비 소요가 발생한다. 따라서, 비상 유압 경고등의 비정상 점등에 대해서 원인 분석 및 고장탐구를 수행하였다. RF 방사 신호의 경로에 있는 항공기의 동체 하부 복합체 스트립을 차폐하여 비상유입지시계로 유입되는 RF 방사 신호를 차단하도록 개선하였다. 또한, 지상과 비행 모니터링을 통해 개선 방안을 적용한 결과도 함께 기술하였다.

비접촉식 와전류형 제동 장치의 최적 토오크 제어 (Optimal torque control of noncontact type eddy current brake system)

  • 이갑진;박기환;류제하
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.261-264
    • /
    • 1997
  • A contactless eddy current type braking system is developed to take advantages of the recent brake system which uses hydraulic force can show high efficiency in a certain velocity region, but not in a high velocity region, and has initial response delay time and pressure build-up time which make stopping distance longer. These are the limits of mechanical brake system of a contact type, which makes a concept brake system required. So, in this paper, the contactless brake system .of a inductive current type is chosen instead of hydraulic brake system. This brake system can be used almost forever for being no wear and contributed to lightening weight of a vehicle. Besides, the contactless brake system can be used as that of electric or solar car with anti-lock brake system. The analysis of induced electromotive force and braking torque obtained with theoretical approximate model, the design of a braking system and a nonlinear controller, and the results of simulation of the ABS, experiment are included.

  • PDF

개선된 여과형 시설의 비점오염물질 처리효율 평가 (Treatment Efficiency of Non-Point Source Pollutants Using Modified Filtration System)

  • 강희만;최지연;김이형;배우근
    • 한국습지학회지
    • /
    • 제13권2호
    • /
    • pp.161-169
    • /
    • 2011
  • 본 연구는 여과와 침투기작을 이용한 개선된 여과형 시설의 비점오염물질 처리효율을 평가하고자 수행되었다. 저감시설은 지리학적 기후학적인 인자를 고려하여 기존의 저감시설의 단점을 보완하여 설계되었다. 저감시설의 처리효율 평가는 실험실 규모로 수행되었으며, 3가지 유형의 유속[초기강우(120 mL/min), 일반적인 강우(242 mL/min), 집중호우(500 mL/min)]을 적용하여 실험을 진행하였고, 이를 통하여 수질 분석 및 물수지를 산정하였다. 실험결과, 저감시설의 입자상 물질 제거 효율은 90%이상으로 높게 분석되었다. 3가지의 유속변화 실험 중, 집중호우의 경우에서 11~91% 범위로 낮은 제거효율을 보였는데, 이는 다른 유속에 비해 짧은 체류시간을 갖기 때문으로 판단된다. 또한 저감시설의 물수지 산정결과 침투량은 유출량의 약 1%에 불과하여 향후 저감시설 설계 시, 침투를 증가시키기 위해서 시설하부의 토양치환 등을 통한 침투량 및 저류량을 증가시킬 수 있는 기술적 접근이 필요하며, 이는 오염물질의 저감에 크게 기여할 것으로 판단된다.

체크밸브 특성이 소형 압전유압펌프 유량에 미치는 효과 (Effect of Check Valve Characteristics on Flow Rate of the Small Piezoelectric-Hydraulic Pump)

  • 응위웬 안 푹;황재혁;황용하;배재성
    • 항공우주시스템공학회지
    • /
    • 제12권5호
    • /
    • pp.54-68
    • /
    • 2018
  • 본 논문에서는 소형 압전유압펌프에 적용된 체크밸브의 동적 특성이 유량 형성에 미치는 효과에 대한 연구를 수행하였다. 브레이크 시스템 작동을 위한 부하 압력의 형성을 위해서는 압전유압펌프의 유량이 중요한 요소이다. 이때, 유체 내에서 작동하는 체크밸브의 고유 진동수는 압전 유압펌프의 유량 형성에 큰 영향을 미친다. 또한, 체크밸브의 고유 진동수는 체크밸브와 펌프 시트 사이의 간격에 영향을 받는다. 이를 고려하여 본 연구에서는 체크밸브와 펌프 시트 사이의 간격에 따른 체크밸브의 고유진동수를 유체-구조 연성 해석을 통해 산출하였다. 시뮬레이션을 통해 얻은 유량은 개발된 압전유압펌프를 이용한 유량 형성 실험과의 비교를 통해 검증하였다.

2.5 kW 급 프로펠러형 마이크로 수차 개발 (Development of 2.5 kW Class Propeller Type Micro Hydraulic Turbine)

  • 마상범;김성;최영석;차동안;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제31권3호
    • /
    • pp.314-321
    • /
    • 2020
  • In this work, a preliminary design of an inlet guide vane and runner for developing a 2.5 kW hydraulic turbine was conducted by using computational fluid dynamic analysis. Three-dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model were used to analyze the fluid flow in the hydraulic turbine. The hexahedral grid system was used to construct computational domain, and the grid dependency test was performed to obtain the optimal grid system. Velocity triangle diagram considering the flow angles of the inlet guide vane and runner was analyzed to obtain a basic geometry of the inlet guide vane and runner. Through modification of the preliminary design, the hydraulic performances of the turbine have improved under overall drop conditions. Especially, the efficiency and power of the turbine increased by 0.95% and 1.45%, respectively, compared to those of the reference model.