• Title/Summary/Keyword: Hybrid imaging

Search Result 123, Processing Time 0.035 seconds

KVN single-dish survey of the MALATANG galaxies

  • Poojon, Panomporn;Chung, Aeree;Lee, Bumhyun;Baek, Junhyun;Jung, Taehyun;Sohn, Bong Won;Oh, Se-Heon;Sengupta, Chandreyee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.57.2-57.2
    • /
    • 2018
  • We present the preliminary result from our KVN single-dish observations of the MALATANG sample. The MALATANG (Mapping the dense molecular gas in the strongest star-forming Galaxies) is one of the JCMT legacy surveys on the nearest 23 IR-brightest galaxies beyond the Local Group. The goal of the MALATANG survey is to map the sample in the dense gas tracers (HCN and HCO+J=4-3), and probe the relationships between the dense molecular gas and star formation activities. As a complementary study, we recently launched a KVN/KaVA program on the same sample, in order to measure their flux densities and parsec-scale jet/outflows in the millimeter regime, which will be greatly useful in understanding the initial conditions of the feedback process. In this work, we present the preliminary result from our pilot KVN single-dish program on a sub-sample, which will be used to select the future VLBI imaging study under plan. We investigate the KVN spectral energy distributions (SED) of the sample as a function of the power source of the luminous IR brightness of each target (starburst? AGN? or hybrid?). We also discuss the technical challenges that we experienced during our KVN observations due to the large size of the sample in the sky.

  • PDF

A CONFOCAL LASER SCANNING MICROSCOPIC STUDY ON THE INTERFACE BETWEEN TOOTH COLORED RESTORATIVE MATERIALS AND DENTIN (공초점레이저주사현미경을 이용한 심미수복재와 상아질의 접착계면에 관한 연구)

  • Park, Byung-Chul;Cho, Young-Gon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.313-320
    • /
    • 2000
  • The purpose of this study was to evaluate on the interfacial morphology between dentin and restorative materials. In this in vitro study, the cavity wall restorated with 3 different kinds of tooth colored restorative materials [resin-modified Glass Ionomer cement (Fuji II LC), composite resin (Z-100), compomer (Dyract)]. The thirty extracted human molar teeth without caries and/or restorations are used. The experimental teeth were randomly divided into three groups of ten teeth each. In each group, Wedge shaped cavities (width: 3mm, length: 2mm, depth: 1.5mm) were prepared at the cementoenamel junction on buccal and lingual surfaces. The adhesive of composite resin were mixed with rhodamine B. Primer of composite resin, Prime & Bond 2.1 of Dyract and liquid of Fuji II LC were mixed with fluorescein. In group 1, the cavity wall was treatment with dentin conditioner, and then restorated with Fuji II LC. In group 2, the cavity wall was treatment with Prime & Bond 2.1 and then restorated with Dyract. In group 3, the cavity wall was etching with 10% maleic acid, applied with primer and bonding agent and then restorated with Z-100. The interface between dentin and restorative materials was observed by fluoresence imaging with a confocal laser scanning microscope. The results were as follows : 1. In Glass ionomer group, adaptation of resin modified Glass-ionomer restoration against cavity wall is tight, but the crack formed inside of restoration were observed. 2. In Dyract group, the penetration of resin tag is shorter and the width of hybrid layer is narrower than composite resin group. 3. In Z-100 group, primer penetrated deeply through dentinal tubule. Also bonding agent was penetrated along the primer, but the penetration length is shorter than primer part, and in 3-D image, the resin tag is conical shape and lateral branch is observed.

  • PDF

Energy Band Structure and Photocatalytic Property of Fe-doped Zn2TiO4 Material

  • Jang, Jum-Suk;Borse, Pramod H.;Lee, Jae-Sung;Lim, Kwon-Taek;Jung, Ok-Sang;Jeong, Euh-Duck;Bae, Jong-Seong;Won, Mi-Sook;Kim, Hyun-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.3021-3024
    • /
    • 2009
  • $Zn_2Ti_{1-x}Fe_xO_4\;(0\;{\leq}\;x\;{\leq}\;0.7)$ photocatalysts were synthesized by polymerized complex (PC) method and investigated for its physico-chemical as well as optical properties. $Zn_2Ti_{1-x}Fe_xO_4$ can absorb not only UV light but also visible light region due to doping of Fe in the Ti site of $Zn_2TiO_4$ lattice because of the band transition from Fe 3d to the Fe 3d + Ti3d hybrid orbital. The photocatalytic activity of Fe doped $Zn_2TiO_4$ samples for hydrogen production under UV light irradiation decreased with an increase in Fe concentration in $Zn_2TiO_4$. Consequently, there exists an optimized concentration of iron for improved photocatalytic activity under visible light (${\lambda}{\leq}$420 nm)

Blending of Silica Nanoparticles with PBA/PS Core-Shell Baroplastic Polymers (PBA/PS 코어-셀 압력가소성 고분자와 실리카 나노입자의 블렌딩)

  • Kim, Min-Jeong;Choi, Yong-Doo;Ryu, Sang-Woog
    • Polymer(Korea)
    • /
    • v.32 no.6
    • /
    • pp.573-579
    • /
    • 2008
  • PBA/PS core-shell polymer nanoparticles were synthesized by two stage emulsion polymerization and hybridized with silica nanoparticle by simple mixing in emulsion state and following precipitation into water/methanol mixture dissolving $Na_2CO_3$. The stress-strain curve revealed that the elastic modulus was increased with increasing molecular weight of polymer and silica weight fraction but decreased with increasing size of core-shell nanoparticle. Especially, there was a rapid increase of elastic modulus with silica blending. As a result, 6 times higher elastic modulus was observed in PBA/PS core-shell baroplastic sample processed at 25$^\circ$C under 13.8 MPa for 5 min by blending with 13.0 wt% of silica nanoparticle.

Evaluation of Usefulness for Diagnosis of Lung Cancer on Integrated PET-MRI Using Decision Matrix (판정행렬을 기반한 일체형 PET-MRI의 폐암 진단 유용성 평가)

  • Kim, Jung-Soo;Yang, Hyun-Jin;Kim, Yoo-Mi;Kwon, Hyeong-Jin;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.635-643
    • /
    • 2021
  • The results of empirical researches on the diagnosis of lung cancer are insufficient, so it is limited to objectively judge the clinical possibility and utilization according to the accuracy of diagnosis. Thus, this study retrospectively analyzed the lung cancer diagnostic performance of PET-MRI (Positron Emission Tomography-Magnetic Resonance Imaging) by using the decision matrix. This study selected and experimented total 165 patients who received both hematological CEA (Carcinoembryonic Antigen) test and hybrid PET-MRI (18F-FDG, 5.18 MBq/kg / Body TIM coil. VIVE-Dixon). After setting up the result of CEA (positive:>4 ㎍/ℓ. negative:<2.5㎍/ℓ) as golden data, the lung cancer was found in the image of PET-MRI, and then the SUVmax (positive:>4, negative:<1.5) was measured, and then evaluated the correlation and significance of results of relative diagnostic performance of PET-MRI compared to CEA through the statistical verification (t-test, P>0.05). Through this, the PET-MRI was analyzed as 96.29% of sensitivity, 95.23% of specificity, 3.70% of false negative rate, 4.76% of false positive rate, and 95.75% of accuracy. The false negative rate was 1.06% lower than the false positive rate. The PET-MRI that significant accuracy of diagnosis through high sensitivity and specificity, and low false negative rate and false positive rate of lung cancer, could acquire the fusion image of specialized soft tissue by combining the radio-pharmaceuticals with various sequences, so its clinical value and usefulness are regarded as latently sufficient.

Comparison of Multi-Label U-Net and Mask R-CNN for panoramic radiograph segmentation to detect periodontitis

  • Rini, Widyaningrum;Ika, Candradewi;Nur Rahman Ahmad Seno, Aji;Rona, Aulianisa
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.383-391
    • /
    • 2022
  • Purpose: Periodontitis, the most prevalent chronic inflammatory condition affecting teeth-supporting tissues, is diagnosed and classified through clinical and radiographic examinations. The staging of periodontitis using panoramic radiographs provides information for designing computer-assisted diagnostic systems. Performing image segmentation in periodontitis is required for image processing in diagnostic applications. This study evaluated image segmentation for periodontitis staging based on deep learning approaches. Materials and Methods: Multi-Label U-Net and Mask R-CNN models were compared for image segmentation to detect periodontitis using 100 digital panoramic radiographs. Normal conditions and 4 stages of periodontitis were annotated on these panoramic radiographs. A total of 1100 original and augmented images were then randomly divided into a training (75%) dataset to produce segmentation models and a testing (25%) dataset to determine the evaluation metrics of the segmentation models. Results: The performance of the segmentation models against the radiographic diagnosis of periodontitis conducted by a dentist was described by evaluation metrics(i.e., dice coefficient and intersection-over-union [IoU] score). MultiLabel U-Net achieved a dice coefficient of 0.96 and an IoU score of 0.97. Meanwhile, Mask R-CNN attained a dice coefficient of 0.87 and an IoU score of 0.74. U-Net showed the characteristic of semantic segmentation, and Mask R-CNN performed instance segmentation with accuracy, precision, recall, and F1-score values of 95%, 85.6%, 88.2%, and 86.6%, respectively. Conclusion: Multi-Label U-Net produced superior image segmentation to that of Mask R-CNN. The authors recommend integrating it with other techniques to develop hybrid models for automatic periodontitis detection.

Evolution strategies of Digital Camera to cope with the progress of the Imaging Device and Web (이미징 디바이스 및 웹의 발전에 대응한 디지털 카메라의 진화전략에 관한 연구)

  • An, Ho-Seong;Byeon, Sang-Yeong;Kim, Jae-Beom
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.79-82
    • /
    • 2009
  • 본 연구는 인터넷의 진화 및 이미징 디바이스 전반의 발달에 따른 디지털 카메라의 진화 전략을 다룬 논문이다. 오늘날의 카메라 기술은 하루가 다르게 발전해 나가고 있다. 수동 필름 카메라에서부터 최첨단 하이브리드(hybrid) 카메라에 이르기 까지 카메라는 끊임없이 진화해 왔으며 사용자 계층 역시 다양해지고 있다. 디지털이 적용된 디지털 카메라의 경우, 웹의 발전과 더불어 활용도가 다양해 짐에 따라서 기존에는 전문가와 비전문가 계층으로 명확하게 나뉘던 사용자 계층도 그 경계가 모호해졌으며 사용자의 수 역시 비약적으로 증가하였다. 수많은 사업자들이 디지털 카메라 시장에 진출함에 따라, 높은 성장세가 지속되던 컴팩트 카메라 (compact camera)시장은 과포화기에 접어들어 성장성이 점차 감소하는 추세에 있으며, 전문가의 영역으로 여겨졌던 DSLR 시장 역시 선발업체의 높은 진입장벽과 이를 극복하기 위한 후발업체의 지속적인 도전으로 인해 경쟁은 치열하고 이익은 내기 어려운 레드 오션(red ocean)이 되었다. 이러한 상황 속에서 디지털 카메라가 활용될 수 있는 대표적 매체인 웹 역시 '웹 2.0' 이라는 용어가 생길 정도로 발전했다. 웹2.0시대가 본격화되어 서로 다른 사용자들이 자유롭게 컨텐츠를 공유하고 누구든지 쉽게 정보의 생산에 동참할 수 있게 됨으로써 기존의 웹에서 일어나지 않았던 다양한 변화들이 생겨나게 되었다. 본 연구에서는 변화의 특징들을 살펴보기 위해 웹 2.0 시대의 대표적인 컨텐츠 공유 커뮤니티로 자리매김한 야후(Yahoo)사(社) 플리커(Flickr)의 사례를 통해 디지털 카메라 사용자들의 디지털 카메라 사용패턴을 살펴보고 이를 통해 디지털 카메라의 진화를 설명하고자 한다. 인터넷이 발전하며 디지털 카메라와 관련 되어 나타난 대표적인 변화는 일반 소비자가 진화하는 점 이라고 볼 수 있다. 컨텐츠의 공유가 자유로운 웹 플랫폼의 등장, 카메라 기술이 결합된 소형 디지털 단말기의 발전 등으로 인해 비전문가 영역에 속해있던 일반 소비자 계층에 Flickr와 같은 웹 커뮤니티에서의 활동을 통해 준전문가 계층으로 진입하려는 욕구가 생기게 되었는데, 이렇게 형성된 욕구에 따라 디지털 카메라 시장 역시 새로운 수요를 만나게 되었다. 본 연구에서는 경쟁이 치열한 시장 상황 속에서 디지털 카메라의 향후 발전 방향을 알아보기 위해 우선 디지털 카메라 기능을 나누어 본 후, 이미징 디바이스 시장과 웹의 발전 형태에 대해 분석해보았다. 이어 본 연구에서는 분류된 디지털 카메라의 기능을 바탕으로 웹 2.0 시대에 시장을 주도할 수 있는 디지털 카메라의 변화방향에 대해서 알아보았다. 본 연구는 감성적 및 이성적 측면에서 디지털 카메라의 향후 전개방향을 살펴보았다는 점에서 이론적 실무적 함의를 가지는 논문이라고 사료된다.

  • PDF

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

A Study about Amendment of Safety Control of Computed Tomography (전산화단층촬영용장치의 안전관리 개정에 관한 연구)

  • Kim, Kyotae;Heo, Yeji;Oh, Kyungmin;Noh, Sicheul;Kang, Sangsik;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.383-387
    • /
    • 2013
  • Diagnostic imaging systems play a critical role in obtaining anatomical images, which increases the frequency of inspection all over the world. However the likelihood that patients are exposed to relatively high radiation dose increases, which may lead to an increase of patient dose due to unnecessary radiation exposure unless appropriate management is accompanied. Thus the revised edition of IEC 60601-2-44 which is constancy tests for CT equipment which is designated as special medical equipment and is subject to safety management was studied. The results suggested the 3rd has been revised rationally in order to overcome the limitations in the 2nd by adopting clear and enhanced references, which implies the replacement of IEC 60601-2-44 2nd edition with IEC 60601-2-44 3rd will prevent the patients from the harm from improper medical equipment.

Cervical Cancer Prevention for the Future: the Complimentary Roles of Cytology Screening and HPV Vaccination (자궁경부암 예방의 미래 : 세포선별검사와 HPV 예방접종의 역할)

  • McGoogan, Euphemia
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.1
    • /
    • pp.1-12
    • /
    • 2007
  • Approximately 70% of cervical cancers are caused by HPV types 16/18 and thus the implementation of vaccination programmes with vaccines against HPV types 16/18 will have a major impact on the incidence of cervical cancer worldwide. However, this reduction will not be seen until several decades after full implementation of such vaccination programmes since the vaccines must be given to young adolescents before exposure to the virus and women who are already sexually active are not likely to be protected. Both GSK and Merck insist that even vaccinated women must continue to participate in regular cervical screening by the most sensitive method available since the vaccine can only give protection against up to 70% of cervical cancers. It is unlikely that the current vaccines will be modified to include additional high risk HPV types in the foreseeable future. While HPV testing is highly sensitive, it is not recommended for women under 30 years of age nor for vaccinated women. Additionally, HPV testing has poor specificity. The Digene Hybrid Capture 2 test is licensed for use only in conjunction with a cytology test, not as a stand-alone test, and the high risk panel has recognised cross reactivity with low risk HPV types. None of the other HPV test methods currently commercially available are FDA approved and all must be internally validated before use. This makes comparison of test results between laboratories difficult. The most sensitive and specific screening test currently available for women of all ages is the Cytyc ThinPrep System consisting of the ThinPrep Pap Test (TPPT) and the ThinPrep Imaging System (Imager). The TPPT was the first LBC system approved by the US FDA in 1996 and there are about 4,000 processors in use worldwide. The Imager was FDA approved in 2003 and over 350 systems are in routine use, mainly in the US. 40% of TPPT in the US are processed on Imager. There is clear evidence in peer reviewed literature that the Imager increases laboratory productivity by 100% and growing evidence that Imager detects more high grade SIL than the conventional smear or manual evaluation of TPPT. This aspect is particularly important since the number of cytological abnormalities will decrease as vaccination programmes are implemented. Cytotechnologists will see fewer and fewer abnormal smears and their skills will be put at risk. By doubling throughput, Imager will allow cytotechnologists to maintain their skills.