• Title/Summary/Keyword: Humidity control

Search Result 1,148, Processing Time 0.025 seconds

Real-Time Soil Humidity Monitoring Based on Sensor Network Using IoT (IoT를 사용한 센서 네트워크 기반의 실시간 토양 습도 모니터링)

  • Kim, Kyeong Heon;Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.459-465
    • /
    • 2022
  • This paper reports a method to use a wireless sensor network deployed in the field to real-time monitor soil moisture, warning when the moisture level reaches a specific value, and wirelessly controlling an additional device (LED or water supply system, etc.). In addition, we report all processes related to wireless irrigation system, including field deployment of sensors, real-time monitoring using a smartphone, data calibration, and control of additional devices deployed in the field by smartphone. A commercially available open-source Internet of Things (IoT) platform, NodeMCU, was used, which was combined with a 9V battery, LED and soil humidity sensor to be integrated into a portable prototype. The IoT-based soil humidity sensor prototype deployed in the field was installed next to a tree for on-site demonstration for the measurement of soil humidity in real-time for about 30 hours, and the measured data was successfully transmitted to a smartphone via Wifi. The measurement data were automatically transmitted via e-mail in the form of a text file, stored on the web, followed by analyses and calibrations. The user can check the humidity of the soil real-time through a personal smartphone. When the humidity of a soil reached a specific value, an additional device, an LED device, placed in the field was successfully controlled through the smartphone. This LED can be easily replaced by other electronic devices such as water supplies, which can also be controlled by smartphones. These results show that farmers can not only monitor the condition of the field real-time through a sensor monitoring system manufactured simply at a low cost but also control additional devices such as irrigation facilities from a distance, thereby reducing unnecessary energy consumption and helping improve agricultural productivity.

Development of a Air-jet Water Sprayer for Dust Generation Control in the Production Sites of Gloves Making Plants (장갑공장의 분진발생 억제를 위한 에어젯 노즐의 개발)

  • Kim, Jin-Hyun;Choi, Hyun-kuk;Kim, Ki-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.2
    • /
    • pp.69-78
    • /
    • 2009
  • Dust in the fabric production sites is increased by the static electricity in air which is generated in the manufacturing process. The static electricity is shown in inverse proportion to humidity of the production sites. The optimum humidity rate for the filament in the production process has been established as 65~75%. Where as, average humidity rate of production site is estimated as 40%. Therefore, it is necessary to raise the humidity rate by 30% to maintain appropriate humidity to control generation of static electricity and dust in the production sites. In this study, a new air-jet water sprayer was developed and it can produce $10{\mu}m$ sprayed particles. When the air-jet water sprayer was operated on the production site dust generation rate was shown far below the environmental standard. It is assumed that when the air jet sprayers was applied to 1,000 fabric machines of 5 gloves making plants, its productivity and rates of operation will be improved by value of about 2.5 billion Won a year.

  • PDF

Fabrication of Humidity Control Ceramics from Drinking-Water Treatment Sludge and Onggi Soil

  • Lee, Min-Jin;Lee, Hyeon-Jun;Kim, Kyungsun;Hwang, Hae-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.3
    • /
    • pp.362-366
    • /
    • 2016
  • In this study, humidity control ceramics with good adsorption/desorption capabilities and high strength were fabricated from drinking-water treatment sludge (DWTS) and Onggi soil. The DWTS powder heat-treated at $800^{\circ}C$ and Onggi soil were mixed at weight ratios of 40:60, 50:50, 60:40, and 70:30 and fired at $800-1000^{\circ}C$. With increasing DWTS content, density and flexural strength increased. For the sample with a DWTS:Onggi soil weight ratio of 70:30, porosity and specific surface area decreased with increasing firing temperature, attributed to densification and grain growth at high firing temperatures. From the results obtained, a firing temperature of $800^{\circ}C$ is the optimum condition for fabricating humidity control ceramics with good adsorption/desorption capabilities and strength. The maximum adsorbed amount for the sample fired at $800^{\circ}C$ was $439g/m^2$.

An Experimental Study on the Temperature and Humidity Evaluation in the Summer and Winter Season of the Korean Traditional Houses in Chonnam Province (전남지방 전통주택 하절기와 동절기의 온습도 평가에 관한 실험적 연구)

  • Lee, Tai-Kang;Choi, Eun-Seok;Kim, Hang;Kim, Hyung-Ryul;Gi, No-Gab;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Korean Traditional houses has been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various passive system of using natural materials, considering micro climate, building lay out, and these system are more natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed control performance of outdoor environment of five Korean traditional houses during the summer and winter. These houses are varied with lay out and floor plan to reflect the way of control for environmental condition, surveyed the reverberation time and sound level difference between rooms of the main living room and other main floored room, master room and kitchen. Especially air temperature and humidity have been measured simultaneously in each rooms to compare with outdoor condition. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls.

Design Clean Room of Controled Temperature and Humidity using ATmega128 (ATmega128를 이용한 온.습도 자동제어 모형 제작)

  • Kim, Min-Gu;Kuh, Tae-Hoi;Kim, Young-Min;Shim, Saero-Eol;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.77
    • /
    • pp.59-65
    • /
    • 2007
  • Nowaday, our life is closely related to temperature and the humidity. To control the temperature and the humidity have pursued the comfort environment. We develop that form ware is controled temperature and humidity that used the ATmega128. We embody home-automation system to use the ATmega128, temperature sensor, LCD, relay device and peltier device.

Mock-up Model of the Environment Assessment Study on Red-clay and Cement (Mock-up모델을 이용한 황토 및 시멘트의 환경요소 평가 연구)

  • Choi, Yool;Song, Hyeun-Guen
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study is to measure the environmental effects of different alternative building materials. The following building materials were tested: clay bricks, cement wall, and red-clay plaster. Four mock-up models were constructed using clay bricks, cement wall, red-clay plaster and the last model as the control model. The effects of the above four building materials on temperature, humidity, the emissions of formaldehyde, and V.O.C were measured. This experiment was conducted during September. The conclusions are as follows. Clay bricks were able to control temperature, humidity and filter formaldehyde by itself. The environment within the cement wall was not affected by the humidity changes outside. Red-clay plaster walls had little impact on the environment because it is very thin.!

A Study on The Control of Humidification and Dew Condensation by On/Off Control (On/Off 제어에 의한 습도와 결로의 제어에 관한 연구)

  • Park, Dea-Heum;Kim, Du-Hee;Kim, Kyoung-Hoon;Jung, Young-Guan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.835-841
    • /
    • 2011
  • The humidification is essential for performance enhancement of the electrolysis of PEMFC because proton conductivity depends on hydration of the proton exchange membrane. In this study, the humidification experiment did about On/Off control the humidification and dew condensation for PEMFC by using of the membrane humidifiers. As the results, it was possible to approximation control of the humidity by using of the solenoid valve On/Off control on the membrane humidifier. Also the problem on the dew condensation was resolved by approximation humidity control through solenoid valve On/Off control and the removal of the dew condensation in the flow channel was verified through visualization experiment.

Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement (양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석)

  • Park, Cheol-Woo;Park, Young-Hoon;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

Positive Study of How Green Zones in the City Effect the Relief of Micro-Climate Control (도시녹지가 미기상조절에 미치는 실증적 연구)

  • 윤용한
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.2
    • /
    • pp.279-286
    • /
    • 2004
  • This study observed the temperature and humidity within the green zone to understand the effect that land coverage and the structure of forests have on the relief of micro-climate control. Based on this set of data, this study interpreted, through the regression analysis, the relevance of land coverage of the green zone with temperature and distribution of humidity, as well as the amount of green with the relief of microclimate control. The results of the study demonstrated that high temperature regions were formed in barren areas, and low temperature regions in forests or near the water. In particular, low temperature was found in areas covered with tall and small trees, the water surrounded by forests and areas enclosing small rivers. Furthermore, mechanisms causing low temperature were, among others, the ratio of land coverage (forest, grassland, water). In fact, the temperature reduction effect varied in accordance with the types and ratios of the land coverage. Humidity also showed a close correlation with the distribution of temperature high temperature areas had low humidity and low temperature areas had high humidity. Such a phenomenon.

Monitoring of Atmospheric Corrosivity inside Steel Upper Box Girder in Yeongjong Grand Bridge

  • Li, SeonYeob
    • Corrosion Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.87-94
    • /
    • 2011
  • The typical corrosion prevention method inside the steel upper box girder in a suspension bridge involves the use of paints. However, in an effort to reduce environmental impact and cost, the suspension portion of the Yeongjong Bridge, Korea utilizes dehumidification systems to control humidity and prevent corrosion inside its box girder. Maintaining a uniform humidity distribution at the proper level inside the box girder is critical to the successful corrosion control. In this study, the humidity and the resultant atmospheric corrosivity inside the box girder of the Yeongjong Bridge was monitored. The corrosion rate of the steel inside the box girder was obtained using thin-film electrical resistance (TFER) corrosion sensors. Time-of-wetness (TOW) measurements and the deposition rates of atmospheric pollutants such as $Cl^{-}$ and $SO_{x}$ were also obtained. Classification of the atmospheric corrosivity inside the box girder was evaluated according to ISO 9223. As a result, no corrosion was found in the upper box girder, indicating that the dehumidification system used in the Yeongjong Bridge is an effective corrosion control method.