• Title/Summary/Keyword: Hybrid type

Search Result 1,834, Processing Time 0.035 seconds

Design of MLC chip quadrature hybrid for 2 GHz band mobile communications (2 GHz대 이동 통신용 MLC 칩 90$^{\circ}$ 하이브리드 설계)

  • 심성훈;강종윤;윤석진;신현용;윤영중;김현재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.115-118
    • /
    • 2002
  • This paper presents the design method and performance characteristics of a chip-type quadrature hybrid using LTCC-MLC technology. The design method for a chip-type quadrature hybrid is based on lumped element equivalent circuit of quarter-wave transformer. The chip-type quadrature hybrid was miniaturized to a greater extent using multilayer structure and lumped element. The proposed design method can also reduce the undesirable parasitic effects of the chip-type quadrature hybrid. The proposed chip-type quadrature hybrid was designed and fabricated using the proposed design method and the equivalent circuit model of a quarter-wave transformer. Fabrication and measurement of designed chip-type quadrature hybrid show much smaller size than a conventional distributed quadrature hybrid and a good agreement with simulated results.

  • PDF

Environmental Friendly Construction Process of Composite Beam and its Application (친환경 층고 절감형 합성보의 시공 Process 및 시공사례)

  • Hong, Won-Kee;Park, Seon-Chee;Lee, Kyoung-Hun;Kim, Jeom-Han;Lee, Ho-Chan;Hwang, Yun-Ha
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.107-112
    • /
    • 2007
  • Recently hybrid beam system is widely used because it has many structural advantages such as short construction period and low story height etc. Generally steel wide flange beam exposure type and embedded type hybrid beams are constructed. Even though exposure hybrid beam is easily constructed, the fire proofing protection process is necessary because steel wide flange beam cannot resist to fire itself. Story height reduction type hybrid beam, which is introduced hybrid beam in this paper, does not need fire proofing protection process because it is constructed as a fully embedded type hybrid beam. Developed construction process and actual construction cases of story height reduction type hybrid beam were introduced in this study.

Characteristics of fuel economy and emissions of soft and hard type hybrid vehicles (소프트 타입과 하드타입 하이브리드자동차의 연비 및 배출가스 특성에 관한 연구)

  • Kim, Jong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4283-4287
    • /
    • 2011
  • This paper describes the characteristics of emissions and fuel economy of soft type hybrid vehicle (Hyundai Avante) and hard type hybrid vehicle(Toyoda, Prius) in a transient CVS-75 driving mode. Hybrid vehicles showed the better fuel economy and emission characteristics comparing the conventional gasoline vehicle. Especially, hard type hybrid vehicle showed the better fuel economy comparing soft type hybrid vehicle under 55 km/h periods in the CVS-75 mode.

Performance Analysis of Type-I Hybrid ARQ System Considering Transmission Delay Time (전송 지연시간을 고려한 Type-I Hybrid ARQ 시스템의 성능 분석)

  • 조치원;유흥균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.879-888
    • /
    • 1999
  • A Study on the ARQ scheme of data error control is important for more reliable information transmission. Since performance difference is large by the long transmission delay time in satellite communication, the performances of SR ARQ and conventional type-I hybrid ARQ with fixed code rate are investigated by using the parameters of packet length, channel capacity, BER, and transmission delay time especially. BCH code is used in type-I hybrid ARQ for FEC method. This paper presents the throughput analyses according to such various parameters as BCH code rate, window size, data rate and round-trip delay time. Especially we derive a performance equation of type-I hybrid ARQ with the factor of the transmission delay time using the equation of SAW ARQ. Also, the performance of type-I hybrid ARQ specially considering transmission delay time is analyzed through numerical analysis and computer simulation so we can get a important characteristics variation.

  • PDF

Comparative Study of Current Limiting Characteristics for Hybrid Type and Flux-Lock Type SFCLs

  • Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.222-225
    • /
    • 2007
  • In this paper, we compared the current limiting characteristics of both the hybrid type and the flux-lock type superconducting fault current limiters(SFCLs), which have a magnetic coupling structure between a primary winding and several secondary windings. The limiting impedances of two SFCLs were derived from each equivalent circuit considering the design parameters of SFCL such as the self-inductance of secondary winding and the resistance of $high-T_C$ superconducting(HTSC) element. Through the comparison for the limiting impedances of two SFCLs considering the dependence of the HTSC element's resistance on the applying voltage into the SFCL, the hybrid type SFCL was confirmed to have larger limiting impedance with smaller resistance of HTSC element than the flux-lock type SFCL. It was expected from the analysis that the hybrid type SFCL was more advantageous than the flux-lock type SFCL from the viewpoint of the fault current limiting level.

Interruption Capability of Hybrid Type GCB with High Opening Speed (고속도 개극 시의 복합소호 가스차단기의 차단특성)

  • Song Ki-Dong;Chong Jin-Kyo;Park Kyong-Yop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.9
    • /
    • pp.408-413
    • /
    • 2005
  • This paper presents the basic design technology on the hybrid type GCB(gas circuit breakers) through the test results. The three type hybrid interrupters according to the arrangement of the thermal expansion chamber and the puffer cylinder(they are called 'serial type', ' parallel/exchanged type ,' and ' parallel/separated type ' respectively in this work) were designed and manufactured and then the tests of operating characteristics and interrupting were performed using a simplified synthetic test facility. The interruption capability with the type and the opening speed and the pressure rise which is required to interrupt were examined. The change of pressure rise with the number of interruption was given quantitatively and therefore the pressure rise can be predicted. Finally, it was shown that the interruption capability tends to increase with the increasing of opening speed in the puffer type; however, the hybrid type interrupter has a different interruption characteristic.

Operating Characteristics of Hybrid Type Superconducting Fault Current Limiter (하이브리드형 초전도 한류기의 동작 특성)

  • Cho, Yong-Sun;Nam, Gueng-Hyun;Lim, Sung-Hun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.6
    • /
    • pp.255-258
    • /
    • 2006
  • We investigated the operating characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the inductance of secondary windings. The hybrid type SFCL consists of a transformer that has a primary winding and a secondary winding with serially connected $YBa_2Cu_3O_7$ (YBCO) films. The resistive-type SFCL has difficulty when it comes to raising the capacity of the SFCL due to slight differences of critical current densities between units and structure of the SFCL. The hybrid-type SFCL with closed-loop is able to achieve capacity increase through the electrical isolation and reduction of the inductance of the secondary winding with a superconducting element of the same critical current. On the other hand, the current limiting characteristics were nearly identical in the hybrid-type SFCL with open-loop compared to closed-loop, but quench time was longer than the hybrid-type SFCL with closed-loop. We confirmed that the capacity of the SFCL was increased effectively by the reduced inductance of the secondary winding. In addition, the power burden of the system also could be lowered by reducing the inductance of secondary winding.

Estimation of the exponential distribution based on multiply Type I hybrid censored sample

  • Lee, Kyeongjun;Sun, Hokeun;Cho, Youngseuk
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.3
    • /
    • pp.633-641
    • /
    • 2014
  • The exponential distibution is one of the most popular distributions in analyzing the lifetime data. In this paper, we propose multiply Type I hybrid censoring. And this paper presents the statistical inference on the scale parameter for the exponential distribution when samples are multiply Type I hybrid censoring. The scale parameter is estimated by approximate maximum likelihood estimation methods using two different Taylor series expansion types ($AMLE_I$, $AMLE_{II}$). We also obtain the maximum likelihood estimator (MLE) of the scale parameter ${\sigma}$ under the proposed multiply Type I hybrid censored samples. We compare the estimators in the sense of the root mean square error (RMSE). The simulation procedure is repeated 10,000 times for the sample size n=20 and 40 and various censored schemes. The $AMLE_{II}$ is better than $AMLE_I$ in the sense of the RMSE.

Estimation of Interruption Capability of a Serial-Hybrid Type Model Gas Circuit Breaker (직렬-복합소호형 모델 가스차단기의 차단성능평가)

  • 송기동;정진교;박경엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.538-544
    • /
    • 2004
  • This paper presents the interruption capability of serial-hybrid type GCB (gas circuit breaker) compared with that of puffer type. First a puffer type model interrupter which has the stroke length of 80 mm has been designed and manufactured. And also, a serial-hybrid type interrupter which has the same design parameters as the puffer type interrupter except the serially arranged thermal-expansion chamber and puffer cylinder has been fabricated. Using a simplified synthetic test facility, the critical interruption capabilities of the two GCBs have been estimated. The critical di/dt, the critical dV/dt of ITRV (initial transient recovery voltage) and the minimum arcing time of the puffer type model GCB were 10.7 A/${\mu}\textrm{s}$, 5.5 kV/${\mu}\textrm{s}$, and 15.0 ms respectively. In the case of serial-hybrid type model GCB, each of the values was 16.6A/${\mu}\textrm{s}$, 11.5 kV/${\mu}\textrm{s}$ and 13.0 ms. As a conclusion of this work, it has been quantitatively confirmed that the hybrid type interrupter can obtain the sufficient interruption capability at the operating force which is so low that puffer type interrupter has not the interruption capability.

Comparison of Thermal Recovery Characteristics of Hybrid Type Model Gas Interrupters According to the Arrangement of Thermal Expansion Chamber and Puffer Cylinder (팽창실과 파퍼 실린더의 배열형태에 따른 복합소호 모델 가스차단부의 열적회복특성 비교)

  • Song Ki-Dong;Chong Jin-Kyo;Park Kyong-Yop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.725-731
    • /
    • 2004
  • In this study, the three type hybrid interrupters according to the arrangement of the thermal expansion chamber and the puffer cylinder(they are called 'serial type', 'parallel/exchanged type', and 'parallel/separated type' respectively in this work) were designed and manufactured. This paper presents the tested results of the thermal recovery characteristics on the interrupters using a simplified synthetic test facility. The 'serial type' hybrid interrupter which is to obtain more easily the pressure rise for the thermal recovery compared with the others has the best capability in the thermal recovery characteristics. In order to investigate the stress on the operating mechanism, the distortion of the stroke wave in on-load test was examined to the stroke curve in no-load test. The biggest distortion was occurred in the 'parallel/exchanged type' hybrid interrupter. Finally, the small interruption capability on the three type interrupters was estimated by a theoretical form and the 'parallel/separated type' hybrid interrupter has the advantage of the others in the view of structure.