• 제목/요약/키워드: Hurwitz stability

검색결과 29건 처리시간 0.024초

고부하용 카운터 밸란스 밸브의 동적 특성에 관한 연구 (A Study on the Dynamic Characteristics of Counter Balance Valve for High Load)

  • 성원준;정광식;이승현
    • Tribology and Lubricants
    • /
    • 제18권1호
    • /
    • pp.68-74
    • /
    • 2002
  • In this study, the dynamic characteristics of the spool type counter balance valve are studied. The nonlinear governing differential eguations are derived. Routh-Hurwitz criterion is used to characterize the linearized eguations. Static and dynamic experiments are carried out for the determination of parameters that are necessary for the analysis and the stability of the system.

양변위 되먹임 제어기의 안정성, 제어 성능 및 설계 방법 (The Stability Conditions, Performance and Design Methodology for the Positive Position Feedback Controller)

  • 곽문규;한상보;허석
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.208-213
    • /
    • 2004
  • This paper is concerned with the theoretical estimation of the single-input single-output(SISO) positive position feedback(PPF) controller and the derivation of the stability conditions for the multi-input multi-output (MIMO) PPF controller. Although the stability condition for the SISO PPF controller was derived in the earlier works, the question regarding the performance estimation of the SISO PPF controller has never been studied theoretically. Hence, the SISO PPF controller for the single degree-of-freedom system was first investigated and then control parameters including gain, the filter frequency, and the damping factor of the PPF controller were analyzed in detail thus providing the design methodology for the SISO PPF controller. In the case of real structure. there are infinite number of natural modes so that some modes are to be controlled by a limited number of actuator and sensor. Based on the theoretical results on the SISO PPF controller, the stability condition for the multi-input multi-output PPF controller was derived when only the few number of modes are to be controlled. The control spillover problem is also discussed in detail.

능동동조질량감쇠기와 수정 PPF 제어기를 이용한 구조물의 능동진동제어 (Active Vibration Control of Structure Using Active Tuned Mass Damper and Modified PPF Controller)

  • 김기영;곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.550-555
    • /
    • 2007
  • This paper is concerned with the active vibration control of building structure by means of the active tuned mass damper and the modified positive position feedback controller. To this end, one-degree-of-freedom spring-mass-damper system equipped with ATMD is considered. The stability condition for the addressed system when applying the proposed PPF controller is derived by Routh-Hurwitz stability criterion. The stability condition shows that the modified PPF controller is absolutely stable if the controller gain is positive, so that the modified PPF controller can be used without difficulty. Theoretical study shows that the modified PPF controller can effectively suppress vibrations as the original PPF controller does in smart structure applications. To investigate the validity of the modified PPF controller, a simple experimental structure with an ATMD system driven by DC motor was built. The modified PPF control algorithm was implemented on Atmel 128 microcontroller. The experimental result shows that the modified PPF controller can also suppress vibrations for the real structure.

  • PDF

능동동조질량감쇠기와 수정 PPF 제어기를 이용한 구조물의 능동진동제어 (Active Vibration Control of Structure Using Active Tuned Mass Damper and Modified PPF Controller)

  • 김기영;곽문규
    • 한국소음진동공학회논문집
    • /
    • 제18권2호
    • /
    • pp.224-230
    • /
    • 2008
  • This paper is concerned with the active vibration control of building structure by means of the active tuned mass damper and the modified positive position feedback controller. To this end, one-degree-of-freedom spring-mass-damper system equipped with ATMD is considered. The stability condition for the addressed system when applying the proposed PPF controller is derived by Routh-Hurwitz stability criterion. The stability condition shows that the modified PPF controller is absolutely stable if the controller gain is positive. so that the modified PPF controller can be used without difficulty. Theoretical study shows that the modified PPF controller can effectively suppress vibrations as the original PPF controller does in smart structure applications. To investigate the validity of the modified PPF controller, a simple experimental structure with an ATMD system driven by DC motor was built. The modified PPF control algorithm was implemented on Atmel 128 microcontroller. The experimental result shows that the modified PPF controller can also suppress vibrations for the real structure.

유연한 단일 링크 로봇의 제어기 설계에 대한 연구 (Study on the PID Controller Design for One-Link Robot)

  • 강신천;박용운;고정호
    • 전자공학회논문지SC
    • /
    • 제44권3호
    • /
    • pp.9-13
    • /
    • 2007
  • 대부분의 공학 시스템은 비선형 시스템이지만 비선형 요소가 어떤 바운드된 섹터 내에서만 존재할 때 이러한 비선형 시스템을 통상 Lure-Postnikov system이라 부르며 기계 시스템에서 자주 직면하게 된다. Lure-Postnikov system을 안정화 시키는 제어기를 해석하는 방법에 대해서는 그동안 상당한 연구가 이루어져 왔지만 PID 혹은 저차 제어기와 같은 고정된 구조를 갖는 제어기의 설계에 대한 연구는 아직 미미한 상태이다. 본 논문에서는 하나의 실수 다항식과 허수 다항식의 패밀리를 Hurwitz 다항식으로 만드는 제어 변수의 조합을 선형 부등식을 통하여 구하는 최근의 연구 결과를 이용하여 Lure-Postnikov system을 안정화 시키는 제어기를 체계적으로 설계하는 새로운 방법을 제시하고자 한다. 이 방법은 무기체계 시스템에서 흔히 쓰이는 유연한 단일 링크를 갖는 로봇 시스템에 적용하여 임의의 차수의 제어기를 체계적으로 설계할 수 있음을 보여준다.

센스리스 벡터제어의 속도추정 기에 사용되는 PI제어기의 최적이득 설계 (The optimum gain design of PI Controller using a speed estimation in Sensorless vector-control)

  • 김형준;조내수;구본호;윤경섭;권우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.614-616
    • /
    • 2004
  • It is waste of time in industrial plant that the PI controller gain tuning. The PI controller has many trial-and-error steps for gain design. This paper proposes the optimum gain design of PI controller using a speed estimation in sensorless vector-control. In this method, a degree of stability and Hurwitz theory are applied and the controller gain is expressed by system parameters.

  • PDF

A New Control Strategy for Input Voltage Sharing in Input Series Output Independent Modular DC-DC Converters

  • Yang, Wei;Zhang, Zhijie;Yang, Shiyan
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.632-640
    • /
    • 2017
  • Input series output independent (ISOI) dc-dc converter systems are suitable for high voltage input and multiple output applications with low voltage rating switches. This paper proposes a novel control strategy consisting of one output voltage regulating (OVR) control loop and n-1 (n is the number of modules in the ISOI system) input voltage sharing (IVS) control loops. An ISOI system with the proposed control strategy can be applied to applications where the output loads of each module are the same. Under these conditions, IVS can be achieved and output voltages copying can be realized in an ISOI system. In this control strategy there is only one controller for each module and the design process of the control loops is simple. Since no central controller is needed in the system, modularity of the system is improved. The operation principle of the new control strategy is introduced and the control effect is simulated. Then the output power and voltage characteristics of an ISOI system under this new control strategy are analyzed. The stability of the proposed control strategy is explored base on a Hurwitz criterion, and the design guide line of the control strategy is given. A two module ISOI system prototype is fabricated and tested in the laboratory. Experimental results verify the effectiveness of the proposed control strategy.

Optimized AI controller for reinforced concrete frame structures under earthquake excitation

  • Chen, Tim;Crosbie, Robert C.;Anandkumarb, Azita;Melville, Charles;Chan, Jcy
    • Advances in concrete construction
    • /
    • 제11권1호
    • /
    • pp.1-9
    • /
    • 2021
  • This article discusses the issue of optimizing controller design issues, in which the artificial intelligence (AI) evolutionary bat (EB) optimization algorithm is combined with the fuzzy controller in the practical application of the building. The controller of the system design includes different sub-parts such as system initial condition parameters, EB optimal algorithm, fuzzy controller, stability analysis and sensor actuator. The advantage of the design is that for continuous systems with polytypic uncertainties, the integrated H2/H∞ robust output strategy with modified criterion is derived by asymptotically adjusting design parameters. Numerical verification of the time domain and the frequency domain shows that the novel system design provides precise prediction and control of the structural displacement response, which is necessary for the active control structure in the fuzzy model. Due to genetic algorithm (GA), we use a hierarchical conditions of the Hurwitz matrix test technique and the limits of average performance, Hierarchical Fitness Function Structure (HFFS). The dynamic fuzzy controller proposed in this paper is used to find the optimal control force required for active nonlinear control of building structures. This method has achieved successful results in closed system design from the example.

Integrating Resilient Tier N+1 Networks with Distributed Non-Recursive Cloud Model for Cyber-Physical Applications

  • Okafor, Kennedy Chinedu;Longe, Omowunmi Mary
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권7호
    • /
    • pp.2257-2285
    • /
    • 2022
  • Cyber-physical systems (CPS) have been growing exponentially due to improved cloud-datacenter infrastructure-as-a-service (CDIaaS). Incremental expandability (scalability), Quality of Service (QoS) performance, and reliability are currently the automation focus on healthy Tier 4 CDIaaS. However, stable QoS is yet to be fully addressed in Cyber-physical data centers (CP-DCS). Also, balanced agility and flexibility for the application workloads need urgent attention. There is a need for a resilient and fault-tolerance scheme in terms of CPS routing service including Pod cluster reliability analytics that meets QoS requirements. Motivated by these concerns, our contributions are fourfold. First, a Distributed Non-Recursive Cloud Model (DNRCM) is proposed to support cyber-physical workloads for remote lab activities. Second, an efficient QoS stability model with Routh-Hurwitz criteria is established. Third, an evaluation of the CDIaaS DCN topology is validated for handling large-scale, traffic workloads. Network Function Virtualization (NFV) with Floodlight SDN controllers was adopted for the implementation of DNRCM with embedded rule-base in Open vSwitch engines. Fourth, QoS evaluation is carried out experimentally. Considering the non-recursive queuing delays with SDN isolation (logical), a lower queuing delay (19.65%) is observed. Without logical isolation, the average queuing delay is 80.34%. Without logical resource isolation, the fault tolerance yields 33.55%, while with logical isolation, it yields 66.44%. In terms of throughput, DNRCM, recursive BCube, and DCell offered 38.30%, 36.37%, and 25.53% respectively. Similarly, the DNRCM had an improved incremental scalability profile of 40.00%, while BCube and Recursive DCell had 33.33%, and 26.67% respectively. In terms of service availability, the DNRCM offered 52.10% compared with recursive BCube and DCell which yielded 34.72% and 13.18% respectively. The average delays obtained for DNRCM, recursive BCube, and DCell are 32.81%, 33.44%, and 33.75% respectively. Finally, workload utilization for DNRCM, recursive BCube, and DCell yielded 50.28%, 27.93%, and 21.79% respectively.