• 제목/요약/키워드: Hybrid substructure

검색결과 53건 처리시간 0.023초

Gas permeation property of organic-inorganic hybrid membrane made by ion-beam irradiation

  • Kawakami, Hiroyoshi
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.90-93
    • /
    • 2004
  • In this study, we have reported an organic-inorganic hybrid membrane, which exhibits an asymmetric structure consisted of a carbonized skin layer and a polyimide porous substructure, to synthesize a novel gas separation membrane combining high gas permeability and selectivity. Both the gas permeability and selectivity of the carbonized layer significantly enhanced when compared with those determined in the control polyimide.

  • PDF

부분 구조 모드 합성법 및 유전 전략 최적화 기법을 이용한 비부합 절점을 가진 구조물의 구조변경 (Structural Dynamics Modification of Structures Having Non-Conforming Nodes Using Component Mode Synthesis and Evolution Strategies Optimization Technique)

  • 이준호;정의일;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.651-659
    • /
    • 2002
  • Component Mode Synthesis (CMS) is a dynamic substructuring technique to get an approximate eigensolutions of large degree-of-freedom structures divisible into several components. But, In practice. most of large structures are modeled by different teams of engineers. and their respective finite element models often require different mesh resolutions. As a result, the finite element substructure models can be non-conforming and/or incompatible. In this work, A hybrid version of component mode synthesis using a localized lagrange multiplier to treat the non-conforming mesh problem was derived. Evolution Strategies (ESs) is a stochastic numerical optimization technique and has shown a robust performance for solving deterministic problems. An ESs conducts its search by processing a population of solutions for an optimization problem based on principles from natural evolution. An optimization example for raising the first natural frequency of a plate structure using beam stiffeners was presented using hybrid component mode synthesis and robust evolution strategies (RES) optimization technique. In the example. the design variables are the positions and lengths of beam stiffeners.

  • PDF

잔여 동연성 부가 모드를 고려한 혼합 부분 모드 합성법 (Hybrid Component Mode Synthesis Considering Residual Dynamic Flexibility Attachment Mode)

  • 차현주;김진호;이시복
    • 대한기계학회논문집A
    • /
    • 제29권5호
    • /
    • pp.716-725
    • /
    • 2005
  • The method of substructure synthesis o. component mode synthesis(CMS) provides an effective means of dynamic analysis of very large and/or complex structures. In this study, residual dynamic flexibility attachment modes in hybrid component mode synthesis are considered for the purpose of exactly compensating the effect of higher order truncated modes. Following this way, the analysis accuracy of the synthesized structure can be improved effectively with less computational effort. In order to show the accuracy and effectiveness of the proposed hybrid component mode synthesis(HCMS), numerical experiments were carried out for the models of a clamped-clamped beam. The results verified the effectiveness of the proposed method.

비부합 절점으로 이루어진 구조물의 합성과 재해석 (On a Substructure Synthesis Having Non-Matching Nodes)

  • 정의일;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.155-160
    • /
    • 2001
  • Actual engineering structure is frequently very complex, and parts of structure are designed independently by different engineers. Also each structure contains so many degree of freedom. For these reason, methods have been developed which permits the structure to be divided into components or substructures, with analysis being done on a small substructure in order to obtain a full structural system. In such case, because of different mesh size among finite element model (FEM) or different matching points among FEM models and experimentally obtained models, their interfacing points may be non-matching. Solving this non-matching problem is useful to other application such as structural dynamic modification or model updating. In this work, virtual node concept is introduced. Lagrange multipliers are used to enforce the interface compatibility constraint, and interface displacement is approximated by polynomial presentation. The governing equation of whole structure is derived using hybrid variational principle. The eigenvalue of whole structure are calculated using the determinant search method. The number of degree of freedom in the eigenvalue problem can be drastically reduced to just the number of interface degree of freedom. Some numerical simulation is performed to show usefulness of synthesis method.

  • PDF

강 뼈대 구조물의 다자유도 실시간 하이브리드 동적 실험 (Multi-DOF Real-time Hybrid Dynamic Test of a Steel Frame Structure)

  • 김세훈;나옥빈;김성일
    • 대한토목학회논문집
    • /
    • 제33권2호
    • /
    • pp.443-453
    • /
    • 2013
  • 하이브리드 실험은 수치해석 모형과 물리적 부분구조 모형사이의 상호작용을 통하여 구조물의 거동을 예측하는 실험법이다. 본 연구에서는 지진하중 재하 시 1경간 2층 강 뼈대 구조물에 대한 다자유도 하이브리드 실험을 수행하고 유효성을 확보하는데 그 목적이 있다. 이를 위해 전용 하이브리드 수치해석 프로그램인 FEAPH을 개발하였으며, 최적화된 시스템을 구축하였다. FEAPH은 고정 반복법(Fixed iteration)과 병렬화(Parallelization) 기법을 적용하여 순차적 해석에서 발생되는 비효율적 연산을 개선하였다. 또한, 종전에 데이터 통신과 부분구조물과 해석프로그램간의 인터페이스를 간략화하여 하이브리드 시스템 구성을 최적화 하였다. 그 결과, 입력 가진시간(30초) 대비 약 10%의 실험시간이 소요되었다. 시스템의 신뢰성을 검증하고 선형실험과 강 뼈대 구조물의 동적거동을 예측하기 위해 비선형 실험을 수행하였으며 수치해석과의 변위응답이력은 거의 일치 하였다. 그러나 최대변위에 대한 응답은 다소 차이를 보였으며, 이는 재료 비선형성에 대한 해석상의 오차와 영구변형에 의해 발생한 것으로 판단된다. 따라서 적절한 재료 비선형 모델과 알고리즘의 개선이 이루어지면, 실시간 하이브리드 시스템은 구조물의 동적거동을 예측하는데 유용하게 활용될 것이며, 추후 진동대 실험을 대체할 수 있는 효과적인 실험 방법이 될 것으로 판단된다.

Model updating with constrained unscented Kalman filter for hybrid testing

  • Wu, Bin;Wang, Tao
    • Smart Structures and Systems
    • /
    • 제14권6호
    • /
    • pp.1105-1129
    • /
    • 2014
  • The unscented Kalman filter (UKF) has been developed for nonlinear model parametric identification, and it assumes that the model parameters are symmetrically distributed about their mean values without any constrains. However, the parameters in many applications are confined within certain ranges to make sense physically. In this paper, a constrained unscented Kalman filter (CUKF) algorithm is proposed to improve accuracy of numerical substructure modeling in hybrid testing. During hybrid testing, the numerical models of numerical substructures which are assumed identical to the physical substructures are updated online with the CUKF approach based on the measurement data from physical substructures. The CUKF method adopts sigma points (i.e., sample points) projecting strategy, with which the positions and weights of sigma points violating constraints are modified. The effectiveness of the proposed hybrid testing method is verified by pure numerical simulation and real-time as well as slower hybrid tests with nonlinear specimens. The results show that the new method has better accuracy compared to conventional hybrid testing with fixed numerical model and hybrid testing based on model updating with UKF.

Real-time hybrid testing using model-based delay compensation

  • Carrion, Juan E.;Spencer, B.F. Jr.
    • Smart Structures and Systems
    • /
    • 제4권6호
    • /
    • pp.809-828
    • /
    • 2008
  • Real-time hybrid testing is an attractive method to evaluate the response of structures under earthquake loads. The method is a variation of the pseudodynamic testing technique in which the experiment is executed in real time, thus allowing investigation of structural systems with time-dependent components. Real-time hybrid testing is challenging because it requires performance of all calculations, application of displacements, and acquisition of measured forces, within a very small increment of time. Furthermore, unless appropriate compensation for time delays and actuator time lag is implemented, stability problems are likely to occur during the experiment. This paper presents an approach for real-time hybrid testing in which time delay/lag compensation is implemented using model-based response prediction. The efficacy of the proposed strategy is verified by conducting substructure real-time hybrid testing of a steel frame under earthquake loads. For the initial set of experiments, a specimen with linear-elastic behavior is used. Experimental results agree well with the analytical solution and show that the proposed approach and testing system are capable of achieving a time-scale expansion factor of one (i.e., real time). Additionally, the proposed method allows accurate testing of structures with larger frequencies than when using conventional time delay compensation methods, thus extending the capabilities of the real-time hybrid testing technique. The method is then used to test a structure with a rate-dependent energy dissipation device, a magnetorheological damper. Results show good agreement with the predicted responses, demonstrating the effectiveness of the method to test rate-dependent components.

Pseudo-dynamic and cyclic loading tests on a steel-concrete vertical hybrid structure

  • Wang, Bo;Wu, Tao;Dai, Huijuan;Bai, Guoliang;Wu, Jian
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.399-409
    • /
    • 2019
  • This paper presents the experimental investigations on the seismic performance of a peculiar steel-concrete vertical hybrid structural system referred to as steel truss-RC tubular column hybrid structure. It is typically applied as the supporting structural system to house air-cooled condensers in thermal power plants (TPPs). Firstly, pseudo-dynamic tests (PDTs) are performed on a scaled substructure to investigate the seismic performance of this hybrid structure under different hazard levels. The deformation performance, deterioration behavior and energy dissipation characteristics are analyzed. Then, a cyclic loading test is conducted after the final loading case of PDTs to verify the ultimate seismic resistant capacity of this hybrid structure. Finally, the failure mechanism is discussed through mechanical analysis based on the test results. The research results indicate that the steel truss-RC tubular column hybrid structure is an anti-seismic structural system with single-fortification line. RC tubular columns are the main energy dissipated components. The truss-to-column connections are the structural weak parts. In general, it has good ductile performance to satisfy the seismic design requirements in high-intensity earthquake regions.

Real-time hybrid substructuring of a base isolated building considering robust stability and performance analysis

  • Avci, Muammer;Botelho, Rui M.;Christenson, Richard
    • Smart Structures and Systems
    • /
    • 제25권2호
    • /
    • pp.155-167
    • /
    • 2020
  • This paper demonstrates a real-time hybrid substructuring (RTHS) shake table test to evaluate the seismic performance of a base isolated building. Since RTHS involves a feedback loop in the test implementation, the frequency dependent magnitude and inherent time delay of the actuator dynamics can introduce inaccuracy and instability. The paper presents a robust stability and performance analysis method for the RTHS test. The robust stability method involves casting the actuator dynamics as a multiplicative uncertainty and applying the small gain theorem to derive the sufficient conditions for robust stability and performance. The attractive feature of this robust stability and performance analysis method is that it accommodates linearized modeled or measured frequency response functions for both the physical substructure and actuator dynamics. Significant experimental research has been conducted on base isolators and dampers toward developing high fidelity numerical models. Shake table testing, where the building superstructure is tested while the isolation layer is numerically modeled, can allow for a range of isolation strategies to be examined for a single shake table experiment. Further, recent concerns in base isolation for long period, long duration earthquakes necessitate adding damping at the isolation layer, which can allow higher frequency energy to be transmitted into the superstructure and can result in damage to structural and nonstructural components that can be difficult to numerically model and accurately predict. As such, physical testing of the superstructure while numerically modeling the isolation layer may be desired. The RTHS approach has been previously proposed for base isolated buildings, however, to date it has not been conducted on a base isolated structure isolated at the ground level and where the isolation layer itself is numerically simulated. This configuration provides multiple challenges in the RTHS stability associated with higher physical substructure frequencies and a low numerical to physical mass ratio. This paper demonstrates a base isolated RTHS test and the robust stability and performance analysis necessary to ensure the stability and accuracy. The tests consist of a scaled idealized 4-story superstructure building model placed directly onto a shake table and the isolation layer simulated in MATLAB/Simulink using a dSpace real-time controller.