• 제목/요약/키워드: Hybrid composite plate

검색결과 98건 처리시간 0.023초

강판 보강 집성재 보의 휨성능 평가 연구 (Evaluation on Flexural Performance of Steel Plate Reinforced GLT Beams)

  • 박금성;이상섭;곽명근
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.39-49
    • /
    • 2020
  • In this study, we will develop a hybrid cross-sectional shape of steel inserted type glued-laminated timber that can improve the strength of structural glued-laminated timber and maximize the ductility by using steel plate with excellent tensile and deformation ability. A total of three specimens were fabricated and the flexural performance test was carried out to evaluate the structural performance of the steel inserted type glued-laminated timber. In order to compare the effect of steel inserted glued-laminated timber, one structural glued-laminated timber test specimen composed of pure wood was manufactured. In addition, in order to evaluate the adhesion performance of the steel inserted, one each of a screw joint test specimen and a polyurethane joint test specimen was prepared. As a result, all the specimens showed the initial crack in the finger joint near the force point. This has been shown to be a cause of crack diffusion and strength degradation. The use of finger joints in the maximum moment section is considered to affect the strength and ductility of the glued-laminated timber beam. Polyurethane-adhesive steel inserted glued-laminated timber showed fully-composite behavior with little horizontal separation between the steel plate and glued-laminated timber until the maximum load was reached. This method has been shown to exhibit sufficient retention bending performance.

프리스트레스트 콘크리트-강 혼합거더의 휨 실험 및 경계면 수평계수 분석 (Flexural Experiment of PSC-Steel Mixed Girders and Evaluation for Analyses on Tangentional Stiffness of Connection)

  • 김광수;정광회;심정욱;유성원
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.231-237
    • /
    • 2008
  • 복합 구조 형식인 PSC-강 혼합 거더는 신형식 구조로서 비대칭 경간 구조물이나 장대교량에 적용될 수 있다. 본 연구에서는 매입길이, 보강철근, 스터드, 프리스트레스 힘 등을 변수로 총 14개의 실험체를 제작하여 혼합 거더의 접합부 거동을 분석하고자 하였다. 모든 실험체는 보강철근, 스터드, 강판 등의 순서로 기능을 손실하면서 파괴되었다. 실험 결과에 의하면 접합부의 성능에는 스터드 배치와 보강철근에 비해 프리스트레싱 힘이 상대적으로 큰 영향을 미치는 것으로 분석되었다. 이와 함께 매입길이에 비하여 스터드의 배치가 접합부 성능에 보다 중요한 역할을 하는 것으로 평가되었다. 실험적 연구와 함께 슬립을 고려한 3차원 비선형해석을 수행하였다. 경계면의 거동은 인터페이스 요소와 슬립 물성을 통하여 완전 합성, 부분합성, 비합성으로 분석할 수 있는데 혼합 거더의 접합부 설계에 따른 경계면 거동을 해석과 실험 결과를 통하여 분석하였다. 특히, 스터드 전단연결재가 적용된 혼합 거더는 극한하중 단계에서 부분합성 거동을 나타내며 보강 철근 또한 혼합 거더의 극한강도 증진에 기여하는 것으로 분석되었다.

단부 철근콘크리트-중앙부 철골로 구성된 복합(複合)보의 거동(擧動)에 관한 실험적 연구 (An Experimental Study on the Behavior of Hybrid Beam Composed of End Reinforced Concrete-Center Steel)

  • 강병수;김성은;최현식
    • 한국강구조학회 논문집
    • /
    • 제14권3호
    • /
    • pp.413-421
    • /
    • 2002
  • 본 연구에서는 반복 재하실험에 의해서 단부 철근콘크리트 중앙부 철골로 이루어진 복합보의 접합부 형상에 따른 역학적 거동을 파악하고자 한다. 실험결과와 종국내력식을 비교 검증하고 합성효과, 내진성능 및 응력전달의 유효성을 검토한다. 각 실험체의 유형은 주근용접형, 정착판 보강형, 시어코넥터 보강형, 시어코넥터형으로 한다. 그 결과 정착판 보강형과 시어코넥터 보강형은 내력 및 내진성능이 우수한 것으로 평가되었으며, 철근콘크리트와 철골 접합부분이 일체성을 확보하여 응력전달에 유리한 것으로 나타났다. 그러나 기존의 종국내력식은 실험결과와 다소 차이가 있는 것으로 나타나 보다 명확한 종국내력식이 요구되고 있다.

복합재료적층판의 진동해석을 위한 유한요소모델 II. 유한요소모델의 유도 및 해석 (Finite Element Analysis for Vibration of Laminated Plate Using a Consistent Discrete Theory Part II : Finite Element Formulation and Implementations)

  • 홍순조
    • 전산구조공학
    • /
    • 제7권4호
    • /
    • pp.103-111
    • /
    • 1994
  • 앞의 논문 Part 1 에서 유도한 변분원리를 이용하여 복합재료적층판의 진동해석을 할 수 있는 유한요소해석 모델을 개발하였다. 이 모델에서는 어느 한 층의 면내 변위와 나머지층 단면의 회전각, 그리고 판 전체의 연직방향처짐을 절점변수로 취하게 되어 n개층으로된 적층판의 경우 2(n+1)+1의 절점 자유도를 갖는다. 따라서, 판의 주변에서는 한층의 면내변위와 각층단면의 회전각을, 판의 면내에서는 연직방향 처짐을 경계조건값으로 정의할 수 있다. 이 모델에 의해 개발한 프로그램을 이용하여 각층의 재료특성이 크게 다른 혼종형 복합재료적층판(hybrid laminate)의 고유진동문제를 해석하였다. 탄성이론해 및 다른 유한요소해석결과와 본 해석결과와의 비교를 통해 제시모델이 기존의 다른 유한요소모델보다 정확함을 예시하였다.

  • PDF

프리스트레스트 강합성거더의 분절 접합부 구조거동에 관한 실험적 연구 (An Experimental Study on Structural Behavior of Segmental Joint in Prestressed Composite Girder)

  • Lee, Juwon;Ha, Taeyul;Yang, Inwook;Han, Jongwook
    • 한국재난정보학회 논문집
    • /
    • 제12권4호
    • /
    • pp.422-431
    • /
    • 2016
  • 본 연구에서는 프리스트레스트 강합성 거더의 콘크리트 케이싱 분절부 상세에 따른 연결부 성능 평가를 위해 각각 다른 분절부를 가진 실험체를 제작하여 실험하였다. 분절부가 없는 일반 강합성 거더와 분절부에 이음철근 보강 유무 및 이음철근 상세를 변수로 하는 총 4본의 비교 실험체를 제작하여 구조적 거동 평가하였다. 또한, 분절형 강합성 거더의 비균열등급 설계 가능 여부 및 균열발생 후 루프철근 상세에 따른 강성과 강도 영향에 대해 분석하고, 매립강판면과 타설접합면에 따른 균열폭 제어 적정성을 평가하였다.

Experimental study on RC beams externally bonded by CFRP sheets with and without end self-locking

  • Chaoyang Zhou;Yanan Yu;Chengfeng Zhou;Xuejun He;Yi Wang
    • Steel and Composite Structures
    • /
    • 제48권5호
    • /
    • pp.599-610
    • /
    • 2023
  • To avoid debonding failure, a novel type of hybrid anchorage (HA) is proposed in this study that uses a slotted plate to lock the ends of the fiber-reinforced polymer (FRP) sheet in addition to the usual bonding over the substrate of the strengthened member. An experimental investigation was performed on three groups of RC beams, which differed from one another in either concrete strength or steel reinforcement ratio. The test results indicate that the end self-locking of the CFRP sheet can improve the failure ductility, ultimate capacity of the beams and its utilization ratio. Although intermediate debonding occurred in all the strengthened beams, it was not a fatal mode of failure for the three specimens with end anchorage. Among them, FRP rupture occurred in the beam with higher concrete strength and lower steel reinforcement ratio, whereas the other two failed by concrete crushing. The beam strengthened by HA obtained a relatively high percentage of increase in ultimate capacity when the rebar ratio or concrete strength decreased. The expressions in the literature were inspected to calculate the critical loads at intermediate debonding, FRP rupturing and concrete crushing after debonding for the strengthened beam. Then, the necessity of further research is addressed.

A high-order gradient model for wave propagation analysis of porous FG nanoplates

  • Shahsavari, Davood;Karami, Behrouz;Li, Li
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.53-66
    • /
    • 2018
  • A high-order nonlocal strain gradient model is developed for wave propagation analysis of porous FG nanoplates resting on a gradient hybrid foundation in thermal environment, for the first time. Material properties are assumed to be temperature-dependent and graded in the nanoplate thickness direction. To consider the thermal effects, uniform, linear, nonlinear, exponential, and sinusoidal temperature distributions are considered for temperature-dependent FG material properties. On the basis of the refined-higher order shear deformation plate theory (R-HSDT) in conjunction with the bi-Helmholtz nonlocal strain gradient theory (B-H NSGT), Hamilton's principle is used to derive the equations of wave motion. Then the dispersion relation between frequency and wave number is solved analytically. The influences of various parameters (such as temperature rise, volume fraction index, porosity volume fraction, lower and higher order nonlocal parameters, material characteristic parameter, foundations components, and wave number) on the wave propagation behaviors of porous FG nanoplates are investigated in detail.

슬립을 고려한 혼합구조 접합부의 비선형 해석 (Nonlinear Analysis of Mixed Structure with Connection Slip)

  • 성재진;허택녕;이윤수;조성용
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.615-622
    • /
    • 2006
  • As construction technique and design are developing, the bridge tend to be longer, and also the type of bridge is verity. Steel and concrete combination improve the mechanics characteristic and economical efficient which Hybrid Structure divide Mixed Structure with Composite Structure. The connected section of the Mixed Structure should integrate steel and concrete that should show the same behavior as well, And also this connection needs big interna1 force and stiffness because it used to be a most dangerous section. This study carry out a nonlinear analysis technique with slip, check out each different type of section force's transfer mechanism on the connection. And this analysis was carried out using parameter that are front plate thickness, connection length, filled concrete strength and so on. We confirmed the profitable type of connection is front backward type. The biggest stiffness and certain stress transmission are showed at the ratio 0.075 between total length and connection length, and also most economical front plate thickness is judged when it set three times thicker than flange.

  • PDF

Effect of porosity in interfacial stress analysis of perfect FGM beams reinforced with a porous functionally graded materials plate

  • Rabia, Benferhat;Daouadji, Tahar Hassaine;Abderezak, Rabahi
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.293-304
    • /
    • 2019
  • In this paper, a general model is developed to predict the distribution of interfacial shear and normal stresses of FG beam reinforced by porous FGM plates under mechanical loading. The beam is assumed to be isotropic with a constant Poisson's ratio and power law elastic modulus through the beam thickness. Stress distributions, depending on an inhomogeneity constant, were calculated and presented in graphicals forms. It is shown that both the normal and shear stresses at the interface are influenced by the material and geometry parameters of the composite beam, and it is shown that the inhomogeneities play an important role in the distribution of interfacial stresses. The results presented in the paper can serve as a benchmark for future analyses of functionally graded beams strengthened by imperfect varying properties plates. Numerical comparisons between the existing solutions and the present new solution enable a clear appreciation of the effects of various parameters. The results of this study indicated that the imperfect functionally graded panel strengthening systems are effective in enhancing flexural behavior of the strengthened FGM beams. This research is helpful in understanding the mechanical behaviour of the interface and design of hybrid structures.

저속충격시 Ball 탄(5.56mm)의 형상변화에 관한 연구 (A Study on the shape deformation of ball projectile(5.56mm) under the low velocity impact)

  • 손세원;이두성;홍성희;김영태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.865-868
    • /
    • 2002
  • This study investigated the shape deformation of ball projectile(5.56mn) under the low energy impact by the use of the drop weight impact tester. ball projectile(5.56mm) consisted of the copper face with a lead core. The impact conditions were changed with the variations of the mass and the drop height of the impact tup. Shape deformation of ball projectile(5.56mm) after low velocity impact was measured using a video microscope and CCD camera. The test result showed that impact energy by changing of drop height of the impact tup affected shape deformation of ball projectile(5.56mm). So, it is important to study the relativity between shape deformation of ball projectile(5.56mm) and ballistic protection of plate(such as hybrid composite laminates) under the high velocity impact.

  • PDF