• Title/Summary/Keyword: Hybrid air-conditioner

Search Result 17, Processing Time 0.036 seconds

Performance Characteristics of a Hybrid Air-Conditioner for Telecommunication Equipment Rooms (통신기지국용 하이브리드 냉방기의 성능특성 연구)

  • Kim, Yong-Chan;Choi, Jong-Min;Kang, Hoon;Yoon, Joon-Sang;Kim, Young-Bae;Choi, Kwang-Min;Lee, Ho-Seong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.874-880
    • /
    • 2006
  • The power density and heat dissipation rate per unit area of the telecommunication equipment have been increased with the technology development in the footprint of telecommunication hardware. A proper heat dissipation method from the PCB module is very important to allow reliable operation of its electronic component. In this study, a hybrid air-conditioner for the telecommunication equipment room was designed to save energy and obtain system reliability. For high outdoor temperatures, the hybrid system operates in the vapor compression cycle, while, for low outdoor temperatures, the hybrid system works in the secondary fluid cooling cycle with no operation of the compressor. The performance of the hybrid air-conditioner was measured by varying outdoor and indoor temperatures. The hybrid air-conditioner yielded 50% energy saving compared with the conventional refrigeration system when the mode switch temperature was $8.3^{\circ}C$.

Hybrid Air-Conditioner Using Both Radiation and Convection (복사-대류 겸용 하이브리드 냉방기)

  • Byun, Ho-Won;Oh, Wang-Kyu;Kim, Nae-Hyun;Choi, Byung-Nam;Lee, Sang-Yeup;Han, Sung-Pil
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.330-333
    • /
    • 2008
  • The hybrid air-conditioner, where air is cooled both by convection and radiation, is developed. The indoor unit of the air-conditioner consists of radiation panel and dehumidification coil, where refrigeration R-134a is supplied by independent refrigeration cycles. Optimum refrigerant charge was 750g for both cycles. Optimum evaporation pressure was 3.7 bar for the radiation panel cycle and 3.9 bar for the dehumidification cycle. The cooling capacity of the radiation panel was 1.01 kW and that of the dehumidification coil was 0.94kW, which yielded COP of 3.3.

  • PDF

A Study on the Solar Cell Charging Equipment for Hybrid Vehicle (Hybrid 자동차용 Solar Cell 충전장치에 관한 연구)

  • Kim, G.S.;Park, S.C.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.157-164
    • /
    • 2011
  • Hybrid car can improve fuel efficiency using a power of motor that is generated during constant-speed or deceleration driving. The motor is located between engine and transmission. But, when voltage of main battery is low, fuel efficiency is low because the voltage can't run the motor. In this situation, this study observed fuel efficiency when using solar cell for assistance power. In order to verify a fuel consumption of hybrid car equipped solar cell for assistance power, the car was tested downtown driving. As hybrid car was equipped solar cell for assistance, fuel consumption was reduced 8.35 % at running air conditioner. And, at air conditioner doesn't work, fuel consumption was reduced 6.88 %. This point of view, CO2 is expected to reduce in similar proportion.

Economic Analysis and Comparison between Hybrid and Central Air Conditioning System (혼합공조와 중앙공조 시스템의 경제성 분석 및 비교)

  • Lee, Yoon-Jong;Kim, Chan-Jung;Moon, Je-Myung;Kim, Cheol-Woo;Seo, Hyeong-Joon;Kim, Gyoung-Rok;Shin, Haeng-Cho;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.334-339
    • /
    • 2007
  • This paper is concerned with economic analysis and comparison between hybrid and central air conditioning system by TRNSYS simulation and Life Cycle Cost(LCC) analysis. Hybrid air conditioning system that is using VAV for interior zone and system air-conditioner for perimeter zone is installed in building A. Central air conditioning system is composed of VAV and convector. The simulation was carried out in mode temperature level control using TRNSYS 16. From the result of simulation and LCC analysis, hybrid air conditioning system was better than central air conditioning system in initial cost and energy consumption.

  • PDF

Development of High efficient BLDC Motor for Electric Air Conditioner of Mild Hybrid Vehicle (Mild Hybrid차량의 전동에어컨용 고효율 BLDC Motor개발)

  • Hur Jin;Jung In-Soung;Ryu Se-Hyun;Kim Joo-Han;Sung Ha-Gyeong;Kang Gyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.923-925
    • /
    • 2004
  • A lot of conventional automotive components driven by mechanical power source are being replaced with electrical ones to comply with the demands of market and customer, therefore the amount of electric energy used in a vehicle will be increased continuously. The increment of electric power demand causes interest on new higher power system such as 42V Power Net, and furthermore necessity for development of energy storage device is highlighted recently. This paper present the design of the BLDC motor for electric air-conditioner in 42V system and compare with the characteristics of several type BLDC motor.

  • PDF

Development of Hybrid Electric Compressor Motor Drive System for Hybrid Electrical Vehicles

  • Jung, Tae-Uk
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.960-968
    • /
    • 2009
  • This paper presents a design optimization process for interior permanent magnet synchronous motors (IPMSM) for hybrid electric compressors (HEC) which are applied to hybrid electrical vehicles. A hybrid electric compressor is composed of an electric motor driving section and an engine driving section which is connected to the engine by a pulley belt. A hybrid electric compressor driving motor requires half of the full driving power of a compressor. Even though an engine is not operated at the idling stop mode, the electric motor drives the air-conditioner compressor by itself so that the air conditioning system can produce its minimum cooling capacity. In this paper, the design optimization of an IPMSM for a 42 (V) applied voltage system is studied using the design of experiment (DOE) and response surface method (RSM) of 6sigma. The driving characteristics of this motor drive system are measured and analyzed by experiment.

Motor Drive System Development of Hybrid Electric Air-con Compressor for HEV (하이브리드 차량을 위한 하이브리드 전동식 압축기 모터 드라이브 시스템 개발)

  • Jung, Tae-Uk;Park, Sung-Jun;Kim, Sung-Il;Hong, Jung-Pyo;Yun, Cheol-Ho;Cha, Hyun-Rok;Kim, Hyung-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1075-1076
    • /
    • 2007
  • The HEV (Hybrid Electrical Vehicle) becomes commercialized recently because of high fuel efficiency and low air pollution. The highest output power system except the traction motor is an air conditioner compressor in HEV system. The full or hybrid electric compressor is applied for HEV. The general HEC (Hybrid Electric Compressor) requires the half power motor and drive system of the full electric compressor because the rated output power of motor drive system is designed to charge the minimum cooling capacity at the time of idle stop. Therefore, this hybrid electric is more economical and practical solution. In this paper, we studied about the motor drive system of hybrid electric compressor for HEV. The applied voltage specification is 42 V, an IPMSM (Interior Permanent Magnet Synchronous Motor) is designed and applied as the compressor drive motor.

  • PDF

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer (하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가)

  • Kim, Sang-Jin;Kim, Eun-Soo;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

Investigation on Characteristics of Interior Permanent Magnet Synchronous Motor according to Pole-Slot Combination (매입형 영구자석 동기전동기의 극 수 슬롯 수 조합에 따른 특성에 관한 연구)

  • Bahn, Ji-Hyung;Kwon, Soon-O;Ha, Seung-Hyonng;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.771-772
    • /
    • 2006
  • Recently, Interior Permanent Magnet Synchronous Motor(IPMSM) is widely used in the industry applications such as power train for hybrid vehicles and compressor motors of air-conditioner due to its high power density and wide speed range. In designing motors, pole slot combination should be chosen properly according to the use of the motor and driving method in the initial design stage, accordingly there have been many researches about pole slot combination. As a part of the studies, this paper presents a comparison of characteristics of concentrated winding IPMSM, such as back-emf, Total Harmonic Distortion(THD) and core losses for each pole slot combination. By comparing the characteristics of each model, this paper can be a guide or reference in determining pole slot combination in the initial design stage.

  • PDF