SELECTION OF THE SENSORS FOR THE ENVIRONMENTAL CONTROL SYSTEMS OF PIG-HOUSING IN TEMPERATE ZONE

  • Chang, Dong-Il;Chang, Hong-Hee
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1126-1135
    • /
    • 1996
  • This study was conducted to select the sensors for measuring temperature, relative humidity, and air velocity among the major environmental factors affecting the pig productivity as a part of the study for the optimum production system model development of pig-housing. The study results are summarized as the follows : Two sensors , HMP233L and HANI, were tested for measuring temperature and relative humidity , Test results were analyzed by the statistical methods. And the sensor, HMP233L was selected as a proper sensor for temperature sand relative humidity measurement . An air velocity sensor was tested. Test results showed that its accuracy was low and incongruent for the air velocity measurement when it was lower than 4m/s.

  • PDF

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

Measurement of Agricultural Atmospheric Factors Using Ubiquitous Sensor Network - Temperature, Humidity and Light Intensity - (유비쿼터스 센서네트워크를 이용한 농업환경인자 측정 - 온도, 습도, 조도 -)

  • Chang, Young-Chang;Chung, Sun-Ok;Han, In-Song;Noh, Kwang-Mo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.122-129
    • /
    • 2011
  • This study was performed to develop a wireless system for measuring agricultural atmospheric factors using ubiquitous sensor network(USN). In the study, temperature, humidity and light intensity were selected and evaluated as major agricultural atmospheric factors. An USN system was designed and implemented by using Zigbex I and II (mote sensor nodes of MICA series) provided by Hanback Electronics, Korea. The system was tested in a greenhouse and an orchard. The experiment results showed that the suggested USN measuring system would be very effective on comprehensive measurement of the selected factors on the basis of time, day, spatial sequence with reasonable costs.

Estimation of Grounding Resistance by Correlation Analysing Change Factors of Soil Resistivity and Grounding Resistance (토양환경 변화와 접지저항의 상관관계 분석을 통한 접지 저항값 예측 연구)

  • Choi, Sun-Kyu;Lee, Kyu-Young;Moon, Young-Ho;Shim, Keon-Bo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2020
  • The purpose of this paper is to improve the grounding point measurement method for the maintenance of the earth resistance of the distribution line. This study defines the correlation among humidity of the soil, the earth resistivity and the grounding resistance. Based on the results of the study, the grounding resistance value measurement should be limited to the location where the earth resistivity change is large, and the measurement time and cost can be greatly reduced.

Investigation of Standard Error Range of Non-Contact Thermometer by Environment (외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정)

  • Kim, Jeongeun;Park, Sangwoong;Choi, Heakyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

Development of Direct Measurement Device for Alveolar Breath Carbon Monoxide

  • Jo, Wan-Kuen;Oh, Jee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E4
    • /
    • pp.181-190
    • /
    • 2002
  • A novel portable device for the direct measurement of alveolar breath carbon monoxide (CO) was developed. The major components of the device include a mouthpiece, non-rebreathing two-way valve, Teflon tube, and CO dosimeter. An alveolar CO measurement can be completed within 1.5 min when using the proposed device and measurement protocol. Measurements could be read to the nearest 0.1 ppm. Humidity did not influence the CO measurements taken by the CO dosimeter, plus there were no problems associated with the recovery and carryover of CO through the device. The criterion for significance in statistical analyses was p< 0.05. The average recovery was 103 and 99% for recovery and carryover experiments, respectively. Test results using the proposed alveolar CO measurement system reflected a good reproducibility. This reproducibility was also supported by the finding that the relative standard deviations (RSDs) of the data sets were less than 7% for the loss experiment and less than 8% for the carryover experiment. Consequently, it would appear that the proposed device can be effectively applied to measure CO levels found in breath, thereby overcoming several disadvantages associated with the conventional bag and adsorbent tube sampling methods.

The Design and fabrication of Capacitive Humidity Sensor Having Interdigital Electrodes and Its Signal Processing Circuit (빗살전극형 정전용량형 습도센서와 그 신호처리회로의 설계 제작)

  • Kang, Jeong-Ho;Lee, Jae-Yong;Kim, Woo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.26-30
    • /
    • 2006
  • For the purpose of developing capacitive humidity sensor having interdigital electrodes, interdigital electrode was modeled and simulated to obtain capacitance and sensitivity as a function of geometric parameters like the structural gap and thickness. For the development of ASIC, switched capacitor signal processing circuits for capacitive humidity sensor were designed and simulated by Cadence using $0.25{\mu}m$ CMOS process parameters. The signal processing circuits are composed of amplifier for voltage gain control, and clock generator for sensor driving and switch control. The characteristics of the fabricated sensors are; 1) sensitivity is 9fF/%R.H., 2) temperature coefficient of offset(TCO) is $0.4%R.H./^{\circ}C$, 3) nonlinearity is 1.2%FS, 4) hysteresis is 1.5%FS in humidity range of $3%R.H.{\sim}98%R.H.$. The response time is 50 seconds in adsorption and 70 seconds in desorption. Fabricated process used in this capacitive humidity sensor having interdigital electrode are just as similar as conventional IC process technology. Therefore this can be easily mass produced with low cost, simple circuit and utilized in many applications for both industrial and environmental measurement and control system, such as monitoring system of environment, automobile, displayer, IC process room, and laboratory etc.

Thermal and Humidity Sensing Properties of Heat Resistant Polyimide Thin Film Manufactured by Dry Process (건식법에 의해 제조된 내열성 폴리이미드박막의 열적특성 및 습도감지특성)

  • Lim, Kyung-Bum;Kim, Ki-Hwan;Hwang, Sun-Yang;Kim, Jong-Yoon;Hwang, Myung-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1080-1086
    • /
    • 2007
  • The aim of this paper is to establish the optimum fabrication condition of specimens, using the Vapor Deposition Polymerization Method(VDPM), which is one of modesto prepare functional organic thin films using a dry process, and to develop a thin film type humidity sensor which has good humidity sensitive characteristics. The inner part of the film became denser and roughness of the film surface eased as curing temperature increased so that thickness of the film could be made uniform. This also shows the appropriate curing temperature was $250^{\circ}C$. The basic structure of the humidity sensor is a parallel capacitor which consists of three layers of Aluminum/Polyimide/Aluminum. The result of SEM and AFM measurement shows that the thickness of PI thin films decreased and the refraction increased as curing temperature increased, which indicates that a capacitance-type humidity sensor utilizing polyimide thin film is fabricated on a glass substrate. The characteristics of fabricated samples were measured under various conditions, and the samples had linear characteristics in the range of 20-80 %RH, independent of temperature change, and low hysteresis characteristic.

Development of a Fully-Controlled Phytotrons -Temperature and Humidity Control System- (완전제어형(完全制御型) 실험용(實驗用) 작물생육장치(作物生育裝置)의 개발(開發)(I) -온(溫)·습도(濕度) 제어(制御) 시스템-)

  • Lee, K.C.;Ryu, K.H.;Noh, S.H.;Hong, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.1
    • /
    • pp.55-64
    • /
    • 1992
  • The aim of this study was to develop a phytotron for studying the effects of environmental factors such as temperature and humidity on plant growth. This equipment consists of the growth chamber, and the measurement and control system including control algorithms required for optimum operation. As the first step of the study, a temperature and humidity control system was developed. The results of this study are summarized as follows ; 1. Pt-100 was selected to measure temperature and a linearized op-amp circuit was developed for signal conditioning. 2. Pt-100 wet bulb thermometer based on Asmann's principle was developed to measure relative humidity. 3. Temperature and relative humidity conditions were controlled by ON-OFF and PWM operation using a PID controller. And an autotuning algorithm using the characteristics of step response was developed to determine optimal PID constants which were independent of the size of apparatus and environmental factors. 4. Under the ambient temperature of $20^{\circ}C{\sim}25^{\circ}C$, the temperature was kept within the error of ${\pm}0.3^{\circ}C$ in the range of $10^{\circ}C{\sim}40^{\circ}C$, and the relative humidity was kept within the error of ${\pm}5%$ in the range of ${\pm}50%{\sim}90%$.

  • PDF

The Design and Fabrication of Capacitive Humidity Sensor Having Interdigit Electrodes and its Signal Conditional Circuitry (빗살형 전극을 가지는 정전용량형 습도센서와 그 신호처리회로의 설계와 제작)

  • Park, Se-Kwang;Kang, Jeong-Ho;Park, Jin-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.3
    • /
    • pp.144-148
    • /
    • 2001
  • For the purpose of developing capacitive humidity sensor having interdigit electrodes, interdigit electrode was modeled and simulated to obtain capacitance and sensitivity as a function of geometric parameters like the structural gap and thichness. For the development of ASIC, switched capacitor signal conditioning circuits for capacitive humidity sensor were designed and simulated by cadence using 0.25um CMOS process parameters. The signal conditioning circuits are composed of amplifier for voltage gain control, and clock generator for sensor driving and switch control The characteristics of the fabricated sensors are; 1) sensitivity is 9fF/%R.H., 2) temperature coefficient of offset(TCO) is 0.4%R.H./$^{\circ}C$, 3) nonlinearity is 1.2%FS, 4) hysteresis is 1.5%FS in humidity range of 3%R.H. ${\sim}$ 98%R.H.. The response time is 50 seconds in adsorption and 70 seconds in desorption. Fabricated process used in this capacitive humidity sensor having interdigit electrode are just as similar as conventional IC process technology. Therefore this can be easily mass produced with low cost, simple circuit and utilized in many applications for both industrial and environmental measurement and control system, such as monitoring system of environment, automobile, displayer, IC process room, and laboratory etc..

  • PDF