• 제목/요약/키워드: Hybrid Active Power Filter

검색결과 56건 처리시간 0.02초

싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터 (A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.

Double Tuned Active Filter 기능을 갖는 Single Tuned Active Filter (Single-Tuned Active Filter with Function of Double-Tuned Active Filter)

  • 김찬기;양병모;정길조
    • 전력전자학회논문지
    • /
    • 제9권6호
    • /
    • pp.544-552
    • /
    • 2004
  • 본 논문은 Single Tuned Filter를 사용하여 11차와 13차 고조파를 동시에 제거하는 Hybrid 능동필터를 제안하였다. 제안된 Hybrid 능동필터는 Hybrid 능동필터의 Detuning 보상능력을 이용한 것으로, 하나의 필터를 이용하여 2개 이상의 고조파를 제거할 수 Topology를 보여주고 있다. 본 논문에서 다루는 Hybrid 능동필터는 Detuning 보상능력을 이용한 것이기 때문에 인버터 출력전압을 최적으로 설계하는 것이 필수적이다. 본 논문은 수동필터 부분의 커패시터 용량과 HVDC 시스템에서 발생되는 고조파 전류의 크기 그리고 수동필터의 공진주파수와 제어모드에 따라 인버터 출력전압이 변화함을 확인하였고, 이에 따른 최적의 인버터 전압을 구하였다.

An Over Current Protection Scheme for Hybrid Active Power filter

  • Lee Woo-Cheol;Chae Beom-Seok;Hyun Dong-Seok;Lee Taeck-Kie
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.571-575
    • /
    • 2001
  • A protection scheme for hybrid active power filters, which is combined shunt passive filter and small rated series active filter, is presented and analyzed in this paper. The proposed series active power filter operated as a high impedance 'k($\Omega$)' to the fundamental component when over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame (SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the series active power filter without additional protection circuits. The validity of proposed protection scheme is investigated through experimental result for the prototype hybrid active power filter system.

  • PDF

Optimal Allocation Method of Hybrid Active Power Filters in Active Distribution Networks Based on Differential Evolution Algorithm

  • Chen, Yougen;Chen, Weiwei;Yang, Renli;Li, Zhiyong
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1289-1302
    • /
    • 2019
  • In this paper, an optimal allocation method of a hybrid active power filter in an active distribution network is designed based on the differential evolution algorithm to resolve the harmonic generation problem when a distributed generation system is connected to the grid. A distributed generation system model in the calculation of power flow is established. An improved back/forward sweep algorithm and a decoupling algorithm are proposed for fundamental power flow and harmonic power flow. On this basis, a multi-objective optimization allocation model of the location and capacity of a hybrid filter in an active distribution network is built, and an optimal allocation scheme of the hybrid active power filter based on the differential evolution algorithm is proposed. To verify the effect of the harmonic suppression of the designed scheme, simulation analysis in an IEEE-33 nodes model and an experimental analysis on a test platform of a microgrid are adopted.

Three-Phase Hybrid Shunt Filters for Power Quality Improvement

  • Bhuvaneswari, G.;G.Nair, Manjula
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.257-264
    • /
    • 2007
  • Active power filters can be cost-effective for use in practical systems with the insertion of a few passive elements in shunt or series configuration. The resulting hybrid filters can be designed to provide dominant lower order harmonic elimination and reactive power support by the passive elements so that the burden on the active filter counterpart is reduced. In this paper, the rate reduction in the shunt active filter is estimated when it is connected in parallel with suitable passive tuned harmonic filters. The active filtering system is based on an appropriate control scheme. The simulation and the experimental results of the shunt active filter, along with the estimated value of reduction in rating, show that the hybrid shunt filtering system is quite effective in compensating for the harmonics and reactive power, in addition to being cost-effective.

회전좌표계를 이용한 단상 하이브리드형 능동 전력필터 (Single-Phase Hybrid Active Power Filter Using Rotating Reference Frame)

  • 김진선;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권8호
    • /
    • pp.377-386
    • /
    • 2005
  • This paper presents the control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active Power filters. To construct two phase system, an imaginary second phase was made. In this proposed method, the new signal which is the delayed through the filtering by the phase-delay property of low-pass filter is used as the secondary phase. Because two-phases have the different phase, the instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames In order to verify the validities of the proposed control methods, experiments are carried out with the prototypes of single-phase hybrid active power filter.

외란관측기를 사용한 복합형능동전력필터의 Deadbeat 제어에 관한 연구 (Deadbeat control of Hybrid Active Power filter using Distrubance-observer)

  • 조광승
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.123-126
    • /
    • 2000
  • When LC filter is connected parallel to the Active Power Filter a problem of the resonance between the Active Power Filter(AF) and LC filte often arises. in this paper Deadbeat control of Hybrid Active Power Filter using Disturbance-observer is introduced to solve this problem. By the estimation of the harmonics disturbance using proposed disturbance observer the compensation characteristics of the AF is improved and the resonant current is suppressed. The validity of proposed disturbance observer is verified from simulation results using PSIM

  • PDF

멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터 (A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters)

  • 김윤호;김수홍;이강희
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

DC-DC 전력변환장치용 Hybrid EMI 필터 개발 (Development of the Hybrid EMI Filter for DC-DC Converter)

  • 이동호;유진완;박종연
    • 산업기술연구
    • /
    • 제34권
    • /
    • pp.71-78
    • /
    • 2014
  • Recently, using the electronic devices was increased with semiconductor developments. So, the EMI(Electromagnetic interference) problem become to important issue for coexistence with each electronic devices. The EMI is caused by switching operation from the power switches as the FET and the transistor in power conversion devices. In this paper, the hybrid EMI filter that composed with active components and passive components was described. The EMI filter is applied to the 160 watts LED driver experimentally verify the performance. The hybrid EMI filter is compared with non-filter, only passive filter and only active filter. The proposed EMI filter attenuated CM noise more than traditional passive filter.

  • PDF

비선형 부하를 위한 복합전력필터 (Hybrid Active Filter System for High Power Non-linear Loads)

  • 강민수;노윤성;김수곤;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.182-185
    • /
    • 2003
  • Proposed Hybrid System is composed of phase leading capacitor banks, LC passive filters and active power filter. The passive power filter in parallel connection eliminate the 5th and 7th harmonics. The Variable capacitor banks correct the most of power factor, and the active power filter takes charge of remainder,

  • PDF