Hybrid Procedure for Aortic Arch Aneurysm: Arch Vessels Debranching andThoracic Endovascular Aortic Repair? -2 case Reports- (대동맥궁 대동맥류에서 Hybrid 술식의 적용 - 2예 보고 -)

  • Kim, Seok;Kwon, Oh-Choon;Lee, Sub;Cho, Jun-Woo;Bae, Chi-Hoon;Park, Ki-Sung
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.529-533
    • /
    • 2010
  • Conventional surgery for aortic arch aneurysms have many postoperative complications and a high mortality rate due to prolonged cardiopulmonary bypass time, especially in high risk patients. In this report, we present two cases of a hybrid procedure that involves open brachiocephalic bypass with concomitant endovascular arch stent grafting in high risk patients with distal aortic arch aneurysm.

Performance Evaluation of Lower Complexity Hybrid-Fix-and-Round-LLL Algorithm for MIMO System

  • Lv, Huazhang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.6
    • /
    • pp.2554-2580
    • /
    • 2018
  • Lenstra-Lenstra-$Lov{\acute{a}}sz$ (LLL) is an effective receiving algorithm for Multiple-Input-Multiple-Output (MIMO) systems, which is believed can achieve full diversity in MIMO detection of fading channels. However, the LLL algorithm features polynomial complexity and shows poor performance in terms of convergence. The reduction of algorithmic complexity and the acceleration of convergence are key problems in optimizing the LLL algorithm. In this paper, a variant of the LLL algorithm, the Hybrid-Fix-and-Round LLL algorithm, which combines both fix and round measurements in the size reduction procedure, is proposed. By utilizing fix operation, the algorithmic procedure is altered and the size reduction procedure is skipped by the hybrid algorithm with significantly higher probability. As a consequence, the simulation results reveal that the Hybrid-Fix-and-Round-LLL algorithm carries a faster rate of convergence compared to the original LLL algorithm, and its algorithmic complexity is at most one order lower than original LLL algorithm in real field. Comparing to other families of LLL algorithm, Hybrid-Fix-and-Round-LLL algorithm can make a better compromise in performance and algorithmic complexity.

Robust optimization of a hybrid control system for wind-exposed tall buildings with uncertain mass distribution

  • Venanzi, Ilaria;Materazzi, Annibale Luigi
    • Smart Structures and Systems
    • /
    • v.12 no.6
    • /
    • pp.641-659
    • /
    • 2013
  • In this paper is studied the influence of the uncertain mass distribution over the floors on the choice of the optimal parameters of a hybrid control system for tall buildings subjected to wind load. In particular, an optimization procedure is developed for the robust design of a hybrid control system that is based on an enhanced Monte Carlo simulation technique and the genetic algorithm. The large computational effort inherent in the use of a MC-based procedure is reduced by the employment of the Latin Hypercube Sampling. With reference to a tall building modeled as a multi degrees of freedom system, several numerical analyses are carried out varying the parameters influencing the floors' masses, like the coefficient of variation of the distribution and the correlation between the floors' masses. The procedure allows to obtain optimal designs of the control system that are robust with respect to the uncertainties on the distribution of the dead and live loads.

Design Optimization of Large Scale Structural Systems based on Multilevel Hybrid Approximation (다단계 혼성근사화에 기초한 대형구조계의 설계최적화)

  • 김경일;박종회;황진하
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.249-256
    • /
    • 2002
  • A new optimization procedure with approximate reanalysis module, using the staged hybrid methods with substructuring, is proposed in is study. In this procedure, displacements are calculated with two step mixed procedures. First step is to introduce the conservative approximation, which is a hybrid form of the linear and reciprocal approximation, as local approximation. In the next step, it is combined with the global approximation by reduced basis approach. The quality of reanalyzed quantities can be greatly improved through these staged hybrid approximations, specially for large changes in the design. Overall procedures are based on substructuring scheme. Several numerical examples illustrate the validity and effectiveness of the proposed methods.

  • PDF

A Study on a VOF Method for the Improvement of Free Surface Capturing (VOF 법의 자유수면 포착정도 향상을 위한 연구)

  • Park, Il-Ryong;Kim, Wu-Joan;Kim, Jin;Van, Suak-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.2 s.140
    • /
    • pp.88-97
    • /
    • 2005
  • A new numerical scheme solving two-phase flow, the Hybrid VOF method for improved free surface capturing has been developed by combining a volume capturing VOF method with the Level-Set reinitialization procedure. For validation, the proposed method is applied to 3-D bubble rising problem, dam breaking and the free surface flow around a commercial container ship. The calculated results by using the Hybrid VOF method with the two previously applied VOF formulations are compared with available numerical and experimental data. It is found that the new method provides more reasonable results than the two previous ones.

A study on the designing of a hybrid step motor and its prototype (Hybrid step motor의 설계 및 시작품 제작에 관한 연구)

  • 김광배;백문홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.377-382
    • /
    • 1986
  • This paper describes the modelling method of hybrid step motors including magnetic saturation effects of iron parts and the simulation for design of a prototype. Based on the above procedure, the prototype of a step motor is produced and its characteristics are discussed.

  • PDF

Hybrid-QUICK Scheme Using Finite-Volume Method

  • Choi, Jung-Eun
    • Journal of Hydrospace Technology
    • /
    • v.2 no.2
    • /
    • pp.57-67
    • /
    • 1996
  • The formulation for hybrid-QUICK scheme of convective transport terms in finite-volume calculation procedure is presented. Source terms are modified to apply the hybrid-QUICK scheme. Test calculations are performed for wall-driven cavity flow at Re=$10_2$, $10_3$, and $10_4$. These include the evaluation of boundary conditions approximated by third-order finite difference scheme. The stable and converged solutions are obtained without unsteady terms in the momentum equations. The results using hybrid-QUICK scheme show no difference with those using hybrid scheme at low Re ($=10_2$) and are better at higher Re ($10_3$, and $10_4$).

  • PDF

Muscle Fiber Typing in Bovine and Porcine Skeletal Muscles Using Immunofluorescence with Monoclonal Antibodies Specific to Myosin Heavy Chain Isoforms

  • Song, Sumin;Ahn, Chi-Hoon;Kim, Gap-Don
    • Food Science of Animal Resources
    • /
    • v.40 no.1
    • /
    • pp.132-144
    • /
    • 2020
  • The aim of this study was to optimize staining procedures for muscle fiber typing efficiently and rapidly in bovine and porcine skeletal muscles, such as longissimus thoracis, psoas major, semimembranosus, and semitendinosus muscles. The commercially available monoclonal anti-myosin heavy chain (MHC) antibodies and fluorescent dye-conjugated secondary antibodies were applied to immunofluorescence histology. Two different procedures, such as cocktail and serial staining, were adopted to immunofluorescence analysis. In bovine muscles, three pure types (I, IIA, and IIX) and one hybrid type, IIA+IIX, were identified by the cocktail procedure with a combination of BA-F8, SC-71, BF-35, and 6H1 anti-MHC antibodies. Porcine muscle fibers were typed into four pure types (I, IIA, IIX, and IIB) and two hybrid types (IIA+IIX and IIX+IIB) by a serial procedure with a combination of BA-F8, SC-71, BF-35, and BF-F3. Unlike for bovine muscle, the cocktail procedure was not recommended in porcine muscle fiber typing because of the abnormal reactivity of SC-71 antibody under cocktail procedure. Within the four antibodies, combinations of two or more anti-MHC antibodies allowed us to distinguish pure fiber types or all fiber types including hybrid types. Application of other secondary antibodies conjugated with different fluorescent dyes allowed us to get improved image resolution that clearly distinguished hybrid fibers. Muscle fiber characteristics differed depending on species and muscle types.

The hybrid perventricular closure of apical muscular ventricular septal defect with Amplatzer duct occluder

  • Kim, Soo Jin;Huh, June;Song, Jin Young;Yang, Ji-Hyuk;Jun, Tae-Gook;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.4
    • /
    • pp.176-181
    • /
    • 2013
  • Purpose: Apical muscular ventricular septal defects (MVSDs), especially in small infants, can be difficult to manage using surgical and percutaneous closure. An intraoperative perventricular procedure is a good option for closing apical MVSDs in small children with or without associated cardiac anomalies. We evaluated the results of hybrid perventricular closure of apical MVSDs performed using an Amplatzer duct occluder (ADO). Methods: We retrospectively reviewed the medical records of 5 patients who underwent hybrid perventricular closure of MVSDs with ADOs, from March 2006 to May 2011. The median patient age at the time of the procedure was 12 months (range, 25 days to 25 months), and the median body weight was 9.1 kg (range, 4.3 to 15 kg). Two patients had multiple ventricular septal defects (VSDs; additional perimembranous VSD in 1 patient and multiple MVSDs in the other) and 3 patients had associated cardiac anomalies; complete transposition of the great arteries in 1 patient and an atrial septal defect in 2 patients. All the procedures were performed on beating hearts, exception in 1 case. The ADO selected for the aortic side was at least 1 to 2 mm larger than the largest VSD in the left ventricle side. Results: The procedure was successful in all patients and each device was well positioned. During the median follow-up of 2.4 years, a small residual VSD was noted in 2 patients who had multiple VSDs and no leakage was seen in the other 3 patients. Conclusion: Perventricular closure of MVSD with an ADO is a good option for patients with apical MVSD. However, careful manipulation is important, especially in the case of small infants.

Endoscopic submucosal dissection in colorectal neoplasia performed with a waterjet system-assisted knife: higher en-bloc resection rate than conventional technique

  • Paolo Cecinato;Matteo Lucarini;Francesco Azzolini;Mariachiara Campanale;Fabio Bassi;Annalisa Cippitelli;Romano Sassatelli
    • Clinical Endoscopy
    • /
    • v.55 no.6
    • /
    • pp.775-783
    • /
    • 2022
  • Background/Aims: Colorectal endoscopic submucosal dissection (ESD) is burdened by its associated high risk of adverse events and long procedure time. Recently, a waterjet-assisted knife was introduced to simplify and speed up the procedure. The aim of this study was to evaluate the efficacy and safety of waterjet-assisted ESD (WESD) compared to that of the conventional ESD (CESD) technique. Methods: The charts of 254 consecutive patients who underwent colorectal ESD between January 2014 and February 2021 for colorectal neoplasms were analyzed. The primary outcome was the en-bloc resection rate. Secondary outcomes were complete and curative resection rates, the need to switch to a hybrid ESD, procedure speed, the adverse event rates, and the recurrence rates. Results: Approximately 174 neoplasias were considered, of which, 123 were removed by WESD and 51 by CESD. The en-bloc resection rate was higher in the WESD group (94.3% vs. 84.3%). Complete resection rates and curative resection rates were similar. The need to switch to a hybrid ESD was greater during CESD (39.2% vs. 13.8%). Procedure speed and adverse event rates were similar. During follow-up, one recurrence occurred after a WESD. Conclusions: WESD allows a high rate of en-bloc resections and less frequently requires a rescue switch to the hybrid ESD compared to CESD.